Post by ricola on Change default node Id name on Raspberry Pi
CODESYS Forge
talk
(Post)
EDIT : https://forge.codesys.com/forge/talk/Engineering/thread/cb5a492aa0/ hyplcmotion - 2022-12-16 Found out how! Needed to connect to PFC200 via Putty, and open CodesysControl.cfg with “sudo nano /etc/CODESYSControl.cfg”. Then adding following command to the end of file, and use the name you want, save/close CODESYSControl.cfg, and reboot your PLC. [CmpOPCUAProviderIecVarAccess] CustomNodeName= PFC200 Hi! , I'm digging up this issue cause we have still this long name within current versions on CodesysControl. Is it a lock for "demo" licences or can it be changed in some way ? This DeviceSet name is too way long with spaces inside, not easy to handle with string parsing... Cheers !
Last updated: 2024-10-10
Post by spoun on Problem with edge gateway config mode
CODESYS Forge
talk
(Post)
Hello, i want to connect my automation server and i follow the steps as desribed in the video series(https://www.youtube.com/watch?v=iiPKyyO4M00&list=PLaws15OZmd7Uu2W23zX2w424aI3TrOfHf) and also that guide (https://content.helpme-codesys.com/en/CODESYS%20Automation%20Server/_cas_add_plc_to_server.html). When i go to "Allow Edge Gateway configuration.." from the Codesys gateway Systray running i get the message in the attached picture, so i open the Gateway.cgf but the file doesn't contain an cmpedgegateway section as mentioned in the message. I have installed all the latest versions codesys and of the components mentioned in the guides. How can i solve that problem?
Last updated: 2024-10-21
Post by simone on Collapse all
CODESYS Forge
talk
(Post)
Hi, I'm wondering if it exist a button or a keyboard shortcut (much much better) for "collapse all" the open folder on a codesys project. It would really be nice to have. Also: Are there some options or configuration for set a default zoom for the different editor (or even one global), for example I would like to have 100% on ST, LD editor and have 80% on Visualization Editor; and also have a button to set all the zooms to default, now it seems that every file mantain the one previously set. I'm working with the 3.5.20.10 right now Thanks!
Last updated: 2024-11-21
Post by micik on How to generate an "ENI" file
CODESYS Forge
talk
(Post)
That really depends on this third party software you want to use. It is possible that .xml file generated with "Generate EtherCAT XML" will not be recognized as valid ENI file. Anyway, "Generate EtherCAT XML" command is not available through standard menus and needs to be added via Tools->Customize and then Add Command. You'll find it under "Devices" section. If you provide more info, we might be able to help you further.
Last updated: 2024-08-09
Post by imdatatas on Import from XML problem
CODESYS Forge
talk
(Post)
Hello Everyone, When I try to import some POUs that were previously exported from another project as an XML file, I get an error like in attached image and the process does not complete. "There are no objects in the export file..." I am using SP21 Codesys IDE and I do not know which version this XML (*.export) file was previously exported with. Has anyone encountered the same problem? Regards, imdatatas
Last updated: 2025-04-26
Post by yann2021 on Execute a .py file with Codesys
CODESYS Forge
talk
(Post)
Hello, I have a Raspberry Pi 3 which has a printer connected to his USB port. I have a PiFace Board on the Raspberry. I have a python script file (.py) to print a logo + a text. The script is working because when I execute it from the Raspberry terminal it works. Now, when I push a button on the PiFace I would like to execute the python script file to print. How can I do that ? Many thanks for your help and advices!
Last updated: 2025-08-26
Post by richard-wang on Codesys recipe manager - what does it do?
CODESYS Forge
talk
(Post)
Hi All Thanks for sharing this information. For whom may not know why always get error code 16#4000 or 16#4002 while performing Recipe commands, the root cause is There is a line need to be inserted in CODESYSControl.cfg file, which is PlaceholderFilePath.1=/var/opt/codesys/PlcLogic/ I am using Pi, therefore the above path is set to my pi unit, after adding above line to my cfg file, all the Recipe commands work fine. But I still do not know how and when this file got modified though.
Last updated: 2024-04-29
Post by youness on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
I have Already the same problem when i'm trying to write data more than 10 times in the same file. In fact, i send my data periodicaly to a file that i configured to have permission of W/R in my CodesysContol.cfg. When the Error occurs, i must reboot my machine to success. It means that the problem isn't realted to a limitation of size, but a problem in the function supposed to handle the file. totorovic : allow me to know if you've found a solution to your problem. Thanks.
Last updated: 1 day ago
Post by kbazzett on "Sequent Microsystems" industrial automation hat raspberry pi
CODESYS Forge
talk
(Post)
Here is a complete list of the Sequent Microsystems Pi hats that work in Codesys. https://github.com/SequentMicrosystems/SM_CODESYS/tree/main/ "For easy install download the .package file and open it on your computer, Codesys installer will know what to do with it." <- This. The Multi I/O Hat fit my needs because of the Analog I/O 4-20ma and RTD. I used a Raspberry Pi 5 and 64b install. The example project is also worth the download. With the sample project open, right click on the Raspberry Pi device and update to whatever you are using (SL, MC, 64b). Enable I2C on the PI. You can jumper the hats Analog Outputs to Inputs and see it function on the Web Visualization. Very Cool! I spent quite a bit of time trying to find this solution so hopefully this update helps others. Here is the video link on how to setup a Raspberry PI as a Codesys PLC https://youtu.be/RPoPscbo3Kc?si=Th4-n-mQ6g5fdHj8
Last updated: 2024-12-05
Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
Should I be looking for anything in particular in the PLC Log? Attached is the xml file from the PLC logger.
Last updated: 2023-09-26
Post by ronald-de-jonge on Codesys StructType in Device Description File
CODESYS Forge
talk
(Post)
We have the same issue when using CODESYS V3.5 SP18 Patch 2. Is there a solution for this issue?
Last updated: 2023-10-30
Post by kumareasu on Runtime System Update
CODESYS Forge
talk
(Post)
When I change the hardware Do I need to buy licence After three years ? Please refer the jpg file.
Last updated: 2023-11-26
Post by snhatton on Saving variable values on power cycle (RevPi Connect)
CODESYS Forge
talk
(Post)
Have you tried using the persistence manager which uses the file system of the controller to store persistent variables?
Last updated: 2023-12-04
Post by wollvieh on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win
CODESYS Forge
talk
(Post)
https://forge.codesys.com/forge/talk/Runtime/thread/a113f7c93b/#5938
Last updated: 2024-07-04
Post by vladimirsmall on Send data to USB
CODESYS Forge
talk
(Post)
Hello/ Need send some file ( for example Array of string) to USB. Which library need used for this. Thank you
Last updated: 2024-07-20
Post by mikek10 on Connection error to Wago 750-363 EtherNet/IP Adapter
CODESYS Forge
talk
(Post)
This file is still useful but no longer available?
Last updated: 2024-07-22
Post by faceplant on Get the .git folder path via scripting
CODESYS Forge
talk
(Post)
Using the git scripting API, is there any way to get the file path of the project's .git/ folder?
Last updated: 2024-08-08
Post by justthefacts77 on How to generate an "ENI" file
CODESYS Forge
talk
(Post)
I think this is really now "Generate EtherCAT XML" command which gives the ENI topology info.
Last updated: 2024-08-08
Post by mubeta on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
Here is the archive of the simulation project: https://drive.google.com/file/d/1n74Qy-1yLPpI2OK4FaZO5q50y2uTa0Wr/view?usp=drive_link
Last updated: 2025-01-12
Post by eschwellinger on File Creation Issue
CODESYS Forge
talk
(Post)
use the PLClogic directory to read / write files. /var/opt/codesys/PlcLogic this is due security reasons forced to use.
Last updated: 2025-03-04
Post by sakthivel on Library Files missing Issue
CODESYS Forge
talk
(Post)
Whn opening the backup file in codesys it showing error (The following librarirs could not load - UNPACK16.lib, IEEE754 library_P.lib
Last updated: 2025-05-15
Post by nz-dave on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
So did you get it working?
Last updated: 2025-05-27
Post by chsp on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Hey CODESYS, we are in 2025. Did you hear about Gibhub Copilot and alternatives? Any ideas?
Last updated: 2025-06-08
Post by tk096 on SMC_ReadNCFile2 is always busy
CODESYS Forge
talk
(Post)
Hi, the subsequent interpreter should report an error? The reader is just reading the file without checking the syntax.
Last updated: 2025-06-17