Post by egau on Hard shutdown: no code on device after power on
CODESYS Forge
talk
(Post)
Hi, We have a machine running Codesys on a Windows IPC (CODESYS Control Win v3 - x64). When we hard shutdown the machine, the code on the PLC sometimes becomes "corrupted" after a power on (When trying to login to the PLC, we get the message "The application 'Application' does not exist on device."). I've noticed these errors in the logs, but I'm not sure what to make of them. We are not using any RETAIN variables in our code, although I'm not sure about referenced librairies. (we are using the persistence manager). I'm pretty sure that not doing a graceful shutdown is the root cause of this. This being said, what is the proper way of doing a graceful shutdown? Is putting the Codesys application in "stop" sufficient? I know how to implement this, so if it works then it would be a quick fix. However, I think we need to add a UPS, which would detect power loss and inform the PLC that it needs to initiate its shutdown, and then the PLC would shutdown gracefully. Any help with this will be greatly appreciated :)
Last updated: 2024-10-03
Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
I have a project with several buttons and dialogs. Most of the dialogs are opened using the Open Dialog action of the Input configuration of the buttons. Some dialogs are openend using the FbOpenDialogExtended FB of the Visu Utils library and the FbOpenDialogExtended FB is called in the Execute ST-Code action. I am also using the FileOpenSave dialog from Visu Dialogs which requires an OnDialogClosed action to read out. I realized that the OnDialogClosed action which is meant for the FileOpenSave dialog also triggers if a dialog is closed, which was previously openend using the FbOpenDialogExtended FB. Is there a way to detect which dialog was closed last and specify to which dialogs the OnDialogClosed action reacts?
Last updated: 2023-09-20
Mapping PLC world(code) to Hardware world(remote IO) with some OOP style
CODESYS Forge
talk
(Thread)
Mapping PLC world(code) to Hardware world(remote IO) with some OOP style
Last updated: 2017-01-19
Can't open online view of FB instance from code editor, only from Device/POU windows
CODESYS Forge
talk
(Thread)
Can't open online view of FB instance from code editor, only from Device/POU windows
Last updated: 2023-11-08
AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030
CODESYS Forge
talk
(Thread)
AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030
Last updated: 2023-11-21
Is The Temu 100β¬ Coupon A Scam? Use Verified [acr639380] Temu Code
CODESYS Forge
talk
(Thread)
Is The Temu 100β¬ Coupon A Scam? Use Verified [acr639380] Temu Code
Last updated: 2024-10-18
Temu Coupon Code North Carolina {USA} β€ ["^act900074^"] for New and Existing Customers
CODESYS Forge
talk
(Thread)
Temu Coupon Code North Carolina {USA} β€ ["^act900074^"] for New and Existing Customers
Last updated: 2024-10-25
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.