Search talk: how to download library

 
<< < 1 .. 173 174 175 176 177 .. 264 > >> (Page 175 of 264)

Post by brouwyka on JSONByteArrayWriter string result incorrect order CODESYS Forge talk (Post)
Hello everybody! We are currently working on implementing a call to an API that tracks data sent to it through a JSON body. Versions: CODESYS V3.5 SP19 Patch 7 using IIOT Libraries SL license, specifically JSON Utilities SL version 1.13.0.0. For simplicity, let's say we want to construct the following JSON body for our request (simplified to just 1 key-value pair in each of the array objects to keep things shorter, but we'd have multiple fields in each in reality): { "id": "machine_1", "readings": [ { "temp_mid": 153.8 }, { "temp_mid": 98.3 } ], "status": "RUNNING" } However, our "readings" data is added over time, not in creation, so calls to the builder would be somewhat out of order. In a simplified manner, our calls would look like this: jsonBuilder(pJsonData := JsonData, diRootObj => rootJsonIndex); // rootJsonIndex = 0. // Set "id" at root JSON object. wsValue := "machine_1"; jsonBuilder.SetKeyWithValue("id", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 1, VALUE: diParentIndex = 1 & diIndex = 2. // ... Time passes, we get our first reading to add ... // The "readings" array does not exist yet, so we make it first at root JSON object before adding our first reading. readingsJsonArrayIndex := jsonBuilder.SetKeyWithArray("readings", diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 3, VALUE: diParentIndex = 3 & diIndex = 4. // Then add the first reading, for which we first have to make an object. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 5. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the first object in the array. rValue := 153.8; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := readingsJsonArrayObjectIndex); // JSONData KEY: diParentIndex = 5 & diIndex = 6, VALUE: diParentIndex = 6 & diIndex = 7. // ... Time passes, we want to add another root-JSON-level field ... // Set "status" at root JSON object. wsValue := "RUNNING"; jsonBuilder.SetKeyWithValue("status", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 8, VALUE: diParentIndex = 8 & diIndex = 9. // ... Time passes, we want to add a second reading ... // "readings" array exists, so add the second reading, but first we have to make another object. // NOTE the re-use of the earlier stored `readingsJsonArrayIndex`, so we add the new object to that previously created array. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 10. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the SECOND(, new) object in the array. rValue := 98.3; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 10 & diIndex = 11, VALUE: diParentIndex = 11 & diIndex = 12. // ... Finally, we want to send to the API, so we must convert the builder to data the client accepts as a body ... xTestWriteToJsonArray := TRUE; jsonArrayWriter( xExecute := xTestWriteToJsonArray, pwData := ADR(jsonDataString), udiSize := SIZEOF(jsonDataString), jsonData := JsonData^ ); IF jsonArrayWriter.xDone THEN // The writer was successful, the `jsonDataString` VAR should now contain a WString copy of the JSON object from the builder. xTestWriteToJsonArray := FALSE; END_IF We see that the JsonData STRUCT is correctly organised (in terms of the diParentIndex & diIndex set by it for each JsonElement) as we expect, as outlined in my comments in the simplified code above. However, as soon as we pass it to the jsonArrayWriter (which is a JSON.JSONByteArrayWriter), the resulting jsonDataString does not match our expectations, instead coming out like this: { "id": "machine_1", "readings": [ { "temp_mid": 153.8 } ] } { "temp_mid": 98.3 } "status": "RUNNING" The behaviour of the JSONByteArrayWriter thus seems to be the problem here. It does not seem to correctly process the children of JsonElements that are ARRAYs when additions to them are done broken up by additions to the lower level JSON OBJECT they are a part of. We have confirmed this by changing the order of the calls in our example to add both readings before adding the "status", in which case we get our expected outcome. However, in reality this is not possible for us - additions to any of the JSON's objects, arrays or array objects may happen at any time after other fields elsewhere in the JSON have been added. Does anyone know a way around this, a fix, or knows a solution we simply have not found? This same phenomenon was also noted on this forum by user @ryusoup at the end of 2023 (https://forge.codesys.com/forge/talk/Engineering/thread/c45929e2f1/#e27f) and user @mtho in early 2024 (https://forge.codesys.com/forge/talk/Engineering/thread/cd1bb450db/#1292) but both topics received no activity beyond both users' opening posts. Looking through the release notes of all the versions of the JSON Utilities SL library, I also did not see any remarks on resolutions of bugs in this vain. Thanks in advance for the assistance!
Last updated: 2026-06-10

Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64 CODESYS Forge talk (Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25

Post by brouwyka on JSONByteArrayWriter string result incorrect order CODESYS Forge talk (Post)
Additional note: When doing all additions to a JSON array one after another without additions outside the array inbetween (and no more additions to the array after an item outside the array has been added) - which is not a viable solution for us as we might add items to any of the arrays at any time, but we tested regardless to be thorough - we get the following result: { "id": "machine_1", "readings": [ { "temp_mid": 153.8 }, { "temp_mid": 98.3 } ], "status": "RUNNING" } This mostly matches our expected outcome, aside from the JSONByteArrayWriter not adding indenting before closing square brackets ("]") at all. That doesn't matter for JSON of course, as it's not sensitive to indenting, but it's still a bug regardless. Also, it adds an unnecessary newline between items in the array (at least when having an array of objects, we haven't tested with arrays of primitives). I also want to reiterate that this is not a viable workaround for the issue for us - we have to be able to add to any array at any time, which should be possible according to the docs, and we are 100% sure indexes are correctly being managed and built up by the JSONBuilder and our wrapper (to track the index of each array & the latest item added to each exactly to make use of the documented possibility to add anything anywhere in the JSON at any time as long as you keep track of the returned indexes) around it.
Last updated: 2026-06-10

Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection CODESYS Forge talk (Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18

Post by bschraud on Code erzeugen mit kryptischer Fehlermeldung mit GVL_Io_dd05d808 CODESYS Forge talk (Post)
Hallo, beim Codeerzeugen bekomme ich wiederholt Fehlermeldungen, bei denen nicht mit einem Klick in das betroffene Modul gewechselt werden kann. Die Fehlermeldung tritt allerdings nach "Gerät aktualisieren" nicht mehr auf. Wenn ich das Projekt speichere, Codesys schließe, anschließend Codesys wieder starte und Code erzeugen will, tritt der Fehler wieder auf: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] PAC: C0032: Typ 'Unbekannter Typ: 'ADR(GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7)'' kann nicht in Typ 'POINTER TO IoConfigParameter' konvertiert werden [FEHLER] PAC: C0077: Unbekannter Typ: 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' [FEHLER] PAC: C0046: Bezeichner 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' nicht definiert Kompilierung abgeschlossen -- 3 Fehler, 1 Warnungen Übersetzung abgeschlossen -- 3 Fehler, 1 Warnungen : Kein Download möglich Die Recherche nach der Bedeutung von "HPS_7" oder "GVL_Io_dd05d808" verlief leider ergebnislos. Ich habe nur einen ähnlich erscheinenden Thread gefunden, der aber nicht gelöst wurde: https://forge.codesys.com/forge/talk/Engineering/thread/0666dce94f/ Ich verwende Codesys 3.5 SP20 (64bit) mit CODESYS Control for Raspberry Pi MC SL 4.11.0.0. Alle anderen Geräte sowie die Projektumgebung sind frisch aktualisiert. Kennt jemand die Bedeutung dieser Fehler bzw. wie man sie beheben kann? Vielen Dank für die Hilfe
Last updated: 2024-05-16

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17

Post by bschraud on Speicherbegrenzung für lokale Variablen CODESYS Forge talk (Post)
Aufgrund einer Schnittstellenänderung muss ich meine Messagebuffer erheblich vergrößern. U.g. Konstante bestimmt die Größe einer Byte-Array-Definition, die in einer Struktur für 9 Botschaften verwendet wird. Ich benötige also 177372byte zusätzlichen Speicher in dem Modul in dem die Struktur als lokale Variable angelegt wird. Dynamisches Allokieren zur Laufzeit möchte ich vermeiden, damit ich nicht während des Betriebes Fehler aus dem Allokieren behandeln muss. Für ein Reservieren des Speicherbereiches habe ich in Codesys keine Einstellmöglichkeiten gefunden. Die Applikation läßt sich ohne weitere Modifikation kopilieren, scheitert aber bei der Ausführung. Welche Lösungs- oder Einstellmöglichkeiten gibt es? Bei c_w_process_result_content_len_max: WORD := 292; [INFORMATION] Größe des lizenzierten Benutzercodes: 363304 Bytes [INFORMATION] Speicherverbrauch auf dem Gerät, nicht für Lizenzierung verwendet: [INFORMATION] Speicherbereich 0 enthält Daten, Eingang, Ausgang, Speicher und Nicht-sichere Daten: Größe: 2807632 Bytes , höchste verwendete Adresse: 2159712, größte zusammenhängende Speicherlücke: 647920 Bytes (23 %) [INFORMATION] Speicherbereich 3 enthält Code: Größe: 7267784 Bytes , höchste verwendete Adresse: 5590600, größte zusammenhängende Speicherlücke: 1677184 Bytes (23 %) Übersetzung abgeschlossen -- 0 Fehler, 10 Warnungen : Bereit für Download Speicherprüfung: [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag GVL.htFactory._itfInstList.__Interface in Area 0, Offset 0x000033BC (0x71C15414) [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag __datasourcesInstancesGVL.__datasourcesInstances.dsInst._allItemsHashtable._ht.__Interface in Area 0, Offset 0x00128904 (0x71D3A95C) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_L_Instance._IIoDrv.__Interface in Area 0, Offset 0x0018EC00 (0x71DA0C58) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_S_DAC_Instance._IIoDrv.__Interface in Area 0, Offset 0x0018F090 (0x71DA10E8) [INFORMATION] PAC: Überprüfter Speicher für 21336 Objekte. 4 Prüfung(en) fehlgeschlagen. [INFORMATION] PAC: Check took 00:00:13.9743220. Applikation lässt sich downloaden und funktioniert auf dem Gerät. Nach der Vergrößerung: c_w_process_result_content_len_max: WORD := 20000; [INFORMATION] Größe des lizenzierten Benutzercodes: 363304 Bytes [INFORMATION] Speicherverbrauch auf dem Gerät, nicht für Lizenzierung verwendet: [INFORMATION] Speicherbereich 0 enthält Daten, Eingang, Ausgang, Speicher und Nicht-sichere Daten: Größe: 4114264 Bytes , höchste verwendete Adresse: 3164816, größte zusammenhängende Speicherlücke: 949448 Bytes (23 %) [INFORMATION] Speicherbereich 3 enthält Code: Größe: 7267832 Bytes , höchste verwendete Adresse: 5590640, größte zusammenhängende Speicherlücke: 1677192 Bytes (23 %) Übersetzung abgeschlossen -- 0 Fehler, 10 Warnungen : Bereit für Download Speicherprüfung: (gleiches Ergebnis wie vorher) [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag GVL.htFactory._itfInstList.__Interface in Area 0, Offset 0x000033BC (0x71C15414) [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag __datasourcesInstancesGVL.__datasourcesInstances.dsInst._allItemsHashtable._ht.__Interface in Area 0, Offset 0x0021DF38 (0x71E2FF90) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_L_Instance._IIoDrv.__Interface in Area 0, Offset 0x00284238 (0x71E96290) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_S_DAC_Instance._IIoDrv.__Interface in Area 0, Offset 0x002846C8 (0x71E96720) [INFORMATION] PAC: Überprüfter Speicher für 21336 Objekte. 4 Prüfung(en) fehlgeschlagen. [INFORMATION] PAC: Check took 00:00:14.0491831. Applikation lässt sich downloaden. Ausführen mündet in Ausnahmefehler Die Applikation läuft auf der Runtime CODESYS Control for Raspberry Pi MC SL. Die Codesys Version ist 3.5 SP20 mit allen Updates. Kennt jemand eine Speichergrenze für lokale Variablen bzw. eventuelle Einstellmöglichkeiten? Vielen Dank
Last updated: 2024-05-06

Post by mubeta on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
How are the servo drives controlled? EtherCAT, step/dir pulses, other? CANOpen, 1 Mb/s, bus load 35%, cycle time 2ms. Another thought is that - if it's step/dir pulse based control - the pulses from the PLC to the drive are getting missed/lost at high frequencies? If that's the case then there would be multiple troubleshooting steps/corrections that could be investigated. Here, it seems to me that we are getting completely off track with the observed problem. You could try to create a simplified program I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. However, in emulation I was interested in checking other aspects of the process, not this specific one which is for real a correction made necessary after the fact. The part of the program that does this correction with the function mentioned in the topic, came up from its origins, but I didn't know or didn't think it was really useful. A scruple that later turned out to be necessary. However, for now I do not think I will spend any more time on this verification, already lacking any to do my normal. I remain amazed, however, that a function intended to correct the axis position with the motor in motion and that it should not interfere with this, in fact instead changes behavior as the motor speed changes. Mah! When you manually control the motor directly from the servo drive software at the speeds you are calling for, does it move precisely to the target position? The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem. What I need to resolve is the fact that a clutch specially placed at a certain point can slip and, therefore, I have the undeniable need to phase the 'prime mover' to the mechanical position of the machine, detected by a cam for each turn, in order to properly stop at its optimum point. Which for now I have ruled out doing. In fact, if I really have to say, since we have now gone brutally OT, I originally thought that this clutch should only come into action in cases of extreme necessity, as happens in most trials. But this one, the way it is made, slips more easily than I could estimate and the servo-controlled 'prime mover,' and the machine, get out of phase, maybe by a little, but frequently, and when the machine work at it's high speed, (in fact all of the time), I can't adjust properly the 'prime mover' position at fly.
Last updated: 2025-01-18

Post by timl on BacNet "Unaufgelöste Referenz" CODESYS Forge talk (Post)
Hallo, ich habe Probleme beim nachbauen des BacNet2 Tutorials "Erste Schritte" aus der CODESYS Online Help. https://content.helpme-codesys.com/de/CODESYS%20BACnet/_bacnet_first_steps.html Das Anlegen des BacNet2 Servers und der danach folgenden BacNet Datenpunkte erfolgt ohne Probleme. Der Code lässt sich mit F11 auch Fehlerfrei generieren. Beim Download auf die SPS tritt dann der Fehler auf dem Bild auf. Anbei auch ein Bild des Logs nach dem Download. CODESYS BACnet 2.0.0.0 ist über den Installer runtergeladen. Device: CODESYS Control Win V3 x64 Version 3.5.19.40 CODESYS 3.5.19.40 Im Bibliotheksverwalter ist BACnet2 2.0.0.0 aufgeführt Die Konfigurationsdatei habe ich mit folgenden anpassungen abgespeichert: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows ;Component.8=CmpHilscherCIFX ;Component.9=CmpPCANBasicDrv ;Component.10=CmpCANFoxDrv ;Component.11=CmpIxxatCANDrv ;Component.12=CmpBlkDrvCanServer ;Component.13=CmpBACnet Component.14=CmpBACnet2 [CmpBACnet2] ;configuration file of the BACnet stack IniFile=$PlcLogic$/bacstac2.ini ;task priority of the BACstack process task, default: TASKPRIO_NORMAL_END (159) TaskPrio=128 ;name of the named pipe for the communication with the BACstack AppName=/tmp/BACnetServer Habe ich etwas vergessen?
Last updated: 2024-02-16

Post by ofey on Codesys Soft PLC OPC UA server CODESYS Forge talk (Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14

Post by riccardo on VisuElems.CurrentUserGroupId is not stable CODESYS Forge talk (Post)
Goodmorning TimvH, Thanks for the reply. I don't know if your solution solve my trouble yet, I am going to see the link you sent me. In the mean time I try to explane better what I need to do. I have a turbine system that get in alarm under some condition (E.g low speed of turbine) and block the itself. When the system is stoped there is no speed turbine and the system cannot start. To give to the operetor the possibility to bypass the alarms, there is an acknoledgement alarm pushbutton. This bypass must not work for everyone but only for those client that perform the login by (User Management). Furthermore, if the user perform the (manual or automatic) logout in alarm conditions, the acknowlegment must be annulled and block the system again. To do this, I need to know if an operator is logged in the page and is working to fix the problem; otherwise the syste must autoturn off again. Now I go to study your solution, if I have explaned better and you have another idea tell me please.
Last updated: 2023-11-16

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by struccc on The future and proper use of CAA.BOLT, CAA.SEMA,.. CODESYS Forge talk (Post)
Dear All, Dear CODESYS, I'm curiously following CODESYS transitioning away from the CAA libraries, and I'm mostly in favor of these major changes. Naturally, I'd like to align my current (not end-user) developments accordingly. I'm tracking , reading release notes, ... And want to figure out the future :) Is it possible to hear / read more about the reasons, objectives and scope of these changes? One important element is CAA Types - CAA Types Extern. What is the plan with that? What's the future of CAA.SEMA, CAA.BOLT ? I have never used them (always relied on SysLib*), but they are tempting... Would be useful to have a platform independent "Macro" for this functionality... Is there something in existing or planned ? Are they suitable to be used in low level libraries... For Example IO-Drivers, Components, "to-become system libraries"? CAA.TaskLock, CAA.TaskUnlock ? Well, they don't claim platform independency, so I can't rely on those.... Any up-to-date advise, standard, pattern to follow in new libraries for task and resource locking? Practical set of conditional defines to be used? If this information is not publicly available, can you please send a private message about the proper way to achieve this? I have support agreement, just couldn't get trough with these questions... P.
Last updated: 2025-03-14

Post by duvanmoreno24 on Modbus writing on value change CODESYS Forge talk (Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03

Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh CODESYS Forge talk (Post)
Hi, I was hoping I could send the two files "application.app" and "application.crc" directly to the directory "/home/codesys/PlcLogic/Application" instead of logging into the device with codesys, downloading the program to the controller and then do the "create boot application", so it will reboot with the correct program running. I think i also need to edit the file "eRUNTIME.cfg" located in the "/home/codesys/ folder, because when I create the boot application from the codesys IDE, these lines are added to the file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app=0x212520, 0x2DBC747E, 2DBC747E.app I think the "eRUNTIME.cfg" file is the same as CODESYSControl.cfg I also dont know the purpose of the hexadecimal numbers etc. that is generated. When I tried to replicate what codesys was doing, I placed the same files in the same folder as when codesys generated the boot file. And also added the lines in the eRUNTIME.cfg file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app The controller did not boot up with any program, so my method did not work at all. I guess these lines tells the controller to run an application and where to find it? Could any of you help me with the best way to get the compiled program to the controller without using codesys or wago-software?
Last updated: 2024-05-28

<< < 1 .. 173 174 175 176 177 .. 264 > >> (Page 175 of 264)

Showing results of 6586

Sort by relevance or date