Post by talhaali on Alarm status in logic CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by vitorp on Visualization Toolbox in German CODESYS Forge talk (Post)
Hello, I am new to Codesys. I installed it on my computer and set the language to English. Most of the localized text appears in the correct language, but the Visualization Toolbox and the element properties are in German. I haven't found a way to change them to English. Can someone help me with this?
Last updated: 2024-06-17

Post by calviniscoding on Publish a JSON payload via MQTT Publish (using IIot Libraries) CODESYS Forge talk (Post)
Are you able to dynamically change the JSON message? As in, if wsValue or iValue is linked to some real telemetry that varies over time, will the JSON message reflect these changes? I am only able to send the values that I initialize the JSON message to
Last updated: 2024-06-18

Post by koppit on SysComRead Timeout Parameter CODESYS Forge talk (Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
for the package you net to install 32bit support(to have the native timprovider availble to deploy) sudo apt-get install libc6:i386 Then native Safeplc and native Safetimeprovider should be available to install. Raspi yes - but there is no official package available till now and you need have a rt_preemt patched kernel on the Pi, then it works like charm
Last updated: 2025-11-18

Post by osande on Trend/trace data CODESYS Forge talk (Post)
Ok, the problem is that the trend/trace system can't read function block instance data. The variables has to be stored directly under the program calling the FBs. Thus, FB variables to be trended/traced must be connected to variables declared in the program. Seems like a bug to me!
Last updated: 2026-03-13

Runtime πŸ‡¬πŸ‡§ CODESYS Forge talk (Discussion)
Related questions to SoftPLCs e.g. Raspberry Pi, Beaglebone, IoT2000 and other platforms
Last updated: 6 days ago

Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess) CODESYS Forge talk (Post)
I run CODESYS runtime as a service and use CmpLog (the LogAdd2 function) to log different events to a file. I have done this many times before on various projects and hardware, and it works fine. On this particular system, I have CODESYS 3.5.20.40 running on a Windows 11 PC. The CODESYSControlService autostarts (with Local System credentials, the default), and the application runs fine. However, the configuration file is not read (or at least not the one that should be, or not the CmpLog section), and log files are not written to the disk. I would be thankful if anyone knew why this is happening and how to fix it. A note to CODESYS people: you must provide more information on the codesys configuration file, CODESYSControlService.exe and other major components and system behaviour. You created the service and various features (i.e. logging), but haven't explained how they work, which, in my opinion, is below standard for industrial automation software. These are my observations: - When running as a service, the config file is not read (none of them), or at least the CmpLog section is not read. I checked the log using Codesys IDE, and the CmpLog parameters are not the ones I have set in any of the config files. Which CmpLog config values does the service use, and where does it read them from? I have no idea, but it's not the config files. Here are the codesys config files I located on the PC's disk: o C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\CODESYSControl.cfg (only 2 lines in this config) o C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\AppDataFiles\CODESYSControlWinV3\CODESYSControl.cfg o C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg o C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\tempCFG\CODESYSControl.cfg - When I run codesys as an app (e.g. by clicking the icon), this config file is read C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg and log files are written ok. The icon target is "C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\CODESYSControlService.exe" -d o the -d option, I think, starts a cmd-like window showing service debug output (the output shown in log in the IDE) o the -i option, again I think, means install the service - I tried adding -d to service start parameters in the registry, but it started only once and after that it refused to start. Knowing what -d does and which other options are available would be great (e.g. can I make the service read a different config file). - Syslog UDP logging works fine in any case. - These are my CmpLog parameters ~~~ [CmpLog] Logger.0.Name=PlcLog3 Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=10003 Logger.0.MaxFileSize=50003 Logger.0.MaxFiles=33 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314 ;Set the timestamp to RTC ~~~
Last updated: 2025-02-27

Post by arvind on communication CODESYS Forge talk (Post)
HI All past two weeks im trying to configure and establish communication between wago rs485 fieldbus coupler(750-315/300-000) with wago pfc 200 plc but not able to communicate can you peoples help me to configure and establish communication using codesys v3.5 and above
Last updated: 2023-08-19

Post by eschwellinger on Connection to device closed CODESYS Forge talk (Post)
is there a way to check the plclog on Opus A3 by using cmd line under Linux? This log is what you need to check for the disconnection problem
Last updated: 2023-08-24

Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
Thank you for the return. The path targets to a CFast card. User has R/W access to it. We will try to change it.
Last updated: 2023-08-31

Post by jinil on Import RsLogix 5000 project to Codesys CODESYS Forge talk (Post)
Hello, I am trying to do the same thing. I want my Rslogix 5000 project into Codesys. Was wondering if you have found a way to do it. Thank you.
Last updated: 2023-09-07

Post by jinil on Import RsLogix 5000 project to Codesys CODESYS Forge talk (Post)
Hello, I am trying to do the same thing. I want my Rslogix 5000 project into Codesys. Was wondering if you have found a way to do it. Thank you.
Last updated: 2023-09-07

Post by wehling-h on Troubles with using CAN API CODESYS Forge talk (Post)
Hi together, I'm using a 11bit driver system which seems to work well so far. May someone here knows if i have to configure a singleID for each message i like to receive and evaluate?
Last updated: 2023-09-11

Post by maralani on Retain memory change to ZERO CODESYS Forge talk (Post)
Hi, thanks for help, I add some retain variable , then some other variable change to zero , andI was not able to change the value
Last updated: 2023-09-19

Post by chris12345 on Calling OPC UA Methods from UaExpert CODESYS Forge talk (Post)
Hi, Is it possible to generate an .xml file with FBs and methods from Codesys? Or do I need a separate program to generate the .xml file? Or is there a otherway to use methods via opc ua from the own project?
Last updated: 2023-09-20

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Thank you very much so far - As I finaly decided to make an update on the PFC200 - as I've to get it up and running again. But something failed there and no I'm having an other Problem :-( I'll come back to this, when the error comes back!
Last updated: 2023-09-28

Post by sturmghost on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs CODESYS Forge talk (Post)
You could work around this problem by implementing some sort of "state machine". Each dialog sets a boolean variable when they are closed so you know which dialog was closed. Then you can react to this accordingly.
Last updated: 2023-10-01

Post by aott33 on Webvisu NO load CODESYS Forge talk (Post)
I put in a support ticket request for this issue since I need this application to be running reliably for my customer's application. Hope to hear back from support soon to troubleshoot this process.
Last updated: 2023-10-09

Post by lhohmann on EtherNet_IP_Scanner - No driver found CODESYS Forge talk (Post)
I've managed to run Ladder logic code on a virtual PLC running on my laptop. Now, I want to connect to a device over EthernetIP, but I always get the "No driver found" message. Can anyone shed me some light?
Last updated: 2024-07-02

Post by naks on Dynamic Setting IP Address from IEC code CODESYS Forge talk (Post)
Hi everyone, I was able to change the IP address of my Controller (wago 750-8212), but when i restart my Controller then the IP address resets to the original, are there any other settings i need to implement?
Last updated: 2024-07-08

Post by brzozka100 on Change modbus server parameters from program CODESYS Forge talk (Post)
Hello, is there a possibility to change modbus server parameters (baud rate, parity, etc.) configured in devices tree from PRG? I need to be able to change them, for example, from HMI.
Last updated: 2024-07-16

Post by brzozka100 on Change modbus server parameters from program CODESYS Forge talk (Post)
Hello, is there a possibility to change modbus server parameters (baud rate, parity, etc.) configured in devices tree from PRG? I need to be able to change them, for example, from HMI.
Last updated: 2024-07-16

Post by kevinjordan on C0244: No VAR_PERSISTENT list is part of the application to enter instance path for variable CODESYS Forge talk (Post)
Do you still have this image, or can you tell me where I need to click to enable persistant variables? I'm getting the same error:C0244: No VARPERSISTENT
Last updated: 2024-07-17

Post by ibarragerman on PLCHandler where is it CODESYS Forge talk (Post)
Hello, someone has some example to use PLC Handler? Without SDK. I would like to make some test before to go forward buying SDKs.
Last updated: 2024-07-26