Post by talhaali on Create an alarm list without use of Alarm config
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Create an alarm list without use of Alarm config
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by mozed on Windows 11 and SP17
CODESYS Forge
talk
(Post)
Try to use this version: https://store.codesys.com/de/codesys-installer.html
Last updated: 2024-06-12
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I have a Raspberry Pi 4 we have been using for years to run CODESYS for development purposes. I recently have had to re-install the OS (Raspberry OS lite). The only change to the default configuration is not creating the "pi" user during install. I (apparently successfully) installed the 4.10.0.0 control on the Raspberry Pi. We have licences on a dongle. I am able to start the control. systemctl status shows it as running for a little while (exactly, precisely 30 seconds as per my tests, every time), then it becomes exited. I can restart the control, and the same thing happens again. Every time. In the brief moments it is running, I can log in to the PLC. Working fast and restarting the control many times, I have been able to configure users. I have been able to download my application. I have been able to run the application, and stop on a breakpoint. I have been able to connect with the licence manager and confirm the dongle is detected and licences are listed as OK. I see nothing wrong until the service just exits. I have found nothing in the logs. It is like the runtime just terminates with no error code or message after exactly 30 seconds. Any help would be appreciated.
Last updated: 2024-06-13
Post by thieulam on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive
CODESYS Forge
talk
(Post)
ok. tnx! best regards.
Last updated: 2024-06-19
Post by thieulam on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive
CODESYS Forge
talk
(Post)
Last updated: 2024-06-19
Post by timvh on Toradex and CODESYS and licensing
CODESYS Forge
talk
(Post)
For the Virtual Control you need to use a "Network license". The Virtual Control has parameters of which one is the reference to the license server. This can be the device itself, but you need to activate the license on the host system (not in the container). For this, CODESYS has a Network License server with WBM (web based management). See for the Network License configuration: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_license_controller_linux.html If it is only for evaluation, I would advise to use a CODESYS (USB) key and activate the license on the key. Then you still have to install the CODESYS Network License server on the host, but you don't have to activate the license as soft license on the device. The benefit is that you can easily move your license to another device when needed. Off course your device must have a free USB port available to be able to do this.
Last updated: 2025-10-20
Post by eschwellinger on Toradex and CODESYS and licensing
CODESYS Forge
talk
(Post)
yes, need to be plugged.
Last updated: 2025-10-21
Post by timvh on Errors after moving from SP18 to SP20/21
CODESYS Forge
talk
(Post)
have you tried: VisuElems.VisuStructClientData ?
Last updated: 2025-10-22
Post by dinesh-vamtec on SysProcessExecute
CODESYS Forge
talk
(Post)
I'm trying to open the Help.chm file in CodeSys ST, not working.
Last updated: 2025-10-24
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
My MC_Phasing FB was stuck in iPhasingState=1 and error output HIGH on one axis. I could manually overwrite the state to 0 in the instance data. During normal run I see the state change from 0 to 10 to 100 back to 0 (maybe more states that I couldnt catch with the naked eye) But - what are the states numbers and their different explenations? This is not explained in the FB guide on codesys. (the pictures show state = 0 after I reset)
Last updated: 2025-11-22
Post by bertus on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Thanks. I will do more investigation and testing next week.
Last updated: 2026-01-02
Post by timvh on Deploy Codesys Control SL to a 'secure' device
CODESYS Forge
talk
(Post)
Runtime version SP22 is an LTS version.
Last updated: 1 day ago
Post by timvh on KeyPad Function in Visualization to fill a table
CODESYS Forge
talk
(Post)
Create an array of STRING and 1 INT variable, e.g.: asMyString : ARRAY[0..9] OF STRING; iIndex : INT; Then place a "Table" object in the visualization: - link this to the string array variable. - Check the option "Use Template" - Then in the Input Configuration - add the "Write Variable" command Somewhere else add a "Combobox, array" - link this to the same array. - And link the index to the INT variable. In the Combobox, you can then select one of the strings from the array. The index variable will indicate which selection has been made.
Last updated: 2026-01-08
Post by osande on V3.5 SP22 Patch1
CODESYS Forge
talk
(Post)
Compilation fault according to file. Anyone. Worked fine with SP21 P5..
Last updated: 2026-05-02
Post by nz-dave on *exception* [processorloadwatchdog] occurred in: app=[all], task=[all]
CODESYS Forge
talk
(Post)
Can anyone shed some light on this issue im having. at random, sometimes days, sometimes weeks or months. i get this error and have to reset the plc. Im using a Weintek HMI with ethernet/ip remote io and vsd. i have tried increasing my task times and watchdogs. and when i view my PLCload in the shell its normally around 3-4%, highest ive ever seen is 7%. Nothing i do seems to help the issue. Could the HMI's Codesys CPU be getting to hot do to high ambient temp?
Last updated: 2026-02-01
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Does this cover what you need?
Last updated: 2026-02-17
Post by a-simone on Unable to install previously installed version
CODESYS Forge
talk
(Post)
Same problem, someone solved it?
Last updated: 2026-02-20
Post by sulzbrunn on Codeys Installation freezes while attempting to install packages
CODESYS Forge
talk
(Post)
ok, after 33 minutes it contiuned - Solved
Last updated: 2026-03-19
Post by tomstix on JSON_Utilities_SL JSONFileWriter error NULL_POINTER
CODESYS Forge
talk
(Post)
Hi, did you ever find an answer to this?
Last updated: 2026-04-09
Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
Hello, my PFC200 has run for a few month now without problems. But now it freezed 2 times a day. LEDs were green but the PLC was not reachable. After power off -> on. I found that the MQTT had an error: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED. And MQTT hadn't reconnect since then. I tried a cold and a warm reset but nothing helped. How can I solve this? Regards, Paul
Last updated: 2023-09-21
Post by reinier-geers on Energie price
CODESYS Forge
talk
(Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03
Post by reinier-geers on Energie price
CODESYS Forge
talk
(Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03
Post by helcioburd on How long can a WSTRING be in CodeSys V3?
CODESYS Forge
talk
(Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02
Post by ganassa on Custom colors in Ladder diagrams?
CODESYS Forge
talk
(Post)
How can I change the default color - blue - for active lanes, contacts and coils? I'd like a lighter color. After having failed in finding a related option in the IDE, I've looked at the "Default.editortheme" file in CODESYS' directory, but couldn't see any related option. Thank you
Last updated: 2025-07-09