Post by jeindhoven on Deploying to raspberry pi 5 hangs
CODESYS Forge
talk
(Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23
Post by westcountryewe on ac_persistence not working when creating a Boot Application but works with a Direct Download to the PLC
CODESYS Forge
talk
(Post)
I am using V3.5 SP18 Patch 5. I have noticed that when I Create a Boot Application from CODESYS, and upload this to my PLC via a USB stick the AC_Persistence does not work and none of my values that are in my PersistenceChannel are retained. However, if I connect direct to my PLC and I perform a direct download of my CODESYS program, my values that are in my PersistenceChannel are retained and work as they should. This makes me wonder if there are files that are missing when a Boot Application is created. I have tried taking a backup of my configuration files after performing a direct download, which gives me the plclog.zip folder, and appears to have the ac_persistence folder present within the file structure, however when I replace the plclogic.zip with the same folder that was created when I created a Boot Application, it still does not work but I wonder whether this is because the ac_persistence folder isn't stored in the correct location for reading. The .app and .crc files are embedded within the plclogic.zip folder, which obviously when uploading need to be standalone files in the root directory of the USB, so the intention there is clearly to extract the .app and .crc files and put them into the correct location within the USB. I wonder if it could be the same for the ac_persistence folder? I have tried moving it to different locations but none have worked. Has anybody else discovered a fix for this? I know the short-term solution is to do a direct download to the PLC but there are some logistical reasons why this isn't neccesarily the best solution for us.
Last updated: 2024-02-27
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins
CODESYS Forge
talk
(Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15
Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins
CODESYS Forge
talk
(Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15
Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins
CODESYS Forge
talk
(Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15
Post by manuknecht on Maximum dynamic limits of MC_MoveLinearAbsolute and MC_MoveLinearRelative
CODESYS Forge
talk
(Post)
Hello all I use an axis group with two linear axes in a kinematic system. Using MC_MoveLinearAbsolute and MC_MoveLinearRelative, I am trying to realise dynamic movements (set velocity: 1 m/s, set acceleration: 30 m/s^2) with the highest possible jerk, as I want to compare this with a movement with a trapezoidal velocity profile. However, my measurements show that the axes accelerate with a maximum jerk of approx. 800 m/s^3, even if the value in the function block was set to 10,000 m/s^3. I have already increased the dynamic limits of the two axes accordingly (Velocity: 5000 u/s, Acc-/Deceleration: 250'000 u/s^2, Jerk: 100'000'000 u/s^3, where 1 u = 1 mm), but this had no effect. I have checked the input parameters of the function blocks and the VelFactor, AccFactor and JerkFactor factors are all set to the maximum (value 1). Reducing the cycle time has resulted in a higher jerk, but as we are already working with a cycle time of 1 ms, there is nothing more that can be done here. The axes themselves are still a long way from drawing the maximum current, which is why I assume that this should not be a problem either. Are there other factors or parameters that influence the dynamic limits and therefore allow faster movements? The PLC I am using is a Raspberry Pi 4 and Codesys V3.5 SP20 with all libraries up to date. Thanks in advance Manuel
Last updated: 2024-05-08
Post by alexgooi on Codesys KNX implementation
CODESYS Forge
talk
(Post)
Dear forum, We are currently doing some research on the Codesys KNX implementation (https://store.codesys.com/en/codesys-knx-sl.html). We almost have it working but we are missing the last part. The setup: We have a Codesys virtual control container running on docker (4.17.0.0), the I/O is running over an Ethernet IP coupler (Weidmüller), and this is running fine. As far as I’m concerned this tells me that the ethernet device is working properly (the container has access to the outside world, including multicast). Underneath this ethernet adapter the KNX module is added (see picture). In the KNX device (Codesys) 2 input variables are added (see picture), and these are exported to ETS (ETS 5). In ETS A Codesys KNX device has been imported and the Codesys export was imported, afterwards the group addresses are attached to the variables (see picture). Afterwards this configuration is downloaded to the Codesys controller (Container) via ETS. ETS asks for the pressing of the programming button, when the virtual programming button is pressed the download starts and finishes without any errors. This tells me that ETS is communicating with the Codesys controller, and that the download process is ok (so far so good). Now the part where we are struggling with, somehow we need to convert the KNX TP to KNX IP. For this we have the following interface: Zenio KIPI SC (https://www.zennio.com/product/kipi-sc/) this is a KNX TP to IP interface. We have the following setup for this device (see picture) (an IP in the same subnet is used). We tried multiple combinations of IP addresses but the TP devices are simply not communicating to the Codesys container. Does anyone has any advice on what to try next. To make the question more explicit how can we link the TP bus to the Codesys device? Kind Regards Alex
Last updated: 2026-01-05
Post by struccc on Inheritence of struct,
CODESYS Forge
talk
(Post)
Strangely reminds me to my struggles... Want to do something "Elegant", reusable, universal, practical... In CODESYS??? 🙃 First of all, before you get too deep into this: If you could find a way, to make a "universal" log entry object, containing the variable length data itself, you wouldn't be able to store them in an array, or access them like an array, or pass them by value as a type. (please correct me, if I'm wrong, incorrect, or not precise). Because... Basically you can't declare a type with variable memory footprint. This is a very deeply embedded characteristic of CODESYS, and all IEC 61131-3 systems, and it has many reasons behind. And yes, it is a very common trap / mistake, to forget about. So, with a log entry - I guess - it's pretty much the purpose: store data and metadata together, and then handle it in a uniform way. There are ways to handle this, really depends on what is the purpose. For example: 1. Entries with fixed length (Maybe it is not as evil as it looks for the first time. Depends on the situation, but definitely the fastest and easiest code) You can have your base object, with an internal, fixed length string or byte array variable. I would go with a string, and call it _Data.; And then you can make properties, like As_Bool, As_Int, As_Real... In the 'set' accessors, you can do like: pReal := ADR(_Data); // POINTER TO REAL As_Real := pReal^; In the 'get' accessors, evidently: pReal := ADR(_Data); // POINTER TO REAL pReal^ := AS_Real; Or, can use ANY type, if you are not obsessed with variable / property like access: 2. Fixed length, but nicer First, some disadvantage to any values: - You can only assign values with write access. No literals, constants, etc... - Can only be used as input variable of function or function_block - Therefore, stg you could reach: LogEntry.Initialize (stVariable|rVariable|iVariable|xVariable); Just a quick example (it's funny to play with ANY): Be careful it was not tested. I'm sure can be done better, please feel free to comment FUNCTION_BLOCK FB_LogEntry VAR_INPUT MsgClass : UDINT; // Like DEBUG, WARN, ERR... MsgCode : UDINT; // Like Errors.ERR_FAILED MsgTS : DT; // The timestamp END_VAR VAR _Data : STRING(80); // Our data container... _Descr : __SYSTEM.AnyType; // A standard descriptor for our data, containing TYPE_CLASS, address and size END_VAR METHOD SET_Value : BOOL VAR_INPUT anyValue : ANY; END_VAR VAR I : DINT; diSize : DINT; pStr : POINTER TO STRING; END_VAR // Check what did we receive in anyValue. diSize := anyValue.diSize; // We use constant __SYSTEM.TYPE_CLASS to identify the received data type CASE anyValue.TypeClass OF // Maybe we don't want to store references, pointers... and who knows what else... __SYSTEM.TYPE_CLASS.TYPE_REFERENCE, __SYSTEM.TYPE_CLASS.TYPE_POINTER : SET_Value := FALSE; // For the planned types we will be just fine. TYPE_CLASS.TYPE_BOOL, TYPE_CLASS.TYPE_INT, TYPE_CLASS.TYPE_REAL : SET_Value := TRUE; // Optionally string can be handled separately, maybe we have received STRING(255), but practically it is shorter than 80 bytes... TYPE_CLASS.TYPE_STRING : pStr := anyValue.pValue; diSize := MIN(anyValue.diSize, LEN(pStr^) + 1); // Get the actual size, and rewrite the received structure member diSize := MIN(SIZEOF(_Data), diSize); // Can chop down the received string to our length... SET_Value := TRUE; // Maybe want to play a little bit more here, to narrow down or convert datatypes, etc... // Or just reject any other datatype ELSE SET_Value := FALSE; RETURN; END_CASE // Fail, if the received value is still larger than our container... IF diSize > SIZEOF(_Data) THEN SET_Value := FALSE; END_IF // Here we should be ok, just set up the _DataType structure, and copy store the data IF SET_Value THEN THIS^._Descr.TypeClass := anyValue.TypeClass; // The typeclass is already filtered THIS^._Descr.diSize := diSize; // Set the (adjusted) size THIS^._Descr.pValue := ADR(_Data); // This will not change, just to be sure {IF defined (pou:SysMem.SysMemCpy)} SysMem.SysMemCpy(_DataType.pValue, anyValue.pValue, TO_UDINT(anyValue.diSize)); {ELSE} // An ugly replacement MemCpy FOR I:=0 TO diSize - 1 DO _Descr.pValue[I] := anyValue.pValue[i]; END_FOR {END_IF} // Otherwise, in case of failure maybe better set an empty value (overwrite the former data descriptor) ELSE THIS^._Descr.TypeClass := TYPE_CLASS.TYPE_NONE; THIS^._Descr.pValue := ADR(_Data); THIS^._Descr.diSize := 0; END_IF METHOD GET_Value : BOOL VAR_INPUT anyValue : ANY; END_VAR VAR I : DINT; END_VAR // We just have to serve the data, using the __System.AnyType structure received // Roughly we can say: IF anyValue.TypeClass = _Descr.TypeClass AND anyValue.pValue <> 0 // This should not be possible, already taken care of by Codesys (?) THEN {IF defined (pou:SysMem.SysMemCpy)} SysMem.SysMemCpy(anyValue.pValue, _DataType.pValue, TO_UDINT(MIN(anyValue.diSize, _Descr.diSize))); {ELSE} // An ugly replacement MemCpy FOR I:=0 TO MIN(anyValue.diSize -1, _Descr.diSize - 1) DO anyValue.pValue[I] := _Descr.pValue[I]; END_FOR {END_IF} // Just to make sure, that our string is terminated... IF anyValue.TypeClass = TYPE_CLASS.TYPE_STRING THEN anyValue.pValue[anyValue.diSize -1] := 0; END_IF GET_Value := TRUE; RETURN; END_IF // ... But can play more CASE anyValue.TypeClass OF TYPE_CLASS.TYPE_WSTRING : ; // Could do conversion TYPE_CLASS.TYPE_XSTRING : ; // Wow, I have to figure this out TYPE_CLASS.TYPE_PARAMS : ; // BTW, what is this, how to use? TYPE_CLASS.TYPE_ANYNUM : ; // ... END_CASE Be careful it was not tested. I'm sure can be done better, please feel free to comment 3. If you really want to do entries with variable size In a standard environment, it would be similar to the previous, except you dont have the container variable _Data, just use a pointer, practically _Descr.pValue At Initialize (SET_Value), you have to allocate the memory, would be easy with SysMem.SysMemAlloc - nowadays with SysMem.SysMemAllocData -, and you make sure to release it after use with SysMem.SysMemFreeData... SysMemAlloc was already hidden. The problem with this, that sooner or later your application will totally fragment the dynamic memory, and fail... So should look for some form of dynMaybe MemUtils.MemoryManager (I am not sure what is the status and the future of it). 4. You will end up by a LogEntry Factory ... 5. You could still have a look at this IEC Snippets BTW, Standard Codesys Logger is not a bad choice either. If you are really interested, I share some more code / library.
Last updated: 2025-03-09
Post by paulg on RasPi CAA Serial example - unexpected behavior during debug
CODESYS Forge
talk
(Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06
Post by dwpessoa on CNC Jumps G20 - SMC_NCInterpreter and long time to process
CODESYS Forge
talk
(Post)
I am studying and developing a Softmotion+CNC system for a machine that executes multiple pieces. The G code program is written by the machine operator and each cycle execute 1 piece. The programs are large, exceeding 1000 lines and using up to 8 axes (X, Y, Z, A, B, C, P and Q). The machine needs to run cyclically, executing N pieces (selected by the Operator)... so I tested it using Looping and counters (G36 G37 and G20) and it worked, but it takes a long time to process, and the more pieces I need, the longer the processing time and this is totally impracticable. I found this solution which was very good, and for a few cycles it works well, but for 99999 pieces of a program with 1000 lines, it doesn't work very well... Another solution I tested is to maintain the interpolator with an automatic restart, that is, I load the program without looping (without G20) and give it another start as soon as it finishes. This partially resolved it, but there is still a delay in processing SMC_NCInterpreter in each restart :(. Another solution I thought of is to manually create the SMC_GEOINFO structure and then reuse it, avoinding the Interpreter, but reading the documentation and checking the structure filled by standard blocks, I noticed that there doesn't seem to be a "JUMP" function in the structure! In other words, the SMC_NCInterpreter actually keeps copying and copying the program section for each jump (G20)... If I repeat a 10-line program 1000 times, I will have a structure with more than 10000 lines... possibly this is the cause of take so long to process. Has anyone ever had a problem like this? I believe the same thing happens with typical applications with manipulator robots using Codesys in continuous cycles, and I would like to know if there is any solution, or even if I am misinterpreting the G20 question in SMC_GEOINFO. Thanks!
Last updated: 2023-09-20
Post by mgabryel on Problems with CAN 2.0 comunication on Wago PLC (Codesys 3.5)
CODESYS Forge
talk
(Post)
Hello, I am trying to program CAN Bus comunication on WAGO PLC (more precisely on WAGO Touch Monitor model TP600). I am using for this purpose library "WagoAppCanLayer2" from Wago company. My IDE for programming this device is CODESYS V3.5 SP19 Patch 2 + (64-bit). My program is written in Structured text using function blocks from previously mentioned library. Here is code of this program: 1) Variables declarations: PROGRAM PLC_PRG VAR oOpenInterface : WagoAppCanLayer2.FbCanL2Open :=( udiBaudrate := 125000 ); xInterfaceIsOpen : BOOL; sInterfaceInfo : STRING; oReceive : WagoAppCanLayer2.FbCanRx29BitFrame :=( xBufferMode := FALSE, wCanId := 16#181 ); xRecv : BOOL; sReceiveInfo : STRING; oSend : WagoAppCanLayer2.FbCanTx29BitFrame :=( dwCanId := 16#100, //was 16#201 xRtrFrame := FALSE ); xSend : BOOL; sSendInfo : STRING; oCanDiag : WagoAppCanLayer2.FbCanErrorInfo; xRst : BOOL; aSendData : ARRAY [1..8] OF BYTE; bSendLen : BYTE; TON_0 : TON; TON_1 : TON; END_VAR 2) Program body: oOpenInterface( xEnable := NOT xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE ); sInterfaceInfo := oOpenInterface.oStatus.GetDescription(); xInterfaceIsOpen S= oOpenInterface.xValid AND NOT oOpenInterface.xError; oReceive( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xRxTrigger := xRecv ); sReceiveInfo := oReceive.oStatus.GetDescription(); IF NOT xRecv THEN IF oReceive.bRxNBytes > 0 THEN oReceive.aRxBuffer[1]; oReceive.aRxBuffer[2]; oReceive.aRxBuffer[3]; oReceive.aRxBuffer[4]; oReceive.aRxBuffer[5]; oReceive.aRxBuffer[6]; oReceive.aRxBuffer[7]; oReceive.aRxBuffer[8]; END_IF xRecv := TRUE; END_IF aSendData[1] := 224; aSendData[2] := 13; aSendData[3] := 14; aSendData[4] := 15; aSendData[5] := 222; aSendData[6] := 13; aSendData[7] := 14; aSendData[8] := 15; bSendLen := 8; TON_0(IN:= NOT TON_1.Q, PT:= T#2S , Q=>xSend, ET=> ); TON_1(IN:= TON_0.Q, PT:= T#2S , Q=>, ET=> ); oSend( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, aTxBuffer := aSendData, bTxNBytes := bSendLen, xTxTrigger := xSend ); sSendInfo := oSend.oStatus.GetDescription(); oCanDiag( xEnable := TRUE, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xTriggerResetCounter := xRst, xValid=> , xError=> , oStatus=> , wBusState=> , wBusDiag=> , uiRxOverflowsL2=> , uiTxOverflowsL2=> , uiRxOverflows=> , uiMsgTimeouts=> , uiBusOffs=> , uiBusWarnings=> ); Program first opens comunication on CAN 2 device and then periodically try send one CAN data frame. After starting program CAN 2 interface is properly open. The xSend variable is toggling with period 2s. When program sends data an "Tx overflow" error appears. When I am watching CAN_H line on DSub 9 socket i am not able to see proper CAN frames - see screenshot attached to this message. Could somebody help me determine what is wrong with this program. Best regards
Last updated: 2024-08-02
Post by george32 on CSV file and string manipulation.
CODESYS Forge
talk
(Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27
Post by patrik on Wish: CODESYSControl.cfg - again
CODESYS Forge
talk
(Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21
Post by eoahe on Problem Reading Registers via Modbus from non Codesys device
CODESYS Forge
talk
(Post)
Hey Guys :) I have the following Problem using Modbus via Codesys: I'm trying to implement a Modbus Device into my codesys project. The device is a Router from Teltonika (RUT956) and it can communicate via Modbus. Currently I'm trying to implement it into my codesys prject as a slave and I'm using my windows computer as master. As it is not a codesys device (the codesys application is not uploaded to device as it has its own software) I'm having problems requesting and reading registers from the router. I've set up my windows computer as Master and implemented the router as slave. When I go online on my master device it sais that it has established a connection to the slave (router)(So I'm thinking this could work as there is a connection?). The goal is to read the GPS (latitude and longitude) data and on the homepage of teltonika you can find the register address and number of registers (adress 143 for latitude and 145 for longitude; both have a number of two registers). I've found tutorials how to read specific registers via their register address with other modbus programs (like modbus-cli), but as my entire project is established in codesys I was hoping to read these specific registers via codesys so that I can show the GPS data on my dashboard. I've tried establishing slave channels but that hasn't been working. I tried read input register channels of the length 4 but it's not possible to define specific register addresses to read via codesys so that didn't work (I jsut get a slaves device failure) and I've also tried establishing 516 (total number of registers the router sends I think?) read inputregister channels but that has the samle failure... So i guess the problem I'm having is establishing slave channels to read these specific registers. Does anyone know how to tackle this problem and has maybe had the same problem? Or maybe someone knows a workaround? I'm quite new to codesys so maybe I'm also lacking expertise...
Last updated: 2025-03-01
Post by clarenced on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks
CODESYS Forge
talk
(Post)
Using codesys v3.5 SP21 Patch 1. We are using Visualization to display alarms. Other then the automatically created AlarmManagerTask, there is no code written to call AlarmStorage_Prg. Any ideas why we would be seeing this error in the log? The runtime actually shutdown. Not sure if that was caused by this error or not. 2025-08-03T02:45:35.444Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T03:48:15.294Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T04:38:11.557Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * 2025-08-03T04:38:11.576Z, 0x0000010f, 8, 1, 0, #### Exception: SysSemEnter - Semaphore deadlock detected - owner thread died [tid:726740] - system may be in an inconsistent state. 2025-08-03T04:38:11.576Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-08-03T04:38:11.576Z, 0x00000001, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-08-03T04:40:12.308Z, 0x00000001, 1, 0, 35, CODESYS Control shutdown... 2025-08-03T04:40:13.436Z, 0x00000071, 1, 0, 13, Webserver stopped 2025-08-03T04:40:13.437Z, 0x00000114, 2, 1, 0, !!!! Warning: task_signalhandler_exit [MainTask] lost cycles: 14809 2025-08-03T04:40:13.497Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IecVarAccess</cmp>, <id>0x00001007</id> <ver>3.5.3.64</ver> 2025-08-03T04:40:13.506Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>AlarmMgr</cmp>, <id>0x00001012</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.513Z, 0x00000071, 2, 0, 14, !!!! Warning: Unbalanced calls to WebServerRequestRunning/WebServerReleaseRunning 2025-08-03T04:40:13.513Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IECVisualization</cmp>, <id>0x0000100c</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:50:17.708Z, 0x00000001, 1, 0, 36, CODESYS Control shutdown done
Last updated: 2025-08-04
Post by gmau on Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired
CODESYS Forge
talk
(Post)
Hello, I am writing to You with the problem of Profinet communication in my Codesys V2.5 SP21 project working on Codesys Control RTE V3 x64 device. I have implemented multiple Profinet devices in the network, the Profinet itself is configured properly, based on the hardware and software parameters of the industrial PC (Windows 10 IoT). My Profinet network contains such Profinet devices as a robot, IO-Link master with some devices on it, IO modules, safety, vision sensor (the configuration is attached to this topic). Once every few hours, sometimes more often, sometimes not even once a day, the error show up at one, two or a few random modules at the same time, every one is the same: "Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired". The communication is then lost with that module, but it is up instantly. It is not such a problem when it comes to regular IOs, but with safety or rotation table, it causes errors and machine stops. I have tried multiple solution based on any forum suggestions, manuals, etc., but it is still happening. Mabye when I turned on the Watchdog for this communication, it is happening less times, but still, I could not turning up the Watchdog parameters at the expense of cycle time of the process. The same is with Send Clock, Reduction and DHT. I have one of the ethernet port on the PC configured with CmpEt1000Drv driver. The card itself is Intel Ethernet Connection I219-LM. These devices are connected to one EKI-2728-NI-A Profinet switch (it was changed from the standard non Profinet one, but still nothing has changed). As I said ealier, I am attaching all the configurations for each device and the communication itself - if any of You had the same problems or have any ideas what could be the cause, I would be much gratefull for any help. For now I am out of ideas, if You have any additional question, please ask. Sincerely, PF
Last updated: 2025-09-04
Post by kurtk on SysProcess Execute Command unable to run commands with special characters
CODESYS Forge
talk
(Post)
Thank you for this additional information. Could you please provide the references to the official documentation where you found this information ? I got as far as: Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll devoid of references of where the CodesysContol.cfg file was located or of the need to run codesys as root I incrementally located bits of information with perplexity searches but remained mired at error 25 ERR_NO_ACCESS I am curious whether root access is MANDATORY to run SysProcessExecuteCommand (- and/or any other SysProcess functions) or if a more access-constrained User=quasiroot could suffice without the security concerns ? Apparently codesys runs fine without User=root for almost everything... That raises the question: What IS the default codesys user ? I notice in the prototypes: VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR whenever I attempt to build this Codesys v3.5 SP2 whines that "cannot convert type REFERENCE TO STRING to STRING" don't remember the exact message... Apparently this happens whenever a fixed-length string is involved. if I get rid of (255) and just set the string := ' '; that is sufficient to make the compiler happy. Is this a recently enforced constraint ? Why does this compile for you and not for me ? There are references to functions / utilities which are used/needed to massage the string references - but I see no specific details... I also notice you specify: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. I don't comprehend why all of the dependent libraries are not automatically referenced, added ? I don't recall seeing anywhere but here that SysProcessImplementation must be included... It just seems odd that the default is to exclude essential libraries, or require alchemical conjuring to assemble all the ingredients for gnat soup ;-) Thanks a lot... I'm still a codesys newby getting my wheels on - or sometimes just partially on
Last updated: 2025-09-12
Post by rkohser on Scripted Git clone / checkout being blocked by "Project Environment" popup
CODESYS Forge
talk
(Post)
Hi, I am trying to build a CI/CD pipeline around our codesys projects. The only entry point if the git url and branch, as we do not put our project file under source control, so we needed to find a way to git clone from the python scripting engine. This is currently how we do this : system.commands["Git", "Clone"].execute( "ProjectLocation=" + project_dir, "ProjectName=" + project_file_name, "RemoteUrl=" + project_git_remote_url, "GitProjectStoragePath=" + project_git_local_dir, ) system.commands["Git", "Checkout", "Branch"].execute( "PrimaryProjectHandle=0", "BranchName=origin/" + project_git_branch ) This works fine, except that, depending on the environment and the project, the "Project Environment" popup gets displayed to suggest for some updates, and waits for a user interaction, even with the "--noUI" flag injected as parameter. I investigated the VersionUpdateFlags, but the problem is that the git clone is an atomic operation that clones and directly opens the generated project without the possibility to inject any updateFlags argument (only used in the ScripProjects.open() function. I also tried to simulate some keyboard events acknowledge the window from script but I did not find the right location for the SendKeys statement, I think before the git clone call is too early and after is too late. So I am wondering if there would be some other way to do that. Is there some more proper scripting api for the git add on ? Is there a global configuration of the VersionUpdateFlags that would allow the popup to be disabled outside from any project context ? Is there some way to automatically acknowledge this kind of messages in a "--noUI" mode ? What do you suggest ? Thanks for your help, Roland Edit : I managed to solve my problem by following these steps in my pipeline : - create a template of a project and opt file preconfigured not to open the popup - open this project - initialize an empty git repo - add the remote, fetch and checkout the needed branch -> no popup is displayed, hourra Edit2 : The initial question was raised on a CODESYS V3.5 SP18 Patch 2 profile. Since CODESYS 3.5.19.30 a scripting API is available for Codesys Git that allows cloning a project with the support of VersionUpdateFlags https://content.helpme-codesys.com/en/CODESYS%20Git/_git_using_scripting.html
Last updated: 2024-01-19
Post by dandyk on Dynamic Images
CODESYS Forge
talk
(Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06
Post by axberry on CODESYS Control for Raspberry Pi 5 - "Hardware version or firmware version not supported" on Rev 1.1, persists across multiple runtime versions and OS images
CODESYS Forge
talk
(Post)
Hi, I'm trying to run CODESYS Control for Raspberry Pi SL on a Raspberry Pi 5, and the runtime consistently fails to start with the following error when launched manually: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) Hardware: Raspberry Pi 5 Model B Rev 1.1 Revision code: d04171 CPU: aarch64, BCM2712 Serial number is correctly exposed via /proc/cpuinfo and /proc/device-tree/serial-number /proc/device-tree/model correctly reports "Raspberry Pi 5 Model B" What I've tried (all resulting in the same error): CODESYS Control for Raspberry Pi SL 4.11.0.0 (SDK 3.5.19.61) — the version that introduced Pi 5 support CODESYS Control for Raspberry Pi SL 4.21.0.0 (SDK 3.5.22.20) — latest available Raspberry Pi OS Bookworm (64-bit) with kernel 6.12.93+rpt-rpi-2712 (June 2026 build) Fresh install on Raspberry Pi OS Bookworm (64-bit) with an older image from November 24, 2025 — same error, ruling out a kernel-version regression Bootloader/EEPROM confirmed up to date (rpi-eeprom-update reports "up to date") Clean purge and reinstall of the codesyscontrol package each time (verified via dpkg -l, no leftover files) Verified /etc/codesyscontrol/3S.dat correctly symlinks to /etc/codesyscontrol/3S_aarch64.dat The service starts (systemctl status briefly shows active (running) with a real PID under /opt/codesys/bin/codesyscontrol.bin), but crashes shortly after and the process disappears — port 11740 never opens. Since this happens identically across two different runtime versions and two different OS images (5+ months apart), it doesn't seem to be a kernel/firmware timing issue. Could this be specific to the Rev 1.1 board revision, or is there a known issue with the hardware detection logic in the SL runtime that I should be aware of? Happy to provide full debug logs (-d flag output) or journalctl output if useful. Thanks in advance!
Last updated: 2026-08-10
Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade()
CODESYS Forge
talk
(Post)
Follow-up: working workaround found (routing TLS outside CODESYS) For anyone finding this thread later with the same problem (a third-party device presenting a self-signed and/or expired certificate that ICertificateVerifier/udiVerificationMode won't let you connect through) - we never got a working fix within NBS itself, but found a practical workaround worth sharing. Approach: run a local TLS-terminating proxy on the same host as the CODESYS runtime, and have CODESYS talk plain, unencrypted TCP to it instead of connecting to the remote device directly over TLS: CODESYS --plain TCP--> 127.0.0.1:<port> --stunnel/TLS--> <remote device>:<port> We used stunnel (client mode), with certificate verification explicitly disabled at that layer (verifyChain = no, verifyPeer = no) - a simple, well-documented one-line option, unlike anything we could get working inside NBS. Running it as a systemd service with Restart=always means it survives reboots and recovers automatically if the proxy or the remote device drops. On the CODESYS side, this required no changes beyond pointing TCP_Client at 127.0.0.1 instead of the device's real IP, and removing the TLSContext/ICertificateVerifier code entirely - the rest of our application-layer logic (framing, checksums, etc.) was completely unaffected, since none of that ever depended on where the TLS termination happened. Confirmed working end-to-end against a real device with an expired self-signed certificate, running on CODESYS Control for Raspberry Pi SL (Linux). We haven't yet set this up on Windows - stunnel does have Windows builds available, so the same general approach should be possible there too, but that combination isn't tested or confirmed by us at this point. Caveat: this only makes sense when the proxy and the CODESYS runtime are on the same trusted host (in our case, both on the same Raspberry Pi) - don't expose the proxy's plaintext side on a reachable network interface, since that would create an unauthenticated plaintext path to the device. The original question - whether there's a supported way to override an ERR_CERT_HAS_EXPIRED/self-signed rejection from within NBS's own TLSContext/ICertificateVerifier - remains open as far as we know. Still happy to hear from anyone who's solved that particular piece, since the workaround above is a practical detour rather than an actual answer to the original question.
Last updated: 2026-08-06
Post by paulpotat on cm4 runtime problem
CODESYS Forge
talk
(Post)
Hello, We are having the same kind of problem again with the last CM4 we received : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) Hardware Version $ cat /proc/cpuinfo processor : 0 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 processor : 1 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 processor : 2 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 processor : 3 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 Hardware : BCM2711 Revision : a03141 Serial : 1000000097594db7 Model : Raspberry Pi Compute Module 4 Rev 1.1 Kernel Version $ uname -a Linux cmr-pv2-1t00-0001 6.12.25-rt9-v7l #1 SMP PREEMPT_RT Thu Sep 25 11:53:00 CEST 2025 armv7l GNU/Linux OS Version $ cat /etc/os-release PRETTY_NAME="Raspbian GNU/Linux 12 (bookworm)" NAME="Raspbian GNU/Linux" VERSION_ID="12" VERSION="12 (bookworm)" VERSION_CODENAME=bookworm ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs" CodeSys runtime 4.13.0.0 So far we tested runtime versions up to 4.18.0.0, here are the results : * 4.13.0.0 --> Not working ❌ * 4.14.0.0 --> Not working ❌ * 4.15.0.0 --> Not working ❌ * 4.16.0.0 --> Not working ❌ * 4.17.0.0 --> Working ✅ * 4.18.0.0 --> Working ✅ There is nothing in the 4.17.0.0 release note that mentions that, so I'm not sure what to think about this. Is this a known problem within the CodeSys development team ? If yes, how do you follow CM4 hardware evolutions ? Is there a way of making this work without having to update the runtime version ? We have several products working with the 4.13.0.0 runtime and we would like to avoid having to update them all. BR
Last updated: 2026-02-02
Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade()
CODESYS Forge
talk
(Post)
Setup: Net Base Services (NBS), TCP_Client + TLSContext, ePurpose := CLIENT_SIDE, connecting to a third-party embedded device (Velux KLF200 home automation gateway) whose factory-installed TLS certificate expired on 2026-07-12 and has no user-facing renewal path. Tested on both CODESYS Control for Raspberry Pi SL (3.5.19.0) and CODESYS Control Win V3 x64, with identical results on both. Goal: Accept the peer's expired certificate via a custom ICertificateVerifier implementation, since the certificate itself can never be replaced. Implementation: FUNCTION_BLOCK FB_MyCertVerifier IMPLEMENTS NBS.ICertificateVerifier VAR udiCallCount : UDINT; aeCurStateLog : ARRAY[0..9] OF NBS.RTS_IEC_RESULT; END_VAR METHOD VerifyCertificate : UDINT VAR_INPUT hCert : NBS.RTS_IEC_HANDLE; eCurState : NBS.RTS_IEC_RESULT; END_VAR IF udiCallCount < 10 THEN aeCurStateLog[udiCallCount] := eCurState; END_IF udiCallCount := udiCallCount + 1; VerifyCertificate := 0; // also tried: VerifyCertificate := eCurState; Wired in via tlsContext.itfCertVerifer := certVerifier at declaration time, alongside itfTLSContext := tlsContext set at TCP_Client's own declaration (per an earlier forum thread here on ensuring inline start-values on FB-typed variables are actually honored when nested one level deep - that fix was needed and worked correctly for getting the handshake to start at all). Observed: - VerifyCertificate is confirmed called exactly once per connection attempt (via the call counter above). - eCurState passed in = 0x709 = ERR_CERT_HAS_EXPIRED - correctly reflecting the actual state of the peer's certificate. - Packet capture confirms the full TLS 1.2 handshake completes correctly at the wire level: ClientHello -> ServerHello -> Certificate -> ServerKeyExchange -> ServerHelloDone -> our ClientKeyExchange/ChangeCipherSpec/Finished -> server's ChangeCipherSpec/Finished. Both sides successfully complete the cryptographic handshake. - Despite this, TCP_Client.Upgrade() subsequently returns NBS.ERROR.CONNECTION_ERROR, and the connection is torn down with a plain TCP FIN (not a TLS alert) roughly 7-8ms after our side ACKs the server's Finished message. - TCP_Client.eErrorID (inherited from LCon) remains NO_ERROR throughout - the failure is only visible via Upgrade()'s return value. - Returning 0 (ERR_OK/ERR_CERT_OK - confirmed via the CmpErrors2 Interfaces documentation that these are literally the same value) makes no difference. - Echoing eCurState back unchanged (on the theory that this callback might work like mbedTLS's native verify callback, where the incoming state is a flags value to be cleared/modified and returned, rather than paired with a separate fixed "accept" sentinel) also makes no difference. - Identical result across udiVerificationMode := 0, 1, and 2. - Importing the peer's certificate into the runtime's trusted certificate store via cert-import trusted makes no difference either. - With itfCertVerifer left at its default (no custom verifier) and udiVerificationMode := 2, the underlying engine sends its own fatal TLS alert (handshake_failure) immediately after receiving the peer's Certificate message - suggesting built-in validation may reject at the record layer independent of whether a custom verifier is even present. Questions: 1. Is there an additional step required for a custom ICertificateVerifier to actually override an ERR_CERT_HAS_EXPIRED (or more generally, any ERR_CERT_*) rejection, or is certificate validation enforced unconditionally for a CLIENT_SIDE TLSContext regardless of what the verifier returns? 2. Is 0/ERR_OK genuinely the correct "accept" return value for VerifyCertificate, or does it expect something else (a specific bit pattern, a different constant, a value that must be computed from hCert itself)? 3. Is there a supported way to connect to a peer presenting a certificate that is both self-signed and expired, short of the peer issuing a new certificate? Happy to share the full packet captures or additional test combinations if useful. Also worth noting for anyone finding this thread later: a maintained Node-RED library for this same device (node-red-contrib-velux-klf200, forked to handle this exact expired-certificate situation) solves it by disabling built-in TLS validation entirely (rejectUnauthorized: false) and doing fingerprint-based pinning by hand after the handshake completes, rather than relying on a validation callback - which may be the more realistic approach here too if ICertificateVerifier genuinely can't override this class of rejection. Thanks in advance /Jørgen Disclosure: most of the CODESYS code and this investigation was developed with the help of Claude (Anthropic's AI assistant) - the state machine design, SLIP/checksum implementation, and debugging methodology (including the packet capture analysis) were worked through in an extended back-and-forth with it. Posting here because we've run out of self-serviceable options and this now looks like it needs input from someone with visibility into NBS's actual implementation.
Last updated: 2026-07-26
Post by brouwyka on JSONByteArrayWriter string result incorrect order
CODESYS Forge
talk
(Post)
Hello everybody! We are currently working on implementing a call to an API that tracks data sent to it through a JSON body. Versions: CODESYS V3.5 SP19 Patch 7 using IIOT Libraries SL license, specifically JSON Utilities SL version 1.13.0.0. For simplicity, let's say we want to construct the following JSON body for our request (simplified to just 1 key-value pair in each of the array objects to keep things shorter, but we'd have multiple fields in each in reality): { "id": "machine_1", "readings": [ { "temp_mid": 153.8 }, { "temp_mid": 98.3 } ], "status": "RUNNING" } However, our "readings" data is added over time, not in creation, so calls to the builder would be somewhat out of order. In a simplified manner, our calls would look like this: jsonBuilder(pJsonData := JsonData, diRootObj => rootJsonIndex); // rootJsonIndex = 0. // Set "id" at root JSON object. wsValue := "machine_1"; jsonBuilder.SetKeyWithValue("id", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 1, VALUE: diParentIndex = 1 & diIndex = 2. // ... Time passes, we get our first reading to add ... // The "readings" array does not exist yet, so we make it first at root JSON object before adding our first reading. readingsJsonArrayIndex := jsonBuilder.SetKeyWithArray("readings", diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 3, VALUE: diParentIndex = 3 & diIndex = 4. // Then add the first reading, for which we first have to make an object. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 5. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the first object in the array. rValue := 153.8; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := readingsJsonArrayObjectIndex); // JSONData KEY: diParentIndex = 5 & diIndex = 6, VALUE: diParentIndex = 6 & diIndex = 7. // ... Time passes, we want to add another root-JSON-level field ... // Set "status" at root JSON object. wsValue := "RUNNING"; jsonBuilder.SetKeyWithValue("status", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 8, VALUE: diParentIndex = 8 & diIndex = 9. // ... Time passes, we want to add a second reading ... // "readings" array exists, so add the second reading, but first we have to make another object. // NOTE the re-use of the earlier stored `readingsJsonArrayIndex`, so we add the new object to that previously created array. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 10. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the SECOND(, new) object in the array. rValue := 98.3; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 10 & diIndex = 11, VALUE: diParentIndex = 11 & diIndex = 12. // ... Finally, we want to send to the API, so we must convert the builder to data the client accepts as a body ... xTestWriteToJsonArray := TRUE; jsonArrayWriter( xExecute := xTestWriteToJsonArray, pwData := ADR(jsonDataString), udiSize := SIZEOF(jsonDataString), jsonData := JsonData^ ); IF jsonArrayWriter.xDone THEN // The writer was successful, the `jsonDataString` VAR should now contain a WString copy of the JSON object from the builder. xTestWriteToJsonArray := FALSE; END_IF We see that the JsonData STRUCT is correctly organised (in terms of the diParentIndex & diIndex set by it for each JsonElement) as we expect, as outlined in my comments in the simplified code above. However, as soon as we pass it to the jsonArrayWriter (which is a JSON.JSONByteArrayWriter), the resulting jsonDataString does not match our expectations, instead coming out like this: { "id": "machine_1", "readings": [ { "temp_mid": 153.8 } ] } { "temp_mid": 98.3 } "status": "RUNNING" The behaviour of the JSONByteArrayWriter thus seems to be the problem here. It does not seem to correctly process the children of JsonElements that are ARRAYs when additions to them are done broken up by additions to the lower level JSON OBJECT they are a part of. We have confirmed this by changing the order of the calls in our example to add both readings before adding the "status", in which case we get our expected outcome. However, in reality this is not possible for us - additions to any of the JSON's objects, arrays or array objects may happen at any time after other fields elsewhere in the JSON have been added. Does anyone know a way around this, a fix, or knows a solution we simply have not found? This same phenomenon was also noted on this forum by user @ryusoup at the end of 2023 (https://forge.codesys.com/forge/talk/Engineering/thread/c45929e2f1/#e27f) and user @mtho in early 2024 (https://forge.codesys.com/forge/talk/Engineering/thread/cd1bb450db/#1292) but both topics received no activity beyond both users' opening posts. Looking through the release notes of all the versions of the JSON Utilities SL library, I also did not see any remarks on resolutions of bugs in this vain. Thanks in advance for the assistance!
Last updated: 2026-06-10