Post by mtho on JSON Utilities - JSON file written with invalid structure
CODESYS Forge
talk
(Post)
I'm using the JSON Utilities SL library to write configurations in my program to a file. I'm generating the JSON data using the builder function block and all appears to work correctly. When I write the jsondata to file, I'm finding that some of the JSON elements are not being written in the right location in the file. Rather than writing they keys under the parent object, they get written outside the root JSON object at the end of the file. If I then try to read the file back into the program, I get an invalid_structure error. I don't get any errors when populating the JSON data or when writing the file. I attached an example of the JSON writer output. The problems begin with key P200. Each P200 should go under MBR1 through MBR3. Among the rest of the keys, they are supposed to be under different parent objects. I am using default values for wsLineBreak and encoding.
Last updated: 2024-03-06
Post by joshskellig on Publish a JSON payload via MQTT Publish (using IIot Libraries)
CODESYS Forge
talk
(Post)
I am trying to figure out how to get a JSON payload to properly publish to my MQTT Broker. I am able to generate JSON using the examples from Codesys, but when I send that payload via MQTT there are characters that are extra or not recognized by my MQTT client. Any idea what could be causing it? PROGRAM PLC_PRG VAR hostname: STRING := 'localhost'; port: UINT := 1883; topic: WSTRING(1024) := "testing/"; payload: BYTE; factory : JSON.JSONDataFactory; eDataFactoryError : FBF.ERROR; pJsonData : POINTER TO JSON.JSONData := factory.Create(eError => eDataFactoryError); fb_JBuilder : JSON.JSONBuilder; wsValue : WSTRING := "Value1"; diRootIndex, diObject1Index : DINT; iValue : INT := 1234; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; mqttClient: MQTT.MQTTClient; mqttPublish: MQTT.MQTTPublish; mqttPublishProperties: MQTT.MQTTPublishProperties := (bPayloadFormatIndicator := 1, wsContentType := "application/json"); END_VAR // Json Functionality IF xFirst THEN fb_JBuilder(pJsonData := pJsonData, diRootObj => diRootIndex); fb_JBuilder.SetKeyWithValue("Key1", wsValue, diParentIndex := diRootIndex); diObject1Index := fb_JBuilder.SetKeyWithObject("Key2", diParentIndex := diRootIndex); fb_JBuilder.SetKeyWithValue("Key3", iValue, diParentIndex := diObject1Index); xFirst := FALSE; END_IF jsonArrayWriter(pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE); MSU.StrTrimW(pString:= ADR(wsJsonData)); // MQTT Functionality mqttClient( sHostname:=hostname, uiPort:=port, eMQTTVersion:=MQTT.MQTT_VERSION.V5 ); mqttPublish( mqttClient:=mqttClient, pbPayload:=ADR(wsJsonData), udiPayloadSize:=SIZEOF(wsJsonData), wsTopicName:=topic, mQTTPublishProperties:=mqttPublishProperties );
Last updated: 2024-04-10
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by culius on JSON
CODESYS Forge
talk
(Post)
Hey guys, I am trying to write a JSON. First time after login in PLC after download everthing works. But when I want to change values during runtime and try to recreate the JSON nothing happens. When forcing the xStart as an impulse i want to recreate it and see 2 as Key3 instead of 1 from the first run. Any Idea how to make this work? PROGRAM test VAR factory : JSON.JSONDataFactory; eDataFactoryError : JSON.FBF.ERROR; pJsonData : POINTER TO JSON.JSONData := factory.Create(eError => eDataFactoryError); fb_JBuilder : JSON.JSONBuilder; wsValue : WSTRING; diRootIndex, diObject1Index : DINT; iValue : INT; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; END_VAR IF xFirst THEN fb_JBuilder(pJsonData := pJsonData, diRootObj => diRootIndex); wsValue := "Value1"; fb_JBuilder.SetKeyWithValue("Key1", wsValue, diParentIndex := diRootIndex); diObject1Index := fb_JBuilder.SetKeyWithObject("Key2", diParentIndex := diRootIndex); iValue := iValue + 1 ; // -----------!!! secound run should increment key3!!!!------------ fb_JBuilder.SetKeyWithValue("Key3", iValue, diParentIndex := diObject1Index); xFirst := FALSE; END_IF jsonArrayWriter(xExecute := TRUE, pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE); Kind Regards
Last updated: 2024-04-30
Post by rk-gaw on Unhandled exception and refactoring error
CODESYS Forge
talk
(Post)
Hello everyone. I hope this is the right place to ask for help, this error is causing me a great amount of time loss and I really would like to end this nightmare. I don't know why but at times if I try to Browse -> Display Cross Reference on a variable Codesys just crashes. I'll attach the file with the complete crash report hoping someone can figure why it happend. I think that the unhandled exception comes from the PersisranceManager Module and is connected with the other big problem I'm facing: I cannot refactor in my project, if I'll try to refactor a POU name the whole POU will become "frozen", it's like its desynchronizing from the project and the project cannot find the pointer to the POU once I refactor it. And when I open the project a warning pop-up will show up with the frozen POUs name, but I cannot figure out what the warning is telling me. I'll attach every warning and error pop up the project is showing me, and thanks in advance to anyone who can figure something out.
Last updated: 2025-12-10
Post by pernockham on How to recognize licenses SMALL, MEDIUM, LARGE by CmpCodemeter
CODESYS Forge
talk
(Post)
Im trying to read out active license by CmpCodeMeter but am not sure of the combination of ProductCode and FeatureMap that each of CONTROL, VISU and COM / SMALL, MEDIUM, LARGE equals. Started by trying CodeMGetContentByFirmcode (and productCode) expecting error 18 / Not Available if asking for a higher level of license compared to what I know is active, but function just returned the requested productcode and a featuremap Is this the way or is it better to use CodeMOpen? Which seems to also require a featureCode. Where can I find info on required featureCode? ProductCodes according to google: Control (PLC Runtime) Small (S) 16#00002FFF 12287 * Medium (M) 16#00003000 12288 Large (L) 16#00003001 12289 Visualization (WebVisu) Small (S) 16#00003002 12290 Medium (M) 16#00003010 12304 * Large (L) 16#00003003 12291 Communication (Com) * Small (S) 16#00003004 12292 Medium (M) 16#00003005 12293 Large (L) 16#00003006 12294 Thanks!
Last updated: 2026-10-06
Post by jroddball79 on PM556-TP-ETH — How to change IP address without overwriting the PLC program?
CODESYS Forge
talk
(Post)
Hi, I need to change the IP address of an ABB PM556-TP-ETH using ABB Automation Builder. The situation is: I have connectivity to the PLC using the current IP (configured in Communication Settings) Online Login works fine The Network Scan does not detect the PLC IP-Configuration tool shows all fields disabled I don't have the original project source, only an empty project The PLC has no SD card inserted The Online menu does not show an Upload option When I modify the IP in the project and connect, Automation Builder shows: "The PLC configuration needs to be updated. A full PLC download is required" I'm afraid a full download will overwrite the running program. Is there any way to change only the IP address without overwriting the application? I'm also open to solutions using third-party tools, Python scripts, or any other method (DCP protocol, direct TCP communication, etc.) as long as it doesn't overwrite the running application. Thank you
Last updated: 2026-05-19
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
Some new test. Now I cannot connect from Automation server to my gateway in any way also from my office setup with my unit directly connected to my router by dhcp. I can use the IDE and the tool "Connect Edge Gateway" and successfully connect to my server/link to my Automation server account. However no PLC will respond from Automation server "Network scan". I guess the traffic should be initiated by the gateway towards automation server? Any tips on how I can diagnose my problem? Ports to be opened etc? Thing is that this has been working previously but not now (base system has been updated from debian 12 to debian 13, but I dont know at which point it has stopped working). Setup as before. A "Codesys Control for Linux SL" running on a debian 13 installation. Any help/tips appreciated! Per Update. Found the error. Had a wrong gateway-setting. Which meant the PLC could not reach internet. Checked by "ping google.com" from the PLC.
Last updated: 2026-02-12
Post by yannickasselin on CloseTargetVisu
CODESYS Forge
talk
(Post)
To shutdown the TargetVisu: Add the VisuElemBase library to your project then call VisuElemBase.Visu_PRG.RemoveAllTargetVisuClients(); Exemple: PROGRAM PLC_PRG VAR xShutdownTargetVisu: BOOL; END_VAR ---------------------------------- IF xShutdownTargetVisu THEN xShutdownTargetVisu := FALSE; VisuElemBase.Visu_PRG.RemoveAllTargetVisuClients(); END_IF I tried calling RemoveAllTargetVisuClients() directly from a button mouse click event but it makes the Visu crash. So better using the code above and just set xShutdownTargetVisu to TRUE from the button. Works fine for me. To start the TargetVisu: From a cmd prompt. This will start the TargetVisu C:\Program Files\CODESYS\CODESYS Control RTE3>VisualClientController.exe --application=Application --flags=1 You can then place a .bat file on the desktop and put this inside: CD "C:\Program Files\CODESYS\CODESYS Control RTE3" VisualClientController.exe --application=Application --flags=1 exit Double clicking the .bat file will start the TargetVisu. You may need to replace the Application name by your own application name. Good to know: In the cmd above, if you replace --flags=1 by --flags=2, it will shutdown the TargetVisu.
Last updated: 2026-03-11
Post by eschwellinger on Editor FIND highlight color
CODESYS Forge
talk
(Post)
To change the color of search result markings (the "find color") in the CODESYS Text Editor using Themes, follow these steps: Go to the menu: Tools → Options. In the Options dialog, select the Text editor category. Switch to the Theme tab. Here, you can select your desired color theme for the text editor. The available color schemes (themes) are stored in the installation directory in the Themes folder. To specifically adjust the color for search result markings, go to the Text Area tab within the Text editor options. Here, you can customize the Selection color – Inactive parameter, which determines the color used to highlight search results. Changing the theme will apply a new set of color settings, including those for selections and search highlights. If you want further customization, you can manually edit or create your own theme files in the Themes folder of your installation directory Example "c:\Program Files\CODESYS 3.5.21.50\CODESYS\Themes\myDefault.editortheme" https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_options_text_editor.html
Last updated: 2026-03-12
Post by egr99 on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Hi there, Read the above description and experienced the same: Reading coil/discrete input/input register/holding register doesn't fill the mapped I/O variable. Any suggestions? Defined (see attachment): - Ethernet (with parameters according to the used Ethernet adapter of my Windows 11 laptop) - -Modbus TCP Client - - -LOGO231 as Modbus TCP Server - - -WS242 as Modbus TCP Server (WaveShare Modbus TCP <-> RTU converter) - - - -WS242_01 as Modbus Server, COM port (slave-id 1 RTU) - - - -WS242_03 idem (slave-id 3 RTU) - - - -WS242_11 idem (slave-id 11 RTU) Writing coil/holding register works from a mapped I/O variable works fine. Verification of Modbus traffic with WireShark: QUERY to and the RESPONSE of all slave-ids are correct Status of all defined is CONNECTED, RESPONSE_SUCCESS, RUNNING etc. Request counters increase with expected frequency. Error counter = 0. (To have all counters works fine I had to change Modbus TCP Client's parameter OptimizationON to FALSE). LOGO231 works fine: values in mapped I/O conform expectation WS242 without Modbus Server, COM port and with defined channels (for only 1 slave-id possible) works fine. PLC Settings: Update I/O while in stop: I see xBusy changing from FALSE to TRUE and vice versa. Always update variables: Enabled 1
Last updated: 2026-04-05
Post by imdatatas on CFC editor: enable inline value entry on unconnected input pins (as in Ladder Logic editor)
CODESYS Forge
talk
(Post)
In the CODESYS Ladder Logic editor, there's a really practical feature available while logged in (online) to the PLC: for an existing function block (e.g. TON or MC_MoveAbsolute), double-clicking on an unconnected input pin directly opens a value entry window right in the editor — with no need to assign any variable — and you can type a value directly. Likewise, if the input pin is of an ENUM or STRUCT type, it lets you pick a value of that type straight from a dropdown list. It also doesn't require assigning a variable or adding it to a watch list, etc. Unfortunately, in the CFC editor you can't write values directly to those unconnected input pins the way you can in Ladder — CFC only supports monitoring/display there. I wish this existing Ladder editor feature were also available in CFC — it would make the CFC editor far more usable. I think this would be a relatively small addition to the CFC editor, but it would make a real difference in daily commissioning and debugging work. It would be great to hear the development team's thoughts on whether this could be considered for a future release. Thanks in advance for reading!
Last updated: 2026-09-10
Post by abauza on Image Pool using in other libraries
CODESYS Forge
talk
(Post)
Hi im Albert, im developing libraries for my PLCs and i have some issues on visualization part. First of all I have done a library that have a image pool with a list of 4 gifs "ImagePoolErrors" (i've tested in other projects and it works) but the problem comes when i create another library that in the visualization part contains images from my image pool library, when i simulate a program that includes a instance of my second library object the visualization images dont show, any of them, i've checked all the references and tried some options of the image properties but without any difference. Here is the screenshots of the first library (that contains Image Pool) and the second library (that includes images of the image pool first library) and the visualization simulation (with the missing image gif issue). Any idea of what i forgotten in the process? If you need any detail of the library or of the project or you need the library file, ask me, thank on advance
Last updated: 2024-08-19
Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i´m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i´m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i´m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10
Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16
Post by micik on Using Codesys example problems
CODESYS Forge
talk
(Post)
Hello to all, I'm totally new to Codesys, but I do have some PLC programming experience, mosty with Siemens TIA and STEP7. I have just installed Codesys 3.5. sp19 and I have downloaded example with Ethernet Rockwell 1734AENT. The example can be found here: https://forge.codesys.com/prj/codesys-example/rockwell-1734-c/home/Home/ After opening, I had to manually update devices (Device, Ethernet, IP Scanner, EthernetIP adapter). However, when trying to build the project, I get the following errors: [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library System_VisuElemXYChart has not been added to the Library Manager, or no valid license could be found [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library system_visuinputs has not been added to the Library Manager, or no valid license could be found [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIP]: C0040: Function 'ProcessUpdateConfigurationQueue' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): IoDrvStartBusCycle [IoDrvEtherNetIP]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): Cyclic [GenericServiceUnConnected]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] cip object, 4.4.1.0 (3s - smart software solutions gmbh): ForwardOpenService [ConnectionManager]: C0040: Function 'GetAssemblies' requires exactly '3' inputs [ERROR] iodrvethernetipadapter, 4.4.0.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIPAdapter]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs Compile complete -- 7 errors, 13 warnings Build complete -- 7 errors, 13 warnings : no download possible! What could be the reason for this errors and how to rectify them? Thank you!
Last updated: 2024-02-01
Post by george32 on CSV file and string manipulation.
CODESYS Forge
talk
(Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27
Post by rcaponi on Codesys Control RTE V3. Remote Control
CODESYS Forge
talk
(Post)
Hello, I would like to have, if possible, some clarification on this function. That is, I would like to understand if it is useful for managing, fom my development PC, the RTE runtime executed on a remote control. This is what the help says: Remote PLC: Opens the Remote Configuration dialog. By enabling or disabling the Control remote PC, not local option, you determine whether a PLC is used that is on a remote or local PC. Accordingly, the menu commands Start PLC, Stop PLC, and PLC Configuration refer to the local PC or a PC reached on the network. For the remote PC, specify the Target PC address, Port number, and a Timeout value (in ms) for the connection (Remote Timeout [ms]). But does this mean that I also need to install the RTE runtime on my development PC? Is it possible to have some more information? Best regards Roberto Caponi
Last updated: 2023-09-22
Post by timvh on VisuElems.CurrentUserGroupId is not stable
CODESYS Forge
talk
(Post)
I'm not sure what you are trying to do, but getting the CurrentUserGroupID like this will not work, because there could be multiple Visualization Clients and each can have a different user that is logged in. Also when you go online with CODESYS and open an Visualization, this is counted as a client. Probably this is the reason you see it changing. What you can to is "iterate" over all clients and then see which user is logged in on which visualization Client. For this you need to add the Visu Utils library to the project and call the FbIterateClients. See https://content.helpme-codesys.com/en/libs/Visu%20Utils/4.4.0.0/VisuUtils/VisuActionUtilities/Function-Blocks/FbIterateClients.html fbClientIteration( xExecute := x_Execute, itfClientFilter := VU.Globals.AllClients, itfIterationCallback := fbIterator, xDone => x_Done, xBusy => x_Busy, xError => x_Error, eError => e_Error); The fbIterator, in the example above, should be an instance of an FB which you have created yourself and this must implement VU.IVisualizationClientIteration. For example: FUNCTION_BLOCK FB_ITERATOR IMPLEMENTS VU.IVisualizationClientIteration Then automatically the corresponding methods will be called. In the HandleClient Method, you will get an interface to the client(s) and then you can get the current user through this interface: itfClient.UserGroupId You can also get the UserName: itfClient.UserName
Last updated: 2023-11-14
Post by climblinne on Calling OPC UA Methods from UaExpert
CODESYS Forge
talk
(Post)
Hello, I hope someone could help me. I installed the newest Codesys 3.5 SP 20 Patch 1. When loading the demo files from @i-campbell I can upgrade them to the latest version and everthing works on the OPC-UA client side as expected (object "a" is visible, I can use the "ExampleMethod"). Now I * remove the "Information Model", * delete the "OPC_UA_Symbols Objects", * Add "Information Model" again * add "TestRootObjectType" again and "Generate IEC declarations" * and search for mapped instances (to get instance "a" again) Very good still working as expected. Now I delete the OPC_UA_Symbols and add it again referring to the "objecttest" from 16.9.2020. Also I redo the steps from above. The result is now, that I can't see the "a" object in the "Root/Objects" folder. Why ist this and how can I make it running? I think, it could may be a different version of the UA configuration file. I tried to build my own model definition files and got the same problem (but I am really not an expert). When someone has a actual model, which is also running in the actual Codesys I would be very grateful. Or even better, how to make the correct model in e.g. UA Modeler SW (I followed the description https://documentation.unified-automation.com/uamodeler/1.6.0/html/howprojnet_sec.html).
Last updated: 2024-07-01
Post by simone on Cannot connect to webvisu on localhost
CODESYS Forge
talk
(Post)
As I wrote before on the title, I have difficulties to connect to see webvisu from localhost. The story: while waiting for the plc+hmi to arrive, I'm preparing the software, mainly the visual parts trough the control Win3 x64 (same version as the ide 3.5.20.10). The problem is that I can't see the webvisu with the installed webbrowser. I don't know if this is a problem, but I changed the port to 9001 (randomly "free") because 80, 8000, 8080, 8088, 3000 are all occupied by other projects (all on the Apache server). Is there something wrong with the config file? This is the url: localhost:9001/webvisu_app.htm and here the config file part "CmpWebServer". [CmpWebServer] ;The handling of startup/shutdown of the webserver: ;0->automatically start, shutdown only on shutdown of the runtime;1->automatically start, could be shutdown on demand ;2(default)->start/shutdown on demand;3->start on demand, shutdown only on shutdown of the runtime StartupType=0 ;The TCP port the webserver listens on WebServerPortNr=9001 LocalAddress=localhost ;LocalAdapterName=LAN-Connection LocalAdapterName=EthernetPCPLC ;LocalAdapterNameUnicode=L\00A\00N\00-\00C\00o\00n\00n\00e\00c\00t\00i\00o\00n\00 LocalAdapterNameUnicode=E\00t\00h\00e\00r\00n\00e\00t\00P\00C\00P\00L\00C\00 Thanks for all the help!
Last updated: 2024-07-11
Post by timvh on How to implement an interface (IElement)?
CODESYS Forge
talk
(Post)
See: https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ This contains an application "OnlineChangeSafeLinkedListExample". What you should do is create a new interface which has your "Priority" property. Then your FB should extend the base element function block and implement your own interface: E.g. FUNCTION_BLOCK MyElement EXTENDS COL.LinkedListElementBase IMPLEMENTS I_MyInterface Then the __QUERYINTERFACE does the magic to check if your "element" also implements your interface. Something like this: // Compares this element with itfElement. // Returns 0 if the elements are equal, < 0 if the element is less than itfElement, // > 0 if the element is greater than itfElement. // This method will be called from sorted collections (e.g. |COL.SortedList|) to sort the elements. // IMPORTANT: The underlying value to be compared with MUST NOT be changed during the lifecycle of the object. METHOD ElementCompareTo : INT VAR_INPUT (* The element to compare*) itfElement : COL.IElement; END_VAR VAR itfIntElement : I_MyInterface; xResult : BOOL; END_VAR // We use integer iInt1 for sorting. xResult := __QUERYINTERFACE(itfElement, itfIntElement); IF xResult THEN IF iInt1 < itfIntElement.Priority THEN ElementCompareTo := -1; ELSIF iInt1 > itfIntElement.Priority THEN ElementCompareTo := 1; ELSE ElementCompareTo := 0; END_IF ELSE ElementCompareTo := -1; END_IF
Last updated: 2024-07-22