Post by timvh on Colors look different when logged in and running CODESYS Forge talk (Post)
At the top of the Visualisation Properties View, you can enable the "Advanced" options. This will give you access to more properties than what you currently see. There might be a variable linked to the "advanced" colour property where the fill colour is determined by the value of this variable (dword).
Last updated: 2025-01-09

Post by winki on Warning attribut no_assign CODESYS Forge talk (Post)
Hello, I have two warning on my code, and I would like to understand why. C0540: Attribut 'no_assign' missing for the 'FB_MOdbusReadHolding'. The type of the variable clientTcp is set to 'no_assign'. In this FB, I have done: clientTcp : ModbusFB.ClientTCP; clientRequest : ModbusFB.ClientRequestReadHoldingRegisters; The error comes from clientTcp : ModbusFB.ClientTCP; I am using ModbusFB 4.4.0.0. Thx a lot
Last updated: 2025-01-10

Post by winki on Warning attribut no_assign CODESYS Forge talk (Post)
Hello, I have two warning on my code, and I would like to understand why. C0540: Attribut 'no_assign' missing for the 'FB_MOdbusReadHolding'. The type of the variable clientTcp is set to 'no_assign'. In this FB, I have done: clientTcp : ModbusFB.ClientTCP; clientRequest : ModbusFB.ClientRequestReadHoldingRegisters; The error comes from clientTcp : ModbusFB.ClientTCP; I am using ModbusFB 4.4.0.0. Thx a lot
Last updated: 2025-01-10

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
It's suspected that the CPU loading is the Linux Kernal in the Wago PFC200 dealing with IGMP multicast traffic (@ 250 uSec) from inverters on site. The inverters use the ethernet network and IGMP to synchronize, the customer removed the switch that shipped with the system, and thus removed IGMP Snooping that was plug-and-play within the provided switch.
Last updated: 2025-01-24

Post by helcioburd on How long can a WSTRING be in CodeSys V3? CODESYS Forge talk (Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02

Post by cellohorst on File Creation Issue CODESYS Forge talk (Post)
Nope! The file path is $$PlcLogic$$ and NOT $$PLCLogic$$. Otherwise a new folder ('PLCLogic') is created (at least with a linux rt - like raspberry or compute module) with the new file in it if you open the file with eFileMode := FILE.MODE.MRDWR. That is a bad bug that I'll report right after this comment.
Last updated: 2025-03-03

Post by jkopicz on How can you get the active frame index from a frame CODESYS Forge talk (Post)
In my project, I have frames that I would like to read the current active index. I change the frame index using the onclick properties of a button, then change frame index. I need to do some logic based on which frame index is selected. Is there a way to read the current active index of a frame?
Last updated: 2025-03-11

Post by peterkcontrols on Making a Visu Element normally invisible and visible if variable is true CODESYS Forge talk (Post)
Hello I would like an element in my visu to be only visible when a certain Variable is true, currently it is only capable of being normally visible and then invisible if a certain variable is true. Is this possible without programming a new variable to be the opposite of my desired control variable? Thanks.
Last updated: 2025-03-12

Post by trusty-squire on SysProcessCreate2 on Linux runtime CODESYS Forge talk (Post)
Hi, I'm trying to launch a continuously running python script from Codesys and monitor the script status inside the Codesys runtime (running on a Linux enviroment). For now I'm testing with the below to emulate a continuously running Python script: #test.py i = 0 while True: i += 1 I'm able to successfully run the script using SysProcessExecuteCommand2 (I can see the Python process running in the task manager). However, this "freezes" the Codesys execution of the task - it sits on that command and will not continue until the Python script ends. I've proven this works by using the task monitor to kill the process, then Codesys continues on happily through the task. What I want to do is use SysProcessCreate2 to set up the Python script as a background task and monitor the process using SysProcessGetState. This always results in the error "ERR_OPERATION_DENIED". I know that I'm able to execute commands (as above), so my config should be correct. Is SysProcessCreate2 functional on a Linux environment? Is there something in the config file I'm missing? Here's my "working" code that uses SysProcessExecuteCommand2: VAR bTest : BOOL; sCommand : STRING := '/usr/bin/python3 /var/opt/codesys/PlcLogic/Application/test.py'; refCommand : REFERENCE TO STRING REF= sCommand; sOutput : STRING; refOutput : REFERENCE TO STRING REF= sOutput; result : RTS_IEC_RESULT; END_VAR IF bTest THEN SysProcessExecuteCommand2( pszCommand:= refCommand, pszStdOut:= refOutput, udiStdOutLen:= SIZEOF(sOutput), pResult:= ADR(result) ); bTest:= FALSE; END_IF And here's the code that always results in the ERR_OPERATION_DENIED error: VAR bTest : BOOL; sApp : STRING := '/usr/bin/python3'; sCommand : STRING := '/var/opt/codesys/PlcLogic/Application/test.py'; refApp : REFERENCE TO STRING REF= sApp; refCommand : REFERENCE TO STRING REF= sCommand; hResult : SysProcess.RTS_IEC_RESULT; hHandle : SysProcess.RTS_IEC_HANDLE; END_VAR IF bTest THEN hHandle := SysProcessCreate2( pszApplication:= refApp, pszCommandLine:= refCommand, ulFlags:=SYSPROCESS_CREATEFLAG_HIDDEN, pResult:= ADR(hResult) ); bTest:= FALSE; END_IF Here's the relevant section from the config file at /etc/codesyscontrol/CODESYSControl.cfg: [SysProcess] Command=AllowAll Appreciate any support or ideas. Thanks!
Last updated: 2025-03-16

Post by hassaank on CODESYS V3+ WAGO PFC200+ MODBUS RTU CODESYS Forge talk (Post)
Hi everyone, I’m new to CODESYS and Wago devices, and I’m trying to set up Modbus RTU communication. I have a Wago PFC200 (8110) and a 750-653 RS485 module, and I want to read data from an energy meter using Modbus RTU. Thanks in advance for your help!
Last updated: 2025-03-17

Post by elektron785 on GPIO mit Codesys Virtual Control for Linux ARM64 SL CODESYS Forge talk (Post)
Hallo zusammen, ich möchte an einem Entwicklungsboard auf dem der i.MX 8M Plus von NXP aufgesteckt ist die vier zur Verfügung gestellten GPIOs als Ausgänge verwenden. Ich habe mir dazu die Readme-Datei des GPIO-Beispiels von "C:\Program Files\CODESYS 3.5.20.40\CODESYS\CODESYS Control SL Extension Package\4.14.0.0\Examples\GPIO" angeschaut Die Übersicht der verfügbaren GPIOs sieht folgendermaßen aus - wobei ich das auf die reduziert habe, die für mich von Interesse sind: gpiochip0: GPIOs 0-31, parent: platform/30200000.gpio, 30200000.gpio: gpio-0 (SODIMM206 ) gpio-1 (SODIMM208 ) gpio-2 ( ) gpio-3 ( ) gpio-4 ( |sd-vsel ) out hi gpio-5 (SODIMM210 ) gpio-6 (SODIMM212 ) gpio-7 (SODIMM216 ) gpio-8 (SODIMM218 ) gpio-9 ( ) gpio-10 ( ) gpio-11 (SODIMM16 ) gpio-12 (SODIMM155 |regulator-usb1-vbus ) out lo gpio-13 (SODIMM157 ) gpio-14 (SODIMM185 |regulator-usb2-vbus ) out hi gpio-15 (SODIMM91 )** Füge ich nun das GPIO (1 Bit)-Gerät in meinem Codesys-Programm hinzu funktioniert der Bus solange bis ich die Richtung in den GPIO-Parametern von "not used" auf "Output" stelle (siehe Bild gpio_parameter). Dann funktioniert nach Download der Bus nicht mehr. Gibt es noch eine andere Möglichkeit das zu steuern oder muss ich noch Einstellungen tätigen? Für die Zeile mit dem echo (export/unexport) aus dem Beispiel fehlen mir trotz sudo die Zugriffsrechte. "The Kernel Linux has deprecated GPIO user space SysFS. However, the kernel config CONFIGGPIOSYSFS is still enabled on Toradex's BSP to support customers using it in their legacy applications. You can check the configuration by running zcat /proc/config.gz | grep CONFIGGPIOSYSFS. For GPIO access from userspace, the new char device API, also known as libgpiod, must be used." Dies steht in der Verwendung der GPIOs - eine Ausführung des zcat-Kommandos liefert ein =y zurück.
Last updated: 2025-03-17

Post by davidmic on Struct Literal CODESYS Forge talk (Post)
Hi all I want to pass a struct into a function without declaring the struct in a VAR/END_VAR. Is this possible? I think this would be called a struct literal It would look something like this someFB.write(structArgument := MyStruct#(a := 1, b := 1.2), otherArgument := TRUE); With this struct declaration TYPE MyStruct : STRUCT a : INT; b : REAL; END_STRUCT END_TYPE
Last updated: 2025-03-28

Post by jba-eltech on Moving Frames CODESYS Forge talk (Post)
Hello everyone. I am using Codesys and saw in a YouTube video on the Codesys channel (https://www.youtube.com/watch?v=y_l2siXY7dA) that you can create frames and move them with the mouse. However, the video does not show how to do this. Can someone please explain it to me? Thank you very much.
Last updated: 2025-04-01

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Thank you for your answer! I know that 0 will be the end of the string. I checked it. There is no 0 in array of bytes. I made screenshots. There is array of bytes, aborted string and the result of my test via online converter.
Last updated: 2025-04-02

Post by mucleus on How do I fix ";Internal Error (x86-64): Invalid type size" error? CODESYS Forge talk (Post)
I opened the project file of version 3.5.19.7 in 3.5.21.0. I updated all the environment of the project to the latest and compiled it. When I compile it, I get an error ";Internal Error (x86-64): Invalid type size". How can I fix this error? I will wait for your help.
Last updated: 2025-04-15

Post by snguyen on Atomic and Shared memory? CODESYS Forge talk (Post)
Hi, I've read that you can perform Atomic instructions like AtomicReadLInt on variables. However, I'd like to know if this uses stdatomic internally. My main question is : Is it possible to share atomic types in shared memory with CodeSys. If so, what types should they be declared as? If not, are the atomic functions lock-free or does it use a mutex?
Last updated: 2025-04-15

Post by atone on Change IO-Link Device Interface connected to a Profinet-Slave at Runtime CODESYS Forge talk (Post)
OK, I figured out that I can simply define all the sensors as 16 bytes IN/OUT, even if they are not all used. EDIT: The negative effect is that each bit is taken into account as an I/O for the license, even if not used.
Last updated: 2025-04-28

Post by ellocco on Kann mich nicht am Gerät anmelden CODESYS Forge talk (Post)
Nachdem ich einige Zeit unbehelligt arbeiten konnte, bin ich wieder ausgesperrt, Deinstallieren und Neuinstallation der Nachfolgeversion (SP21) hat nichts gebracht und der Trick, der unter SP18 funktioniert ist mittlerweile verbaut (wie bereits geschrieben). Gibt es evtl. in der Registry einen Ort, an dem ich etwas löschen muss / modifizieren kann?
Last updated: 2025-05-09

Post by nano on Creating, using an external Function. CODESYS Forge talk (Post)
the Answer is easy, you don't reapecting the codesys-behaviour and pre-request on a dll/so like you like to create. codesys won't load it about the fact that the dll isn't registered in codesys. check this page for more informations: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_extension_extension_sdk.html
Last updated: 2025-05-14

Post by fionexyan on Codesys Installation Always Freeze when the installing is almost done CODESYS Forge talk (Post)
Hello Everyone , I have try in repeatedly with uninstall and reinstall the Codesys software and even turn-off the antivirus application before implement to reinstall the codesys ,but at the consequence the problem still same although go with such method, therefore is there any solution for this issue . Thank You .
Last updated: 2025-05-16

Post by edson-bueno on SysProcess Execute Command unable to run commands with special characters CODESYS Forge talk (Post)
Hi, I found the same issue, and I fixed with this steps: 1st go to codesys .cfg file. sudo nano CODESYSControl.cfg Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll Now we need to grant codesys root rights on Linux. Step 1: Create or edit the systemd override configuration: sudo systemctl edit codesyscontrol In the editor that opens, insert: [Service] User=root Save and exit: Press Ctrl+O to save Press Ctrl+X to exit Step 2: Reload systemd and reboot To apply the override: sudo systemctl daemon-reexec sudo systemctl daemon-reload sudo reboot Step 3: Confirm CODESYS is running as root After reboot, open the terminal and run: ps aux | grep codesyscontrol You should see something like: root 1234 ... /opt/codesys/bin/codesyscontrol.bin ... If instead it shows admin or another user, the override was not applied correctly. Step 4: (Optional) Confirm from within CODESYS In your CODESYS project, insert this test code to run the Linux command whoami: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR refCommand REF= sCommand; refOutput REF= sOutput; SysProcessExecuteCommand2( pszCommand := refCommand, pszStdOut := refOutput, udiStdOutLen := SIZEOF(sOutput), pResult := ADR(resultCmd) ); Notes & Warnings This method gives full system access to the CODESYS runtime — do not expose this system to the public network without protection. Do not use sudo in commands inside CODESYS when the runtime is already running as root. @tomas111, in case you want to read the temperatur, use this command: sCommand:STRING:='/usr/bin/vcgencmd measure_temp';
Last updated: 2025-05-20

Post by lbouchard on CANOpen SIL2 error: UNSAFESTACK_NOT_OPERATIONAL CODESYS Forge talk (Post)
Hello, Working in 3.5 SP11 32 bit and using the 3S CANopenSafety Slave 3.5.11.0 library on an IFM CR711S. The 3SCSSD.CANOpenDevicesSIL2 function block keeps throwing "UNSAFESTACK_NOT_OPERATIONAL" Additionally, the Status of the device gives "There was an error accessing an I/O parameter". Any ideas on where my issues may lay? I have not found any good documentation that would explain the issue.
Last updated: 2025-05-23

Post by selim on LS ix7nh Servo drive with Codesys CODESYS Forge talk (Post)
Hello Mr./Ms., I do not find the ES driver in codesys. The setup of the project is "Rasberry PI3B>Ls ethercat I/O aps-ec-dt32k> LS ix7nh Servo drive>apmc-fbl04amk LS servo motor". How can i slove this problem. Please provide me a proper solution.
Last updated: 2025-06-02

Post by nano on CoDeSys V3.5.19.7 Code erzeugen dauert extrem lange CODESYS Forge talk (Post)
da kenne ich einige Ursachen: - Antimalwareserviceexecutable - Projekt liegt am Netzlaufwerk - Projekt liegt in OneDrive - Die Festplatte ist voll - Arbeitsspeicher ist voll - Netzwerkanbinding ist mangelhaft - Windows-Update ist fehlerhaft oder es steht noch ein Neustart aus Das sind so die am häufigsten auftrettenden Probleme im Zusammenhang mit dem verhalten. Ab und an hilft auch eine Neuinstallation von Codesys
Last updated: 2025-06-09

Post by imdatatas on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Hi, You can give a try it by adding "Codesys.exe" in the "Exclusions > Process" section of the Windows Security Center or your antivirus program. I hope it works for your situation. Antivirus programs check many things during both the installation or startup of an application, and may be slow down or block some functions. Regards Imdat
Last updated: 2025-06-25