Search talk: setting value of variable

 
<< < 1 .. 14 15 16 17 18 .. 134 > >> (Page 16 of 134)

Python Script for Finding "Last saved with" Value CODESYS Forge talk (Thread)
Python Script for Finding "Last saved with" Value
Last updated: 2024-01-29

CAA SerialCOM - hCom Reset max value 1023 CODESYS Forge talk (Thread)
CAA SerialCOM - hCom Reset max value 1023
Last updated: 2024-03-29

Post by nathant on Can't open online view of FB instance from code editor, only from Device/POU windows CODESYS Forge talk (Post)
Hello, The title pretty much says it all. When trying to open a FB from the CFC/Ladder/SFC editors while online, the FB does not open in an online view of that specific instance. Instead, it opens an offline view with '???' shown for the value of any variable. This makes debugging extremely cumbersome, as I have to find each FB in the POU window and select the specific instance I am trying to view. Anyone know the cause/solution for this? Thanks.
Last updated: 2023-11-08

Post by simotion on Pointer to Softmotion axis CODESYS Forge talk (Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25

Post by timvh on FB string and naming CODESYS Forge talk (Post)
I see, you want to initialize the FB. To be able to initialise it like you described, you need to add the FB_Init method to your FB. (right click on the FB, select add object --> method). Then press the arrow down, to select the FB_Init (overwrite default implementation). In the VAR_INPUT section of this method, add the variable --> Tag : STRING; Then in the code section of this method add: THIS^.Tag := Tag; // copy initial value to local variable in FB Search Google if you want to know more about FB_Init. PS, reflection + instance path, is also an option if you want to get the full name of the instance (path) of the Function Block. See: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_instance_path.html
Last updated: 2024-09-30

CODESYS V35SP12 does not save data setting with rapsberry after reboot CODESYS Forge talk (Thread)
CODESYS V35SP12 does not save data setting with rapsberry after reboot
Last updated: 2018-04-17

setting up Raspberry pi as an opc ua Server with UaExpert as Client CODESYS Forge talk (Thread)
setting up Raspberry pi as an opc ua Server with UaExpert as Client
Last updated: 2024-09-11

Setting up Raspberry pi as an Opc ua Server with UaExpert as Client CODESYS Forge talk (Thread)
Setting up Raspberry pi as an Opc ua Server with UaExpert as Client
Last updated: 2024-09-11

3.5.17: Setting up OPCUA Client data source to another PLC OPCUA server CODESYS Forge talk (Thread)
3.5.17: Setting up OPCUA Client data source to another PLC OPCUA server
Last updated: 2021-11-02

In comminication Setting,how can i Add device with CAN login CODESYS Forge talk (Thread)
In comminication Setting,how can i Add device with CAN login
Last updated: 2013-03-15

Setting gateway and device ip by script not possible when executed from cli CODESYS Forge talk (Thread)
Setting gateway and device ip by script not possible when executed from cli
Last updated: 2022-04-07

Post by fless on See only variable CODESYS Forge talk (Post)
either you have "Insert with namespace" enabled in the SmartCoding options or your GVL_GLOBAL starts with {attribute 'qualified_only'} btw it's considered good practice to put the namespace in front of the variable. you could have variable with the same name in your PRG or FB.
Last updated: 2024-03-14

Post by jmfernandes on OpenDir always in error CODESYS Forge talk (Post)
Hello just to give more feedback the error I get is "ERROR_UNKNOWN :represents raw value of 5110" in File.DirOpen. The xDone never gets true, and I never get the listing of files (csv files in this case). In the hDir i get the value of 0 for a DWord!?
Last updated: 2024-07-31

Post by pablotorres on Dynamic Setting IP Address from IEC code CODESYS Forge talk (Post)
Last updated: 2024-09-30

Post by pablotorres on Dynamic Setting IP Address from IEC code CODESYS Forge talk (Post)
Last updated: 2024-09-30

Post by struccc on HTML5 Controls - string(>80) values CODESYS Forge talk (Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23

Post by corriibme on JSON Utilities and SetArray CODESYS Forge talk (Post)
Hello @florian, Could you please help with how to set an array value? I've been trying to use the with the setKeyWithArray method which creates the key with an empty array value. But I have been unable to set items in this array? objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindexx); //iValue: array[0..n] of int; Best regards
Last updated: 2024-05-11

Post by talhaali on Create an alarm list without use of Alarm config CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Create an alarm list without use of Alarm config CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by viksym on How to get the motor scaling value from code CODESYS Forge talk (Post)
Is there a way to see what value is set as the "Work travel distance per motor rotation" that is set in the Scaling menu of the axis ? I am working on my own homing function block for sensorless (hardstop) homing and I want to make it be universal between different axes with different motor's scaling for distance per rev so I need to know this value from the axis itself. I know I could do it by just creating an input variable for the function block but I'm leaving that option as a last resort.
Last updated: 2025-06-12

Post by wbj0t on one variable signed to modbus tcp server device and modbus serial device CODESYS Forge talk (Post)
Hi. Raspberry pi 4 runtime. Runtime version 4.16, IDE version 3.5.21. Is it possible write new value for variable via modbus tcp or serial devices when both enabled? As I see - not. What can I do? It is terrible restriction.
Last updated: 2025-07-17

Post by gatto on Profinet Exor connection drop CODESYS Forge talk (Post)
did you try setup two eth ? on ethO you set ip to communicate with pc, example 192.168.0.1 on eth1 ip to communicate with weidmuler I/O, example 192.168.100.1 note : ip need the same of ip setup under system setting of hmi.
Last updated: 2024-10-16

Post by rckalex on Data Source Limit CODESYS Forge talk (Post)
There appears to be a limit to the number of OPC Servers that can be connected simultaenously. 1-10 work but adding an 11th makes one of the previously linked ones unavailable. Is this a soft setting that can be adjusted? Using 3.5.18.30 on Win x64
Last updated: 2024-03-06

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
I have several libraries which contain values that should be saved on a PLC. As apparently no Persistent Variable List is available within Libraries, I use the Persistence Manager to create a Persistence Channel in the Project which imports the library. I then specify the persistence channel in the library using the {attribute 'ac_persist':='PersistenceChannel_CT'} specifier. This generally works very well and gives me exactly the properties I require. However, it came to my attention that the (alphabetially) first value from the library is not saved in the created ASCII file. When checking the content of the Persistence Channel, it shows all the variables as defined in the library. But the created file does not contain the first value and it is not restored after restart or reset. (see attached picture) I disabled Periodic Saving and set xSaveOnChange to TRUE and so the file usually updates immediately after changing one of the values. When changing the first value, it does not update which is consistent with this value not being saved. I also created a sample project and library from scratch which shows the same issue both using a Raspberry Pi and using a Linux machine. Does someone know what the reason for this could be or did someone make similar experiences? Looking forward to hearing your suggestions. Thanks in advance and best wishes Manuel
Last updated: 2023-10-17

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
This is a homing routine which is controlled by setting mode of operation and started by setting a bit in the control word. If MC_Home is not usable for this homing method then I need to implement the same functionality. But how?
Last updated: 2025-06-25

<< < 1 .. 14 15 16 17 18 .. 134 > >> (Page 16 of 134)

Showing results of 3343

Sort by relevance or date