Post by damian177 on Codesys and SMS in RPi CODESYS Forge talk (Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?
Last updated: 2023-09-29

Post by markusef3 on Verhalten bei zu kurz gesetzter Task-Zyklus-Zeit CODESYS Forge talk (Post)
Hallo zusammen, ich habe eine Frage bezüglich dem Verhalten der Tasks. In der Hilfe und hier im Forum sowei im Internet konnte ich diesbezüglich leider nichts finden. Wie genau verhält sich Codesys wenn mehrere zyklische Task eingestellt sind und bei einem ab und zu die Abarbeitung des angehängten Programmes länger dauert als das Aufrufintervall eingestellt ist. D.H. der nächste Aufruf würde "theoretisch" erfolgen bevor alles im Program abgearbeitet ist. Z.B. Intervall ist 1ms, Abarbeitung dauert manchmel 1,1ms oder länger. (Watchdog ist zwar eingeschaltet, aber größer gewählt als das Zyklische Intervall zum Aufruf. Watchdog soll jetzt auch nicht das Thema sein). Was passiert in so einem Fall? - Wird das Programm zuerst zu Ende abgearbeitet und dann der nächste Aufruf gestartet? - Wird das Programm "mittendrin" unterbrochen und dann neu gestartet? - wie genau muss ich mir das vorstellen wenn dem so ist? - ...... - ...... Ich konnte überall nur Anleitungen finden wie die Tasks zu konfigurieren sind, jedoch nichts dazu was im oben genannten Fall genau passieren wird. Gruss Markus
Last updated: 2023-10-19

Post by toffeebonbon on EL7041-0052 - does it run with EL7041 SoftMotion? CODESYS Forge talk (Post)
Good morning everyone. In my setup I am trying to use a couple of EL7041-0052 (the EL7041 variant without terminals for an encoder) to run stepper motors without feedback. When using the softmotion drivers for the EL7041 (Rev22 and Rev24, even selecting external feedback type doesn't work) the device log shows warnings for the corresponding hardware: "SDO write error 0x1 -> 0x8012:0x08 eError 0x1 AbortCode 0x6090011". 0x8012:0x08 is the register for the Feedback Type. My best guess was setting the the register value in the start parameters to zero, but the result is the same. What else can I try to get the hardware to work? I have screenshots attatched showing the running fieldbus and the log messages. EDIT: One clarification: the "device log" that shows the error is the PLC, not the ethercat terminal. The log of the terminal itself shows neither errors nor warnings. BR Robert
Last updated: 2023-11-29

Post by marek71 on Ambiguous use of name - CO136 CODESYS Forge talk (Post)
My PLC is WAGO PFC200 Firmware Revision 26. target After updating WAGO_Devices_and_Libraries with newer Firmware 27, CODESYS wants to update all libraries to new versions. I will only add that I did not update the Firmware in the PLC. After compiling the program, I received the following errors: ------ Build started: Application: Device.Application ------- Typify code... [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_RESULT' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0032: Cannot convert type 'Unknown type: 'RTS_INVALID_HANDLE'' to type 'POINTER TO BYTE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0136: Ambiguous use of name 'RTS_INVALID_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0046: Identifier 'RTS_INVALID_HANDLE' not defined [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_tx_empty: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_get_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_line_available: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): COMSW_SET_MODE: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_set_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' Compile complete -- 10 errors, 0 warnings Build complete -- 10 errors, 0 warnings : No download possible The problem was caused by the WagoSysPlainMem(WAGO) library in the original version 1.5.3.0 after updating to 1.5.3.1. After returning to version 1.5.3.0, the problems disappeared. Probably the version number of this library is responsible for supporting the appropriate Firmware Revision. Can anyone confirm or deny my suspicions?
Last updated: 2024-07-06

Post by trusty-squire on Confused by dwIpoTime input for SMC_Interpolator CODESYS Forge talk (Post)
Hi, Learning Codesys CNC, and I am confused by the dwIpoTime parameter. I have a basic demo application, using SMC_Interpolator feeding into SMC_TRAFO_Gantry2Tool2, which then sets the position of the x/y SM_Drive_Virtual axis. I also have a C axis which revolves the tool, which is controlled using a simple tangential angle calculation SMC_CalcDirectionFromVector. The GCode I'm using has feed/accel set at 500. The axis configuration limits are well above that (2000). What's strange is that, when I run the simulation, the feed speed changes drastically when I update the variable dwIpoTime. The larger the number, the faster it moves. What's going on here? The documentation only says "This variable has to be set for each call. It represents the cycle time in μsec." Why does it change the feed speed I'm seeing the in simulation? What is a good number to use? The example I was looking at set it at 5000. Screenshot attached.
Last updated: 2024-07-18

Post by c3po on Von SNMP auf IIoT wechseln CODESYS Forge talk (Post)
Hallo, 1. ich bin komplett NEU was Codesys angeht 2. ich muss direkt ein Retrofit machen von V2 auf V3 3. Neue Steuerung: WAGO 750-8211 PFC200. 4. das Projekt in V2 hat über SNMP daten im Netzwerk zur Verfügung gestellt, oder diese gelesen 5. das Projekt in V3 kann SNMP nur noch eingeschränkt nutzen, deswegen wurde mir vom WAGO Support nahegelegt die IIoT Lib zu verwenden. Frage: Wie mach ich das? Konkret: Ich habe die WagoAppSNMP Bibliothek installiert, damit kann ich schon mal Set und Get nutzen (hoffentlich, hab es ja noch nicht getestet, sondern nur programmiert). Ist das ein schlauer Weg, das über diese Lib zu machen? Denn: was macht der SNMP_SET_PLCDATA_WRITEAREA ? Den kann ich über die Wago Lib nicht nutzen und weiß auch nicht, was dieser Baustein konkret tut (Bild im Anhang). Es scheint mir, hier werden Daten auf ein Word im Netzwerk geschrieben? Aber geht das nicht auch einfacher? Es ist ja keine Adresse hinterlegt, wo das hin gehen soll oder? Also, ich verstehe den Baustein nicht so ganz und konnte bisher auch keine Erklärung dazu finden. Vielen Dank schon mal für eure Unterstützung, K.
Last updated: 2024-08-19

Post by julianramirez on ModbusFB write update CODESYS Forge talk (Post)
Hello everyone, I am testing the ModbusFB library tcp server and so far I am able to create holding registers successfully, however, I am trying to identify after each write which registers got updated (i.e. function code, write value). I can even see the var udiNumWriteRequests, which increases with every write. I noticed that there is logging with the LogStatusInfo method. After I call it I am able to read in the console stuff that I want. Nevertheless, this is only available at the logs and is not easy to decode because it consists on several messages, I would like to know if there is a way for me to retrieve this information from the function itself with pointers or if there is any way to copy the logs messages (assuming that I can filter them with the LoggingOptions to only show what I need) inside the runtime code and not in the console. Thanks for your help :)
Last updated: 2024-09-16

Post by shubadubalu on OP UA Client - Variablen zeigen alle 0 CODESYS Forge talk (Post)
Hallo liebe Codesys Community :) Momentan versuche ich eine OPC-UA Verbindung aufzubauen, dabei habe ich ein komisches Verhalten festgestellt. Man sucht sich ja die Variablen indem man auf "Variablen aktualisieren" in Datasource klickt. Diese werden dann auch in der enstprechenden Variablenliste automatisch deklariert. Wird das Programm übertragen und die CPU (PFC200) gestartet, aktualisieren sich die Werte entsprechend. Mittels UA Expert passen die Werte aller Variablen. Starte ich jetzt die CPU neu (OPCUA Client), werden alle Variablen mit dem Wert 0 angezeigt. Unter "Allgemein und Diagnose" wird verbunden angezeigt. Auch UA Expert zeigt weiterhin die aktuellen Server Werte. Klicke ich erneut auf "Variablen aktualisieren" und übertrage das Programm funktioniert wieder alles. Ein Kalt / Warmstart hat leider keine Auswirkung. Auch den Server Neustarten bringt kein Erfolg. Wie schaffe ich es, dass die Variablen nach CPU Neustart auch die Werte des Servers annehmen? Ich freue mich über Tipps und Ideen. :) Weitere Informationen: CODESYS 64 3.5.20.50 CPU: WAGO PFC 200 750-8216 OPC UA Kommunikation Anonym und ohne Security-Strategie
Last updated: 2025-02-18

Post by pernockham on Persistence Manager: Config File not found? CODESYS Forge talk (Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20

Post by nz-dave on MC_HOMING CODESYS Forge talk (Post)
Hi Just new to motion and i am building my own 3axis cnc cutter using servo drives. i have every thing working quite well apart from mc_home. when executed (r_trig) it stops immediately and i get fb_wasnt_called_during_motion. if i execute the mc_home fb with a toggle it just runs and runs for a while then errors out. what im unsure of is the way mc_home works. from what i understand it changes the drive mode to 6 (homing) and should then run of the drive homing settings. once origin sensor is made then homing would stop and mc_home.done is true. and the position on the fb is where i what the new home position (zero) to be? or do i feed mc_readposition to that input? so i would think its the settings in the drive that aren't quite right. but i believe they are all correct. has any one got any info to steer me in the right direction? Cheers
Last updated: 2025-04-04

Post by jeroenaero on Problem with CodeSys Control SL Deploy Tool 4.15.0.0 CODESYS Forge talk (Post)
Hello, We just installed the new version of CodeSys Control SL Deploy Tool 4.15.0.0 but we get the following error when we try to add a VPLC. Can someone of the CodeSys team fix this issue? the object reference is not set to an instance of the object Zie het einde van dit bericht voor meer informatie over het aanroepen van JIT-foutopsporing (Just In Time) in plaats van dit dialoogvenster. ** Tekst van uitzondering ** System.NullReferenceException: De objectverwijzing is niet op een exemplaar van een object ingesteld. bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm.ShowAllImages() bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm..ctor(List1 virtualControls, List1 existingNames) bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.OnAddInstanceClick() bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.bt_add_Click(Object sender, EventArgs e) bij System.Windows.Forms.ToolStripItem.RaiseEvent(Object key, EventArgs e) bij System.Windows.Forms.ToolStripButton.OnClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleMouseUp(MouseEventArgs e) bij System.Windows.Forms.ToolStripItem.FireEventInteractive(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStripItem.FireEvent(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStrip.OnMouseUp(MouseEventArgs mea) bij System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) bij System.Windows.Forms.Control.WndProc(Message& m) bij System.Windows.Forms.ScrollableControl.WndProc(Message& m) bij System.Windows.Forms.ToolStrip.WndProc(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) bij System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Geladen assembly's ** mscorlib Assembly-versie: 4.0.0.0 Win32-versie: 4.8.9300.0 built by: NET481REL1LAST_C
Last updated: 2025-04-24

Post by kuegerls on Programmatically clearing or syncing Data Source Manager cache? CODESYS Forge talk (Post)
Hi everyone, is there a way to programmatically clear the cache of the Data Source Manager in CODESYS so that variable values are re-synchronized from the OPC UA server (Symbol Configuration with OPCUA features)? Alternatively, is it possible to trigger a manual synchronization of data source variables from within the application code at runtime? Here’s the situation: A variable is first written by the OPC UA client to the server in one state of a state machine and changes to another state – so the initial communication works. Later, the server changes the variable value, but the client does not receive or reflect the updated value, unless the variable is actively written again. I’m looking for a way to force the client (data source manager) to re-read or refresh the variable state from the server, possibly by clearing the internal cache or triggering a sync. Any ideas or suggestions would be greatly appreciated! Thanks!
Last updated: 2025-05-23

Post by westcountryewe on Displaying a Target Web Page on WebVisu CODESYS Forge talk (Post)
I have a main PLC with my CODESYS project on, including Web Visu. I also have a second device used for pump monitoring, all of this is displayed on a seperate HMI. I am looking at displaying the pump monitoring HMI on WebVisu so that I can solely use 1 HMI rather than having two. I can project the pump monitoring HMI into Chrome, and log in and it works fine. When I'm using the Web Browser element in Web Visu, enter my URL (device IP) it shows me the web page, but doesn't show me all of it. It uses parts of JavaScript for the login authenticiation and various other widgets. Similarly, I cannot get Youtube or Google to display on WebVisu either (possibily because of the same reason). Does anybody have any tips on how I can display the likes of Youtube or Google onto WebVisu so I can view it on my 7inch HMI (I suspect that if I can get Youtube or Google to work, then I will also be able to get my pump montitoring web page to work too).
Last updated: 2025-07-09

Post by gvdb on Raspberry Pi 4 mod B icm codesys linking USB serial device (arduino) to com port CODESYS Forge talk (Post)
Raspberry Pi 4 Codesys 3.5.20 sp3 Codesyscontrol 4.15.0.0 based on sdk 3.5.21.0 Hi all, I have found a lot of topics but none of them get me on the right path, therfore i started a new post. Usually i work with plc based systems and codesys but now im trying to create an project where i read out a serial data stream from an arduino connected by an USB port. in the future this need to be more arduino's but first trying to make it work with one I had my program working but i needed to update my raspberry pu to the letest version to get the mimo screen working. Now i tried several rules in the CODESYSControl.cfg and/or CODESYSControl_User.cfg files but i never get the com port opened. At this moment i have an file CODESYSControl_User.cfg with entry: [SysCom] Linux.Devicefile.1=/dev/ttyUSB0 I tested the connection with minicom and the data runs fluently. Can somebody help me with what could be wrong? the com port states ERROR_UNKNOWN 5004 when i tried to open.
Last updated: 2025-07-17

Post by christoph--b on Probleme mit Speicheraufteilung nach Wechsel von Wago 750-841 zu 750-891 CODESYS Forge talk (Post)
Hallo, ich habe in meiner Hausautomation eine Wago 750-841 mit einem doch mittlerweile umfangreichen Programm. Diese wollte ich nun gegen eine 750-891 der 4. Generation austauschen. Aufgrund der Programmgröße hatte ich damals die Speichergröße für Retainvariablen von 16#4000 auf 16#7000 vergrößert und so läuft sie nun seit Jahren fehlerfrei. Allerdings mit der 750-891 bekomme ich offensichtlich eine Überschneidung mit dem Modbusregister, denn die Werte über Modbus spielen verrückt. In der Standardgröße mit 16#4000 tritt das Phänomen nicht auf, reicht dann aber nicht für das vorhandene Programm. Dafür gibt es sicher eine Lösung, denn die 891 hat ja deutlich mehr Speicher. Allerdings kenne ich mich mit der Speicheraufteilung nicht aus, wo man da was optimieren kann, damit ich den Speicherbereich entsprechend erweitern kann, aber es zu keiner Überschneidung kommt. Für Hilfe wäre ich sehr dankbar
Last updated: 2025-07-20

Post by kurtk on Modbus TCP Server CODESYS Forge talk (Post)
ditto I'm just getting my codesys wheels on and the modbus stuff is confusing. I am re-platforming an existing PLC application On that platform one could simply tag variables to register numbers and the whole shooting match could be accessed via modbus and typically holding registers and input registers were treated the same way... On codesys I see there is a modbus TCP server Device I/O mapping tab and a Modbus TCP server IEC objects tab I get the sense that one can configure the serving of variables both/either way but am unclear about the optimum/necessary path. Apparently in the IEC Objects tab one can "ADD" something or other - presumeably channels. I have created a preliminary function block but the Select Function Block window shows nothing to select WTH ? I exported the Device mapping and was surprised to see the entire Device IO map - complete with all the bit-mapped holding/input registers!! WTH!!?? Bit-mapped words are strictly a nichey special purpose application. I am targetting making a couple hundred variables available which would turn into hundreds of pages of IO/mapping Is the FUnction Block IEC objects thingy an alternative to that ? I notice that CODESYS shows the tags which the PLC used to specify the register address... are tags used in CODESYS for any specific hard-core purpose ?
Last updated: 2025-08-19

Post by antonz on CoDeSys v3.5: creating libraries for both 32-bit and 64-bit controllers CODESYS Forge talk (Post)
Looking for thoughts on creating libraries that can be used on both 32-bit and 64-bit controllers. We are currently writing software in CoDeSys for both target types and will continu to do so for the near future. Projects are always unique, no straight forward copy/paste, yet there is enough similarity between them to use libraries for recurring logic. I do not want to create and maintain twice for both platforms if this is not absolutely necessary. I am aware of useful datatypes like __XWORD, __XINT, __UXINT. Still looking for more information and/or sample code for portable pointer arithmetic. In addition to that: how should one go about when creating and working with compiled libraries? Would I need to compile the same lib twice, once for 32-bit targets once for 64-bit targets? I would end up with two different libs with the same namespace, which does not sound elegant to me. Note: I did not intentionally make the previous paragraph bold. The forge forum software seems to do this automatically upon insertion of a word which starts with two underscores, e.g. __XWORD (yeah, here we go again :) )
Last updated: 2025-08-25

Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC CODESYS Forge talk (Post)
Hello Everyone, I'm working on a CODESYS Standard Project using CODESYS Control Win V3 x64 with Structured Text. The goal is to integrate a Phoenix Contact device coupler (Part ID: BK PN TPS 2403869) via PROFINET. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by alexgooi on Licensing info not available. CODESYS Forge talk (Post)
Sorry for the question, but I'm not completely getting the idea here, could you be more specific, maybe give an example? I'm now in a state where I don't have a softcontainer on my license server anymore (even after reinstalling from the Codesys-IDE). I tried reaching the webserver of Codemeter but when I do that I get redirected to http://"IP":22352 This is not reachable, afterwards I installed lynx on my Debian machine (command line only). From here I could reach the webserver and toggle the network server setting, but unfortunately this did not help. I also tried to changed the remote read setting to 1 (in the Server.ini file). But after a Codemeter reboot this is overwritten to 0. I have the feeling that it should be much easier to get a license to work, am I missing some checkbox somewhere? Is there a tutorial (or manual) that explains the licensing sequence step by step, because I'm pretty stuck.
Last updated: 2025-10-01

Post by e13740e on Parameterized Property syntax for array element processing CODESYS Forge talk (Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT <index_name> : <index_type>; // One or more index parameters are declared here END_VAR</index_type></index_name></data_type></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY
Last updated: 2025-10-09

Post by e13740e on Parameterized Property syntax for array element processing CODESYS Forge talk (Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT // One or more index parameters are declared here <index_name> : <index_type>; END_VAR</index_type></index_name></data_type></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY
Last updated: 2025-10-09

Post by marsmaennchen on MQTT,mehrere Topics publish/subscribe CODESYS Forge talk (Post)
Hallo zusammen, ich habe im Grunde dieselbe Frage wie in diesem Thread: https://forge.codesys.com/forge/talk/Deutsch/thread/85372a6daf/ Leider hat der Threadersteller das Problem selbst gelöst, ohne seine Lösung zu teilen. Mein Setup: Ich möchte von einer WAGO PFC200 Daten per MQTT an HomeAssistant übertragen. Die Grundkommunikation steht bereits. Angenommen, man hat 50 Lichtschalter und 50 Lampen. Wie ist das übliche Vorgehen, um 50 einzelne Bool-Werte (Lichtschalter ein/aus) effizient zu übertragen? Ich finde einfach kein Beispiel, das ich als Vorlage nutzen könnte. Muss wirklich für jeden Lichtschalter ein eigenes MQTT-Topic und somit ein eigener Baustein in CODESYS angelegt werden? Also z. B. Topic/LS1/state, Topic/LS2/state usw.? Oder gibt es eine gängige, professionellere Methode, mehrere Schalter effizient zu übertragen? Zur Eingrenzung: Ich nutze die CODESYS IIoT Libraries, da die Janz Tec MQTT Library für mich bisher zu komplex ist. Kann mir jemand bitte erklären, wie Profis so etwas lösen? Vielen Dank schon mal für eure Tipps! Gruß Patrick
Last updated: 2025-10-10

Post by wbj0t on System libs and I/O Drivers CODESYS Forge talk (Post)
Hi everyone. My question about: where I can learn (read or watch) an info about codesys workflow through the system IO libs? I want to know how to implement I/O drivers by my self. In the system libs I see many interfaces, methods etc... But there is no explanation about them, just names of methods and fields of the FBs. I know about this page: https://forge.codesys.com/drv/io-drivers/doc/Generic/ There is so BIG the device description file and not so clear explaining of the attributes and elements, also some elements or attributes missed at it all. Yes, there are code examples on this page, but, so shortly and, for example, code about Modbus drivers is absent. And even if I try to add the IoDrvFB with lib, I get and error, something like: "failed to load IoDrvFB driver". And what about the book of codesys that written by Gary Pratt? Is there information about system libs and drivers in this book more clearly? Thank you :)
Last updated: 2024-02-02

Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27

Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27