Post by jeffg on ERROR: GetNetLinkSockAndInfoByMac(): could not open netlink socket: Too many open files
CODESYS Forge
talk
(Post)
I just installed codesys runtime on a raspberry pi Cortex-A72 (ARM v8) 64-bit SoC @ 1.5GHz (Compute Module 4) I am running on Codesys control for raspberry pi 64 SL ver 4.13.0 and I keep getting a crash after about five to ten minutes. This program was running fine on a 32bit system with runtime 4.8 previously but they upgraded the panel PC cause it got smashed. Looking at the logs I see this error "ERROR: GetNetLinkSockAndInfoByMac(): could not open netlink socket: Too many open files" at the time of crash. I do have a UDP socket open for a serial to ethernet adapter and im wondering if maybe its opening a bunch of sockets and while receiving messages, Im not sending anything to the device only receiving. Below is the code used for the UDP VAR // Scale Comm fbPeerServer : NBS.UDP_Peer; ipAddress : NBS.IPv4Address; fbReceive : NBS.UDP_Receive; xPeerActiv : BOOL := TRUE; abyReceive : ARRAY [0..255] OF BYTE; sLastValidReceive : STRING(255); udiIndex : UDINT; END_VAR IF xPeerActiv AND NOT fbPeerServer.xBusy THEN ipAddress.SetInitialValue(ipAddress := gvlSettings.sIPAddres); fbPeerServer(xEnable := TRUE, itfIPAddress := ipAddress, uiPort := gvlSettings.uiPort); END_IF fbPeerServer(); fbReceive(xEnable := fbPeerServer.xBusy, itfPeer := fbPeerServer, pData := ADR(abyReceive), udiSize := SIZEOF(abyReceive)); IF fbReceive.udiCount > 0 THEN IF fbReceive.udiCount < SIZEOF(sLastValidReceive) THEN SysMem.SysMemCpy(pDest := ADR(sLastValidReceive), pSrc := ADR(abyReceive), udiCount := fbReceive.udiCount); // Set End of String sLastValidReceive[fbReceive.udiCount] := 0; END_IF END_IF If anyone as seen this I could really use some help figuring it out. I included the Log report
Last updated: 2024-09-19
Post by deeps on web visu on IFM
CODESYS Forge
talk
(Post)
I have an IFM cr1077 display. I would like to show B&R mapp view on IFM visualization. I used coedsys web browser elemnt for this. I could see IFM working fine in Internet web browser but IFM device shows white screen and freezes. I think there is problem with IFM showing the web browser. Is my understanding of the web visu right? am I doing any mistake here?
Last updated: 2023-08-18
Post by arnog on Two drives on one axis, Gantry Robot
CODESYS Forge
talk
(Post)
Hi TK_Jenssen did you found a solution I am setting up the samelike gantry only with two z-axes which are mounted on fix position with an X axes between the two z-axes. The movement and position of both z-axes must be very well aligned and calibrated. Maybe also to be adjusted by programming. Can you sent an example of your solution?
Last updated: 2023-08-25
Post by john-ronald on Communication error (#0), logout performed,please check if plc is connected
CODESYS Forge
talk
(Post)
Hi, I have the same problem. However I am using ethernet connection not USB. I can ping the PLC and also connect to it via Wago ethernet settings, but I cannot upload using the Codesys 2.3. My PLC is Wago 750-862. The detailed error is - " connect: Connection refused Write attempt from invalid socket. " Any help would be appreciated.
Last updated: 2023-09-11
Post by transmin01 on PCAN serial "No CAN driver found"
CODESYS Forge
talk
(Post)
Hi, I am using a PCAN mini CAN board which has the Windows drivers installed on the target PLC. PCAN board can be seen in device manager. However, I am getting "No CAN driver found" error. I have read the post https://forge.codesys.com/forge/talk/CODESYS-V2/thread/44aae19318/ and have uncommented the CmpPCANBasicDrv driver in the CodesysControl.cfg file in development PC and have copied it to the target PC. Current CodesysControl.cfg file attached. Is there anything else I am missing? Regards
Last updated: 2023-09-14
Post by damian177 on Codesys and SMS in RPi
CODESYS Forge
talk
(Post)
Hi, I try use IIoT library to send and receive SMS by Raspbery PI and Codesys. I installed IIoT package and added the SMS library, But something is wrong, when I init communication it doesn't work, When I sniffer my communication (AT commands) beetwen RS232 RaspberryPi and my GSM modem I have only below commands: AT+CMEE=1 OK AT+CPIN? +CPIN: READY Anyone have idea what can be wrong ?
Last updated: 2023-09-28
Post by mondinmr on Jitter problems on imx8
CODESYS Forge
talk
(Post)
SOLVED!!! In this imx8 max_cstate=1 in kernel boot parameters is not working! We found a workaround: #include <stdio.h> #include <fcntl.h> #include <unistd.h> #include <stdint.h> int main(void) { int fd; uint32_t value = 0; fd = open("/dev/cpu_dma_latency", O_WRONLY); if (fd < 0) { perror("Error opening /dev/cpu_dma_latency"); return 1; } if (write(fd, &value, sizeof(value)) != sizeof(value)) { perror("Error writing to /dev/cpu_dma_latency"); close(fd); return 1; } while (1) { pause(); } } This simple code launched before CODESYS do the same work! Now jitter is identical as measured by cyclictest!
Last updated: 2023-10-19
Post by simotion on Online view : code is scanned
CODESYS Forge
talk
(Post)
If I do online monitoring of code in f.i. a function block, I cannot see if the function block is called or not. In software from other vendors you normally have an indication if the online code you are looking on is scanned at that moment or not. Is there a way in Codesys to determine in the online view if (parts) of the code are scanned or not? Thanks
Last updated: 2023-10-23
Post by simotion on Inheritance of axis
CODESYS Forge
talk
(Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07
Post by taqamert on Codesys 2.3 & Peak PCAN
CODESYS Forge
talk
(Post)
Despite working on it for days, I haven't achieved any results. I followed the necessary steps one by one as mentioned in the file you sent, but there hasn't been the slightest change. I couldn't find the step you mentioned "Set the 'Can Board Type' to PCAN USB" in the Word document. There is no such setting anywhere I looked. Is there a more detailed explanation available, or can you explain it in more detail? What am I missing?
Last updated: 2024-07-16
Post by kislov on Change modbus server parameters from program
CODESYS Forge
talk
(Post)
Use in IEC-code: Modbus_Serial_Device.UpdateComPortSettings(...) https://content.helpme-codesys.com/en/libs/IoDrvModbusSerialSlave/Current/pou-ModbusSerialDeviceDiag/UpdateComPortSettings.html Take note: "Only possible if server is disabled (see xEnable Input)" So: Modbus_Serial_Device.xEnable := FALSE; Modbus_Serial_Device.UpdateComPortSettings(...) Modbus_Serial_Device.xEnable := TRUE; Please note that after PLC reboot the values from the GUI (from your screenshot) will be applied again. So you need to save values from HMI in RETAIN and restore them after start of application.
Last updated: 2024-07-17
Post by schweizer on Position und GrΓΆΓe optimal anpassen (Container.Height - Visu.Height) funktioniert nicht.
CODESYS Forge
talk
(Post)
Hello forum Does anyone have experience with optimally adjusting the position and size of the visualization elements? For us, the adjustment on the x-axis works in Codesys 3.5 SP20 with (Container.Width - Visu.Width). However, the y-axis is not affected with (Container.Height - Visu.Height). We implemented this according to the example from Codesys "Optimally adjust position and size" and had no success. Thank you very much for your help.
Last updated: 2024-07-29
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by anuj9326 on OPC-UA Client connection, Linux SL /Raspberry Pi
CODESYS Forge
talk
(Post)
hello edwin i have did the same and i could connect the opc-ua server but i dont see anything in the resources tree, in the application i linked my variables to the symbol configuration but i dont see that in the uaexpert. if i use the same application with a non linux system i can get those variables values and see the complete tree structure. What could be the problem ?
Last updated: 2024-08-21
Post by anuj9326 on OPC-UA Client connection, Linux SL /Raspberry Pi
CODESYS Forge
talk
(Post)
hello edwin i have did the same and i could connect the opc-ua server but i dont see anything in the resources tree, in the application i linked my variables to the symbol configuration but i dont see that in the uaexpert. if i use the same application with a non linux system i can get those variables values and see the complete tree structure. What could be the problem ?
Last updated: 2024-08-21
Post by taqamert on IFM-Sensor ADC READ
CODESYS Forge
talk
(Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23
Post by taqamert on IFM-Sensor ADC READ
CODESYS Forge
talk
(Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23
Post by taqamert on IFM-Sensor ADC READ
CODESYS Forge
talk
(Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23
Post by dkugler on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
I can confirm that at my 4ms EtherCAT Master the frames per second is equal at round about 500 with Codesys SP19. The same program at SP16 it was at 380-430 f/sec. for me it will be interesting too, whats the reason is for this high frame count/sec? I havn't had the time to use a paket sniffer and analyse all the frames. I can't help with your other questions, sorry.
Last updated: 2024-09-19
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by garmusd on Raspberry Pi 5 GPIO not working.
CODESYS Forge
talk
(Post)
I paid money for the RPi runtime because the Product Description says that GPIO is supported. It is also written in the Versions that since 4.11 RPi5 is supported. And I use 4.13. Nowhere is it mentioned that GPIO is still not supported... It's a pity that the Codesys developers still can't find a way to fix it. Are there plans for when it will be fixed or are the developers too weak? Just wondering, is there anyone with a working GPIO? Can you share the details of your system?
Last updated: 2024-09-27