Search talk: Object reference not set to an instance of an object

 
<< < 1 2 3 4 5 .. 234 > >> (Page 3 of 234)

How to sort JSON object in codesys CODESYS Forge talk (Thread)
How to sort JSON object in codesys
Last updated: 2024-05-08

Doc-Export without RST of Get an Set acessors CODESYS Forge talk (Thread)
Doc-Export without RST of Get an Set acessors
Last updated: 2015-06-30

Create dynamically visual object CODESYS Forge talk (Thread)
Create dynamically visual object
Last updated: 2010-06-15

Get active object/ device editor CODESYS Forge talk (Thread)
Get active object/ device editor
Last updated: 2019-02-06

Rotating object in design time CODESYS Forge talk (Thread)
Rotating object in design time
Last updated: 2022-03-14

Object Index Minimum for PDOs CODESYS Forge talk (Thread)
Object Index Minimum for PDOs
Last updated: 2017-02-24

Object oriented V3: what hardware ? CODESYS Forge talk (Thread)
Object oriented V3: what hardware ?
Last updated: 2012-03-23

Distinguish object types in project tree CODESYS Forge talk (Thread)
Distinguish object types in project tree
Last updated: 2019-04-11

Object oriented Web-Visu CODESYS Forge talk (Thread)
Object oriented Web-Visu
Last updated: 2019-08-23

Visudialog.keypad and webbrowser Object visualization !! CODESYS Forge talk (Thread)
Visudialog.keypad and webbrowser Object visualization !!
Last updated: 2022-03-29

Codesys 3.5.18 No visualization object CODESYS Forge talk (Thread)
Codesys 3.5.18 No visualization object
Last updated: 2022-05-02

exported object annotation documentation CODESYS Forge talk (Thread)
exported object annotation documentation
Last updated: 2012-09-13

ScriptObject' object has no attribute 'create_pou' CODESYS Forge talk (Thread)
ScriptObject' object has no attribute 'create_pou'
Last updated: 2018-11-07

Declare enumerations outside Object Organizer? CODESYS Forge talk (Thread)
Declare enumerations outside Object Organizer?
Last updated: 2020-09-13

No source code available (cip object) CODESYS Forge talk (Thread)
No source code available (cip object)
Last updated: 2024-07-16

How to reference an element on a visiualization in program? CODESYS Forge talk (Thread)
How to reference an element on a visiualization in program?
Last updated: 2012-10-22

CmpIecVarAccess to get name of a type, not of a variable (instance) CODESYS Forge talk (Thread)
CmpIecVarAccess to get name of a type, not of a variable (instance)
Last updated: 2016-06-08

Post by fless on Release SP20 - Changes in behaviour? CODESYS Forge talk (Post)
use this to set an invalid reference Add_EVT_OUT REF= 0;
Last updated: 2024-03-24

Post by manuknecht on Using SMC_MOVTYP.INITPOS without specifying the start position CODESYS Forge talk (Post)
I am using the object SMC_GEOINFO to generate a trajectory and move a system accordingly using the SMC_INTERPOLATOR function block similar to the sample project CNC10_DynamicPath.project. According to the documentation, the movement type INITPOS does not require a start position in the SMC_GEOINFO object, which is confirmed in the documentation of the SMC_GEOINFO object. When using the movement type INITPOS however, the motion will still start from the starting point defined in the SMC_GEOINFO object (0,0,0 if not specified otherwise). Does someone know how to resolve this or is there an example project that makes use of the INITPOS movement type without specifying the starting point? Thanks in advance!
Last updated: 2023-12-15

Post by struccc on Release SP20 - Changes in behaviour? CODESYS Forge talk (Post)
Dear all, I've just started to migrate some of my ancient projects to SP20. There is one strange error (?) I have noticed so far. In a method call, depending on the circumstances I would like to return reference to an object, or an invalid reference: METHOD Add_EVT_OUT : REFERENCE TO FB_MSG VAR END_VAR IF __ISVALIDREF(refMSG_Entry) THEN Add_EVT_OUT REF= MANAGER.AddMsg_EVT_OUT( refMSG_Entry, _Get_EVT_Message(MSG_EVENT.OUT), _Get_EVT_AddCode(MSG_EVENT.OUT) )^; ELSE Add_EVT_OUT := 0; END_IF So far setting a reference variable to 0, did this. But now, the expression Add_EVT_OUT := 0; gives an error: [ERROR] DB_WTP_370: Add_EVT_ACK MSG_TRIGGER_EXT: C0032: Cannot convert type 'BIT' to type 'REFERENCE TO FB_MSG' Naturally... I can write: Add_EVT_OUT := DWORD#0; But is this the correct way? Is there any constant I could use instead, like "NULL"? Or this is totally wrong and to be avoided?
Last updated: 2024-03-24

ENI server: Object type registry not found in the database CODESYS Forge talk (Thread)
ENI server: Object type registry not found in the database
Last updated: 2010-02-19

How to Calculate Checksum of an array of bytes? CODESYS Forge talk (Thread)
How to Calculate Checksum of an array of bytes?
Last updated: 2016-05-08

Post by timvh on Sensor not set CODESYS Forge talk (Post)
Your function block instance is not called, so the code is not executed to set the light on when the button is pressed.
Last updated: 2024-05-27

[OOP] Use extended interface instead of base interface as a method return object CODESYS Forge talk (Thread)
[OOP] Use extended interface instead of base interface as a method return object
Last updated: 2017-03-02

Set REFERENCE to 0 (null) when no longer used CODESYS Forge talk (Thread)
Set REFERENCE to 0 (null) when no longer used
Last updated: 2024-10-07

<< < 1 2 3 4 5 .. 234 > >> (Page 3 of 234)

Showing results of 5838

Sort by relevance or date