Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Hello, I used to connect into my gateway using control SL tool 4.13, (it was called Update Linux.) I formated my computer, so today I install the new version of codesys and all package. Now I am not able to connect to my PLC using control SL. It says, check the status. Normally it used to worked perfectly before that.
Last updated: 2025-01-07

Post by eschwellinger on Not Possible to connect using control SL CODESYS Forge talk (Post)
should work, could you please check on the target: top if the the gateway is running -> you should see codesysedge.bin and cat /var/opt/codesysedge/codesysedge.log
Last updated: 2025-01-07

Post by trusty-squire on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hi, Is there a way to read the homed status from the EtherCAT drive directly? I am currently flagging the homed status on the succesful completion of the MC_Home function block, but I have had false triggers where the drive didn't actually execute the homing procedure but the MC_Home FB is marked as complete without error. I looked at other MC/SMC function blocks but the closest I can find is the "Homing" bit from MC_ReadStatus FB, but this doesn't show if the drive is succesfully homed, only that it's homing. Any guidance is welcome. Thanks!
Last updated: 2025-01-07

Post by imdatatas on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hello, I have experienced such situations with some servo drive devices in the past. The home completion information is reported to the upper controller by the slave drive with the states of the relevant bits in the StatusWord (for example; 6041h Bit10, Bit12 in Home mode). If the states of these bits are correct in terms of number and state but the motor does not actually perform the action; You can contact the slave drive manufacturer. There may be a problem with the device firmware. Another area you can play around with is looking at the settings in the "Advanced configuration" for Softmotion axis on the page the link to below, and trying it out and using the one that works for you. https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cmd_add_softmotion_cia402_axis.html A method I recommended worked for a user as in below message. https://forge.codesys.com/forge/talk/Engineering/thread/40bc82454d/ I hope your problem will be solved as soon as possible and by sharing the result here, you will help others to know and overcome it. Good luck. Best regards, Imdat
Last updated: 2025-01-08

Post by bruno-roth on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hello, the information if your axis is already homed you could only find out direct from your Slave. In DS402 status there is no Bit defined. But some manufacturer of Drives use some optional bits or status. E.g. if you have Schneider Electric LXM32 Servo you will find this information in Bit 15. You have to check the manual of your used Servo-Drive f this information is provided in any object and then read it out with SDO.
Last updated: 2025-01-08

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
Hi, When trying to activate a control Basic L license on a Wago PFC200 750-8203 the error The selected container ... does not fit your ticket comes up and won't allow licensing. I have deleted the /var/opt/codesys/cmact_license/ content 3 times and the container number changed each time after a reboot, but the problem persists. Not a happy first time experience with those weird application based licenses. IDE is 19.20. This was a e!Cockpit FW22 PLC and I used Deploy Control SL to make the green web interface red. WBM shows Codesys 2 and e!Runtime active which is a bit weird. What do I do now? Regards Heinz
Last updated: 2025-01-08

Post by hboertz on CamBuilder and first boundary position not zero CODESYS Forge talk (Post)
Hi @niallel, it is currently not possible to create periodic cams using SMCB.BoundImplicit(). If you want to create a periodic cam which does not start/end with all slaves values equal to zero, then you must specify the boundary conditions explicitly using SMCB.Bound(). When you finished your cam, you can check via CamBuilder.CheckContinuity(), if the cam fulfills the continuity requirements for a periodic cam (see input isPeriodic). But you are right, it should be possible to create periodic cams using implicit boundary conditions. I have added the following Jira issue, so that this feature might be included in a future SoftMotion version: SM-5537: CamBuilder: It should be possible to create periodic cams using implicit boundaries I hope this answers your question. Best regards, Hendrik
Last updated: 2025-01-08

CamBuilder and first boundary position not zero CODESYS Forge talk (Thread)
CamBuilder and first boundary position not zero
Last updated: 2025-01-08

Post by lanouar on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
I'm also having the same problem with raspberry 4
Last updated: 2025-01-08

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
Don't I need a browser on the device for web depot? Could work on the Pi but not the Wago controller. Maximum I have is SSH.
Last updated: 2025-01-08

Post by yannickasselin on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
Not sure this will help you but I had the same issue and was able to activate the license on a Windows PC using the Web Depot in a web browser. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_installing_license.html
Last updated: 2025-01-08

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
Update, installed 3.5.19.70 with the same result. The error message is as useful as a chocolate fire guard. The container SN is in the 130-xxx range which should work. The Version, Chip, Rev number don't mean anything to me. There is no SD Card installed. I've also reinstalled a fresh Wago FW22 image, Deployed PFC200 SL and Edge for Linux, still the same result.
Last updated: 2025-01-09

Post by smartcoco on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
I have the same problem, it seems like there is no solution.
Last updated: 2025-01-09

Post by thomas-moba on app file renamed as err. file CODESYS Forge talk (Post)
Hello, we have the same problem. What is it all about?
Last updated: 2025-01-09

app file renamed as err. file CODESYS Forge talk (Thread)
app file renamed as err. file
Last updated: 2025-01-09

Post by timvh on PLCOpenXML Export/Import with Visualisation CODESYS Forge talk (Post)
A Task is a standard IEC 61131-3 object, so logically that you can export the VISU_TASK. A visualization is no standard IEC 61131-3 object, so not compatible with other IEC tools. Just use the standard export / import functionality. These files are not IEC compatible and can only be used in CODESYS. But these do support visu objects.
Last updated: 2025-01-09

Library ENUM text representation in visualization CODESYS Forge talk (Thread)
Library ENUM text representation in visualization
Last updated: 2025-01-09

Post by micik on PLCOpenXML Export/Import with Visualisation CODESYS Forge talk (Post)
Thanks Tim, I suspected this is the reason, but want to confirm this.
Last updated: 2025-01-09

Colors look different when logged in and running CODESYS Forge talk (Thread)
Colors look different when logged in and running
Last updated: 2025-01-09

PLCOpenXML Export/Import with Visualisation CODESYS Forge talk (Thread)
PLCOpenXML Export/Import with Visualisation
Last updated: 2025-01-09

Post by timvh on Colors look different when logged in and running CODESYS Forge talk (Post)
At the top of the Visualisation Properties View, you can enable the "Advanced" options. This will give you access to more properties than what you currently see. There might be a variable linked to the "advanced" colour property where the fill colour is determined by the value of this variable (dword).
Last updated: 2025-01-09

Post by timvh on Library ENUM text representation in visualization CODESYS Forge talk (Post)
Probably the enum from the library doesn't have text support. In that case you need to add your own TextList to the application. In the rectangle you should use the property "dynamic text" to link this object to the textlist which you have created yourself and then link the text index to your enum variable.
Last updated: 2025-01-09

Post by mattplc on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
Same for me. I have problems with UAExpert too. Can't see the Current Value of Enum and can't control. Did some Tests with Python opcua library. Not working with the communication manager so far.
Last updated: 2025-01-09

Post by mattplc on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
Same for me. I have problems with UAExpert too. Can't see the Current Value of Enum and can't control. Did some Tests with Python opcua library. Not working with the communication manager so far.
Last updated: 2025-01-09

Post by mattplc on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
Same for me. I have problems with UAExpert too. Can't see the Current Value of Enum and can't control. Did some Tests with Python opcua library. Not working with the communication manager so far.
Last updated: 2025-01-09