Post by e13740e on Сalling the context menu from the keyboard
CODESYS Forge
talk
(Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05
Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by mp9876 on Device logon problem following fresh install
CODESYS Forge
talk
(Post)
All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. ‘Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh install: YES then: Initially went with Administrator twice (user & password) but it did not like it. No device is responding to …: Continued by setting a new user Pressed OK and obtained the following message: Stopped and Restarted PLC at that point: Obtained the following: Attempted to login a 2nd time without success. Then I scanned the network to see if matching device can be detected: Only way to get it detected was to remove the tick in the ‘Hide non-matching devices…’ Attempted a WINK but got a return like this one: REFRESH either @ Users and Groups or @ Access Rights returns: Then created user ‘mp’ at Project level ang logged in: Understandably device user mp9876 was not valid for the Project. Device information A few questions comes to my mind following these connection attempts: 1- Gateway not configured properly message pops out because of a non-compatible device ? 2- Why would the device not be compatible ? 3- Any way to make the device compatible ? 4- Any ideas on how to get this connectivity problem to the device solved ?
Last updated: 2024-03-17
Post by yannickasselin on Lenze i950 Servo and WAGO PFC200
CODESYS Forge
talk
(Post)
I don't have time to go through the whole manual but as I said earlier, the servo drive does not support any of the modes needed for SoftMotion Light to work. If you want to use the full SoftMotion, you could use SMC_Homing function block to do the homing. This function block does not use the Homing Mode. It still uses the CSP mode and does the logic in Codesys runtime instead of in the servo drive. Read the documentation about it to see if it fits your needs. But if your controller only supports SoftMotion Light, I am afraid you will not be able to use the i950. I do a lot of motion stuff with different servo brands. Some support all the modes needed for SoftMotion Light and some don't. You really need to make sure the modes are supported before choosing a brand over another. I tend not to use brand specific controllers in order not to be limited by their supported features. I usually choose a PC (Linux or Windows) and install the Codesys runtime and licences myself. This is the most flexible way to use Codesys in my opinion. Depending on how many axes are needed in your project, a full SoftMotion license may not be more expensive than SoftMotion Light because SoftMotion is available as Application based license whereas SoftMotion Light is not. But of course, SoftMotion is harder on the CPU than SoftMotion Light.
Last updated: 3 days ago
Post by deeps on wed visu im IFM display CR1077
CODESYS Forge
talk
(Post)
Ich habe ein IFM cr1077 Display. Ich würde gerne die B&R Kartenansicht auf der IFM Visualisierung anzeigen. Dazu habe ich das Webbrowser-Element von Coedsys verwendet. Ich konnte sehen, dass IFM im Internet-Webbrowser gut funktioniert, aber das IFM-Gerät zeigt einen weißen Bildschirm und friert ein. Ich denke, es gibt ein Problem mit IFM, das den Webbrowser anzeigt. Verstehe ich die Webvisualisierung richtig oder mache ich hier einen Fehler?
Last updated: 2023-08-18
Post by gerdkoch on Dynamic I/Os Mapping
CODESYS Forge
talk
(Post)
Hi, I assume that you have a Pfc200 G2 or something and work with the original WAGO runtime. Then I would recommend the WagoSysDynamicIoMapping. Here in the example projects there is a PDF file for the library: https://downloadcenter.wago.com/learning-material/details/ll0w3pmdunzvem83g1 There is a global functional component in a GVL of the library. I think it's called DynKbusIoManager or something. The active terminals are registered there. Then there are filter Fb's for e.g. the first clamp with a specific article number. Everything is in the PDF.
Last updated: 2023-08-18
Post by ihatemaryfisher on Sorting array of any-sized structure
CODESYS Forge
talk
(Post)
With that I could make an array of varying size, but would still have to define the array type in the function's declaration VAR_IN_OUT stArray: array [*..*] of <pre-defined data type> END_VAR I wanted a function that could take an array of any type (e.g., a structured VAR) as an input. That way I could call it in multiple POUs to handle different arrays structures.
Last updated: 2023-08-18
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.
Last updated: 2023-08-23
Post by kreisfilho on Stop raspberry from executing a plc program
CODESYS Forge
talk
(Post)
Hi guys, Can someone inform where in a raspberry pi are stored the codesys programs? I´ve been training the use of a RPI as PLC, which works pretty well, however while both the RPI and PC (running codesys) remain connected to the same network. The question is: how to run the codesys program downloaded to the RPI as a stand alone device (disconnected from the PC)? Thanks! Kreis
Last updated: 2023-08-23
Post by e60newbie on NETVAR_UDP
CODESYS Forge
talk
(Post)
Hallo Forums Gemeinde, hat jemand von euch eine Idde ob und wie es möglich sein könnte die Einstellungen was für die Netzwerk variablen Liste nötig sind, also Broadcast IP, Port usw., über die Application einzustellen? Ich müsste je nach Projekt immer die IP anpassen, da auf den Anlagen die Software Identisch bleibt, wäre es für mich viel einfache diese Einstellungen über den Code einzustellen. Wenn man so im Forum sucht gibt es nicht viel was NetVar angeht... Grüße Andy
Last updated: 2023-08-29
Post by rossanoparis on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
Thank you @eschwellinger Even tough I think the content of the link you provided is a bit messy. To bind OPCUA server to a specific adapter, I should have had insert the following section. [CmpOPCUA] NetworkAdapter=eth0 But it doesn't work, I had to insert the following section instead to get the right configuration. [CmpOPCUAServer] NetworkAdapter=eth0 Regards Rossano
Last updated: 2023-08-29
Post by ellcap on Symbol Configuration, I'm doing it wrong
CODESYS Forge
talk
(Post)
if you're here because you are making the same mistake as me, I just resolved it. I mistakenly thought I didn't need to write the word attribute in the column labeled attribute. changed this 'symbol' := 'read' to this attribute 'symbol' := 'read' The last two in this clip are still wrong: I recongize this is probably a big "duh". That's ok. I like to fail out loud in hopes it helps someone else from looking silly.
Last updated: 2023-08-31
Post by dasch on Webvisu auf Iphones
CODESYS Forge
talk
(Post)
Moin, ich arbeite an einer Visualisierung einer Fernbedienung, die auf mobilen Geräten laufen soll. Bei Iphones ist uns die Eigenheit aufgefallen, dass bei langem druck auf einen Button, die gesamte Seite markiert wird und dann kopiert werden kann. Manchmal popt auch die kleine Lupe auf, die einem helfen soll den Courser genauer zu platzieren. Weiß jemand ob man dieses Verhalten vielleicht durch zusätzliche Einträge in der webvisu.htm unterdrücken kann? Gruß, Daniel
Last updated: 2023-09-04
Post by dasch on eCockpit - unable to start simulation
CODESYS Forge
talk
(Post)
This is a known bug in e!Cockpit. See Release notes of V 1.11: 1 e!Cockpit Release Version 1.11 (2022-07) ATTENTION: If a library that uses asynchronous tasks (e.g. WagoAppConfigTool, WagoAppCloud or function modules such as Dali-Master) is dragged into the project, the simulation cannot be started. It is already sufficient to add the library to the project (an FB does not even have to be instantiated). I guess you are using one of these libraries/modules in your project. We e.G. often use PWM modules, these are also affected.
Last updated: 2023-09-05
Post by e60newbie on EVL/EVC auf IFM CR711S
CODESYS Forge
talk
(Post)
Hallo, wir sind etwas Ratlos mit der Handhabung der EVL/EVCs in Verbindung mit IFM CR7xxs Steuerungen. Uns ist aufgefallen, bzw. schon mehrfach passiert, dass ein Programmierer ein Projekt fertig stellt, dieses auf Freigegeben stellt und abschließt. Wenn ein zweiter Programmierer das Projekt öffnet und sich in die Steuerung einloggen möchte ist dies nicht möglich ohne Download. Es wird dann immer angezeigt, dass sich die EVC geändert haben obwohl im Programm nichts verändert wurde. Gibt es eine Einstellung was wir eventuell falsch habe? Wir kennen das so nicht von anderen Sicherheitssteuerungen. Grüße
Last updated: 2023-09-06
Post by ernesto881124 on ernesto881124
CODESYS Forge
talk
(Post)
Hello good morning everyone I would like to ask a question, is it possible to directly connect a device that only contains modbus RTU communication through an R-45 connector, directly to the PC? Or would you need an intermediate device to achieve communication? It would be of great help to me because I cannot achieve communication between the Codesys simulator plc and a Fuji Frenic mini VFD, please help me if anyone has had the same experience. Thank you so much
Last updated: 2023-09-13
Post by albertisa on GPIO Konfiguration auf SK-AM64B
CODESYS Forge
talk
(Post)
Hallo, seit einigen Tagen versuche ich erfolglos eine Ansteuerung der GPIOs des SK-AM64B Entwicklungsboards (Texas Instruments) über Codesys zu bewerkstelligen. Bei dem Versuch GPIOs anzusteuern, ohne die devdesc.xml bzw. den iodriver anzupassen, wird mir von Codesys die Fehlermeldung "Bus läuft nicht" (siehe Screenshot) angezeigt. Welche Vorgehensweise wird zur Konfiguration der IO empfohlen? Ist eine Anpassung der devdesc.xml und des IOdrivers notwendig? Wie wird am besten bei der Anpassung der genannten Dateien vorgegangen? Folgende Dokumentation ist mir bekannt, hat mir aber noch nicht weitergeholfen: https://forge.codesys.com/drv/io-drivers/doc/Generic/
Last updated: 2023-09-19
Post by jeffgamsby on Accessing ModbusTCP addresses from python
CODESYS Forge
talk
(Post)
Hi, I am new to modbusTCP and I am trying to access Input registers from codesys (3.5.SP13). The offset is 16#0000 and I am trying to access Channel 1[24] %IW24 to pull analog values. I am using pyModbusTCP and I need to supply a modbus address and the number of registers to read. What does 16#0000 mean in terms of the actual offset, how do I translate this number plus the channel to access this info via python? Any help would be appreciated, thank you.
Last updated: 2023-09-20
Post by timvh on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent
CODESYS Forge
talk
(Post)
I'm not really sure what you are trying to do, but maybe you are referring to using the CmpCharDevice library? When you "open" the connection to a device, you can pass flags. What helped me is to set the non-blocking flag. I'm not sure if this is what you are referring to, but maybe it helps: dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice := CmpCharDevice.CDOpen(szFilename, dFlags, Result);
Last updated: 2023-09-20
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
Thanks, I will check the PLC Log when the PLC is connected again. I will update my findings here. Since I don't have access to the Linux Panel PC at the moment, I tested inside my development VM with the same Linux OS. I have no issues or delays connecting to the WebVisu using my Linux VM. Two main differences: 1. My host Computer has a faster processor compared to the panel PC. 2. There are no devices connected in my dev environment. I will continue testing when I have connection to the panel PC.
Last updated: 2023-09-23
Post by docker on Canopen connection. Unknown node id.
CODESYS Forge
talk
(Post)
hi, i am currently trying to adapt an i/o device for a project. the node id is unknown and there is no eds file available. no data is being emitted from the device as a giveaway, the baudrate is known but useless without the node id. is there an sdo request available to determine the id? i cannot get the device to leave pre op status even with a global nmt request. please help. no hair left.
Last updated: 2023-09-25
Post by timvh on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
What maybe helps is the Visu Dialog ST demo project: https://store.codesys.com/en/visu-dialog-st.html This has an application IECOpenDialog where dialogs are opened using the VU.FbOpenDialogExtended function blocks. The fbOpenConfigurationDialog call has a reference (interface) to the "close listener" FB of which it's method is automatically called when the dialog is closed. This way you can create specific function blocks for each dialog when it is closed and do what you want with the data that might have been changed.
Last updated: 2023-09-28
Post by damian177 on Codesys and SMS in RPi
CODESYS Forge
talk
(Post)
Hi, I try use IIoT library to send and receive SMS by Raspbery PI and Codesys. I installed IIoT package and added the SMS library, But something is wrong, when I init communication it doesn't work, When I sniffer my communication (AT commands) beetwen RS232 RaspberryPi and my GSM modem I have only below commands: AT+CMEE=1 OK AT+CPIN? +CPIN: READY Anyone have idea what can be wrong ?
Last updated: 2023-09-28
Post by chris12345 on IO-Link Lizenz
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite mich momentan in das Thema IO-Link ein. Benutze einen Revolution Pi, IO-Link Master (AL1333 IFM), Sensor (OGD500 IFM) und ein IO-Link I/O Modul (AL2205 IFM). EDS-Dateien und IODD Dateien über das Geräte-Repro eingebunden. Bekomme jetzt folgenden Fehler:- Die Lizenz fehlt oder ist ungültig. Die SPS läuft im Demo-Modus. Welche Lizenz wird benötigt, um IO-Link fähigen Sensoren meinen IO-Link Master hinzuzufügen? Benutze die Codesys V3.5 SP19. Gruß Chris PS: Anbei das Bild
Last updated: 2023-10-09