Search talk: data types int

 
<< < 1 .. 15 16 17 18 19 .. 31 > >> (Page 17 of 31)

Post by garmusd on Raspberry Pi 5 GPIO not working. CODESYS Forge talk (Post)
Hi, Codesyscontrol 4.13.0.0 Raspberry Pi5 64bit with latest updates. Cant get working GPIO - no output and no input. SPI/I2C not tested. GPIOs B+/Pi2, Input/Output is set in the parameters, assigned variables int the Mapping. Absolutely no reaction. Do I need to configure anything else to make it work? Thanks!
Last updated: 2024-09-26

Post by timvh on Converting each character to a string into ASCII CODESYS Forge talk (Post)
Nice puzzle for a Saturday afternoon :-). Here my suggestion: VAR sInput : STRING := 'R123'; byChar : BYTE; sOutput : STRING; i: INT; END_VAR sOutput := ''; IF LEN(sInput) = 0 THEN RETURN; END_IF FOR i := 0 TO LEN(sInput) - 1 DO byChar := sInput[i]; sOutput := Concat(sOutput, TO_STRING(byChar)); END_FOR
Last updated: 2024-11-09

Post by davidmic on Struct Literal CODESYS Forge talk (Post)
Hi all I want to pass a struct into a function without declaring the struct in a VAR/END_VAR. Is this possible? I think this would be called a struct literal It would look something like this someFB.write(structArgument := MyStruct#(a := 1, b := 1.2), otherArgument := TRUE); With this struct declaration TYPE MyStruct : STRUCT a : INT; b : REAL; END_STRUCT END_TYPE
Last updated: 2025-03-28

Post by benemenn on Type mappings in Datasource CODESYS Forge talk (Post)
Hi! I am trying to achieve the same issue. Has there been a solution? I can create the mapping, and map the local variable, but somehow the object does not update. Furthermore, i have an issue where codesys doesn't let me set ReadWrite accesses to the variables in the "Type Mapping" place. The access will simply not be set. Has anyone ran int that issue?
Last updated: 2025-04-02

Post by tvm on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
It will be a reference, because it's a VAR_IN_OUT. it's a little weird debugging the array online. It just shows as a POINTER TO INT, and you can't actually see the array from the function side. But you can still work with it as a normal array, not a pointer.
Last updated: 2024-01-09

Post by corriibme on JSON Utilities and SetArray CODESYS Forge talk (Post)
Hello @florian, Could you please help with how to set an array value? I've been trying to use the with the setKeyWithArray method which creates the key with an empty array value. But I have been unable to set items in this array? objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindexx); //iValue: array[0..n] of int; Best regards
Last updated: 2024-05-11

Post by talhaali on Active alarm access in ST CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Can't read Alarm Class from Alarm Storage CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Can't read Alarm Class from Alarm Storage CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Can't read Alarm Class from Alarm Storage CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Active alarm access in ST CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Alarm Manager: CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Alarm Table Issues CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Alarm status in logic CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by timvh on Active alarm access in ST CODESYS Forge talk (Post)
See https://forge.codesys.com/forge/talk/Engineering/thread/280fdf4806/#9fe5 And https://forge.codesys.com/prj/codesys-example/alarm-manager/home/Home/ The application should contain: - an FB which implements AlarmManager.IAlarmFilterCriteria (see example - FB_AlarmFilterCriteria) - an FB which implements AlarmManager.IAlarmManagerClient (see example - FB_AlarmManagerClient) Then register the client and get the information through this client. VAR xInit : BOOL := TRUE; udiResult : UDINT; fbAlarmFilterCriteriaAll : FB_AlarmFilterCriteria; fbAlarmManagerClientAll : FB_AlarmManagerClient; itfAlarmManagerClientAll : IAlarmManagerClient := fbAlarmManagerClientAll; xAlarm1 : BOOL; xAlarm2 : BOOL; xWarning : BOOL; iNrOfAlarmsInAlarmList : INT; iNrOfActiveAlarmsInAlarmList : INT; paitfAlarm: POINTER TO ARRAY [0..0] OF AlarmManager.IAlarm; iAlarmIndex : INT; eAlarmState: AlarmManager.AlarmState; END_VAR IF xInit THEN xInit := FALSE; fbAlarmManagerClientAll.m_itfAlarmFilterCriteria := fbAlarmFilterCriteriaAll; // register alarm client to get updated about alarm status / changes udiResult := AlarmManager.g_AlarmHandler.RegisterClient(itfAlarmManagerClientAll, 0, 0); END_IF // Polling the number of alarms udiResult := AlarmManager.g_AlarmHandler.GetActiveAlarms(itfAlarmManagerClientAll, parritfActiveAlarms => paitfAlarm, iCountActiveAlarms => iNrOfAlarmsInAlarmList); iAlarmIndex := 0; iNrOfActiveAlarmsInAlarmList := 0; WHILE iAlarmIndex < iNrOfAlarmsInAlarmList DO eAlarmState := paitfAlarm^[iAlarmIndex].GetState(); IF eAlarmState = AlarmManager.AlarmState.Active OR eAlarmState = AlarmManager.AlarmState.ActiveAcknowledged THEN iNrOfActiveAlarmsInAlarmList := iNrOfActiveAlarmsInAlarmList + 1; END_IF iAlarmIndex := iAlarmIndex + 1; END_WHILE
Last updated: 2025-04-23

Post by gatto on Backtick identifiers CODESYS Forge talk (Post)
Hello, I’m in Codesys 3.5.20.40 and I try to declare the variable ´var1´ but I get an error. here : https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_rules.html i read : Backtick identifiers By using backticks, characters can also be used in identifiers that are not normally permitted in identifiers, such as special characters. The acute accent character is used for backticks: ´ (Unicode: U+02CA) The use of backticks is recommended in order to be able to use the same identifiers in CODESYS as in other programming languages or documents, such as circuit diagrams. Any character may be used between two backticks, except line breaks and other backticks. Keywords are also allowed as identifiers between backticks. Examples: ´Variable+9´ ´INT´ The backticks are part of each identifier and therefore var1 and ´var1´ are two different identifiers. Example PROGRAM PLC_PRG VAR var1 : INT; ´var1´: INT; END_VAR var1 := var1 + 1; ´var1´ := 12; Are there any limitations or is something missing in my development environment?
Last updated: 2025-10-28

Post by shamcke on Array with generic constant as persistent variable CODESYS Forge talk (Post)
Hello, I have written a function block that uses a generic constant for the upper bound of an array. I wanted to have this array in the persistent memory area, thus I constructed my FB as follows: FUNCTION_BLOCK FbWithGenericArrayLength VAR_GENERIC CONSTANT uiArrayLength : UINT := 10; END_VAR VAR PERSISTENT arr : ARRAY[1..uiArrayLength] OF INT; END_VAR In my PLC_PRG I declare an instance of said FB PROGRAM PLC_PRG VAR myFb : FbWithGenericArrayLength<10>; END_VAR This compiles just fine. When I let CODESYS fill my persistent list, it adds duplicate entries {attribute 'qualified_only'} VAR_GLOBAL PERSISTENT RETAIN // Generated instance path of persistent variable PLC_PRG.myFb.arr: ARRAY [1..uiArrayLength] OF INT; // Generated instance path of persistent variable PLC_PRG.myFb.arr: ARRAY [1..uiArrayLength] OF INT; END_VAR so I manually delete the duplicate. When i now compile, I get errors ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... [ERROR] Sandbox_FW31: PersistentVars [Device: PLC Logic: Application](Line 4): C0161: Border 'uiArrayLength' of array is no constant value [ERROR] Sandbox_FW31: PersistentVars [Device: PLC Logic: Application](Line 4): Type of mapped variable is not equal to original type Compile complete -- 2 errors, 0 warnings Build complete -- 2 errors, 0 warnings : No download possible Is is simply not possible to use a generic constant for the persistent array? Thanks in advance. Edit: It seems I can manually replace the uiArrayLength in the persisten list by the value 10 I used as the generic constant for this particular instance.
Last updated: 2026-05-29

Post by mase on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Hi, sorry I can´t help you with your issue, but I hope you can give me a hint on getting GUID for other objects than POUs. Your code states "Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08")". We can I find the GUID / ObjectIds`? I wasn´t able to get details about the GUID of DataTypes (STRUCT/ENUM,..)m, Functions (FUN), GLOBALS and TYPES. I want to create markdown of all available project elements. Thanks for your help
Last updated: 2024-08-06

Post by pjoret on IFM CR711S Can Low Level Library Use CODESYS Forge talk (Post)
Hello, I'm using CR711S from IFM and I would like to use the CAA Can Low Level in de Safety part. I already use it on the Standard part and it works properly. I would like to know if there is some restriction on using it on the safepart of the PLC (I tried but my PCL put himself in Stop...) ? And if you have some example or even a forum with some types on IFM and CoDeSys, I would Take It. Have a nice Day.
Last updated: 2024-04-03

Post by engrahman on The current baud rate could not be determined in CR0020 IFM with maintenance tool CODESYS Forge talk (Post)
Hello everyone, im working with IFM CR0020 controller via RS232 protocol where im trying to connect it to my PC but, every time when im using the maintenance tool to identify the device i get the error "The baud rate could not be determined" i have tried to change the cable of RS232 with different types but the error presist, any idea how to fix it
Last updated: 2024-05-21

Post by lepewe4ka on Sysmac Studio to Codesys CODESYS Forge talk (Post)
Could you send me an example? I would like to generate a data structure using XML files.
Last updated: 2023-09-20

Post by lepewe4ka on Sysmac Studio to Codesys CODESYS Forge talk (Post)
Could you send me an example? I would like to generate a data structure using XML files.
Last updated: 2023-09-20

Post by vladimirsmall on Send data to USB CODESYS Forge talk (Post)
Hello/ Need send some file ( for example Array of string) to USB. Which library need used for this. Thank you
Last updated: 2024-07-20

Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager CODESYS Forge talk (Post)
After 3 hours is some progress - please find in attachment - progress1.jpg
Last updated: 2024-09-04

Post by lsislsis on RPI Serial port connects with no errors but not data being transmitted or received CODESYS Forge talk (Post)
Is there any solution because we have the same problem with other hardware?
Last updated: 2024-09-30