Post by imdatatas on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR] CODESYS Forge talk (Post)
Dear @gseidel, Thank you for your reply. The exact version of Codesys and its compiler was 3.5.21.20. The compiler version was fixed and could not be changed in project settings. Since I couldn't continue due to this compilation error, I temporarily overcame this issue as follows. -- I completely uninstalled Codesys 3.5.21.20 and completely deleted the Codesys folder in the C:\ProgramData folder. -- I restarted my computer and installed Codesys 3.5.19.70. -- I updated the Codesys Installer and all its add-ons to the latest versions. -- The project that was giving me the compilation error I mentioned before is now open with Codesys 3.5.19.70, compiled it, and successfully downloaded it on the device. -- I haven't encountered the same problem anymore. I think this issue is related to SP21 and its compiler. Frankly, I'd expect a project created with an older version to compile without errors after opening it with the latest Codesys version and updating all libraries. Regards, imdatatas
Last updated: 2025-09-26

Post by vipul on Multicast udp CODESYS Forge talk (Post)
Hi, Good afternoon can anybody help me with UDP Multicast code. I am not able to send or recieve data when code is dumped on linux device. Below is my code. Declaration: PROGRAM udp_multicast VAR oneTimeFlag :UINT :=0; state: INT:=0; driver: UDP.UDPDriver; //port : UDP.Port;//moved to GVL src_ipAddr_ud: UDINT; src_ipAddr_st:STRING := '192.168.127.155';//'192.168.1.155';//ipms ip address dst_ipAddr_ud:UDINT; group_ipAddr_st:STRING := '239.1.5.10'; //group_ipAddr_ud:UDINT; result: SysTypes.RTS_IEC_RESULT; //result of recieve function. bind: UDINT; //result of binding. resultCreate:SysTypes.RTS_IEC_RESULT;//result of port creation. timer:BLINK; temFlag :INT:= 0; post:INT :=0; checksumFunc:checksumXor; localStringBuf:STRING[500]; chksum:BYTE; dataBuffer:POINTER TO BYTE; checksumString:ARRAY[0..5] OF BYTE; recvSize:__XINT; errorCode:UDINT; joinGroupErrorCode:UDINT; END_VAR ************8 Implementation: IF oneTimeFlag <> 1 THEN oneTimeFlag:=1; resultCreate := driver.CreatePort(ADR(GVL.port)); src_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIPAddress:= src_ipAddr_st); GVL.group_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIpAddress:= group_ipAddr_st); GVL.port.IPAddress := src_ipAddr_ud; GVl.port.ReceivePort:= GVL.src_port;//port on which messages are expected. GVl.port.SendPort := GVL.dest_port; GVl.port.OperatingSystem := 0; //0- any system GVL.port.Socket :=3; //3- socket type is multicast bind := GVL.port.Bind(udiIPAddress:=src_ipAddr_ud,); GVl.port.JoinGroup(udiGroupAddress:= GVL.group_ipAddr_ud,udiInterfaceAddress:= src_ipAddr_ud,eLogCode=>joinGroupErrorCode); END_IF timer(ENABLE:=TRUE,TIMELOW:=T#100MS,TIMEHIGH:=T#100MS); IF timer.OUT = TRUE THEN GVL.port.Send(udiIPTo:=GVL.group_ipAddr_ud,GVL.dest_port,pbyData:=ADR(GVL.writeData),diDataSize:=SIZEOF(GVL.writeData)); ELSE SysMemSet(ADR(GVL.readData[0]),0,SIZEOF(GVL.readData)); result := GVl.port.Receive(ADR(GVL.readData),diDataSize:=SIZEOF(GVL.readData),udiIPFrom=>dst_ipAddr_ud,diRecvSize=>recvSize,eLogCode=>errorCode); SysMemMove(ADR(GVL.readDataBuf[0]),ADR(GVL.readData[0]),SIZEOF(GVL.readData)); END_IF post:=LEN(GVL.readDataBuf);
Last updated: 2024-01-14

Post by kevin123 on auto-answer dialog using system.prompt_answers CODESYS Forge talk (Post)
I am trying to do "update device" in a project which was saved in a different version of CODESYS using ScriptEngine, a dialog with 'Yes' and 'No' button popped up showing that "Do you want to upgrade the storage format for this project? -if you click 'Yes', storage format will be upgraded... -if you click 'No', storage format will not be changed..." I have to click the 'Yes' button automatically by scriptEngine. I know from others topics here in forum, that some dialogs can be auto-answered using system.prompt_answers. And I also get the messagekey of this dialog: Key: "<< No Key>>" Message: "Do you want to upgrade the storage format for this project? - If you click 'Yes',... i have tried using the system.prompt_answers command below, but the dialog was not auto-answered. system.prompt_answers["<<No Key>>"] = PromptResult.Yes Does someone know how to auto-answer the dialog using system.prompt_answers command with messagekey"<< No key>>"? or any suggestions to solve this issue, Thanks!
Last updated: 2024-01-26

Post by kevin123 on auto-answer dialog using system.prompt_answers CODESYS Forge talk (Post)
I am trying to do "update device" in a project which was saved in a different version of CODESYS using ScriptEngine, a dialog with 'Yes' and 'No' button popped up showing that "Do you want to upgrade the storage format for this project? -if you click 'Yes', storage format will be upgraded... -if you click 'No', storage format will not be changed..." I have to click the 'Yes' button automatically by scriptEngine. I know from others topics here in forum, that some dialogs can be auto-answered using system.prompt_answers. And I also get the messagekey of this dialog: Key: "<< No Key>>" Message: "Do you want to upgrade the storage format for this project? - If you click 'Yes',... i have tried using the system.prompt_answers command below, but the dialog was not auto-answered. system.prompt_answers["<<No Key>>"] = PromptResult.Yes Does someone know how to auto-answer the dialog using system.prompt_answers command with messagekey"<< No key>>"? or any suggestions to solve this issue, Thanks!
Last updated: 2024-01-26

Post by kevin123 on (no subject) CODESYS Forge talk (Post)
I am trying to do "update device" in a project which was saved in a different version of CODESYS using ScriptEngine, a dialog with 'Yes' and 'No' button popped up showing that "Do you want to upgrade the storage format for this project? -if you click 'Yes', storage format will be upgraded... -if you click 'No', storage format will not be changed..." I have to click the 'Yes' button automatically by scriptEngine. I know from others topics here in forum, that some dialogs can be auto-answered using system.prompt_answers. And I also get the messagekey of this dialog: Key: "<< No Key>>" Message: "Do you want to upgrade the storage format for this project? - If you click 'Yes',... i have tried using the system.prompt_answers command below, but the dialog was not auto-answered. system.prompt_answers["<<No Key>>"] = PromptResult.Yes Does someone know how to auto-answer the dialog using system.prompt_answers command with messagekey"<< No key>>"? or any suggestions to solve this issue, Thanks!
Last updated: 2024-01-26

Post by wbj0t on System libs and I/O Drivers CODESYS Forge talk (Post)
Hi everyone. My question about: where I can learn (read or watch) an info about codesys workflow through the system IO libs? I want to know how to implement I/O drivers by my self. In the system libs I see many interfaces, methods etc... But there is no explanation about them, just names of methods and fields of the FBs. I know about this page: https://forge.codesys.com/drv/io-drivers/doc/Generic/ There is so BIG the device description file and not so clear explaining of the attributes and elements, also some elements or attributes missed at it all. Yes, there are code examples on this page, but, so shortly and, for example, code about Modbus drivers is absent. And even if I try to add the IoDrvFB with lib, I get and error, something like: "failed to load IoDrvFB driver". And what about the book of codesys that written by Gary Pratt? Is there information about system libs and drivers in this book more clearly? Thank you :)
Last updated: 2024-02-02

Post by timl on BacNet "Unaufgelöste Referenz" CODESYS Forge talk (Post)
Hallo, ich habe Probleme beim nachbauen des BacNet2 Tutorials "Erste Schritte" aus der CODESYS Online Help. https://content.helpme-codesys.com/de/CODESYS%20BACnet/_bacnet_first_steps.html Das Anlegen des BacNet2 Servers und der danach folgenden BacNet Datenpunkte erfolgt ohne Probleme. Der Code lässt sich mit F11 auch Fehlerfrei generieren. Beim Download auf die SPS tritt dann der Fehler auf dem Bild auf. Anbei auch ein Bild des Logs nach dem Download. CODESYS BACnet 2.0.0.0 ist über den Installer runtergeladen. Device: CODESYS Control Win V3 x64 Version 3.5.19.40 CODESYS 3.5.19.40 Im Bibliotheksverwalter ist BACnet2 2.0.0.0 aufgeführt Die Konfigurationsdatei habe ich mit folgenden anpassungen abgespeichert: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows ;Component.8=CmpHilscherCIFX ;Component.9=CmpPCANBasicDrv ;Component.10=CmpCANFoxDrv ;Component.11=CmpIxxatCANDrv ;Component.12=CmpBlkDrvCanServer ;Component.13=CmpBACnet Component.14=CmpBACnet2 [CmpBACnet2] ;configuration file of the BACnet stack IniFile=$PlcLogic$/bacstac2.ini ;task priority of the BACstack process task, default: TASKPRIO_NORMAL_END (159) TaskPrio=128 ;name of the named pipe for the communication with the BACstack AppName=/tmp/BACnetServer Habe ich etwas vergessen?
Last updated: 2024-02-16

Post by wbj0t on mobus tcp slave device. read/write holdings with 2 variables. CODESYS Forge talk (Post)
Hi there. I have an issue to read and set time for the controller. In the issue many registers described as writable by 6/16 functions, and, in this time, also(!) readable! For example: I have time registers: min, hour, day, mon, year. By specifications it is possible check time (so I need always update these varibles in loop) and set time by writing these same registers, BUT how to set, if they will immediatle updated by current time after writing? So, I need to separate one address at two variables. I have seen option mark: Overlay of the process image by the holding and input register. I understand this so: When I READ by function 3, I will get variable that connected with the same INPUT address and when I WRITE by 6/16 this will change second variable that connected with HOLDING address. BUT, this mark doesnt work, when I write 6/16 and try to get by function 3, I will get written value instead INPUT variable. So, what to do?
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via CmpApp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by squiggleypuff on Can't Add New Version of Modbus TCP Master CODESYS Forge talk (Post)
I'm having a tough time trying to get Modbus working on a Festo CPX-E PLC; it throws these pre-compiler errors as soon as I add in my Modbus TCP Master 3.5.12.30 to my project: I'm confused about the C0046 error, as I have IODrvModbusTCP 4.3.0.0 Library installed. So I thought maybe I needed to use the newest Modbus TCP Master 4.3.0.0, which is in my device repository: However, whenever I go to add this underneath the Ethernet adapter (which is version 4.2.0.0), the only TCP Master version available is the old 3.5.12.30 one, even if I have Display all versions checked.: I even went so far as to delete the old version, but then there were no options to add a Modbus TCP Master under my Ethernet adapter. What needs to be done to use the newest Modbus TCP Master? Or are these pre-compiler errors unrelated and I'm missing something? Any help greatly appreciated.
Last updated: 2024-04-04

Post by tortilla on J1939 connection between two devices CODESYS Forge talk (Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23

Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh CODESYS Forge talk (Post)
Hi, I was hoping I could send the two files "application.app" and "application.crc" directly to the directory "/home/codesys/PlcLogic/Application" instead of logging into the device with codesys, downloading the program to the controller and then do the "create boot application", so it will reboot with the correct program running. I think i also need to edit the file "eRUNTIME.cfg" located in the "/home/codesys/ folder, because when I create the boot application from the codesys IDE, these lines are added to the file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app=0x212520, 0x2DBC747E, 2DBC747E.app I think the "eRUNTIME.cfg" file is the same as CODESYSControl.cfg I also dont know the purpose of the hexadecimal numbers etc. that is generated. When I tried to replicate what codesys was doing, I placed the same files in the same folder as when codesys generated the boot file. And also added the lines in the eRUNTIME.cfg file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app The controller did not boot up with any program, so my method did not work at all. I guess these lines tells the controller to run an application and where to find it? Could any of you help me with the best way to get the compiled program to the controller without using codesys or wago-software?
Last updated: 2024-05-28

Post by andrea199403 on Assigning Modbus addresses to a structure in a dynamic way CODESYS Forge talk (Post)
Hello everyone, I am new to this forum and I am also new to Codesys programming. My problem is this: I have a STRUCT of 64 bool and 30 real, this STRUCT is assigned in the programme 9 times. Now I need to communicate with an HMI via Modbus and I have defined the slave device and created the holding registers for communication. I would like to declare the first call of the STRUCT on the Modbus registers %QX2000.0 to %QX2007.7 for the booleans and on the registers %QW1004 to %QW1034 for the real registers. That said, I would like to change an index and set an offset of 100 bytes for the calls of the other 8 assignments, so that the result is: %QX2100.0 to %QX2107.7 for the booleans and on the %QW1104 to %QW1134 registers for the Real registers, etc. Is there a way to declare this? Thank you very much.
Last updated: 2025-10-21

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

Post by animesh on SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP CODESYS Forge talk (Post)
Hello everyone, I am facing a persistent issue with the OPC UA Server on Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) and need help from the community. Device Information Name: Advantech Control x86 RTE V3 x64 Vendor: Advantech Co., Ltd. Categories: PLCs Version: 3.5.20.10 Description: Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) Problem Summary The OPC UA Server works perfectly when accessed via: opc.tcp://localhost:4842 opc.tcp://<hostname>:4842</hostname> But it does NOT work when using the LAN IP: opc.tcp://192.168.0.XX:4842 In UAExpert I get: Discovery FindServers on opc.tcp://192.168.0.XX:4842 failed (BadCommunicationError) Port is LISTENING in windows Firewall.. Tried with turning off the firewall completely. System Information Windows 10 x64 Advantech CODESYS RTE Soft-PLC (hard real-time) Network IP: 192.168.0.XX Hostname: WINDOWS-XXXXX Need your Support
Last updated: 2025-11-24

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

Post by fredashbolt on Dynamically Update JSON Payload CODESYS Forge talk (Post)
I am trying to generate a JSON payload populated with a value that updates for use with a telemetry system, the payload is to be published by MQTT. I have established the MQTT client and can publish a working JSON payload but I can't get the payload to update as the value (iValue) changes. I am using a timer to trigger the .SetValue function periodically, but the JSON will only give the value as it is when it is first initialized using xFirst IF statement. Any suggestions? Thanks VAR pJsonData : POINTER TO JSON.JSONData := factory.Create(); fb_JBuilder : JSON.JSONBuilder; diRootIndex, diObject1Index : DINT; iValue : INT := 10 ; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; utf8JsonData : STRING(2000); diTempVal : DINT ; PublishTimer : TON ; END_VAR IF xFirst = TRUE THEN fb_JBuilder ( pJsonData := pJsonData , diRootObj => diRootIndex ) ; diObject1Index := fb_Jbuilder.SetKeyWithObject ( "Device" , diParentIndex := diRootIndex ) ; diTempVal := fb_Jbuilder.SetKeyWithValue ( "Temp" , iValue , diParentIndex := diObject1Index ) ; xFirst := FALSE ; END_IF PublishTimer ( IN := PublishTimer.Q = 0 , PT := T#5S ) ; IF PublishTimer.Q THEN fb_JBuilder.SetValue ( iValue , diTempVal ) ; END_IF jsonArrayWriter( xExecute := PublishTimer.Q , pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE ) ; JSON.Stu.ConvertUTF16toUTF8( ADR ( wsJsonData ) , ADR ( utf8JsonData ) , SIZEOF ( utf8JsonData ) , bStrictConversion := TRUE ) ;
Last updated: 2026-03-10

Post by chaylak on MC_ReadActualPosition with ST code CODESYS Forge talk (Post)
hi everyone, i am trying use MC_ReadActualPosition module in ST but i cant do it,( if i use CFC yes i read it) my axis is SoftMotion General Axis Pool->VirtAxisZ [Device: SoftMotion General Axis Pool] codesys V3.5 SP20 program: PROGRAM PLC_PRG VAR VirtAxisZ : AXIS_REF_VIRTUAL_SM3; fbPowerZ : MC_Power; fbReadPos : MC_ReadActualPosition; bEnable : BOOL := TRUE; lrActPos : LREAL; bValid : BOOL; bError : BOOL; fbResetZ : MC_Reset; xZ_Valid : BOOL; xZ_Busy : BOOL; xGlobalPower : BOOL; xGlobalReset : BOOL; xBtnTeachingMode : BOOL; lrGrvZ_OffsetTorque : LREAL := 0.5; lrPulseMmZ : LREAL; rPosFromBlock : LREAL; xZ_IsPowered : BOOL; xZ_PowerError : BOOL; iZ_PowerErrorID : LREAL; rZ_ActualPos : LREAL; lrTargetTorque : LREAL; sZ_ErrorString : STRING; //********** jog fbJogZ : MC_Jog; xJogForward : BOOL; xJogBackward : BOOL; rZ_ActVelocity : REAL; END_VAR fbResetZ( Axis:= VirtAxisZ, Execute:= xGlobalReset); fbPowerZ( Axis:= VirtAxisZ, Enable:= xGlobalPower, bRegulatorOn:= xGlobalPower, bDriveStart:=xGlobalPower , Status=> xZ_IsPowered, Busy=> xZ_Busy, Error=> xZ_PowerError, ErrorID=> iZ_PowerErrorID ); IF xGlobalPower THEN fbJogZ( Axis:= VirtAxisZ, JogForward:= xJogForward, JogBackward:= xJogBackward, Velocity:= 100, Acceleration:= 100, Deceleration:= 100, Jerk:= 1000); END_IF fbReadPos( Axis := VirtAxisZ, Enable := TRUE, Valid => bValid, Position => lrActPos, Error => bError ); IF VirtAxisZ.bError THEN sZ_ErrorString := 'Z Ex err'; ELSIF NOT xZ_IsPowered THEN sZ_ErrorString := 'Z Ex (Power Off)'; ELSE sZ_ErrorString := 'Z Ex Ready'; END_IF IF xBtnTeachingMode THEN lrTargetTorque := lrGrvZ_OffsetTorque; ELSE lrTargetTorque := 0; END_IF VAR_INPUT CFC_Motion: INT; END_VAR
Last updated: 2026-05-15

Post by megasilver on Cannot download program to CR1074 – Version mismatch error CODESYS Forge talk (Post)
Hello, I am having a problem downloading my application to an ifm CR1074 using CODESYS. When I try to download the program to the controller, I get the following errors: [FATAL ERROR] Version mismatch at: 'KEYBOARD_SET_MAPPING' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 [FATAL ERROR] Version mismatch at: 'SYSCFG_SPLASH_SET_SPLASH_SCREEN_VISIBLE' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 [FATAL ERROR] Version mismatch at: 'SYSTEM_IO_BACKLIGHT_SET_CURRENT_BACKLIGHT_BLOCKING' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 [FATAL ERROR] Version mismatch at: 'SYSTEM_IO_BACKLIGHT_SET_CURRENT_BACKLIGHT' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 [FATAL ERROR] Version mismatch at: 'KEYBOARD_RESET_LEDS_BLOCKING' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 [FATAL ERROR] Version mismatch at: 'KEYBOARD_SET_LED_COLOR' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 [FATAL ERROR] Version mismatch at: 'SYSCFG_DEVINFO_GET_KEYBOARDS_INFO' Requested version: 2.0.0.12 Implemented version: 3.4.0.0 The controller is running an OS version that should be compatible with CODESYS 3.5 SP16, and I am using the latest available ifm/ecomatDisplay package for this OS version. Therefore, I do not think this is simply a CODESYS or OS compatibility issue. It looks like the application expects system functions with version 2.0.0.12, while the controller implements version 3.4.0.0. Could this be caused by an incorrect or outdated library, device description, package installation, or a mismatch between the libraries used in the project and the libraries installed on the CR1074? What would be the correct way to identify which component is requesting version 2.0.0.12 and how can I resolve this version mismatch? Thank you for your help.
Last updated: 4 days ago

Post by nickpoon on SysProcessCreate stopped working after SP21? CODESYS Forge talk (Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02

Post by risele on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
You are welcome. Also note, that it's valid only if you modbus-device use same real/float value representation (IEEE 754). That's true for most of systems. But some devices may have other representation, such as integer + position of the decimal point, for example 123.456 is integer = 123456 and position = 3 Also note, that, ones again, depending on endianess of each system, you may also need to swap not just words, but bytes. TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; bVal:ARRAY[0..3] OF BYTE; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE than swapping may be something as VAR A,B,C,D:BYTE; //Bytes of the real value uIn, uOut:u_Real; rVal:REAL; ModbusReg1,ModbusReg2:WORD; END_VAR uIn.rVal:=rVal; uOut.A:=uIn.D; uOut.B:=uIn.C; uOut.C:=uIn.B; uOut.D:=uIn.A; ModbusReg1:=uOut.wVal[0]; ModbusReg1:=uOut.wVal[2]; Or you even need to reorder bits... Ones again, sending float/real values is not defined by Modbus protocol itself, so it is hardware- and software-dependent. The Modbus Poll (and most of modbus tools) have configuration parameters that will properly swap bytes on their side. Ones again, that's very helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/
Last updated: 2026-02-19

Post by alimans on Hex string CODESYS Forge talk (Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20

Post by andrej on Threads and TID created by CODESYSControl Win V3 CODESYS Forge talk (Post)
Hi all, for a deeper understanding of the Codesys RTE - I created a simple application with 3 IEC tasks (Ta,Tb,Tc) each with different priorities, and different cycle times. The application runs on Windows 10 in the Soft PLC CODESYS Control Win V3. If my understanding is correct, the RTE i.e. the Process CodesysControlService should spawn 3 threads (Th_a,Th_b,Th_c) which are executed with the defined cycle times, the priority of the threads should reflect the priority of the task set in the Codesys IDE. Does somebody have an idea, how I could identify the respective threads in Windows? Kind regards Andrej
Last updated: 2023-10-02