Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
The voltage what i want to measure is 3.286v. I can check the voltage through terminal, see screenshots.
Last updated: 2024-11-08

Post by eschwellinger on More information on Device address [0058.A0DE] CODESYS Forge talk (Post)
no nowadays I would recommend connect by name. Which is the default I guess since some versions.
Last updated: 2024-11-22

Post by akfarslan on The application does not exist on "device" CODESYS Forge talk (Post)
Dear All, I am using CODESYS 3.5.19 SP4 with a PLC device. When I try to download my program to the device, I get the error: "The application 'Application' does not exist on the device". Additionally, after restarting the device, the program does not run automatically. When I connect to the device using WinSCP, I can see that the application.app file is uploaded to the root directory, but the device does not automatically start the application. I tried using the Create Boot Application option, but it does not resolve the issue. Is there another configuration step I am missing? How can I fix this problem? Thank you, Best regards,
Last updated: 2024-12-17

Post by pernockham on Slider instance value when accessed through "execute ST-code" CODESYS Forge talk (Post)
I have a time which I want to modify with a slider. I have confirmed it is possible to set the value of the slider by to_real(time) (I can see that the slider changes according to 'my_time_value's value). Slider variable: to_real(my_time_value); However I fail to access the current slider instance value when I want to write back the value as time (write to a variable will not work as I need a type-conversion before assignment). my_time_value := to_time(slider-instance-value); I tried with this^.? but could not see anything interesting and also THIS^.GEN_Instance.? but nothing resemble what could be the sliders value. Anyone that knows? Thanks!
Last updated: 2025-02-06

Post by pernockham on Slider instance value when accessed through "execute ST-code" CODESYS Forge talk (Post)
I think this will not work. I reworked and used an int as source instead.
Last updated: 2025-02-07

Post by tyleretn on Codesys 3.5 SP18 P4 Freezing on Library Update CODESYS Forge talk (Post)
I have created a library with both code and visualizations to be used in multiple other projects. After I update the library version into the library repository, I have much difficulty updating the version into the main project. I can always update the library version in the Library Manager just fine. My issue, is sometimes Codesys will freeze when opening the visualization that uses the library visualizations. Sometimes it opens, but freezes when I try to access the library visualizations from the Visualization Toolbox. I try letting Codesys run for upwards of 4+ hours and it is stuck in this state. On very rare cases I have no issues and can continue with my work. I haven't found a consistent reason or work around. Has anyone else had this happen?
Last updated: 2025-02-27

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the logic application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the HMI application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06

How do I parse the following non-standard M code expression in CODESYS? CODESYS Forge talk (Thread)
How do I parse the following non-standard M code expression in CODESYS?
Last updated: 2025-03-24

Post by agentcousto on [Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8 CODESYS Forge talk (Post)
Hello, I have developed a Python script that I run to import XML files into my project. For this, I use the Python function import_xml(). Everything was working fine when I was using Codesys platform plugins version 2.6.1.2320, but since I upgraded to versions 2.7 and even 2.8, some files are no longer imported correctly. After some research, I identified that all the files containing variables of the type "POINTER TO" are affected. I have attached a screenshot of the error I am encountering. Do you know about this bug? Do you plan to fix it?
Last updated: 2025-03-26

Codesys PFC200 Runtime, no log after reboot, can I get a Post-Mortem log? CODESYS Forge talk (Thread)
Codesys PFC200 Runtime, no log after reboot, can I get a Post-Mortem log?
Last updated: 2025-03-31

How do I fix ";Internal Error (x86-64): Invalid type size" error? CODESYS Forge talk (Thread)
How do I fix ";Internal Error (x86-64): Invalid type size" error?
Last updated: 2025-04-16

Post by andrej on Creating, using an external Function. CODESYS Forge talk (Post)
Hello all, I would like to create a simple which runs directly on Control WinV3 x64 3.5.21.0 For this purpose I created a simple dll myAdder.dll in Cpp // MyAdder.cpp // cl /LD /EHsc MyAdder.cpp /Fe:MyAdder.dll #include <windows.h> extern "C" __declspec(dllexport) int __cdecl CmpMyAdder_Add(int a, int b) { return a + b; } I added the dll in the respective folder. Furthermore I "registred" the dll in the CODESYSControl.cfg. However, when I want to use the library I get the error message: Uresolved reference: *'CMPMYADDERADD' * Can you give me a hint what step I missed or where I need to declare the dll, such that the dll resp. the reference can be resolved. Many thanks and kind regards
Last updated: 2025-04-18

Post by davcide on button-keyboard CODESYS Forge talk (Post)
hi i have codesys v3.5, i should associate a button to a keyboard key with the ladder code. can you help me
Last updated: 2025-05-14

Post by maxkemmeren on I have errors while building the project CODESYS Forge talk (Post)
Is there any update on what caused the problem? I am running SP19 Patch 5 and having the same errors
Last updated: 2025-06-25

Post by davidbo on RTSEXCEPTION_NOEXCEPTION with Date/Time picker CODESYS Forge talk (Post)
Using in a visualization the Date/Time picker I get an RTSEXCEPT_NOEXCEPTION as soon as I change any date value. Why?
Last updated: 2025-06-27

How do I stop/start logging in my code using AC_Datalog with composer CODESYS Forge talk (Thread)
How do I stop/start logging in my code using AC_Datalog with composer
Last updated: 2025-07-07

Where can I find a list of all available runtime configuration parameters ? CODESYS Forge talk (Thread)
Where can I find a list of all available runtime configuration parameters ?
Last updated: 2025-07-10

Post by fedex03 on Read Global Variable from an IoT Device CODESYS Forge talk (Post)
Hello everyone, I am new to the forum, and to programming with CodeSys. I am dealing with IoT device for industry and I should check if a device is able to read/write global variables in an EtherNet/IP Master. Since I do not have an EtherNet/IP PLC, I thought of using CodeSys as a softPLC. I created a program with a set of global variables (GVL) and a task that increments them. I would like to know if I need to enable any options so that the global variables can be read by IoT devices. My device supports Class 2 Class (Explicit Messaging Connection) communication. Thank you in advance for your help.
Last updated: 2025-07-22

Post by pedromarquez on Codesys C Implemented Library CODESYS Forge talk (Post)
I have the same situation i manged to import the library but there is no documentation in how to use it
Last updated: 2025-07-24

Post by pedromarquez on Codesys C Implemented Library CODESYS Forge talk (Post)
I have the same situation i manged to import the library but there is no documentation in how to use it
Last updated: 2025-07-24

Post by micik on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore CODESYS Forge talk (Post)
I have a test application and use Codesys Control for Rasp Pi SL. I made a mistake and updated device from MSL to MC SL, and now if I try to go online with archived version of the project I gett error message that IDs are different between project device and target device. Of course, I can go online if I changed device in the project from SL to MC SL, but I'm not sure that is correct. So I have two questions: 1. What is the actual difference between MC SL device and standard SL device when it comes to raspberry pi 4? 2. What change I need to do on raspberry pi4 side to change device back from MC SL to SL? Thank you!
Last updated: 2025-08-05

Post by wagokurt on TargetVisu option missing in IDE CODESYS Forge talk (Post)
When I open the project, I always get this notice. It never actually updates the CmpTargetVisu.. Is this a bug?
Last updated: 2025-08-22

Post by nilanjan on I want to show the current recipe name in the visualization screen CODESYS Forge talk (Post)
Thanks for the reply and suggetion I will try to automate the above process
Last updated: 2025-09-17

I want to show the current recipe name in the visualization screen CODESYS Forge talk (Thread)
I want to show the current recipe name in the visualization screen
Last updated: 2025-09-17