PLC Shell commands via ST Code
CODESYS Forge
talk
(Thread)
PLC Shell commands via ST Code
Last updated: 2025-03-04
Post by domebruce on Which database to use?
CODESYS Forge
talk
(Post)
We have developed a similar application few years ago with .Net and MS Sql Server. The database has about 30 tables, the more bigger tables have 2 or 3 thousands records. We can have multiple threads accessing at the same time to the DB. To garantie the data integrity we need to manage data locks and transactions. Thanks
Last updated: 2025-03-04
Which database to use?
CODESYS Forge
talk
(Thread)
Which database to use?
Last updated: 2025-03-04
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Im looking for a way to define predefined version of the same structures through "extends"/inheritance. What I want to do is best shown with an example: TYPE log_item_val_type : ( BOOL_ := 0, INT_, REAL_, STRING_ ); END_TYPE TYPE LOG_DATA_BASE STRUCT val_type : log_item_val_type; (* value, name etc *) ENDSTRUCT ENDTYPE (* this/below is not possible as I understand from the compiler?? *) TYPE LOG_DATA_BOOL extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.BOOL_; END_STRUCT END_TYPE TYPE LOG_DATA_INT extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.INT_; END_STRUCT END_TYPE etc. for LOG_DATA_REAL and ..STRING. The system will not allow me to "re-define" "val_type" however. Instead I must do the work-around of defining four different types with all fields individually defined. The benefit if I could extend the base item would be that Im (more) sure the structures are identical. In usage I can call in a specific type rather use the base type and assign which type. Usage by pointer/ref to log_data_base would also be easier.. (* Usage: *) log_data : log_data_int := (name, value etc.) (* Instead of: *) log_data : log_data_base := (name, value, val_type).. Is this possible to achieve in some way that I have missed?
Last updated: 2025-03-05
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Easier that I thought, by ALIAS TYPE log_item_val_type : ( BOOL_ := 0, INT_, REAL_, STRING_ ); END_TYPE TYPE LOG_DATA_BASE STRUCT val_type : log_item_val_type; (* value, name etc *) ENDSTRUCT ENDTYPE TYPE LOG_DATA_BOOL : LOG_DATA_BASE := (val_type := log_item_val_type.BOOL_); END_TYPE TYPE LOG_DATA_INT : LOG_DATA_BASE := (val_type := log_item_val_type.INT_); END_TYPE TYPE LOG_DATA_REAL : LOG_DATA_BASE := (val_type := log_item_val_type.REAL_); END_TYPE TYPE LOG_DATA_STRING : LOG_DATA_BASE := (val_type := log_item_val_type.STRING_); END_TYPE
Last updated: 2025-03-05
Post by pernockham on Engineering IDE from linux?
CODESYS Forge
talk
(Post)
Started playing with the idea of ditching windows for linux, one of the obstacles would be Codesys development. Alternatives: - linux with wine? - Run windows/codesys through virtual machine I guess a vm is the way to go? Anyone out there that could share their experience?
Last updated: 2025-03-05
Post by pernockham on Engineering IDE from linux?
CODESYS Forge
talk
(Post)
A good start seems to be this YT from Jakob Sagatowski: https://www.youtube.com/watch?v=Vqk5Td-uWqk
Last updated: 2025-03-05
Post by kuapiz on Camera RTSP Feed
CODESYS Forge
talk
(Post)
Hello, I'm facing the same problem, I can access the FLIR AX Series camera through the IP converter software (go2rtc). In the CODESYS 3.5.19 patch 7 software, the streaming does not appear in the webvisu even using the URL "http://xxx.xxx.x.xxx:1984/stream.html?src=flirr". I used the "RTC" and "MJPG" modes. HW: PFC200 750-8217/600-000. FW: v27. If anyone has a solution, could you help us?
Last updated: 2025-03-05
Camera RTSP Feed
CODESYS Forge
talk
(Thread)
Camera RTSP Feed
Last updated: 2025-03-05
Post by clarenced on Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the logic application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06
Post by clarenced on Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the HMI application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06
Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Thread)
Multiple applications on one device sharing variables.
Last updated: 2025-03-06
Post by alawwirbilal on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Hello, I have installed the runtime system on my raspberry pi 5 and when I scan for the devices it sees. But when I try to log in to the device it always ask me for a password and no matter what I give it says this is a wrong password. anyone could help?
Last updated: 2025-03-06
Post by alawwirbilal on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Note: this runtime system is used thanks in advanced!!
Last updated: 2025-03-06
Post by alawwirbilal on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Note: this runtime system is used
Last updated: 2025-03-06
Post by batuhanarslan on How to change font and font color rectangle/or related object
CODESYS Forge
talk
(Post)
Hi Everyone, I would like to ask something about how can i change text color an object if alarm state(true/false) released? or selected object number equal to selected object? Kind Regards,
Last updated: 2025-03-06
Post by imdatatas on Auto Declare window disappears by itself in the Ladder editor
CODESYS Forge
talk
(Post)
Hello Everyone, The "Auto Declare" window disappears by itself in the Ladder editor. For example, a new function block is wanted to be added to the Ladder editor. (For example; MC_Jog block and instance name will be fbMcJog). To do this, "Empty box with EN/ENO" is added to the ladder line from the Toolbox on the right and when you type MC_Jog in the empty box and press enter, normally the "Auto Declare" window appears and you are expected to be asked to write the instance name here. However, this "Auto Declare" window closes itself immediately, it does not wait for the user to enter a value or close the window. I often encounter this situation in many IDE versions. Does this seem like a bug? If anyone has encountered a similar problem while creating a new program name, function or function block instance name regarding the "Auto Declare" window and knows a solution, I would be glad if you could share it. Best wishes Imdat
Last updated: 2025-03-06
Post by fil on Using Latch Variable in Alarm as input from text list
CODESYS Forge
talk
(Post)
Good morning, I am currently working on a project where this would be of enormous value. Any input would be very welcome - thanks in advance. Best regards Fil
Last updated: 2025-03-06
Using Latch Variable in Alarm as input from text list
CODESYS Forge
talk
(Thread)
Using Latch Variable in Alarm as input from text list
Last updated: 2025-03-06
Post by reiterf on Visualisierungs-Stil White style, 3.5.16.0 verursacht Überseztungsfehler
CODESYS Forge
talk
(Post)
Hat sich erledigt, ich habe Codesys 3.5 SP20 Patch5 ganz neu installiert und die Projektdaten in ein neues Projekt kopiert :)
Last updated: 2025-03-06
Visualisierungs-Stil White style, 3.5.16.0 verursacht Überseztungsfehler
CODESYS Forge
talk
(Thread)
Visualisierungs-Stil White style, 3.5.16.0 verursacht Überseztungsfehler
Last updated: 2025-03-06
Post by tvm on VisuFbFrameBase.SetInputPositionData: The element id for the input position cannot be determined
CODESYS Forge
talk
(Post)
This came up again today, so I'll post the fix for future reference. Happens with Schneider Machine Expert 2.2 and M262 controllers. Add this bit of code to a program called from the visu task //disable "VisuFbFrameBase.SetInputPositionData" log messages, which fill up the logs IF VisuElems.Private_Visu_Globals.g_ValueChangedListenerManager.GetListenerCount() > 0 THEN VisuElems.Private_Visu_Globals.g_ValueChangedListenerManager.RemoveValueChangedListener(VisuElems.Private_Visu_Globals.g_ValueChangedListenerManager.listenerForOnValueChanged); END_IF
Last updated: 2025-03-06
VisuFbFrameBase.SetInputPositionData: The element id for the input position cannot be determined
CODESYS Forge
talk
(Thread)
VisuFbFrameBase.SetInputPositionData: The element id for the input position cannot be determined
Last updated: 2025-03-06
Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess)
CODESYS Forge
talk
(Post)
Wow! Thanks mr Strucc. Changed to service to run as local acc, and now log works! The service (run from local acc) is using this config: C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg The path you first mentioned (c:\Windows\System32\config\systemprofile\AppData\Roaming) has no CODESYS folder in it (Windows 11 24H2 b26100.3194). Thanks for your help :)
Last updated: 2025-03-06
Post by tvm on Passing properties as VAR_IN_OUT variables.
CODESYS Forge
talk
(Post)
Use a VAR_INPUT for properties. The reason for the error is that you can't get a reference to a property. Using a VAR_INPUT will copy the property to an input variable.