Post by ferrim on IEC 61499
CODESYS Forge
talk
(Post)
IEC 61499 is probably something more complex than what you have correctly said so the prospects are interesting but we cannot ignore that it came out almost 20 years ago and has not won many hearts. I started to explore this world with a PLCnext controller because I love these devices based on RT Linux and Codesys is somehow usable with them but I have made little progress and I feel like inside a nutshell in the middle of the sea ;-) Gary's voluminous and precious book is always on my desk...
Last updated: 2024-02-10
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
I use the function SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_WRITE, pErrorFileOpen); to open and write a file. Since the update from Codesys V3.5 SP17 to V3.5 SP19 Patch 5 it does not work anymore. I first had SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_APPEND_PLUS, pErrorFileOpen); in both versions. hFile_Test is a pointer to byte. It gives an exceptional error when dereferencing the hFile_Test pointer. Edit: I use Codesys on a Raspberry pi
Last updated: 2024-02-19
Post by wind-11 on Problem with simulation Modbus
CODESYS Forge
talk
(Post)
Hello everyone, I encountered a problem in the simulation while working. In a test project we set up a Modbus connection. We wanted to simulate this with test values. The connection also worked, but unfortunately the values are frozen and do not report any “current data”. (Picture attached) Since these are my first points of contact with Codesys and my colleague continues to work elsewhere, I was hoping that someone here might have an idea. Kind regards and thanks in advance.
Last updated: 2024-03-22
Post by ara32 on CODESYS 4 Linux:
CODESYS Forge
talk
(Post)
Hello! I managed to correctly launch CODESYS Developer Studio 3.5.17, almost all functionality works. The only issue remaining is that when connecting to a device and obtaining its public key, the NCryptEncrypt function is called, which is not fully implemented in the DLL source code, resulting in the connection not being established. Currently, the code of this function in the Wine repository looks like this: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG || flags & NCRYPT_PAD_OAEP_FLAG) { FIXME("No padding and oaep padding not supported\n"); return NTE_NOT_SUPPORTED; } if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } The program crashes due to the NCRYPT_PAD_OAEP_FLAG flag. I'm not proficient in C++, but I attempted to add handling myself, and here's the result: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG) { FIXME("No padding not supported\n"); return NTE_NOT_SUPPORTED; } BCRYPT_OAEP_PADDING_INFO oaepInfo = { 0 }; oaepInfo.pszAlgId = BCRYPT_SHA1_ALGORITHM; NTSTATUS status = BCryptEncrypt(key_object->key.bcrypt_key, input, insize, &oaepInfo, NULL, 0, output, outsize, result, flags); if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } Now, when calling the connection, it crashes with the error "bcrypt:BCryptEncrypt flags 0x4 not implemented." Can anyone help with enhancing this functionality or at least point me in the right direction?
Last updated: 2024-03-22
Post by i-campbell on Publish a JSON payload via MQTT Publish (using IIot Libraries)
CODESYS Forge
talk
(Post)
your are sending as a WSTRING which is UTF16, but your receiver is interpriting as UTF8. Change the receiver to use UTF16, or better change your sender to convert to UTF8. You publish the entire storage space (SIZEOF) Instead of the number of bytes of actual text (StrLenA) try using utf8JsonData : STRING(2000); JSON.Stu.ConvertUTF16toUTF8( ADR(wsJsonData), ADR(utf8JsonData), SIZEOF(utf8JsonData) ); and change your publish to mqttPublish( mqttClient:=mqttClient, pbPayload:=ADR(utf8JsonData), udiPayloadSize:=To_UDINT(JSON.Stu.StrLenA(ADR(utr8JsonData))), wsTopicName:=topic, mQTTPublishProperties:=mqttPublishProperties );
Last updated: 2024-04-10
Post by alez on CANOpen SDO to write VISIBLE STRING
CODESYS Forge
talk
(Post)
Hello, I am experiencing difficulties in configuring a CANopen device by sending SDOs. In particular I am attempting to write an Object Dictionary that has VISIBLE STRING as the Data Type. When I try to configure the sending of an SDO from Codesys to configure this parameter I am not allowed to enter a string value. In my particular case I am trying to change the Manufacturer Device Name ( Index 0x1008 ). Could it be that Codesys doesn't manage these types of variables?
Last updated: 2024-04-29
Post by fless on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
Why will it retain the sum value from the last call? This is how PLC work. Usually variables only get initialized after a download or a reset (i.e. power loss). RETAIN variables are saved in a special kind of RAM and keep their value after a power loss. To initialize variables on every call of your FB use the VAR TEMP block. VAR_TEMP sum : INT; END_VAR
Last updated: 2024-05-07
Post by corriibme on Setting array values with JSON Utilities SL
CODESYS Forge
talk
(Post)
I have been trying to set an array value to a JSON structure of this form: {"key": [1,2,3,4]} While I have been able to create the key and set its value to an empty array, I've not had any luck in putting any value in that array. objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindex); iValue2: ARRAY[0..3] OF INT:= [1,2,3,4]; The two lines of code above produce {"key6": []} . The second line essentially has no effect.
Last updated: 2024-05-12
Post by tomas111 on OPC UA Client API
CODESYS Forge
talk
(Post)
I ran into a problem. Uploaded an example (https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html) After launch. on the emulator. I see that I am having problems: - UaExpert does not connect. There are many servers but no connection. - I can’t transfer the certificate from quarantine to trusted ones. There is some problem with creating the certificate. CS 19.2. If anyone has had similar problems, please give me advice. Thank you.
Last updated: 2024-05-20
Post by shebi87 on Program from one PLC to other WAGO 750-8204
CODESYS Forge
talk
(Post)
Hello Everyone, 750-8204 was installed on a machine and it becomes faulty. We have arrange a new PLC from local market we don't have PLC program but thanks to our other machine which has the same PLC running I want to upload the program from that running PLC and download it to new PLC can anyone tell me the procedure please?
Last updated: 2024-05-21
Post by tba123 on Script engine, git checkout, Project Environment
CODESYS Forge
talk
(Post)
Hi, I clone a git repository with VersionUpdateFlags.SilentMode, works fine But now I want to checkout a specific commit (with branch_copy command). When using the branch_copy command there is no VersionUpdateFlags and I get this annoying "Project Environment" prompt, blocking further execution of my script without user input. I already tried something like system.prompt_answers[???] = PromptResult.Cancel but I don´t know the string I need here.. The goal is to have a script that clones a repository and compiles every tag + create compiled libraries.
Last updated: 2024-06-10
Post by mozed on Bug Device login
CODESYS Forge
talk
(Post)
Good morning, The problem I encounter is very disturbing, when I try to connect to my project, it asks me to put in my username and password, which I do. However, I cannot connect and it restarts. the window to rewrite my identifiers. However it is the correct identifier and password I do not understand why. When I try to put false identifiers there strangely it tells me that these are not valid identifiers. There is something what can I do? Sincerely
Last updated: 2024-06-11
Post by arcadium on TargetVisu element stacking on top of each other
CODESYS Forge
talk
(Post)
Hello, I'm new here so if I do something wrong please bare with me. I am using raspberry pi touchscreen made by comfile (CPi-C070WR4C). I also have a window 11 pc where I would like to have a second visualisation, but when I run a TargetVisu with it, all elements of the visualisation end up in the top left corner stacked on top of each other. I have same results running targetVisu on my laptop. Maybe someone had same issues and know the solution? Simas
Last updated: 2024-06-17
Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Hi We have picked up an issue OSCAT_BASIC.Scale_r function call not working in the old lad and FBD version 4.60. Gives no output on the function call. When we convert this to LAD2 it works. As can be see by the two screenshot in normal LD not working in LAD2 it works. Please confirm if this is an issue with Oscat or with LAD in 3.5.21sp3, is there an workaround. Regards Shaun
Last updated: 2025-10-23
Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Hi We have picked up an issue OSCAT_BASIC.Scale_r function call not working in the old lad and FBD version 4.60. Gives no output on the function call. When we convert this to LAD2 it works. As can be see by the two screenshot in normal LD not working in LAD2 it works. Please confirm if this is an issue with Oscat or with LAD in 3.5.21sp3, is there an workaround. Regards Shaun
Last updated: 2025-10-23
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi Georg OK got it, thank you. I respect your (CODESYS) policies on that issue. Will try to update according to your recommondation if the customer experience same error in the future. Though - from within my coding heart it does bother me deeply, that I cannot get further understanging/knowledge on the iPhasingState, but I guees I will have to swollow that bitter pill and get on with it! hehe ;-)
Last updated: 2025-12-17
Post by ryusoup on 'keep last value' option in CODESYS EtherCAT
CODESYS Forge
talk
(Post)
Hello, I’m using CODESYS EtherCAT Master on a Raspberry Pi controller with several remote I/O modules. I’m facing an issue where the input values from the remote I/Os drop to 0 when a connection error occurs. Is there a way to configure a “keep last value” behavior (i.e., hold the last valid input) instead of defaulting to 0 on communication loss? Best regards,
Last updated: 2025-11-18
Post by gland on Open project automatic with correct version
CODESYS Forge
talk
(Post)
Goodmorning, The projects we have made (with several persons) are in differents versions, Codesys V3.5 sp18 patch4, V3.5 sp19 patch 2, V3,5 sp19 patch 5 etc V3.5 sp21 patch 3 etc.. Now when we're opening an project thats's not opend before on my pc and we're not sure in witch version it's made it's quite annoying. We don't want to update to the newest version. Is there a way that it's automatic opening the correct version? Is there a program/tool/easy way to do this? Thanks,
Last updated: 2026-01-27
Post by nehaltrivedi96 on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
Hello, I am currently scaling 4-20mA signals and the scaled output (temperature) has to be sent via modbus protocol to a tool like doctor modbus or modbus poll. I have defined my inputs as real as and the output is also real, but to send this output via modbus it has to be of word. So how will i convert real into word and then send the generated output via modbus?
Last updated: 2026-02-18
Post by sulzbrunn on Codeys Installation freezes while attempting to install packages
CODESYS Forge
talk
(Post)
Hi, I am facing the same problem: I am trying to install CODESYS 3.5.17.60 The last log entries are: ... InstallShield 14:18:17: Done Initializing... InstallShield 14:18:17: Registering Msi Server... InstallShield 14:18:17: Invoking script function InstallOEMPackages 1: [CDS Info]: CDS_OEMPACKCOUNT: 47 1: [CDS Info]: CDS_OEMPACKCOUNTALL: 47 Action 14:18:17: CDSInstallOEMPackages. Install all Packages added to the setup 1: [CDS Info]: Call: C:\PROGRA~2\CODESY~1.60\CODESYS\Common\PACKAG~2.EXE --profile="CODESYS V3.5 SP17 Patch 6" --installAll="C:\Users\UserXXX\AppData\Local\Temp{94C03~1\Packages"
Last updated: 2026-03-19
Post by risele on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
First, if you don't need to change conversion rules in runtime, take a look at "Unit conversion" module (Application -> add object -> UnitConversion). You can specify there biderectional conversion with different units, limits and so on. Second, since MODBUS don't have "real" types but only general 16-bit registers and Real is 32-bit, generally you need a byte-was conversion Real <> two Words. Note, that depending on the devices on both sides, there are two options: Real-> Word1, Word2 or Real-> Word2, Word1, where Word1 is minor register in Modbus register pair and Word2 is major. You can use simple union: TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE and convert it as following: VAR myUnion:u_Real; rValue_TO_SEND:REAL; rValue_TO_GET:REAL; END_VAR myUnion.rVal:=rValue_TO_SEND; rValue_TO_GET:=myUnion.rVal; Note, that WORD-order should be properly set in MODBUS registers, otherwise you will get strange values. This tool is helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/ Alternative, you can use functions as REAL_TO_DW and DW_TO_REAL from OSCAT_BASIC, for example.
Last updated: 2026-02-19
Post by vincentger on Raspberry Pi Control SL MC - Restoring License not working anymore!
CODESYS Forge
talk
(Post)
Running into the same problem restoring a Runtime 4.4.0.0 device on a now 4.8.0.0 device.
Last updated: 2023-08-21
Post by eschwellinger on Raspberry Pi Control SL MC - Restoring License not working anymore!
CODESYS Forge
talk
(Post)
you need to use 'my question ' in the CODESYS store
Last updated: 2023-08-24
Post by smercante on Unable to Import PLC Open XML from Easy Remote IO
CODESYS Forge
talk
(Post)
Hello dear. I have the same problem. Could you solve it? Do you use GLV variables?
Last updated: 2023-08-24
Post by gregor on PFC 200 - codesys V3.5
CODESYS Forge
talk
(Post)
As far as I know, only if someone downloaded sourcecode to the PLC.
Last updated: 2023-08-25
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.