how to convert library from CodeSys 2.3 to CodeSys 3.x ?
CODESYS Forge
talk
(Thread)
how to convert library from CodeSys 2.3 to CodeSys 3.x ?
Last updated: 2020-01-21
Is it possible to simulate the codesys visualizations without project file/codesys?
CODESYS Forge
talk
(Thread)
Is it possible to simulate the codesys visualizations without project file/codesys?
Last updated: 2018-10-10
Identifier ioConfigConnector not defined. CODESYS IDE V3.5SP6 corruption after installation of CODESYS IDE V3.5SP10
CODESYS Forge
talk
(Thread)
Identifier ioConfigConnector not defined. CODESYS IDE V3.5SP6 corruption after installation of CODESYS IDE V3.5SP10
Last updated: 2017-10-20
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
CODESYS Forge
talk
(Thread)
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
Last updated: 2021-10-18
Codesys sales and support. Is it true that Codesys wants to get more customers?
CODESYS Forge
talk
(Thread)
Codesys sales and support. Is it true that Codesys wants to get more customers?
Last updated: 2023-07-03
Post by bmatlove on Re-create CoE online window in Visu
CODESYS Forge
talk
(Post)
Hello, I am trying to re-create the CoE online window within a Visu for purposes of checking and interacting with device parameters occasionally for maintenance purposes. To minimize reliance on using the IDE for misc interactions. Ideally, I would like to exactly mimic the CoE online window within the IDE. I assume that it uses a few tricks to minimize overhead, such as only polling registers which are within the visual scope, for example. I'm afraid it might be too much to ask for a pre-built drop-in Visu module to exist for this task. Do I have any options aside from manually re-creating all the logic to do this, relying heavily on SdoInfo function blocks? Is there a way for me to reference the device ESI file to shortcut the process of determining how many registers there are and getting the address for each?
Last updated: 2025-12-27
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by dkugler on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
I can confirm that at my 4ms EtherCAT Master the frames per second is equal at round about 500 with Codesys SP19. The same program at SP16 it was at 380-430 f/sec. for me it will be interesting too, whats the reason is for this high frame count/sec? I havn't had the time to use a paket sniffer and analyse all the frames. I can't help with your other questions, sorry.
Last updated: 2024-09-19
Post by wbj0t on tool 'update raspberry pi' unavailable
CODESYS Forge
talk
(Post)
Doesnt matter. I have installed sp20 with latest RP 4.13. Same problem. Anyway My large project in RP 4.10 and SP 19 and I need these versions and use same installation programm for Codesys IDE and RP4 package. I did install again, because my SSD broke and now cant update raspberry... I dont know how to translate correctly project to newest version - there are 52769 errors and incompatabilities: after updates libraries anyway some errors still because of devices... I found solution with .deb file from raspberry package - dont need IDE anymore for update raspberry.
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by garmusd on Raspberry Pi 5 GPIO not working.
CODESYS Forge
talk
(Post)
I paid money for the RPi runtime because the Product Description says that GPIO is supported. It is also written in the Versions that since 4.11 RPi5 is supported. And I use 4.13. Nowhere is it mentioned that GPIO is still not supported... It's a pity that the Codesys developers still can't find a way to fix it. Are there plans for when it will be fixed or are the developers too weak? Just wondering, is there anyone with a working GPIO? Can you share the details of your system?
Last updated: 2024-09-27
Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Hello, I have a problem when opening the license manager for my raspberry pi (CM4 model) with runtime 4.13.0.0. I select "Device" --> "Soft Container" and click on my device in the scan window but I get this error message : Licensing info not available. There is no dongle attached to this device. I can't install licenses anymore, and I don't understand why is CodeSys looking for a dongle when I specified I wanted to use a Soft Container. Can somebody help me please ? Best regards
Last updated: 2024-10-04
Post by mini-developer on Profinet Exor connection drop
CODESYS Forge
talk
(Post)
Hello, I have a Exor HMI with 2 seperatred ETH interface's. It is Configured as PN Master on ETH interface 1 and the IO's are working, as long as the development PC is connected to the ETH 0 interface. When the PC is disconnected, the PN communication drops and a reconnection is started. I installed the newest device description for Codesys and Firmware for the Panel. The IO Gateway is from Weidmueller What could cause the Problem?
Last updated: 2024-10-16
Post by winki on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
For small project, I would like to use my industrial computer as a PLC + Industrial Computer. Like that I can save the cost of one PLC. That why I am using Codesys on Linux. With the nic it is not working. I already set the IP adress with /etc/network/interfaces. Can it comes from there ? looking to "Control Linux SL" docuemntation it should work with rtu.
Last updated: 2024-10-23
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
I succeed to change the device to PI_SL but still the same problem of the I2C device switching between running and not running. the only difference with your project is that yo use I2C_master device version 4.7.0 and i 4.7.13, for GPIO i also use the 4.7.13 version and you the 4.7.0. Can you send me the older version of the Raspberry PI pheripals library, because i cannot choose lower version then 4.7.10 for the GPIO and I2C_master device
Last updated: 2024-11-11
Post by aliazzz on Raspberry Pi 3: Linux/ARMHFv7 unknown container technology
CODESYS Forge
talk
(Post)
Hi CODESYS team! It seems Podman for Raspberry Pi 3 is not detected correctly in the latest "Deploy Control SL 4.14.0.0" : Linux/ARMHFv7 unknown container technology. 1) The Communication Tab, device information section shows podman technology as DETECTED. 2) The Runtime Deployment menu message says: "unknown container architecture" 3) The pulldown window under the deployment tab doesn't show the options for ARMHF Virtual Edge SL and ARMHF Virtual Control SL. I hope you can fix this soon and keep up the great work!
Last updated: 2024-12-15
Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server
CODESYS Forge
talk
(Post)
Ok, for the sake of completeness in case anyone else has this problem. I can tell you that what finally worked for me was to change the line: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA", 5), structAData ); to: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA|defaultbinary", 5), structAData ); I'm sure there are many other problems that could cause this very generic error, but this was my problem.
Last updated: 2024-12-30
Post by krisj on ScriptEngine POU property Get and Set accessor.
CODESYS Forge
talk
(Post)
Hey! I am trying to generate a function block with properties from a list with script engine. Codesys/ScriptEngine creates both the Get and the Set accessor. I cannot find a way to delete the Set method/accessor. Anyone encountered the same problem or have a solution for this? for prop_name, prop_type in list: property = pou.create_property(prop_name, prop_type) get = pou.find("Get", recursive=True)[i] get.textual_declaration.replace("") get.textual_implementation.replace(prop_name + " := " + struct_name + "." + prop_name + ";") set = pou.find("Set", recursive=True)[i] set.textual_declaration.replace("") set.textual_implementation.replace("") i += 1
Last updated: 2025-03-17
Post by kuegerls on OpC UA server on Raspberry Pi MC SL - Certificate Issue
CODESYS Forge
talk
(Post)
Hello, I have set up an OPC UA server following several guides, including this one: https://revolutionpi.com/documentation/tutorials/opc-ua-codesys-nodered/. The license for the runtime is installed on the device. However, I am unable to create a certificate for the OPC UA server in the security screen. I always get the error message: "The certificate has not been created by the device." Does anyone have an idea what might be causing this issue? Any help would be greatly appreciated! Thanks in advance! Best regards, Stefan
Last updated: 2025-04-02
Post by eschwellinger on CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC
CODESYS Forge
talk
(Post)
I would recommend to ask Moxa for a newer version of Debian. Debian 9 ("Stretch") has reached its end of life and is no longer receiving security updates from the official Debian Security Team as of June 30, 2022. This means any systems still running Debian 9 are vulnerable to security risks and should be upgraded to a newer, supported version of Debian like Debian 10 ("Buster") or Debian 11 ("Bullseye").
Last updated: 2025-07-14
Post by gseidel on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR]
CODESYS Forge
talk
(Post)
Hi imdatatas, sorry to hear this issue caused so much overhead for you. Frankly, I'd expect a project created with an older version to compile without errors after opening > it with the latest Codesys version and updating all libraries. Yes, that is a reasonable expectation. I tried a few times but could not reproduce the problem. In case you run into the problem again, we can investigate the issue if you send a project archive. Best regards, Georg
Last updated: 2025-10-02
To search for an exact phrase, put it in quotes. Example: "getting started docs"