Post by k4zz on Scripting static code analysis
CODESYS Forge
talk
(Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18
Post by patrik on CODESYS Control for Raspberry Pi SL on Raspberry Pi 4b
CODESYS Forge
talk
(Post)
Hi! I'm 99% sure I'm running CoDeSys on a raspberry pi 4b. just be aware that there is a separate license for running it on multiple cores. https://store.codesys.com/en/codesys-control-for-raspberry-pi-mc-sl.html
Last updated: 2023-09-05
Post by eschwellinger on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
ok now it is clear - this is a single core Pi Zero W. For this device there is no edge device available. But just for working with CODESYS it is not really needed and yes plc runs only for 2h unlicensed.
Last updated: 2023-09-13
Post by dekelec on Codesys 2.3 & Peak PCAN
CODESYS Forge
talk
(Post)
IF you have an USB interface type in "Peak_USB" for CAN card driver (Name of CAN card driver). No need to add libraries for communication via CoDeSys Gateway. For other card types contact PEAK support and they will help you. Regards,
Last updated: 2024-07-08
Post by andreiot40 on Step motor ECT60 Ethercat in codesys 3.5
CODESYS Forge
talk
(Post)
Thanks for your response. for Master in log i have : no slaves found, Interface could not be opened, could not open network adapters. Status : Not running FOR ETC60 There is nothing !!!
Last updated: 2024-08-15
Post by ryusoup on OPC UA Client certificate for datasource link
CODESYS Forge
talk
(Post)
Hello, I'm looking for a way to set my client certificate, not one which self-signed cert generated with CODESYS, for OPC UA connection via datasource linking. Does anyone know how to archive that? BR,
Last updated: 2024-03-08
Post by alex2 on Codesys SVN
CODESYS Forge
talk
(Post)
Thank you for your answer. So i assumed correctly... And yes thats pretty expensive... Having to pay that much only for SVN / Git. we will look for that.
Last updated: 2024-04-29
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Downloaded and installed edge gateway 4.19.0.0. Unfortunately same behavior: "Control for Linux SL" NOT shown in drop lists on either "Deployment" Tab of tool "Deploy Control SL", or as "installed packages" on "Operation" tab (only "CODESYS Edge Gateway for linux" is shown).
Last updated: 2026-02-16
Post by yannickasselin on MQTT QoS 1 & 2
CODESYS Forge
talk
(Post)
Hello, After some more tests, here is what I found out. It seems we have to increase the uiKeepAlive and tPingInterval parameters. If I increase the uiKeepAlive value to 60s and the tPingInterval to 30s, then if I disconnect the ethernet cable from Codesys and publish some messages to which Codesys subscribes to and then reconnect within 30s, I will get the messages. If I don't reconnect the cable within 30s (ping interval), the client goes in error with "ACKNOWLEDGE_TIMEOUT". When this happens, it will not automatically reconnect after reconnecting the cable. I have to disable and re-enable the client but I will not get the published messages. I need to do more tests because there are a lot of weird things happening when playing with the ping interval and the keep alive. It is not clear to me what does what. I even ended up not receiving messages anymore, even if I disabled and re-enabled the mqtt client. The client did not give any error. The only way I was able to get messages again was by modifying my client ID. After that, if I try to re-use one of the old client IDs, nothing works (publish, subscribe) and I get a TCP_INIT_ERROR and sometimes a TCP_READ_ERROR. I need more explanation/documentation about these weird behaviors. Maybe it is the way I use it, maybe it is related to the broker (I am using Mosquitto with default parameters). When using a Node-Red client, everything works perfectly. I am trying to achieve the same behavior with Codesys but it seems impossible so far.
Last updated: 2024-10-30
Post by nickpoon on SysProcessCreate stopped working after SP21?
CODESYS Forge
talk
(Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02
Post by deeps on web visu on IFM
CODESYS Forge
talk
(Post)
I have an IFM cr1077 display. I would like to show B&R mapp view on IFM visualization. I used coedsys web browser elemnt for this. I could see IFM working fine in Internet web browser but IFM device shows white screen and freezes. I think there is problem with IFM showing the web browser. Is my understanding of the web visu right? am I doing any mistake here?
Last updated: 2023-08-18
Post by voffi on Converting UINT into bytes and converting 2Bytes into UINT
CODESYS Forge
talk
(Post)
There are some ways. One is to use SHR and SHL and it depends on your byte order in the data array. For Motorola byte order: PROGRAM PLC_PRG VAR u : UINT; byte_array_in : ARRAY [1..8] OF BYTE := [16#11, 16#12, 16#13, 16#14, 16#15, 16#16, 16#17]; byte_array_out : ARRAY [1..8] OF BYTE; END_VAR u := SHL(TO_UINT(byte_array_in[2]), 8) + TO_UINT(byte_array_in[1]); byte_array_out[1] := TO_BYTE(u); byte_array_out[2] := TO_BYTE(SHR(u, 8)); If it's Intel byte order just change 1 and 2 in the array indexes.
Last updated: 2023-12-07
Post by mandeepahujaifm on Ethernet/IP 4.6.0 causing exceptions?
CODESYS Forge
talk
(Post)
I have experienced the same with one of our customers after updating EIP Scanner to 4.6.0.0 and really baffled by it. The core dump simply shows error with ENIPScanner I/O task and on analyzing it says no source code available for 4.6.0.0. Contemplating to go back to 4.5.1 but 4.6.0.0 has some really nice fixes. I guess it don't matter if it crashes anways. Please keep us posted if you find anything.
Last updated: 2024-07-11
Post by micik on ERR_OK not recognized
CODESYS Forge
talk
(Post)
Hello, if I try to use ERR_Ok in my code to check whether the file is open correctly or not, I get an error "Identifier ERR_OK not recognized", I can use plain 0 (zero) instead. But in general, is this a proper way to check for success of file operation since the 4th parameter is a poinmter to RTS_IEC_RESULT, and normally I would expect this to be used somehow. _hFile := SysFileOpen(_sFileName, am:=SysFile.ACCESS_MODE.AM_WRITE, ADR(_result)); IF _result <> 0 THEN udDiag := 100; RETURN;
Last updated: 2024-08-17
Post by warrumungi on Opening a Dialog on a specific Client from ST
CODESYS Forge
talk
(Post)
Hi Thanks, Manuel, for providing this solution and insight. I too had exactly the same problem as you did. While I did implement a custom filter, I'd also like to point out what jinlee mentioned above...I see no reference to VU.PublicVariables.Clients.Current anywhere?? In my case I only needed to show a dialog on a "master" client, not all the clients, so I filtered by IP address to do this.
Last updated: 2024-11-05
Post by toby on SM Drive license error
CODESYS Forge
talk
(Post)
Hi albert1999 and forest, I hope you are well. I too am wondering if you have found any solutions? Im working with a RPi and a Omron R88D-ETH servo amplifier. The SoftMotion is timing out after 30min without the license, but I cant figure out how to license it, and I seem to have some compatibility issues between my RPi license and any SoftMotion licenses. Did you guys have any luck? Thank you very much for any assistance offered. Toby
Last updated: 2024-01-10
Post by mejak on Raspberry Pi USB HID RFID Reader - read ID in plc program
CODESYS Forge
talk
(Post)
Hello, I have an RFID reader that is detected as a keyboard. While looking for information, I came across examples using visualization. I would like to read the ID without visualization or external code in python, only in PLC. I found on the forum that you can try reading directly from potru /dev/... https://forge.codesys.com/forge/talk/Runtime/thread/24b3527036/ How to read values directly in codesys? Or maybe there is another solution? Best Regards
Last updated: 2024-01-25
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I checked it using the very same docker container version like colleague moon and the command returned root@nt0001c02c5533:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. Result: 0 CmContainer(s) listed. (CodeMeter not running) Please consider that we intend to license a codesys ARM64 SL in a docker container.
Last updated: 2024-03-20
Post by dkugler on Codesys SVN
CODESYS Forge
talk
(Post)
Don't set on SVN. The service phase has started in March 2024 and will be discontinued in 2027. We actually use SVN and have to switch to GIT in the future. As I informed, there is no way of getting a single SVN or GIT licence. I' dont understand, why Codesys forces us customers to pay for an expensive Professional Edition paket from year to year using only one part of it! If you find a way to buy a single licence, let me know.
Last updated: 2024-04-29
Post by svdpoint on Raspberry Pi Zero 2W with external Ethernet adapter
CODESYS Forge
talk
(Post)
Hello all, Somebody try to run the CodeSys at RPi Zero 2W with external ETHx device? I need to more information how youi do it, what need to it, ...etc. It is interesting to use it together with EtherCat-interface. For example I had try to connect W5500 over SPI. The eth0 is present, but does not found any EtherCat IO-device. BR
Last updated: 2024-05-25
Post by rtlman on Scan devices hangs CODESYS
CODESYS Forge
talk
(Post)
Hello, I have a problem that randomly appeared today. When trying to scan a network adapter in "Deploy Control SL" the whole program hangs and needs to be restarted. I have been running "CODESYS v3.5 SP21 Patch 3" for a while and it has worked without any issues until now. I've tried upgrading to "CODESYS v3.5 SP21 Patch 4" with the same result. I've not made any system settings recently that im aware of which could cause this. Has anybody had similar a issue?
Last updated: 2025-12-12
Post by charly29160 on WebVisu scaling regression in V3.5.22 P2: frame size jumps when switching visualizations
CODESYS Forge
talk
(Post)
Environment: - CODESYS V3.5.22 Patch 2 - CODESYS Control for Raspberry Pi MC SL - WebVisu in browser Problem: When switching between visualizations using a Register element (Registerkarten), the displayed frame size jumps incorrectly after returning to a previously viewed visualization. This behavior was introduced in V3.5.22 Patch 2. The same project worked correctly in V3.5.21 Patch 4. WebVisu settings in V3.5.21 (working): - Scaling: Isotropisch - Automatisch ermittelte Clientgröße verwenden: active - All visualizations: Automatisch erkannte Visualisierungsgröße Workaround?
Last updated: 2026-06-15
Post by reinier-geers on draw 1000 nails the easy way
CODESYS Forge
talk
(Post)
Because codesys dont has a draw command like Circle in Qbasic ( 20 years ago ) i want to draw 1000 nails, and then move them in the screen when they needed. I dont know if codesys can handle this. But is ther an easy way to draw 1000 nails with every single one has a pointer for movement, color and invisable. Of is there a linux command to draw a circle so i can do it with a process command
Last updated: 2026-05-06
Post by culius on JSON
CODESYS Forge
talk
(Post)
Hey guys, I am trying to write a JSON. First time after login in PLC after download everthing works. But when I want to change values during runtime and try to recreate the JSON nothing happens. When forcing the xStart as an impulse i want to recreate it and see 2 as Key3 instead of 1 from the first run. Any Idea how to make this work? PROGRAM test VAR factory : JSON.JSONDataFactory; eDataFactoryError : JSON.FBF.ERROR; pJsonData : POINTER TO JSON.JSONData := factory.Create(eError => eDataFactoryError); fb_JBuilder : JSON.JSONBuilder; wsValue : WSTRING; diRootIndex, diObject1Index : DINT; iValue : INT; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; END_VAR IF xFirst THEN fb_JBuilder(pJsonData := pJsonData, diRootObj => diRootIndex); wsValue := "Value1"; fb_JBuilder.SetKeyWithValue("Key1", wsValue, diParentIndex := diRootIndex); diObject1Index := fb_JBuilder.SetKeyWithObject("Key2", diParentIndex := diRootIndex); iValue := iValue + 1 ; // -----------!!! secound run should increment key3!!!!------------ fb_JBuilder.SetKeyWithValue("Key3", iValue, diParentIndex := diObject1Index); xFirst := FALSE; END_IF jsonArrayWriter(xExecute := TRUE, pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE); Kind Regards
Last updated: 2024-04-30
Post by adamrobotic on llcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008
CODESYS Forge
talk
(Post)
Hi All, Recently I have been experiencing a issue in CodeSys SP16 Patch 3, with a exception which comes up after I have made several online changes. callcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008, after I experience this fault then I receive a error message for any subsequent online change "online change failed, no task gap within 10000ms". To recover either the controller needs a orgin reset, which will allow online edits thereafter until falling back into the loop. I am using a TURCK TX707 product which is controlling robot trajectory, We have hard coded the coordinate data rather than using persistence variables so hence the need to do online changes consistently. I have read on the forum other people have experienced similar issue with the online task gap, but I have no task which have same priority and also monitored the CPU usage and have not seen it go above 13%. Anyones help would be much appreciated, thankyou.
Last updated: 2023-08-18