Post by arcadium on Library ENUM text representation in visualization CODESYS Forge talk (Post)
Hello, Maybe someone could help with this. When I add ENUM to a text field I get the number instead of the text. For my own ENUM variable I have declared and enabled text list value is displayed as text, but I need enum text displayed from softMotion and other internal FB's. In the picture I have one of desired ENUM variable setup, but in the visu I have number, but in the watch window it's text. There is probably some checkbox to tick, but was looking for an hour, can't find a solution. Would apreciate some help
Last updated: 2024-12-24

Library ENUM text representation in visualization CODESYS Forge talk (Thread)
Library ENUM text representation in visualization
Last updated: 2024-12-24

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Axis references in visualization CODESYS Forge talk (Thread)
Axis references in visualization
Last updated: 2024-12-26

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Thread)
Runtime Problem connecting to Keyence IV-500MA Camera
Last updated: 2024-12-26

Post by eschwellinger on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
which plc in which version do you use?
Last updated: 2024-12-27

Post by nz-dave on Ethernet/IP Scanner Exception CODESYS Forge talk (Post)
Its Running on a Weintek CMT HMI. the program is not huge, just controlling a few pumps. plc is at 1%
Last updated: 2024-12-27

Post by nz-dave on Ethernet/IP Scanner Exception CODESYS Forge talk (Post)
see attached I don't have watchdog enabled in tasks?
Last updated: 2024-12-27

Post by nz-dave on Ethernet/IP Scanner Exception CODESYS Forge talk (Post)
3.5,18,30 The Weintek HMI Runs a dual core CPU.. one for the HMI and one "real time OS" for Running Codesys.
Last updated: 2024-12-28

Post by eschwellinger on Ethernet/IP Scanner Exception CODESYS Forge talk (Post)
which runtime version and dies this device has an realtime kernel?
Last updated: 2024-12-28

Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server CODESYS Forge talk (Post)
Ok, for the sake of completeness in case anyone else has this problem. I can tell you that what finally worked for me was to change the line: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA", 5), structAData ); to: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA|defaultbinary", 5), structAData ); I'm sure there are many other problems that could cause this very generic error, but this was my problem.
Last updated: 2024-12-30

Post by durallymax on Cannot Start Application ControlWin CODESYS Forge talk (Post)
Uninstalling and deleting all ProgramData manually, then re-installing appears to have fixed it.
Last updated: 2024-12-30

OPC UA C# client connecting to OPC UA CODESYS server CODESYS Forge talk (Thread)
OPC UA C# client connecting to OPC UA CODESYS server
Last updated: 2024-12-30

Cannot Start Application ControlWin CODESYS Forge talk (Thread)
Cannot Start Application ControlWin
Last updated: 2024-12-30

Post by micik on PLCOpenXML Export/Import with Visualisation CODESYS Forge talk (Post)
I have noticed that Codesys doesn't provide option to Export any Visualization objects even though there is option to check to export VISU_TASK, which is strange because when Import in another empty project, user will end up with build errors. I understand that probable reason for this is that PLCOpenXML specification includes only "PLC" parts of the project (POU, PRG, variable lists, device ....), but not sure about it. Perhaps, there is some option to include visu objects also in the plcopen xml export list??
Last updated: 2025-01-07

Post by jeroenaero on MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0 CODESYS Forge talk (Post)
For what it is worth taking into account on version 4.18: Softmotion 4.17 doesn't work with the SMC_TRAFO_Scara2. Very small numbers come out of dA and dB. Going back to version 4.16 solves the issues.
Last updated: 2025-01-07

Post by conny-nm on Bosch BME 280 bzw 688 Sensor per I2C Bus steuern und Daten in Codesys verarbeiten CODESYS Forge talk (Post)
Hallo Markl, gibt von Stefan Dreyer auf Git Hub Biblioteken für BMP280 und BME280, laufen aber nur in 32Bit auf dem Raspberry. BME680 kann man mit Node Red auslesen und mit mqtt zu Codesys übertragen.
Last updated: 2025-01-07

Post by aconley on Static Code Analysis CODESYS Forge talk (Post)
I know it's been a while, but I did find this: system.commands['staticanalysis','config'].execute() It opens the UI to select your settings, but I haven't figured out how to load the .CSA yet.
Last updated: 2025-01-07

MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0 CODESYS Forge talk (Thread)
MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0
Last updated: 2025-01-07

Static Code Analysis CODESYS Forge talk (Thread)
Static Code Analysis
Last updated: 2025-01-07

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Hello, I used to connect into my gateway using control SL tool 4.13, (it was called Update Linux.) I formated my computer, so today I install the new version of codesys and all package. Now I am not able to connect to my PLC using control SL. It says, check the status. Normally it used to worked perfectly before that.
Last updated: 2025-01-07

Post by eschwellinger on Not Possible to connect using control SL CODESYS Forge talk (Post)
should work, could you please check on the target: top if the the gateway is running -> you should see codesysedge.bin and cat /var/opt/codesysedge/codesysedge.log
Last updated: 2025-01-07

Post by trusty-squire on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hi, Is there a way to read the homed status from the EtherCAT drive directly? I am currently flagging the homed status on the succesful completion of the MC_Home function block, but I have had false triggers where the drive didn't actually execute the homing procedure but the MC_Home FB is marked as complete without error. I looked at other MC/SMC function blocks but the closest I can find is the "Homing" bit from MC_ReadStatus FB, but this doesn't show if the drive is succesfully homed, only that it's homing. Any guidance is welcome. Thanks!
Last updated: 2025-01-07

Post by imdatatas on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hello, I have experienced such situations with some servo drive devices in the past. The home completion information is reported to the upper controller by the slave drive with the states of the relevant bits in the StatusWord (for example; 6041h Bit10, Bit12 in Home mode). If the states of these bits are correct in terms of number and state but the motor does not actually perform the action; You can contact the slave drive manufacturer. There may be a problem with the device firmware. Another area you can play around with is looking at the settings in the "Advanced configuration" for Softmotion axis on the page the link to below, and trying it out and using the one that works for you. https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cmd_add_softmotion_cia402_axis.html A method I recommended worked for a user as in below message. https://forge.codesys.com/forge/talk/Engineering/thread/40bc82454d/ I hope your problem will be solved as soon as possible and by sharing the result here, you will help others to know and overcome it. Good luck. Best regards, Imdat