Redundancy problem - primary PLC suddenly goes to simulation state CODESYS Forge talk (Thread)
Redundancy problem - primary PLC suddenly goes to simulation state
Last updated: 2025-06-19

Post by alsiddhartha on TextList name error (fake) CODESYS Forge talk (Post)
Hello, I’m developing a program and for some reason I got this error: C0193: Name '2,Recipe #2GVL' is no valid identifier I was creating a combo box and creating a TextList for my recipe. I couldn't find where the error was, until in the combo box properties in the 'Text List' property in the options it gives me to select, I found '2,Recipe #2' to be able to select (I never created a list with this name) and I can't find a way to delete that option or I can't find where that list is. I tried to delete the TextLists, delete the combo box, to clean the project, but the error still there. How can I delete this option (2,Recipe #2)? Or how can I fix this error?** Thank you.
Last updated: 2025-06-19

Profinet Simulator CODESYS Forge talk (Thread)
Profinet Simulator
Last updated: 2025-06-20

Post by taoufikaoun on Profinet Simulator CODESYS Forge talk (Post)
Hello, I am new to codesys i want to create 100% simulator profinet network only with virtual ethernet adapter it is possible. I want to use Codesys build in controller and device io for profinet. Thanks.
Last updated: 2025-06-20

AC_DataLog on Raspberry Pi CODESYS Forge talk (Thread)
AC_DataLog on Raspberry Pi
Last updated: 2025-06-20

Post by davidbo on AC_DataLog on Raspberry Pi CODESYS Forge talk (Post)
As seen on the attached file I have indeed installed the library AC_DataLog everywhere, but I cannot add a DataLogManager anywhere Why? I am using an old IDE V3.5 SP18
Last updated: 2025-06-20

Post by taoufikaoun on Profinet Simulator CODESYS Forge talk (Post)
Hello, I am new to codesys i want to create 100% simulator profinet network only with virtual ethernet adapter it is possible. I want to use Codesys build in controller and device io for profinet. Thanks.
Last updated: 2025-06-20

Profinet Simulator CODESYS Forge talk (Thread)
Profinet Simulator
Last updated: 2025-06-20

Post by kevinl on Login to Visu optional CODESYS Forge talk (Post)
hello guys i am struggling with the "new" user management i have a visu that should be visible to everyone and without the need of a login but if a user wants he can push on the login button, opening the user login visu and after he has specific elements visible. how can i achieve that? no matter what i try, as soon as a user management exists, it redirects me to the login window instead of the visu
Last updated: 2025-06-22

Post by nxbp on Cam Editor And Cam Problem CODESYS Forge talk (Post)
I Created cam with 361 cam points ( 0,1,2.....360 ). The values in the Cam_A array do not match the Cam points entered in the Cam editor.
Last updated: 2025-06-22

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Hi CoDeSys support forum, hope that this is the correct place to ask this. Might be double as i am new to Codesys and dont know all terminology. I am trying to test Codesys with a virtual plc on a raspberry pi 5. Already figured that i need Tools -> Deploy Control SL, enter Communication parameters. Codesys says "Connected". Then tab "Deployment", there i select "CODESYS Control for Raspberri Pi SL" and "4.16.0.0 (all)". Click "Install" and the gui turns grey and unresponsive. The titlebar says "Untitled1.project - CODESYS (Not Responding)" as well. Restarting Codesys and checking shows no package was installed. How to deploy the runtime? Thank you in advance for your time. Edit: After some patience, an error showed up: "Error when sending ssh heartbeat: Session operation has timed out" "Error installing codesyscontrol" Any pointers to what remote command might have failed, or log of some sort, would be welcome. Software versions: Codesys version 3.5.21.10 Raspberry pi 5 (deployment machine): $ uname -a Linux raspberrypi 6.1.21-v8+ #1642 SMP PREEMPT Mon Apr 3 17:24:16 BST 2023 aarch64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 11 (bullseye) Release: 11 Codename: bullseye $ apt list --installed | grep openssh-server openssh-server/oldstable,now 1:8.4p1-5+deb11u3 arm64 Development machine: $ uname -a Linux 2B 6.1.0-35-amd64 #1 SMP PREEMPT_DYNAMIC Debian 6.1.137-1 (2025-05-07) x86_64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm VirtualBox Version 7.0.26 r168464 (Qt5.15.8) Virtual OS: Windows 10 Pro 64-bit (10.0, Build 19045) .NET version 4.0.30319.42000
Last updated: 2025-06-22

Post by eschwellinger on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Is sure that on the PI5 is running bullseye, I would expect bookworm. Anyway check if a ssh connection by putty work on this PI5. (use putty for example)
Last updated: 2025-06-22

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23

Post by stulle on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ? CODESYS Forge talk (Post)
Hi, I have the same problem, is there a solution?
Last updated: 2025-06-23

Post by programmer on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Hi, Is there a solution found for the problem described in first post? Any version above Codesys 3.5 P19 hangs during start up. It makes no difference whether I simply start Codesys or open a project directly. I'm using Windows 10 Home edition. Thanks!
Last updated: 2025-06-23

Post by eschwellinger on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
..just use 'putty' ssh client on the virtual machine to login for a test to the pi. if this work it should work in CODESYS too.
Last updated: 2025-06-23

Post by eschwellinger on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ? CODESYS Forge talk (Post)
with latest version? 4.16.0.0? Use the CODESYS Installer to download all required packages if you need an offline installation
Last updated: 2025-06-24

How to download dependencies packages for CODESYS Control for Raspberry Pi SL ? CODESYS Forge talk (Thread)
How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
Last updated: 2025-06-23

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
Is it possible to use MC_Home without enabling the drive (MC_Power)? On the drive the homing method 35 (Homing on current position) has to be executed. The drive has to stay disabled due to safety. This is explicitly allowed by the drive. Unfortunately MC_Home reports the error SMC_REGULATOR_OR_START_NOT_SET when executed. Are there other options to start homing, if not with MC_Home?
Last updated: 2025-06-25

Post by imdatatas on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
Hello, As far as I know, no matter which home mode is selected, the axis must be in Standstill mode to run MC_Home according to PLCopen state machine. However, if the function you want can already be done from a parameter in the driver of the vendor you are using, you can try to perform the same function by sending the required value to that parameter via communication with the SDO write command. Regards, Imdat
Last updated: 2025-06-25

Post by imdatatas on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Hi, You can give a try it by adding "Codesys.exe" in the "Exclusions > Process" section of the Windows Security Center or your antivirus program. I hope it works for your situation. Antivirus programs check many things during both the installation or startup of an application, and may be slow down or block some functions. Regards Imdat
Last updated: 2025-06-25

Post by maxkemmeren on I have errors while building the project CODESYS Forge talk (Post)
Is there any update on what caused the problem? I am running SP19 Patch 5 and having the same errors
Last updated: 2025-06-25

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Yes, the putty connection from within the virtual windows 10 worked. No, the codesys runtime deploy from within the virtual windows 10 did not.
Last updated: 2025-06-25

I have errors while building the project CODESYS Forge talk (Thread)
I have errors while building the project
Last updated: 2025-06-25

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
This is a homing routine which is controlled by setting mode of operation and started by setting a bit in the control word. If MC_Home is not usable for this homing method then I need to implement the same functionality. But how?
Last updated: 2025-06-25