Search talk: REAL to FLOAT

 
<< < 1 .. 204 205 206 207 208 .. 232 > >> (Page 206 of 232)

Post by reinier-geers on Read own network device name CODESYS Forge talk (Post)
Hi. When i scan for devices on the network i get names of the devices. Is there a command to get device name in my programm ? i found : DED.GetDeviceNameString( DED.GetRoot() ); but then i get his name in the programm. not his name in the network.
Last updated: 2026-09-17

Post by reinier-geers on Read a webclient value CODESYS Forge talk (Post)
Hi i get a json value from an energy site. Every hour a value. to cut the answer in an array so i can read every hour it try FindWString . find Marketprice. But it turns in every array on a diverent position. Why ?
Last updated: 2026-10-08

Post by darwin03 on Mismatch between coordinate monitor and actual motion using SMC_GroupJog2, MC_MoveLinearAbsolute (6DOF) CODESYS Forge talk (Post)
Hi Georg, Thank you very much for your help and for taking the time to look into my issue! After reversing the directions of A2 and A3, the robot now moves correctly according to the coordinate system. That solved the main issue with the joint rotation directions. However, I still have two issues: When I command the robot to move along the X, Y, and Z axes, the movement seems slightly off, and the trajectory appears somewhat diagonal instead of following a straight line along the commanded axis. The A6 axis also rotates during the movement, whereas I would expect it to maintain its orientation and remain unchanged. Do you have any suggestions on how I could correct the Cartesian linear movement and keep A6 fixed during the motion? Thank you again for your support! Best regards, Darwin Video link: https://drive.google.com/file/d/1tnokDYoNUEDy--eQtX_JZavMVSn-a9Le/view?usp=sharing
Last updated: 2026-10-15

Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection CODESYS Forge talk (Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03

<< < 1 .. 204 205 206 207 208 .. 232 > >> (Page 206 of 232)

Showing results of 5782

Sort by relevance or date