CIFX 50E-DP on Linux.
CODESYS Forge
talk
(Thread)
CIFX 50E-DP on Linux.
Last updated: 2025-05-23
Warning code C0373
CODESYS Forge
talk
(Thread)
Warning code C0373
Last updated: 2025-05-23
Post by mondinmr on CIFX 50E-DP on Linux.
CODESYS Forge
talk
(Post)
We need to use two CIFX 50E-DP cards in two Linux PCs running CODESYS for Linux SL (the machines are x86). Has anyone experienced any issues? Do these cards work reliably under Linux?
Last updated: 2025-05-23
Post by bjohnson on Failed to instantiate the frame window error
CODESYS Forge
talk
(Post)
IT updated a group policy that caused this issue. We resolved by going to Local Group Policy Editor > Local Computer Policy > Computer Configuration > Windows Settings> Security Settings > Local Policies > Security Options. Set "System Cryptography: Use FIPS compliant algorithms for encryption, hashing, and signing" to DISABLED
Last updated: 2025-05-23
Post by bjohnson on CODESYS and Win10 - "the version profile is not valid" error
CODESYS Forge
talk
(Post)
We just had this problem today when our IT updated a group policy. You need to go to Local Group Policy Editor > Local Computer Policy > Computer Configuration > Windows Settings> Security Settings > Local Policies > Security Options. Set "System Cryptography: Use FIPS compliant algorithms for encryption, hashing, and signing" to DISABLED
Last updated: 2025-05-23
CODESYS and Win10 - "the version profile is not valid" error
CODESYS Forge
talk
(Thread)
CODESYS and Win10 - "the version profile is not valid" error
Last updated: 2025-05-23
Failed to instantiate the frame window error
CODESYS Forge
talk
(Thread)
Failed to instantiate the frame window error
Last updated: 2025-05-23
Post by bjohnson on CODESYS and Win10 - "the version profile is not valid" error
CODESYS Forge
talk
(Post)
We just had this problem today when our IT updated a group policy. You need to to got Local Group Policy Editor > Local Computer Policy > Computer Configuration > Windows Settings> Security Settings > Local Policies > Security Options. Set "System Cryptography: Use FIPS compliant algorithms for encryption, hashing, and signing" to DISABLED
Last updated: 2025-05-23
Post by bmatlove on Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Post)
Using Codesys 3.5.18.30 I am trying to work with an array of variable length in one dimension, but known in the other dimension. For example, using an array that represents a list of items, each with an attribute profile. I do not know how many items will be in the list, but I know that every item has 5 attributes, like size, weight, etc. Codesys does not seem to be able to accept this. I have referenced Data Type: ARRAY OF documentation page, which is not explicit if variable & fixed length array dimensions can be mixed. In the VAR_IN_OUT scope, I initially tried MY_ARRAY : ARRAY [*, *] OF REAL; which was no problem, of course. I then modified it to MY_ARRAY : ARRAY [*, 1..5] OF REAL; which throws C0006: ', or ]' expected instead of '..' among consequent downstream errors. I then used the Auto Declare -> Array Wizard, which accepted (asterisk)-(asterisk) and 1-5 for 2-dimensional lower and upper bounds. It output: MY_ARRAY: ARRAY[*..*, 1..6] OF INT; which throws the same error stream. What's the deal here? Is this possible?
Last updated: 2025-05-23
Post by andrax on Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Post)
Arrays with variable lengths are a bad idea. This makes your system unstable and can lead to crashes. Declare your array large enough to reserve enough memory
Last updated: 2025-05-24
Io-link library vor ethernet/ip
CODESYS Forge
talk
(Thread)
Io-link library vor ethernet/ip
Last updated: 2025-05-24
Post by r19h72 on Io-link library vor ethernet/ip
CODESYS Forge
talk
(Post)
gibt es Pläne für eine Erweiterung der io Link sl library auf ethernet/ip? derzeit sind nur profinet und ethercat verfügbar wann kann man damit rechnen?
Last updated: 2025-05-24
Post by nz-dave on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
i had a similar problem trying to send files to C: on local computer. Ended up using Oscat ftp to transfer file with filezilla. i read there is an "write protection", possibly to do with windows, issue with sp19 and up. there are some config files in the codesys dir you can change, which may help. after i was able to transfer to local PC\downloads but not c: so went the ftp route. works well. https://forge.codesys.com/forge/talk/Runtime/thread/5cac1390b4/
Last updated: 2025-05-26
Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Thread)
Variable Length Array - Cannot mix variable and fixed length dimensions?
Last updated: 2025-05-26
Post by nz-dave on Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Post)
VAR CONSTANT size : INT := 10; END_VAR My_Array : ARRAY[1..SIZE , 1..5] OF REAL;
Last updated: 2025-05-26
Post by qkkk on Device Scan
CODESYS Forge
talk
(Post)
Hello all, I have developed a custom I/O driver in CODESYS that communicates via a Unix Domain Socket. In my DeviceDescription.xml, I have set up the following: <scan supported="true"> <scanfbinstance fbname="IOScanDevice"> The goal is to allow the user to scan for connected I/O modules from the CODESYS GUI ("Scan for Devices") and automatically populate the device tree with detected submodules.</scanfbinstance></scan> The function block IOScanDevice is implemented in the driver library and added to the main device's FB instances. However, when I initiate the scan from the GUI, nothing appears to happen the function is not executed. Is there an example project or driver (open source or from CODESYS Forge) that demonstrates a working custom scan implementation?
Last updated: 2025-05-26
Post by lbouchard on CANOpen SIL2 error: UNSAFESTACK_NOT_OPERATIONAL
CODESYS Forge
talk
(Post)
Update: I still have no idea what was causing my issues, but it went away as soon as I identified that another device on the CAN was generating a Sync message at 16#7F. Changing this to be on 16#80 made the problem go away. I have no idea why this solves the problem and would love to hear from anyone who knows why these two things might be related.
Last updated: 2025-05-26
CANOpen SIL2 error: UNSAFESTACK_NOT_OPERATIONAL
CODESYS Forge
talk
(Thread)
CANOpen SIL2 error: UNSAFESTACK_NOT_OPERATIONAL
Last updated: 2025-05-26
Device Scan
CODESYS Forge
talk
(Thread)
Device Scan
Last updated: 2025-05-26
Post by canplum on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
Hello Dave_t, thank you for your reply but the modifications of the config files are already done. Unfortunatealy with no success until now. Cheers, canplum
Last updated: 2025-05-26
Post by nz-dave on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
So did you get it working?
Last updated: 2025-05-27
Post by shaunvdm on Canbus Slave SDO Read from Object
CODESYS Forge
talk
(Post)
Busy testing a solution to use Canbus Slave to replace a physical device and convert to Ethercat device but keep the Canbus Master in place. Master needs to Read SDO object 5FA2. In the Master PLC if i send the SDO with 8 bytes in message IE: 60B 40 A2 5F 00 00 00 00 00 i get my expected 58B 43 A2 5F 00 00 68 36 02 containing data back. Problem is if we issue a 4 byte command can send 60B 40 A2 5F. Surely the canbus slave should respond with a 58B 43 A2 5F 00 00 68 36 02 but it comes back as 80 A2 5F 00 00 00 00 08 - meaning this OBJECT does not exist. Is there a setting in the canbus slave driver for Canbus to allow the 4 byte command to read the SDO OBJECTS ?
Last updated: 2025-05-27
Canbus Slave SDO Read from Object
CODESYS Forge
talk
(Thread)
Canbus Slave SDO Read from Object
Last updated: 2025-05-27
Post by canplum on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
No unfortunately not until now.
Last updated: 2025-05-27
How to create custom visualisation components (widgets)?
CODESYS Forge
talk
(Thread)
How to create custom visualisation components (widgets)?
Last updated: 2025-05-27
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.