Post by jy77812 on MC_MoveCircularAbsolute Using Help
CODESYS Forge
talk
(Post)
Dear People Iām trying to draw a circle using MC_MoveCircularAbsolute, but I keep encountering an error. The error message is SMC_CP_CIRCLE_CENTER_NOT_ON_BISECTOR. What Iām trying to do is simply draw a circle with a diameter of 20, starting from the point X=0, Y=0. Iāve set CircMode to center. It seems like a simple task, but the error keeps occurring, and itās giving me a headache. Iād appreciate your help. Iāve also attached the program, so please provide any advice you can. I want to use the mode as the center. I've tried changing multiple coordinates and it won't run. Please help. sample stCirculAuxPoint.c.X := 20; stCirculAuxPoint.c.Y := 10; stCirculEndPoint.c.X := 20; stCirculEndPoint.c.Y := 30; fbMoveCircularAbsolute( AxisGroup := AxisGroup, Execute := xGroupCirculEx, CircMode := SMC_CIRC_MODE.CENTER, AuxPoint := stCirculAuxPoint, EndPoint := stCirculEndPoint, PathChoice := 0, Velocity := 50, Acceleration := 50, Deceleration := 50, Jerk := 50, CoordSystem := SMC_COORD_SYSTEM.MCS, BufferMode := 0, TransitionMode := 0, TransitionParameter := , OrientationMode := , VelFactor := , AccFactor := , JerkFactor := , TorqueFactor := , Name := , Done => , Busy => , Active => , CommandAborted => , CommandAccepted => , Error => , ErrorID => , MovementId => );
Last updated: 2025-06-04
Post by erictur on CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC
CODESYS Forge
talk
(Post)
UC3100 comes with Arm Cortex-A8 1 GHz and belongs to Moxa Industrial Linux 1 (Debian 9) for Arm-based Computers. I tried to install the CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC. Unfortunately, the Third-party requirements: - libc >= 2.27 (required by CodeMeter Runtime) of the CODESYS Control for Linux ARM SL cannot be met on the Debian 9, which comes with glibc 2.24. I read the post by @johnlee (Getting Start with Codesys Control for Linux SL) (https://forge.codesys.com/forge/talk/Runtime/thread/0a515ced3f/). Where he discusses installation of CODESYS Control for Linux ARM SL on Debian 9. There was CODESYS Linux runtime v3.5.14 availble and it was successfully intalled on the Debian 9. However, the CODESYS Store has the oldest version V4.1.0.0 32 bit available. There is no way to find the CODESYS Linux runtime v3.5.14. So is there any work around for this? Or I cannot install the CODESYS Runtime on any of the Moxa IPCs based on the Moxa Industrial Linux 1 (Debian 9)?
Last updated: 2025-07-10
Post by ph0010421 on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08
Post by chalk on No source code available
CODESYS Forge
talk
(Post)
Hello, This is my first time using Codesys, I am trying to add EtherNetIP communication to a Raspberry PI. Iāve added the EtherNetIP Adapter configured the network setting and added some modules to the pi but when I download the project it generates the following error: āThere is no source code available for the object because it is in the compiled library ācip object, 4.5.1.0 (3s ā smart software solution gmbh)ā. Do you want to browse for the original library in order to display the source code? There are 2 errors in the log which are: SOURCEPOSITION App=[Application] area=3, offset=332760 EXCEPTION [Application] occurred: App=[Application], Task=[ENIPAdapterServiceTask] I canāt for the life of me work out how to get around this. I canāt find the source code anywhere or any information regarding this error. Iām using Codesys V3.5 SP19 Patch 3, the version of the Ethernet adapter is 4.5.1.0 and the version of the modules is 4.1.0.0. Any help on this will be greatly appreciated. Thanks
Last updated: 2024-02-02
Post by danieldiaz on Problem with FB execution
CODESYS Forge
talk
(Post)
Hello everyone, I've been working on a system which needs an error function, with this purpose I've created a FB programmed in LD, after debugging I run the simulation. It seems that the variable linked to a coil doesn't change the value when the contacts are associated to input variables. When I use internal variables the logic works properly. I don't know if the problem is related to the variables definition or with the logic program. As you can see in the image, I1 and I2 are variables declared on the FB, the rest are input variables. If I force the eStop and Reset signals to TRUE the coil value should change, but it doesn't. However in the second network if I1 is TRUE the coil change to TRUE as it has to be. To sum up, my doubt is why that coil doesn't change its value? I would like someone to shed a light on this. Thanks!
Last updated: 2024-04-02
Post by alexgooi on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi Duvan, You could make this in 1 single object (FB), Indeed don't use a function for this beacuse you need some memory to keep the old value. For i := 0 TO 200 BY 1 DO //Check if the value has been changed IF Old_Value[i] <> Value[i] THEN //Set the trigger to TRUE Trigger[i] := TRUE; Old_Value[i] := Value[i]; END_IF END_FOR If you define the Value array as an In_Out and the Trigger as an In_Out you arn't claiming any aditional memory to your system. You ofcourse then need to add some code arround it that does something with the trigger and writes it back to FALSE again. If you want more flexability you also could use pointers instead of using the IN_OUT FOR i := 0 TO 200 BY 1 DO address := address_Input + i * SIZEOF(*Put type here); IF Address^ <> Old_Value[i] THEN Trigger[i] := TRUE; Old_Value[i] := Address^; END_IF END_FOR
Last updated: 2024-04-02
Post by culius on JSON
CODESYS Forge
talk
(Post)
Hey guys, I am trying to write a JSON. First time after login in PLC after download everthing works. But when I want to change values during runtime and try to recreate the JSON nothing happens. When forcing the xStart as an impulse i want to recreate it and see 2 as Key3 instead of 1 from the first run. Any Idea how to make this work? PROGRAM test VAR factory : JSON.JSONDataFactory; eDataFactoryError : JSON.FBF.ERROR; pJsonData : POINTER TO JSON.JSONData := factory.Create(eError => eDataFactoryError); fb_JBuilder : JSON.JSONBuilder; wsValue : WSTRING; diRootIndex, diObject1Index : DINT; iValue : INT; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; END_VAR IF xFirst THEN fb_JBuilder(pJsonData := pJsonData, diRootObj => diRootIndex); wsValue := "Value1"; fb_JBuilder.SetKeyWithValue("Key1", wsValue, diParentIndex := diRootIndex); diObject1Index := fb_JBuilder.SetKeyWithObject("Key2", diParentIndex := diRootIndex); iValue := iValue + 1 ; // -----------!!! secound run should increment key3!!!!------------ fb_JBuilder.SetKeyWithValue("Key3", iValue, diParentIndex := diObject1Index); xFirst := FALSE; END_IF jsonArrayWriter(xExecute := TRUE, pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE); Kind Regards
Last updated: 2024-04-30
Post by hanoues on setting date and time on CPX-E
CODESYS Forge
talk
(Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21
Post by cmj-icsys on Custom configure tab in device editor
CODESYS Forge
talk
(Post)
Hi everyone, Iām developing a custom CODESYS I/O driver for my companyās device, and Iāve been studying the example projects in CODESYS V3.5 SP20 Patch 5. In the IOMappingExample.project, I noticed that EtherCAT devices provide additional configuration tabs in the Device Editor, such as General, Process Data, etc. However, for custom I/O driver examples (based on IoDrv), the Device Editor only shows the default tabs like <devicename> I/O Mapping or <devicename> Parameters.</devicename></devicename> Iād like to create custom tabs or configuration pages in the Device Editor (e.g., āGeneral Settingsā, āCommunicationā, etc.) to allow users to configure parameters in a more structured way. Could anyone explain: How to define and register custom tabs or UI pages in the Device Editor? What tools or SDKs are needed to create UI elements such as combo boxes or check boxes? How to bind those UI controls to device parameters defined in the XML (device description)? Any example, SDK reference, or documentation link would be really helpful. Thanks in advance!
Last updated: 2025-10-20
Post by raghusingh77 on $100 off Temu Coupon Code ACU934948 for new and existing customers
CODESYS Forge
talk
(Post)
The Temu coupon code ACU934948 provides a variety of discounts for both new and existing users in October 2024. Hereās a breakdown of the offers available: Flat $100 Off: New users can redeem a flat $100 discount on orders over $100 by using the code ACU934948 at checkout. 30% Additional Discount: This coupon also grants an extra 30% off on select items, making it an attractive deal for shoppers. New User Discounts: First-time users can enjoy savings of up to 75% off their initial purchase when applying the coupon. 30% Off Temu Coupons, Promo Codes + 25% Cash Back [ACU934948] Redeem Temu Coupon Code [ACU934948]. TEMU COUPON $100 OFF [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS [ACU934948] TEMU COUPON $100 OFF FIRST ORDER [ACU934948] TEMU COUPON $100 OFF REDDIT [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS REDDIT [ACU934948] TEMU COUPON $100 OFF NEW USER [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS 2024 [ACU934948] TEMU COUPON $100 OFF CODE [ACU934948] TEMU COUPON $100 OFF FIRST ORDER FREE SHIPPING [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FREE SHIPPING USA [ACU934948] TEMU COUPON $100 OFF HOW DOES IT WORK [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS CANADA [ACU934948] TEMU COUPON $100 OFF 2024 [ACU934948] TEMU COUPON $100 OFF FOR NEW CUSTOMERS [ACU934948] TEMU COUPON $100 OFF CANADA [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FIRST ORDER [ACU934948] TEMU 100 OFF COUPON BUNDLE [ACU934948] 100 COUPON CODES [ACU934948] 1 BUCKS TO PHP [ACU934948] IS THERE A COUPON IN THE PHILIPPINES [ACU934948] 100 BUCKS TO PHP [ACU934948] TEMU $100 OFF COUPON [ACU934948] TEMU $100 OFF CODE [ACU934948] TEMU 100 VALUE COUPON BUNDLE [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FREE SHIPPING [ACU934948] TEMU 100 OFF COUPON CODE LEGIT [ACU934948] TEMU 100 OFF COUPON CODE REDDIT [ACU934948] TEMU 100 OFF COUPON CODE FOR EXISTING USERS [ACU934948] TEMU 100 OFF COUPON CODE UK [ACU934948] TEMU COUPON CODE $100 OFF FREE SHIPPING [ACU934948] TEMU COUPON CODES 100 PERCENT OFF [ACU934948] WHAT IS A HIGH COUPON RATE [ACU934948] HOW TO CALCULATE COUPON RATE WITHOUT COUPON PAYMENT [ACU934948] WHAT IS THE COUPON RATE [ACU934948] HOW TO CALCULATE COUPON VALUE [ACU934948] USING COUPONS AND REBATES TO LOWER THE PRICE OF AN ITEM IS AN EXAMPLE OF [ACU934948] TEMU 100 DOLLAR OFF COUPON [ACU934948] DOMINOS COUPON CODE 100 OFF [ACU934948] DOMINO'S 100 RS OFF COUPON CODE [ACU934948] TEMU COUPON $100 OFF EXISTING CUSTOMERS [ACU934948] WHAT IS 10 OFF 100 DOLLARS [ACU934948] 100 OFF PROMO CODE [ACU934948] 1 CASHBACK ON 100 DOLLARS [ACU934948] IS TEMU 100 OFF COUPON LEGIT [ACU934948] TEMU COUPON $100 OFF [ACU934948] TEMU COUPON $100 OFF LEGIT [ACU934948] Temu Coupon Code $100 OFF [ACU934948] Potential for Up to 90% Off: Some promotions indicate that new users might save as much as 90% off on certain items, depending on the selection. Rewards Program for Existing Customers: Existing users can take advantage of the Temu Rewards Program, which may include additional discounts and cash-back offers when using the coupon code. Bundle Offers: The coupon may also be part of bundle deals that provide further discounts, such as up to 70% off on specific products. This combination of offers makes Temu an appealing choice for both new and returning customers looking to maximize their savings.
Last updated: 2024-10-26
Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon
CODESYS Forge
talk
(Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20
Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4
CODESYS Forge
talk
(Post)
Hi, I wanted to use the Adafruit Hat for the Raspberry and get acquainted with Softmotion using servos for RC models. This did work great with Codesys 3.5.19 Patch 1, but with Patch 4 and 5 i get errors. I suspect changes in the SoftMotion library have broken dependencies in the legacy drivers, might that be true? Thanks for any hint, spiessli Here the error log: ------ Ćbersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Ćbersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download mƶglich
Last updated: 2023-12-19
Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4
CODESYS Forge
talk
(Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Ćbersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Ćbersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download mƶglich
Last updated: 2023-12-20
Post by jickisticki on Witch library?
CODESYS Forge
talk
(Post)
Crafting my Fellowship Personal Statement was like weaving the threads of my aspirations into a tapestry of words. Each sentence became a brushstroke, painting a vivid portrait of my journey and ambitions. Beyond being just a document, it became a mirror reflecting the depth of my experiences. Like a conductor guiding an orchestra, my personal statement was composed to resonate with my unique voice. In the realm of specialized opportunities, this statement serves as a compass, guiding me toward the next chapter of my professional growth. With each word, I felt the guidance of mentors shaping my story into an eloquent narrative.
Last updated: 2023-08-17
Post by ofey on Modbus TCP communication
CODESYS Forge
talk
(Post)
Hi! I tried setting up the PLC I'm working with (Beijer GN-9373) to connect to a modbus master running on a laptop. I have an ethernet connection (via USB-C to ethernet) between the laptop and the controller. I have tried following tutorial on how to set this up. I have added an ethernet device with the IP-address of the PLC. Further I added a ModbusTCP_Slave_Device with default settings. I get the error "Failed to open TCP Port: 1" when I try to go online with the PLC. Earlier I tested the exact same set up with the soft PLC from codesys. I can then read/write values correctly with the Modbus master i have running on the laptop. Hope anybody can help me with this, thanks in advance!
Last updated: 2023-10-06
Post by matthew on New Ladder Editor Issues
CODESYS Forge
talk
(Post)
Hi There, When using the new ladder editor there is no option for function blocks to Remove uncalled FB call parameters. I also see no update function block. When you double click the function block it no longer opens the function block. I also now get warnings if I insert FB call without a contact in front. Warning is: (Impl)): C0373: Expression or part of it has no effect I take it the new editor must work differently? The only reason for using new ladder editor is the ST execute/block editing is far better, If you have alot of text in the old ST execute the editor window is very small and when online it's even worse. The new ST block seems a lot better Thanks!
Last updated: 2023-10-10
Post by simotion on Pointer to Softmotion axis
CODESYS Forge
talk
(Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25
Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
I'm getting closer to the error. The combination of STRUCT and ARRAY probably causes the strange behavior. As soon as the ARRAY is followed by a variable, the problem arises. Examples: X: ARRAY[1..2] OF INT; // okay Y: ARRAY[1..2] OF STRUCT; // problem Z: STRUCT; Z.ArrayOfInt[1]; // okay Z.ArrayOfStruct[1].Variable // problem // *update - array of array also causes the error A: ARRAY[1..2] OF ARRAY[1..4] OF BOOL; // problem I can't be the only one who has this problem. Or? Maybe there is a solution. Anyone? Or is it a bug after all?
Last updated: 2023-11-17
Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state?
CODESYS Forge
talk
(Post)
Hi there, I'm running the Codesys runtime on Windows 64 and I need to know if it is on "Running" or "Stopped" state just after a system crash. The following commands works perfectly well to (re)start it... net stop āCODESYS Control Win V3 - x64" net start āCODESYS Control Win V3 - x64" ...however I'm unable to determine when it is required to be call; I mean, by checking the System Tray icon, it is possible to know if it is on "Stopped" state, but I wanted to run a .BAT command to retrieve it. How can we do that?
Last updated: 2024-07-02
Post by naks on Change IP address from IEC code
CODESYS Forge
talk
(Post)
Hi, I'm working with wago 750-8212 controller. I want to change the IP address of the Ethernet adapter from webvisu. I have read some other threads in this forum and I have tried the following: Added the following text to the config file CODESYSControl.cfg: [SysSocket] Adapter.0.Name="br1" Adapter.0.EnableSetIpAndMask=1 Used the below code : IF xUpdateEthernet THEN Ethernet.Enable := FALSE; Reconfig ( xExecute := TRUE, itfNode := Ethernet, eError => ErrorReconfig, xBusy => xBusy, xDone => xDone, xError => xErrorReconfigure); IF Reconfig.xDone THEN ErrorCode := Ethernet.UpdateConfiguredIPSettings(IpAddress := NewIp, gateway := newGateway, subnetmask := newSubnetmask); END_IF IF Reconfig.xDone OR Reconfig.xError THEN reconfig(xExecute := FALSE); END_IF Ethernet.Enable := TRUE; Reconfig(xExecute := TRUE, itfNode := Ethernet ); END_IF I could change the IP address but when i restart my Controller then the IP address resets to the original, Is there anything I have missed, what else can i try ? Thank you in advance.
Last updated: 2024-07-08
Post by lorenzo-pisoni on SysProcessExecuteCommand
CODESYS Forge
talk
(Post)
Hello, I'm encountering an issue with the Sysprocess library while attempting to execute commands to transfer a file from a NAS to my PLC. Currently, I'm trying to test a simple "reboot" command, but it doesn't work as demonstrated in this video: https://youtu.be/77c7Af5xRhE?si=uFZdB6fTNQitzWMQ. I'm using CODESYS V3.5 SP18 Patch 4 (3.5.18.40). From other sources, I've learned that to enable the PLC to execute commands, I need to add the following line to the file CODESYSControl_User.txt: [SysProcess] Command=AllowAll However, the issue I'm facing is that this file doesn't exist on my CPU. I have full SSH access and can see all files, but only CODESYSControl.txt is present. Adding the command to CODESYSControl.txt hasn't resolved the problem.
Last updated: 2024-07-11
Post by hyys12 on How to use/create SOTU in LD program
CODESYS Forge
talk
(Post)
I am trying to make a LD program for an existing installation with a motor. Here an inductive sensor is used to give an input, as a check to verify the conveyor is actually running. Here the plan was to use a TOF timer which gets constantly reset when the sensor input gets detected. The problem is, that if the conveyor is stuck, and the sensor sends a continous signal, the timer will never do what it is supposed to do. Therefor I need some help on how I can convert the input to a pulse, with the help of something like a SOTU. I just cannot find this in codesys anywhere.
Last updated: 2024-07-11
Post by drml on How to implement an interface (IElement)?
CODESYS Forge
talk
(Post)
I'm struggling with the implementation of the IElement interface (in the ElementCollections library), which I will use to create a SortedList. I created a class (FB) "Device" that implements this interface and that has a "Priority" property that I want to use in order to compare the devices in my implementation of the ElementCompareTo method. Unfortunately, the IElement.ElementCompareTo method needs an IElement as an input, which doesn't know about the "Priority" property of "Device". I tried to define the input itfElement as a Device, but then it doesn't want to compile, because the type in the implementation doesn't match the interface.
Last updated: 2024-07-19
Post by peterned on Programatically restart Codesys OPC UA server?
CODESYS Forge
talk
(Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19
Post by c3po on SNMP Communication with WAGO 750-8212 PFC
CODESYS Forge
talk
(Post)
Hello folks, my problem is a bit bigger for just one question. So let's start with the easiest. But first, my system setup: It's a WAGO 750-8212 PFC with some I/O-modules. I try to communicate with the controlsystem over SNMP using the IIoT library from codesys. https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_iot_snmp_service.html Is there some expirience with this kind of communication? It's just about transfering some data from PFC to network and setting some analogsettings from network to the PFC. So my easiest question: Do I ever need the SNMP_Agent or can I use the SET / GET function as standalone, without the agent? (maybe some more questions will follow, if someone will answer to my request) thanks so far
Last updated: 2024-08-21