Post by simone on Collapse all CODESYS Forge talk (Post)
Hi, I'm wondering if it exist a button or a keyboard shortcut (much much better) for "collapse all" the open folder on a codesys project. It would really be nice to have. Also: Are there some options or configuration for set a default zoom for the different editor (or even one global), for example I would like to have 100% on ST, LD editor and have 80% on Visualization Editor; and also have a button to set all the zooms to default, now it seems that every file mantain the one previously set. I'm working with the 3.5.20.10 right now Thanks!
Last updated: 2024-11-21

Post by bingo on PLC Shell commands via ST Code CODESYS Forge talk (Post)
Suppose you need to switch PLC IP dynamically between 192.168.1.10\192.168.2.10, First, set PLC IP to 192.16.1.10. Create a PGVL with a flag β€˜xUseSecondry’ xUseSecondry : bool ; create a function that use socket to update IP: FUNCTION fSwitchIP : bool VAR_INPUT useMainIP:bool; END_VAR --------------------------------CODE------ if useMainIP then SysSockSetIPAddress(β€˜0’, β€˜192.168.1.10’); PGVL.xUseSecondry := 0; else SysSockSetIPAddress(β€˜0’, β€˜192.168.2.10’); PGVL.xUseSecondry := 1; end_if Now, if during execution, you need to switch IP, call the function β€˜fSwitchIP()’, Set input to 1 for main IP, 0 for secondary IP. In order to set secondary IP at startup, you can do the following: in your PLC_PRG add a flag: xInit : bool := 1 ; and the code: if xInit then if PGVL.xUseSecondry then fSwitchIP(0); end_if xInit := 0 ; end_if *Alternative way is to use system events.
Last updated: 2025-03-03

Post by dkugler on Webvisu Combined Authentication CODESYS Forge talk (Post)
you are able to do this all in one screen. It is possible to set the rights of every element to visible but not editable for the user "none". so everyone is able to see this elements, but can't do any changes. At the login button you set the rights to editable for the user "none" to be able to go to the login. Every element that should be hidden before logging in, set the rights visible and editable only for "higher" users. Hint: to change rights you are able to select more then one element and edit rights for all at the same time. Saves a lot of time! Good luck!
Last updated: 2025-09-03

Post by kevinl on RevPi Connect RS485 CODESYS Forge talk (Post)
I figured this out on my own with this logic: usually the Serial port on a Raspberry pi is on /dev/ttyUSB0 then you need to set linux.DeviceFile=/dev/ttyUSB in codesys you then must set com port to 1 so i assumed codesys subtracts 1 from the number and adds this to the filename... (in code it would look like this: var comPort : byte := '1'; linuxDevice : string := '/dev/ttyUSB'; filename : string; end_var filename := concat(linuxDevice, (to_string(comPort-1)); filaname then is /dev/ttyUSB0 RevPi uses ttyRS485 as Serial port so you must remove the last number from the name and set the com port to this number +1 i hope this is understandable ;-)
Last updated: 2023-12-11

Post by mikek10 on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
I was answering your last paragraph Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18

Post by garrian on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
Thanks for your reply. I belive it is contiguous, I'm writing to adress 0 to 4. Or, do you mean something else? Well, something is happening. If I on the client set adress 1,2,3 to true, only 1 is set to true on the server side. On the client side, the data is array of word. But on the server side, the coils are array of bool. Holding register is array of word on server side. Can this be a problem? Attached screenshot of how it looks at the server side.
Last updated: 2024-11-17

Post by timvh on JSON CODESYS Forge talk (Post)
I don't know the details of jsonArrayWriter, but the common behaviour for an xExecute input is that the FB starts on the trigger that it gets TRUE. In your case xExecute is never FALSE, so it is never triggered again to start the jsonArrayWriter. So change the condition from TRUE to a variable which you set to TRUE with the "xFirst". Then when the jsonArrayWriter is done (xDone), or has an error (xError), then set this variable to FALSE.
Last updated: 2024-05-01

Post by corriibme on Setting array values with JSON Utilities SL CODESYS Forge talk (Post)
I have been trying to set an array value to a JSON structure of this form: {"key": [1,2,3,4]} While I have been able to create the key and set its value to an empty array, I've not had any luck in putting any value in that array. objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindex); iValue2: ARRAY[0..3] OF INT:= [1,2,3,4]; The two lines of code above produce {"key6": []} . The second line essentially has no effect.
Last updated: 2024-05-12

Post by paro on "You are using inconsistent overlay settings, please check your compiler defines for the current application" error CODESYS Forge talk (Post)
Disable the setting "Support client animations and overlay of native elements" in the Visu Manager. Activating this setting should also set a compiler define (GENERATE_OVERLAY_VISU). Maybe the compiler define is set and the feature is not activated in the visu manager or or the other way round.. rightclick the Application -> Properties -> Build https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_properties_build.html
Last updated: 2024-05-29

Post by felipemsgarcia on EtherCAT - Force Control Word CODESYS Forge talk (Post)
What worked for me: Use SMC_SetControllerMode and set the nControllerMode to SMC_nocontrol. With that, you can control the drive via Modes of Operation(16#6060) and Controlword(16#6040) directly. Hope that helps, Cheers!
Last updated: 2023-08-31

Post by chris12345 on OPC UA datasource low read frequency CODESYS Forge talk (Post)
Hi yr00, the default sampling interval is set to 1s. you can generate your own client settings, this link should help you:- https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2023-09-13

Post by chris12345 on OPC UA datasource low read frequency CODESYS Forge talk (Post)
Hi yr00, the default sampling interval is set to 1s. you can generate your own client settings, this link should help you:- https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2023-09-13

Post by totorovic on Codesys Softmotion Win V3 x64 CODESYS Forge talk (Post)
You have to update the device in your IDE to 3.5.14 or you can contact your Codesys runtime supplier to know how to set the connected system to 3.5.19
Last updated: 2023-11-09

Post by murdemon on CNC Jumps G20 - SMC_NCInterpreter and long time to process CODESYS Forge talk (Post)
Best way.. in CNC program before G20 jump, set G75. And for fbCheckVel execute if fbInterpreter.bWorking AND fbInterpreter.bLastObjectWasAdministrative; and same for Interpolator. " ..... dumm := fbInterpreter.bWorking AND fbInterpreter.bLastObjectWasAdministrative; //Check velociteses. fbCheckVel(bExecute := (fbInterpreter.bDone or) dumm, bAbort := gCNC.bCycleStop, poqDataIn := fbInterpreter.poqDataOut); "
Last updated: 2024-08-03

Post by dennisyhli on Ethernet IP Connection timeout CODESYS Forge talk (Post)
I use ethernet ip scanner and the connection type is set to multicast. After running the PLC, the ethernet IP will have a connection timeout every 10 seconds. What is the reason for this error?
Last updated: 2024-08-16

Post by rmaas on Open specific Version of Codesys Control Win V3 x64 CODESYS Forge talk (Post)
Hi, When you open 'Codesys Installer' you can select which version of Control Win should be used. Select '...' at the desired version and select 'Set Control Service' Then start Codesys Control Win again...
Last updated: 2024-08-22

Post by trycyclepower on How to set unit in Axis CODESYS Forge talk (Post)
I am very new to Motion in Codesys. I have linear axis and would like to setup as mm, I want to move axis and control axis in mm, mm/s. How do I do that? I know my electronic gearing is 200000.
Last updated: 2024-08-29

Post by tk096 on How to set unit in Axis CODESYS Forge talk (Post)
Hi, you have to define how many increments of the drive correspond to one unit in your application. This is done in the Scaling/Mapping Tab in the drive editor.
Last updated: 2024-09-02

Post by docker on Webvisu client connection monitoring CODESYS Forge talk (Post)
can you send me some code snippets of the declarations and code need i am unsure of how to set the pointer to the correct visu client. Thanks i appreciate your help.
Last updated: 2024-09-09

Post by i-campbell on MODBUS TCP REGISTERS CODESYS V3.5 CODESYS Forge talk (Post)
codesys is in hex and starts at 0 your other program is set to decimal and maybe starts at 0 or 1, I can't tell.
Last updated: 2024-10-12

Post by gatto on Profinet Exor connection drop CODESYS Forge talk (Post)
did you try setup two eth ? on ethO you set ip to communicate with pc, example 192.168.0.1 on eth1 ip to communicate with weidmuler I/O, example 192.168.100.1 note : ip need the same of ip setup under system setting of hmi.
Last updated: 2024-10-16

Post by timvh on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
Most likely your IP address is set to 172.... because you use a VPN connection to your device. Probably best to use the other Ethernet interface for your modbus communication.
Last updated: 2024-10-24

Post by bingo on PLC Shell commands via ST Code CODESYS Forge talk (Post)
For a permanent change, you may need to update the PLC configuration file or set the IP at startup using retained variables.
Last updated: 2025-03-02

Post by domebruce on Which database to use? CODESYS Forge talk (Post)
I'm new on Codesys. I need to manage a large and complex data set, which database and library you suggest to use? Some application examples will be appriciated. Thanks
Last updated: 2025-03-04

Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64 CODESYS Forge talk (Post)
Resolved this. There is a config file called CodesysControl_User that I had to edit to set the driver to component 5. I deleted the semi colon next to Component.5=CmpEt1000Drv
Last updated: 2025-03-19