Post by ac-spr on Runtime variable that indicates a user is online to the code
CODESYS Forge
talk
(Post)
Looking to access a variable at runtime that indicates a user is online to the code. essentially want to use this value to feedback to the user on the HMI. we use turck and bosch rexroth devices if this information helps. I was hoping there was a variable at the application level, or a library that could be used but I was unable to find anything. I know there's a pop up when you try to login/ go online to the code when a user is already logged in, so the system does provide an indication that it knows already online, but has no access to a value from what I can see. Any help is appreciated
Last updated: 2024-04-22
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
Epis doesnt want Softmotion. I thought it was about the price. If it was possible it would be working already and i dont need an extra licence. Thats the problem of codesys. The software is running but hangs on its license. Epis made it posible to see the stick. I can see the license. Softmotion is there from 3.5.14.Xx Like is said And Motion control is alrady posible 15 year ago. And i only need a Sync of 2 drives. I want a good solution not a refund. Dont point to the manufacturer. The software is made by 3s not by epis .
Last updated: 2024-04-29
Post by k2saki on CNC / G-Code streaming processing ( to start quickly in long G-Code File )
CODESYS Forge
talk
(Post)
Is it possible like G-Code streaming processing (like FANUC or SIEMENS DNC Function )? Or Does anyone know the tips for CODESYS Motion to start moving long Long G-Code File quickly? I have to wait long time after "Start" button to start moving, I have to wait finishing interpreting whole G-Code file, ( and I have to prepare huge buffer to store. ) Now, I'm working on my CNC Project using SMC_ReadNCFile2, and SMC_NcInterpreter to preprocess G-Code. I tried to set SMC_Interpolator.xExecute to true to Start while after SMC_NcInterpreter processed more 50-line of G-Code, but that not worked, I had to wait SMC_NcInterpreter processed all lines to start SMC_Interpolator. G-Code have about 2000 lines of XY of G01 (or more over.. ) of short segment that a CAM software has exploded from NURBS Curve.
Last updated: 2024-05-03
Post by k2saki on CNC Open Source Project / Can I convert my project to text-files ?
CODESYS Forge
talk
(Post)
Hi. I published My CODESYS-CNC Project to GitHub and I set it Open Source Software. Here https://github.com/k-s-saki/RPi_CODESYS_CNC My CNC Project is binary file , using FBD for IPO , so I found it is a little bit hard to work with people on GitHub. (diff / merge ) My question is 1) Is it possible to convert my project ( only POUs is also fine ) into text file ? How? 2) Would it be better to rewrite all FBD/LD into ST and copy them manually to text files? Thanks.
Last updated: 2024-05-16
Post by stewnguth on New License not working.
CODESYS Forge
talk
(Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23
Post by jaspergain on Non-existing identifiers
CODESYS Forge
talk
(Post)
Hello, I got a bit of a weird issue going on which is kind of annoying. So recently we switched a lot of Modbus IO to EtherCAT, as we were having issues with stability. All works fine, which is great. But sometimes when I change the program I get errors claiming that identifiers are not defined. Meaning I can't go online. See the picture below. I believe this is because some of these identifiers were used with Modbus, and they weren't properly removed/deleted? A clean all temporary fixes the issue, but it comes back again after a while of changing the code, and building. Any way to fix these non-existing required identifiers, or even find out where they are required? Thanks for the help in advance. Jasper.
Last updated: 2024-05-29
Post by zer0g on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
I'm using the code bellow which is based on the Codesys example: FUNCTION_BLOCK MODBUS_master_example_ST VAR initDone : BOOL := FALSE; aIPAddress : ARRAY [0..3] OF BYTE := [127,0,0,1]; clientTcp: ModbusFB.ClientTcp; // buffer to read input registers aDataInputRegisters : ARRAY[0..9] OF UINT; // some client requests clientRequestReadInputRegisters: ModbusFB.ClientRequestReadInputRegisters; xExecute: BOOL; END_VAR IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=aIPAddress, uiPort:=502, udiLogOptions := ModbusFB.LoggingOptions.All); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=1, udiTimeout:=TO_UDINT(T#1000MS)); END_IF // call the client FB's clientTcp(); clientRequestReadInputRegisters(rClient:=clientTcp,xExecute := xExecute AND NOT clientRequestReadInputRegisters.xBusy ,uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0])); As you can see the clientTCP is called cyclically with the same result.
Last updated: 2024-05-30
Post by starmaxou on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
CODESYS Forge
talk
(Post)
Hi everyone, I'm trying to install the CODESYS Control for Raspberry Pi SL package. The computer with CODESYS software is offline for security reasons. So, I downloaded the package on another computer and installed it manually. But this package has dependencies packages: CODESYS.Control SL Extension Package, V4.0.0.0 CODESYS.Control SL Deploy Tool, V4.10.0.0 As I said, the computer with CODESYS is offline. I cannot use the package installer to search for these packages. I did not find them in Codesys Store with another computer. Do you know where to find and download them? Thank you in advance for your help!
Last updated: 2024-05-30
Post by ragarcia on How to change login visualization for other visualization after user logged in
CODESYS Forge
talk
(Post)
Hello everyone, I have a web visualization on Codesys and to be able to use the web visualization first an user and a password is requested. After the user logged in, I want to automatically change the visualization to the 'Home' visualization but I am not sure how to do this. In the login visualization I basically have a button with the input configuration to execute the action 'Login' after a click. Once the user is logged in, the visualization is still stuck in the login page and I want to automatically change to Home visualization if the user was succesfully logged in. How can I know the number of web visualization clients connected to my PLC? Thanks in advance
Last updated: 2024-06-04
Post by gatto on Modbus tcp - channel
CODESYS Forge
talk
(Post)
Hi can you give more details? Are you talking about a danfoss? wich model? Can post the configuration of channel' I used, on the past, serial modbus with danfoss fc280 I remember ((id x 10)-1) I remember that you couldn't use continuous reading/writing of the directors but you had to use them one at a time. it seemed that reading empty registers (caused by x10) was not accepted by danfoss. So I had created a scan that used just one register, then the next etc etc with a timed interval. But this was for the serial, I don't know if it's the same thing with ethernet. I currently use Ethernet TCP/IP interface with FC280.
Last updated: 2024-06-13
Post by kazuhiro on Problems using MySql Library and SysProcessExecuteCommand2 together
CODESYS Forge
talk
(Post)
I use fbMsSQL_compact(FUN) of the MySQL Library to write data to the database. There is no problem when writing data using only fbMsSQL_compact(FUN). However, when I try to write data obtained using SysProcessExecuteCommand2 to the database using fbMsSQL_compact(FUN), an error message "Dest server on ip address:xxx.xxx.xxx.xxx and port:1433 is unreachable" appears and writing is not possible. From what I have researched, it seems that writing is not completed in one cycle of fbMsSQL_compact(FUN), and when SysProcessExecuteCommand2 is executed first in the second cycle, the work done in one cycle of fbMsSQL_compact(FUN) is reset. Could you please give me some advice?
Last updated: 2024-06-18
Post by kazuhiro on Problems using MySql Library and SysProcessExecuteCommand2 together
CODESYS Forge
talk
(Post)
I use fbMsSQL_compact(FUN) of the MySQL Library to write data to the database. There is no problem when writing data using only fbMsSQL_compact(FUN). However, when I try to write data obtained using SysProcessExecuteCommand2 to the database using fbMsSQL_compact(FUN), an error message "Dest server on ip address:xxx.xxx.xxx.xxx and port:1433 is unreachable" appears and writing is not possible. From what I have researched, it seems that writing is not completed in one cycle of fbMsSQL_compact(FUN), and when SysProcessExecuteCommand2 is executed first in the second cycle, the work done in one cycle of fbMsSQL_compact(FUN) is reset. Could you please give me some advice?
Last updated: 2024-06-18
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
Hello, CODESYS Control is running on my RevPi, and my system communicates over a CANbus with a master using the ConnectCan module (Slave - CANopen Device). The communication works perfectly fine so far. However, as soon as I call a Python script with "SysProcessExecuteCommand2" that creates a CSV file and executes without errors, the master does not adopt any changes to the Transmission Process Data Objects (TPDOs). I don't quite understand what one has to do with the other, and perhaps someone can help me with this. Here is my script call: SysProcess.SysProcessExecuteCommand2(pszCommand:='python /home/pi/test.py', pszStdOut:=sCMDOutput, udiStdOutLen:= SIZEOF(sCMDOutput), pResult := ADR(eResult)); Thank you in advance! Best regards, Stefan
Last updated: 2024-06-20
Post by rohan on Child Application Alarm
CODESYS Forge
talk
(Post)
Hi All, I'm trying to develop a multi-application project that allows me to switch between applications. I currently have a parent application and several child applications, as this is the only way for them to share CAN/Ethernet communication. I've noticed that I am only able to create an Alarm Configuration for the parent application. But the children application do not seem to be displaying alarms on the Alarm Table in the visualisation for when an alarm is raised. Does anyone know of a fix, solution or a way around this? I am utilising Codesys v3.5 SP16 Patch 5 64Bit
Last updated: 2024-06-21
Post by alimans on Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Post)
For anyone still experiencing this issue, hereβs how I managed to solve it: Symptoms: 1. Sometimes, on the first start of CODESYS Runtime, the modules fail to run. 2. After disconnecting and reconnecting the communication cable, the drive does not start again. 3. MC_Reset cannot clear the fault. Solution (what worked for me): 1. Check the axis communication using the SMC_CheckAxisCommunication function block (FB). 2. If CheckAxisCommunication.eComState of the axis is equal to or higher than SMC_CommunicationState.SMC_COMSTATE_BASE_COM_INITIALIZATION, then 3. Use the SMC3_ReinitDrive function block to reset the drive β and it works. For more information, refer to the official CODESYS documentation: π https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/DriveInterface/AXIS_REF/SMC3_ReinitDrive.html
Last updated: 2025-10-23
Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27
Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27
Post by msegon on OPC UA Client failed to connect
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I'm trying to read data from Tridium Niagara 4.15 OPC UA Server, but I get the error BadCertificateInvalid. As far as I understand, you need to add a CA certificate somewhere to establish a secure connection, but I don't know where. 2025-10-27T09:06:43.247Z, 0x0000008d, 4, 0, 0, * ERROR: OpcUa_Channel_BeginConnect: Cannot create secure channel without certificates! 2025-10-27T09:06:43.247Z, 0x00001090, 4, 0, 0, * ERROR: Datasource: Error Failed (268468242) in state Connecting I tried communicating without encryption, but it doesn't find the point. Has anyone managed to establish encrypted OPC UA communication?
Last updated: 2025-10-28
Post by davidbo on How to stop dhcpcd and use SysSockSetIpAddressAndNetMask to set address?
CODESYS Forge
talk
(Post)
It is stated: "Dynamic ip address, provided by DHCP, BOOTP, etc. Cannot be changed by SysSockSetIpAddressAndNetMask()" Therefore I try to stop dhcpcd and flush the eth0 like this VAR CONSTANT flushIP:STRING:='sudo ip addr flush dev eth0'; stopDHCP:STRING:='sudo systemctl stop dhcpcd'; END_VAR SysProcessExecuteCommand2(pszCommand:=stopDHCP, pszStdOut:=stdout,udiStdOutLen:= SIZEOF(stdout),pResult := ADR(Result)); SysProcessExecuteCommand2(pszCommand:=flushIP, pszStdOut:=stdout,udiStdOutLen:= SIZEOF(stdout),pResult := ADR(Result)); Besides losing the connection when flush occurs the CODESYS halts, seen on the display and I cannot see why, because I have lost the connection from my IDE. Why does the flush command halt the execution of the application?
Last updated: 2025-11-04
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
The machine I'm currently using (Celeron J1900) already has the Kernel RT patch. I checked the performance according to the documentation. After running CyclicTest for 4 cores, the value for each core is around 6-7. I went through the entire process according to the documentation (I envy the TaskMonitor results in the documentation). The documentation states: "CODESYS Virtual Safe Time Provider The CODESYS Virtual Safe Time Provider is a standard interface that the user can use to transfer a second and external time base to the CODESYS Virtual Safe Control. The implementation is done as a client, which must run on another system with an independent time base." How do I implement this? I've been struggling for two weeks now - I'm too old to give up.
Last updated: 2025-11-17
Post by msirotkin on EtherCAT status errors
CODESYS Forge
talk
(Post)
Hello, I'm trying to understand the reason for the many errors on the EtherCAT master status page. If we set the cycletime to 1ms we see a lot of rxerrors and lostframes, but the send and recive times are quite good (see attachement). And the status of the EtherCAT bus is good (no other errors, all is green, slave has no errors) But when we set 2ms cycletime the lostframe errors are gone, but periodically increses rxerror counter (see attachement). The questions is, what do these errors actually mean and what we can do to get gid of them? Linux RT, imx8, Codesys runtime for ARM 3.5.21.10, Ethercat 4.10 Thanks
Last updated: 2025-11-25
Post by jbcregen on Accessing parameters from a structure or function block with the web interface
CODESYS Forge
talk
(Post)
I have a project with hundreds of OPC-UA variables available on the network. A lot of these variables are used actively in various scripts that run in background in the OS (Linux). I'm experimenting with Automation Server and I have a hard time understanding how the web interface populates its parameters list for a given PLC (<plc details="" parameters="" for="" plc="" 'xyz'="">).</plc> In this page, it looks like the only variables available are the ones that are of a "base" type : bool, TIME, String, INT, etc. All the variables that are nested into function blocks or structures are not available in the web interface, even if they are available to any OPC-UA client. Is this a limitation of the Automation Server or is there something that can be done in Codesys?
Last updated: 2025-12-01
Post by tali on Configuration of disabled/deactivated visu elements
CODESYS Forge
talk
(Post)
would be great to have such fucntionality. Sometimes it is not clear for user which elemetns are blocked and which are not - the greyed out eleemtns are not so different for low resolution / low quality screeens. What I have in my mind as well is to have a possibility to detect the visu Element clicked on and get its Access Rights. If it is blocked/deactivated, the dialog can be rised with INFO 'please login first with proper rights'. It is possible now to have a Mose event Handler ( Examples -> EventHandler) and rise the dialog out of ST (Exapmpals -> ST Dialogs). I am struggling still with getting the separate Visu Element under the mouse and its structure info
Last updated: 2025-12-05
Post by mait-tim on Drive communication errors
CODESYS Forge
talk
(Post)
With a machine I'm working with i get a communication error when I'm updating some softstop limits. As soon as I update the code the drives do not want to operate. Using the MC_readStatus I'm receiving errors as soon as i want to start a movement. Using MC_ReadAxisError i see that i receive error 131, no response. With a SMC3_ETC_ReadParameter_CoE i do not recieve any driver errors. Does anyone know how i can figure out what the error is and how to solve it. When i go back to the old software no errors occur. Im working with a legacy machine running a Beijer PLC with some Mitsubishi drives. running on Codesys 3.5 SP10. the runtime version is probably 3.5.3. The drives are all Ethercat Drives (CoE). All using the SM3_drive_ETC libary and the SM3_basic library.