ready to elevate your shopping experience with Temu's incredible offers! Use our exclusive Temu coupon code $100 off [acq794628] for existing customers or for new users to enjoy massive savings on your next purchase. Temu: Your Gateway to Unbeatable Deals Temu has taken the e-commerce world by storm, offering a vast array of products at jaw-dropping prices. With free shipping to 67 countries and lightning-fast delivery, it's no wonder Temu has become a go-to destination for savvy shoppers. . But the savings don't stop there – let's explore how you can maximize your discounts with our Temu coupon $100 off for existing customers! Exclusive Temu Coupon Codes for Maximum Savings Here's a quick rundown of our top Temu coupon codes: • acq794628: Temu coupon code $100 off for new users • acq794628: Temu coupon $100 off for customers • acq794628: Temu $100 extra off (Temu 100$ coupon code) • acq794628: $100 discount for new users (100 off Temu coupon) • acq794628: $100 coupon for existing and new users (Temu coupon code 100 off) Why Choose Temu? Before we dive deeper into the Temu $100 coupon bundle, let's look at what makes Temu stand out: 1. Vast product selection 2. Unbeatable prices 3. Fast and free shipping 4. User-friendly platform 5. Regular promotions and discounts How to Use Your Temu Coupon Code $100 Off Using your Temu coupon code $100 off is a breeze. Here's a step-by-step guide to help you make the most of your savings: 1. Browse Temu's extensive catalog 2. Add items to your cart 3. Proceed to checkout 4. Enter your Temu coupon code $100 off in the designated field 5. Watch your total drop by $100! Tips for Maximizing Your Savings To get the most bang for your buck,. consider these strategies: 1. Combine your Temu coupon $100 off with ongoing sales 2. Look for bundle deals to increase your savings 3. Check Temu's daily deals for additional discounts 4. Sign up for Temu's newsletter to stay informed about upcoming promotions Temu Coupon $100 Off: Frequently Asked Questions You might be wondering about the details of these incredible offers. Let's address some common questions: Is the Temu $100 off coupon legit? Absolutely! The Temu 100 off coupon is legit and has been verified by countless happy customers. You can shop with confidence knowing that your Temu coupon code $100 off will be honored at checkout. Can I use the Temu coupon $100 off for existing customers on my first order? While the Temu coupon $100 off for existing customers is designed for repeat shoppers, new users can take advantage of the Temu coupon code $100 off for new users. Both offers provide the same great savings! How often can I use a Temu coupon $100 off? Typically, these coupons are one-time use per account. However, Temu frequently releases new promotions, so keep an eye out for fresh opportunities to save! Explore Temu's Best Deals with Your $100 Off Coupon Now that you're armed with your Temu coupon code $100 off, let's look at some popular categories where you can apply your savings: • Electronics • Fashion • Home & Garden • Beauty & Personal Care • Sports & Outdoors Hot Deals Alert: Temu Coupon Codes Don't miss out on these amazing offers: • acq794628: Temu coupon $100 off for existing customers free shipping • acq794628: Temu coupon $100 off for new users • acq794628: Temu coupon codes 100 off • acq794628: Temu coupon $100 off code • acq794628: Temu coupon $100 off first-time user Make the Most of Your Temu Shopping Experience As you explore Temu's vast catalog with your Temu coupon $100 off in hand, keep these tips in mind: 1. Read product reviews from other customers 2. Check sizing charts for clothing and shoes 3. Compare similar items to find the best value 4. Take advantage of Temu's customer service for any questions The Temu Difference What sets Temu apart from other e-commerce platforms? It's not just about the Temu $100 coupon bundle – it's the overall shopping experience. With a user-friendly interface, a wide range of products, and unbeatable prices, Temu is revolutionizing online shopping. I've been using Temu for months now, and I can confidently say that the savings are real. Whether you're a new user looking to score a great deal with a Temu coupon code $100 off first order or an existing customer ready to use your Temu coupon $100 off for existing customers first order, you're in for a treat. Conclusion: Shop Smart with Temu In today's economy, finding ways to save money without sacrificing quality is crucial. That's why I'm thrilled to share these Temu coupon $100 off opportunities with you. Whether you're shopping for yourself or looking for the perfect gift, Temu has you covered. Remember, the key to maximizing your savings is to stay informed about the latest promotions. Bookmark this page and check back regularly for updates on Temu coupon codes and deals. And don't forget – your Temu coupon code $100 off [acq794628] for existing customers is waiting to be used! Happy shopping, and enjoy your incredible savings with Temu! .
Last updated: 2024-10-26
Post by fukre on Temu Coupon Code ☛{" acq794628."}: |Get "$100 off" + 30% Discount|
CODESYS Forge
talk
(Post)
Ready to elevate your shopping experience with Temu's incredible offers! Use our exclusive Temu coupon code $100 off [acq794628] for existing customers or for new users to enjoy massive savings on your next purchase. Temu: Your Gateway to Unbeatable Deals Temu has taken the e-commerce world by storm, offering a vast array of products at jaw-dropping prices. With free shipping to 67 countries and lightning-fast delivery, it's no wonder Temu has become a go-to destination for savvy shoppers. . But the savings don't stop there – let's explore how you can maximize your discounts with our Temu coupon $100 off for existing customers! Exclusive Temu Coupon Codes for Maximum Savings Here's a quick rundown of our top Temu coupon codes: • acq794628: Temu coupon code $100 off for new users • acq794628: Temu coupon $100 off for customers • acq794628: Temu $100 extra off (Temu 100$ coupon code) • acq794628: $100 discount for new users (100 off Temu coupon) • acq794628: $100 coupon for existing and new users (Temu coupon code 100 off) Why Choose Temu? Before we dive deeper into the Temu $100 coupon bundle, let's look at what makes Temu stand out: 1. Vast product selection 2. Unbeatable prices 3. Fast and free shipping 4. User-friendly platform 5. Regular promotions and discounts How to Use Your Temu Coupon Code $100 Off Using your Temu coupon code $100 off is a breeze. Here's a step-by-step guide to help you make the most of your savings: 1. Browse Temu's extensive catalog 2. Add items to your cart 3. Proceed to checkout 4. Enter your Temu coupon code $100 off in the designated field 5. Watch your total drop by $100! Tips for Maximizing Your Savings To get the most bang for your buck,. consider these strategies: 1. Combine your Temu coupon $100 off with ongoing sales 2. Look for bundle deals to increase your savings 3. Check Temu's daily deals for additional discounts 4. Sign up for Temu's newsletter to stay informed about upcoming promotions Temu Coupon $100 Off: Frequently Asked Questions You might be wondering about the details of these incredible offers. Let's address some common questions: Is the Temu $100 off coupon legit? Absolutely! The Temu 100 off coupon is legit and has been verified by countless happy customers. You can shop with confidence knowing that your Temu coupon code $100 off will be honored at checkout. Can I use the Temu coupon $100 off for existing customers on my first order? While the Temu coupon $100 off for existing customers is designed for repeat shoppers, new users can take advantage of the Temu coupon code $100 off for new users. Both offers provide the same great savings! How often can I use a Temu coupon $100 off? Typically, these coupons are one-time use per account. However, Temu frequently releases new promotions, so keep an eye out for fresh opportunities to save! Explore Temu's Best Deals with Your $100 Off Coupon Now that you're armed with your Temu coupon code $100 off, let's look at some popular categories where you can apply your savings: • Electronics • Fashion • Home & Garden • Beauty & Personal Care • Sports & Outdoors Hot Deals Alert: Temu Coupon Codes Don't miss out on these amazing offers: • acq794628: Temu coupon $100 off for existing customers free shipping • acq794628: Temu coupon $100 off for new users • acq794628: Temu coupon codes 100 off • acq794628: Temu coupon $100 off code • acq794628: Temu coupon $100 off first-time user Make the Most of Your Temu Shopping Experience As you explore Temu's vast catalog with your Temu coupon $100 off in hand, keep these tips in mind: 1. Read product reviews from other customers 2. Check sizing charts for clothing and shoes 3. Compare similar items to find the best value 4. Take advantage of Temu's customer service for any questions The Temu Difference What sets Temu apart from other e-commerce platforms? It's not just about the Temu $100 coupon bundle – it's the overall shopping experience. With a user-friendly interface, a wide range of products, and unbeatable prices, Temu is revolutionizing online shopping. I've been using Temu for months now, and I can confidently say that the savings are real. Whether you're a new user looking to score a great deal with a Temu coupon code $100 off first order or an existing customer ready to use your Temu coupon $100 off for existing customers first order, you're in for a treat. Conclusion: Shop Smart with Temu In today's economy, finding ways to save money without sacrificing quality is crucial. That's why I'm thrilled to share these Temu coupon $100 off opportunities with you. Whether you're shopping for yourself or looking for the perfect gift, Temu has you covered. Remember, the key to maximizing your savings is to stay informed about the latest promotions. Bookmark this page and check back regularly for updates on Temu coupon codes and deals. And don't forget – your Temu coupon code $100 off [acq794628] for existing customers is waiting to be used! Happy shopping, and enjoy your incredible savings with Temu! .
Last updated: 2024-10-26
Post by cfam on Codesys Control for PLCnext (PLC - AXL F 2152)
CODESYS Forge
talk
(Post)
Good day All I would like to share some information on this site for the Codesys team as well for the future members using Codesys Control for PLCnext if it is allowed. I hope that i Post it in the correct spot. Subject: Codesys, Codesys Control for PLCnext Objective: Using the following Phoenix components to built a PLC Rack and run it on Codesys: Hardware and Software used 1. 2404267, AXC F 2152 - Controller 2. 1088136, AXL F BP SE6 - Module carrier 3. 1088129, AXL SE DO16/1 - Digital module 4. 1337224, AXL SE PD16 GND - Potential distributors 5. 1088127, AXL SE DI16/1 - Digital module 6. 1337223, AXL SE PD16 24V - Potential distributors 7. 1088123, AXL SE AO4 I 4-20 - Analog module 8. 1088134, AXL SE SC-A - Cover 9. Codesys v3.5 SP19 Patch 4 10. Codesys Control for PLCnext V4.10.0.0 Process: Firstly I built the Rack according to the Phoenix Project+ Software tool. Where I rebuilt it onto my test bench . I used the PLCnext Engineer IDE from Phoenix and all Communications where up and running and my PLC program executed successfully. THEN I tried the same PLC Layout with Codesys and Codesys Control for PLCnext. It was not successful and gave me the "Error: Local Bus not Running". I searched the web for answers but was unsuccessful in finding a solution. So I tried to change my configuration and found that the following Modules COULD NOT be recognized by Codesys Control. The result was that the Local Bus Failed to run. 1337224, AXL SE PD16 GND - Potential distributors 1337223, AXL SE PD16 24V - Potential distributors Example 1, Resulted in "Error: Local Bus Not Running": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1337224, AXL SE PD16 GND - Potential distributors Module carrier slot 3: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 4: 1337223, AXL SE PD16 24V - Potential distributors Module carrier slot 5: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 6: 1088134, AXL SE SC-A - Cover Example 2, Result "Successful": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 3: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 4: 1088134, AXL SE SC-A - Cover Module carrier slot 5: 1088134, AXL SE SC-A - Cover Module carrier slot 6: 1088134, AXL SE SC-A - Cover Result: Codesys or Codesys Control for PLCnext, has a PROBLEM to identify the following Modules. 1. AXL SE PD16 24V - Potential distributors 2. AXL SE PD16 GND - Potential distributors Hope that this information could be useful in future. Best regards Jaco Pretorius
Last updated: 2023-12-06
Post by smeitink on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module
CODESYS Forge
talk
(Post)
Hi all, I'm looking for help with an issue I've come across while trying to facilitate Modbus communication between a WAGO PFC200 PLC using a 750-652 communication module and an iEM2050 Series Single Phase Energy Meter. I believe to have everything wired and setup correcty, but I keep running into a "Error time out" message, and by now I don't really know what else to try. My setup is as follows: A PFC200 Wago PLC, which has 2 750-652 Serial Interfaces extension modules connected to its field bus. I'm using one of these to talk to a Schneider iEM2050 - kWh-meter over modbus. I have connected terminal 23 (A) of the iEM2050 to connector 6 (A) on the 750-652. I have connected terminal 24 (B) of the iEM2050 to connector 2 (B) of the 750-652. I'm using 200mm of twisted together wires to connected them both, and I have placed a 120 ohm resistor between A and B at both ends. I've attached relevant pinout images to this post. I then wrote a simple program that configures the Mobus port, as per the datasheet of the iEM2050. You can find an image of the relavent page attached to this post too. This is my program: PROGRAM PLC_PRG VAR Master: FbMbMasterSerial; xIsConnected: BOOL; xError: BOOL; iIndex: INT := 1; xTrigger: BOOL; utQuery : typMbQuery := ( bUnitId := 1, // The Modbus unit or slave address bFunctionCode := 4, // Function code for reading input registers uiReadAddress := 1829, // adress for the Power on off counter uiReadQuantity := 1 // Quantity of registers to read ); iStep: INT; oStatusModbus: WagoSysErrorBase.FbResult; utResponseModbus: typMbResponse; xConnect: BOOL := FALSE; delayTimer: TON; END_VAR Master( xConnect:= xConnect, I_Port:= _750_652_24_1, udiBaudrate:= 9600, usiDataBits:= 8, eParity:= WagoTypesCom.eTTYParity.Even, eStopBits:= WagoTypesCom.eTTYStopBits.One, eHandshake:= WagoTypesCom.eTTYHandshake.None, ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485_HalfDuplex, xIsConnected=> xIsConnected, xError=> xError, oStatus=> oStatusModbus, eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU, tTimeOut:= T#5S, utQuery:= utQuery, xTrigger:= xTrigger, utResponse:= utResponseModbus); delayTimer(IN := TRUE, PT := T#3S); // Use the Q output of the timer to set xConnect after the delay IF delayTimer.Q THEN xConnect := TRUE; END_IF CASE iStep OF 0: //Wacht totdat de master de poort geopend heeft IF xIsConnected THEN iStep := 1; END_IF 1: //Stuur request naar de slave xTrigger := TRUE; iStep := 2; 2: //Wacht totdat de master klaar is met het afhandelen van de request IF NOT xTrigger THEN iStep := 3; END_IF END_CASE The TON delay before opening the port is due to a an error I encountered when opening it straight away. This seems to be a bug, as described here. However, the TON solved that particular issue. I tried reading multiple registers, but like I said, I still always end up with the "Error time out". What else can I test or try at this point?
Last updated: 2024-02-24
Post by kuegerls on PROFINET Controller SL: WRREC remains BUSY forever, no DCE/RPC packets transmitted (RevPi Connect 5 + NORD SK205E)
CODESYS Forge
talk
(Post)
Hello , I am currently evaluating the CODESYS PROFINET Controller SL on a Revolution Pi Connect 5 and have encountered a problem with acyclic PROFINET Record Access (WRREC/RDREC). System Hardware: Revolution Pi Connect 5 Runtime: CODESYS Control 4.16.0.0 (SDK 3.5.21.10) Development System: CODESYS V3.5 SP21 (64-bit) CommFB: 3.5.17.10 ProfinetCommon: 4.6.0.0 PROFINET Controller Device: PN-Controller 4.6.0.0 PROFINET Device: NORD DRIVESYSTEMS SK205E with SK TU4-PNT GSDML: GSDML-V2.46-NORDDRIVESYSTEMS-PNT-20251016.xml Network The PROFINET network is completely separated from the office network. RevPi: eth0 → Office network eth1 → PROFINET wlan0 → Visualization The PN Controller is configured to use eth1. IP configuration: RevPi (eth1): 192.168.100.1/24 NORD Drive: 192.168.100.3 Connection is established successfully. Current Status The PN Controller reports: Controller Status = Run Online = TRUE IP Active = TRUE Connections = 1 Cyclic PROFINET IO communication works correctly. Problem I am trying to access PKW parameters via WRREC (Record Index 100). The request buffer contains: 01 14 00 04 92 00 00 00 00 00 00 which corresponds to Reference = 0x01 Request = Read Axis = 0 Parameter = 170 + 1000 Subindex = 0 Value = 0 The WRREC call is fbWRREC( REQ := xWrReq, ID := ConnectionID, INDEX := 100, LEN := 11, RECORD := ADR(TxBuffer) ); REQ is pulsed for one PLC cycle only. Observed Behaviour WRREC enters BUSY state and never finishes. Observed values: BUSY = TRUE DONE = FALSE ERROR = FALSE STATUS = 16#FFFFFFFF indefinitely. Packet Capture A Wireshark capture was taken on the PROFINET network. Observed traffic: PROFINET RT LLDP DCP Observed: successful cyclic IO Not observed: DCE/RPC Record Write Record Read RPC Bind No RPC packets are transmitted at all. Diagnostic Messages The controller repeatedly reports AR alarm.ind(err) AR CMI timeout although cyclic IO communication continues to work. Already Verified The following points have already been checked: correct Ethernet interface (eth1) correct CREATE_ID result correct Device ID correct Slot/Subslot correct GSDML correct REQ pulse RECORD buffer is larger than LEN cyclic IO communication works different Record Indices (100...104) tested Question Is there any known issue or limitation where WRREC/RDREC requests remain permanently BUSY and no RPC Record Access packets are generated? Could this behaviour be related to Runtime 4.16.0.0, PN Controller 4.6.0.0, the missing runtime license (currently running in demo mode), or any known issue with the PROFINET Controller SL? I am currently evaluating the PROFINET Controller SL and therefore the runtime is operating in demo mode. Could you please confirm whether WRREC/RDREC (acyclic Record Data services) are fully supported in demo mode, or whether a valid license is required for these services? If required, I can provide: complete project archive Wireshark capture (.pcap) GSDML online screenshots diagnostic log Thank you very much for your help. Best regards, Stefan
Last updated: 2026-07-17
Post by t-probst on Strong Private Key Protection for Encryption Certificates
CODESYS Forge
talk
(Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22
Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i´m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i´m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i´m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10
Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection
CODESYS Forge
talk
(Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03
Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable
CODESYS Forge
talk
(Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29
Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4
CODESYS Forge
talk
(Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-20
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14
Post by mariapaola on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3
CODESYS Forge
talk
(Post)
Hi, Would really appreciate your insights in this issue I have. I am currently using a WAGO 750-881 with multiple IO devices. For one of them I already occupied the MODBUS Master configuration tool so I cannot overwrite it for my other devices. I have a total of two serial interfaces WAGO 750-652. The first one is instantiated in COM2 and doesn't need any protocol since the information comes in an specific formatting that need little code to differentiate between needed info. This one is working just fine. The second one is where I have an issue. I have tried to instantiate the port using MODBUS library modb_L05.lib to properly receive the data from an ARDUINO and I am absolutely unable to open the port: Signal DEVICE2.fbModbus.MODBUS_EXT_MASTER.Interface.Com_Port_Ist_Offen is never TRUE, among with all other signals from that interface, while signal DEVICE1.COM2.Com_Port_Ist_Offen is TRUE, and the other signals also read as TRUE or FALSE. I have tried instantiating the second one as the first one, changing COM3 to COM4, I've tried a lot of things but it wont ever open the channel. I don't know if you have any recommendations for me. For both physical modules, both witness LEDs A and E are on. First one is instantiated like this: PROGRAM DEVICE1 VAR wBaudRate : WORD := BAUD_9600; bDataBits : BYTE := 8; bParity : BYTE := 0; bFlowControl : BYTE := 3; (RS422 FullDuplex with continous send) i : INT; COM2 : SERIAL_INTERFACE; xOpenPort2 : BOOL := TRUE; ( Flag to open the Port ) xInitPort2 : BOOL; ( Flag to initiallize the Port ) ReceiveBuffer2 : typRing_Buffer; END_VAR COM2( bCOM_PORT_NR := 2, cbBAUDRATE := wBaudRate, cbsBYTESIZE := bDataBits, cpPARITY := bParity, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := bFlowControl, utRECEIVE_BUFFER := ReceiveBuffer2, ptSEND_BUFFER := ADR(SendString2), xINIT := xInitPort2, xOPEN_COM_PORT := xOpenPort2, iBYTES_TO_SEND := LEN(SendString2)+1, xSTART_SEND := xSendActive2 ); Second one like this: PROGRAM DEVICE2 VAR COM4 : SERIAL_INTERFACE; xInitPort4 : BOOL := TRUE; xOpenPort4 : BOOL := TRUE; ReceiveBuffer4 : typRing_Buffer; fbModbus : MODBUS_EXTENDED_MASTER_RTU; fbError : enumMB_ERROR; stQuery : typModbusExtendedQuery; stResponse : typModbusResponse; au16Data : ARRAY[0..14] OF WORD; i : INT; tPoll : TON; END_VAR COM4( bCOM_PORT_NR := 4, cbBAUDRATE := BAUD_9600, cbsBYTESIZE := 8, cpPARITY := 0, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := 2, ( RS-485 half-duplex ) utRECEIVE_BUFFER := ReceiveBuffer4, xINIT := xInitPort4, xOPEN_COM_PORT := xOpenPort4, xSTART_SEND := xSendActive4, ); stQuery.SlaveAddress := 1; stQuery.FunctionCode := 3; stQuery.Read_StartAddress := 0; stQuery.Read_Quantity := 15; (Poll code) fbModbus( ENABLE := TRUE, bCOM_PORT := 4, ( COM4=> 750-652 port ) cbCOM_BAUDRATE := BAUD_9600, cpCOM_PARITY := 0, csCOM_STOPBITS := 1, cbsCOM_BYTESIZE := 8, cfCOM_FLOW_CONTROL := 2, TimeOut := T#500ms, StartFunction := xStart, ExtQuery := stQuery, Response := stResponse, MB_Error => fbError ); FOR i := 0 TO 14 DO au16Data[i] := stResponse.Data[i]; END_FOR;
Last updated: 2025-11-28
Post by bertus on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hello all, I am trying to run a XY trajectory from a static G-Code file. Everything works except the smoothing/blending of the corners. My setup: Codesys v3.5sp18 Raspberry Pi 4 CODESYS Control for Raspberry Pi SL, using demo license. Zero axes (only using the interpolator). The order of processing for my decoding is: SMC_NCDecoder (ok) SMC_SmoothMerge (ok) SMC_SmoothPath (not ok) SMC_LimitDynamics SMC_CheckVelocities I created following instances and buffers: fbNCDecoder: SMC_NCDecoder; fbSmoothMerge: SMC_SmoothMerge; fbSmoothPath: SMC_SmoothPath; fbLimitDynamics: SMC_LimitDynamics; fbCheckVelocities: SMC_CheckVelocities; aNCDecoderBuffer: ARRAY[0..49] OF SMC_GeoInfo; // buffer stage 1 (fbNCDecoder) aSmoothMergeBuffer: ARRAY[0..19] OF SMC_GeoInfo; // buffer stage 2 (fbSmoothMerge) aSmoothPathBuffer: ARRAY[0..99] OF SMC_GeoInfo; // buffer stage 3 (fbSmoothPath) aLimitDynamicsBuffer: ARRAY[0..39] OF SMC_GeoInfo; // buffer stage 4 (fbLimitDynamics) My original G-Code file has a lot of short G1 elements but this example, I reduced it to a simple square: N000 G51 D10 N010 G38 O1 N020 G00 X0 Y0 F50 E1000 E-1000 N030 G01 X0 Y-37.5 N040 G01 X-75 Y-37.5 N050 G01 X-75 Y37.5 N060 G01 X0 Y37.5 N070 G01 X0 Y0 N080 G50 N090 G39 O1 In the Codesys CNC settings, I have these instances activated: SMC_SmoothMerge SMC_SmoothPath SMC_LimitDynamics SMC_CheckVelocities And with those settings (and the path-preprocessing button actived), the G-Code viewer shows the square with nicely blended corners (see attached picture). However, when running it on the PLC, it doesn't blend the corners at all. Below the relevant part of my code. The process is started with bDecode. // stage 1: decoding G-code fbNCDecoder( ncprog := square, bExecute:= bDecode, bAbort:= NOT bDecode, nSizeOutQueue := SIZEOF(aNCDecoderBuffer), pbyBufferOutQueue := ADR(aNCDecoderBuffer) ); // stage 2: merge short linear segments fbSmoothMerge( bExecute := bDecode, poqDataIn := fbNCDecoder.poqDataOut, nSizeOutQueue := SIZEOF(aSmoothMergeBuffer), pbyBufferOutQueue := ADR(aSmoothMergeBuffer), piMaxDifference := PI_MAX_DIFFERENCE, usiMaxDegree := 5, wFeatureFlag := 1, wAdditionalParamNumber := 0, dMinimumCurvatureRadius := D_MIN_CURVATURE_RADIUS ); // stage 3: smooth corners fbSmoothPath( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothMerge.poqDataOut, eMode := SMC_SMOOTHPATHMODE.SP_SPLINE5_MIN_CURVATURE, eAddAxMode := SMC_SMOOTHPATHADDAXMODE.SPAA_NONE, nSizeOutQueue := SIZEOF(aSmoothPathBuffer), pbyBufferOutQueue := ADR(aSmoothPathBuffer), dAngleTol := D_ANGLE_TOL, bSymmetricalDistances := TRUE, bImprovedSymmetricCuts := TRUE ); // stage 4: keep acc/dec and velocity within limits fbLimitDynamics( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothPath.poqDataOut, wAxis := 16#07, nSizeOutQueue := SIZEOF(aLimitDynamicsBuffer), pbyBufferOutQueue := ADR(aLimitDynamicsBuffer), bIncludePathSettings := TRUE, dMaxVel := 2500, dMaxAccDec := 10000 ); // stage 5: check the path speed fbCheckVelocities( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbLimitDynamics.poqDataOut, dAngleTol := D_ANGLE_TOL); pathQueue := fbCheckVelocities.poqDataOut; // repeat until MaxDuration ... Any idea what I'm doing wrong? Is smooth path supposed to work at all when using a demo license? Thanks.
Last updated: 2025-12-17
Post by risele on dynamic modbus devices
CODESYS Forge
talk
(Post)
Have the same issue: I'm making a test setup for modbus devices testing and calibration. One is run for every possible address, and it starts with minimal request: if the device is found, it continue to work with it, otherwise it's set to Disabled temporary. Those state machines are running under FOR cycle, and disabled are just skipped. Every instance have its own timer for not running too frequently and a start delay, so the actual requests are separate in time. I also check not for a single error, but have some timer to allow one-two timeouts. The small program disables and re-enables devices temporary (manually, since i could not iterate over MB devices). VAR Reset:ARRAY[1..GVL_MB.MD_COUNT] OF R_TRIG; i:INT; END_VAR {IF hasconstantvalue(GVL_MB.MD_COUNT, 1, >= )} i:=1; MD_1.Enable:=GVL_MB.MDPortsEnable[i]; Reset[i](CLK:=GVL_MB.MDPortsEnable[i]); MD_1.xReset:=Reset[i].Q; {END_IF} {IF hasconstantvalue(GVL_MB.MD_COUNT, 2, >= )} i:=2; MD_2.Enable:=GVL_MB.MDPortsEnable[i]; Reset[i](CLK:=GVL_MB.MDPortsEnable[i]); MD_2.xReset:=Reset[i].Q; {END_IF} There is also program to re-enable devices periodically. METHOD ScanBus VAR_INPUT END_VAR VAR j:INT; (*block auto scanning if calibration is running for any device since it's data-reach process that should not be interrupted with modbus timeouts *) CalibrationBusy:BOOL:=FALSE; END_VAR CalibrationBusy:=FALSE; FOR j:=1 TO GVL_MB.MD_COUNT DO CalibrationBusy:=CalibrationBusy OR MD_Calibrate.AutoTesters[j].xBusy; END_FOR; IF CalibrationBusy THEN RETURN; END_IF tBusScanSchedule(IN:=(NOT tBusScanSchedule.Q), PT:=tBusScanPeriod); IF (NOT tBusScanDelayer.Q) AND (tBusScanSchedule.Q OR (NOT xFirstScanPerforemed)) THEN xBusScanBusy:=TRUE; MissingCounter:=0; xFirstScanPerforemed:=TRUE; FOR j:=1 TO GVL_MB.MD_COUNT DO (* MD_Calibrate is main calibration program. Identifiers - is array of State machines mentioned above Phase_Faulted is a state of Identifiers where I'm sure device is missing on the bus *) IF MD_Calibrate.Identifiers[j].state=eStateMDIdentifier.Phase_Faulted THEN MD_Calibrate.Identifiers[j].Rescan(); MissingCounter:=MissingCounter+1; END_IF END_FOR END_IF tBusScanPauser(IN:=tBusScanDelayer.Q AND (MissingCounter>0),PT:=tBusScanDelay*MissingCounter); xBusScanBusy:=tBusScanPauser.Q; xFirstScanPerforemed:=xFirstScanPerforemed OR tBusScanPauser.ET>=tBusScanPauser.PT; Also the GUI have buttons for each address possible that re-enables the device if required.
Last updated: 2026-02-13
Post by alexschooneveld on OPC UA PubSub SL 1.3 — UADP WriterGroup with assigned PSS.SecurityGroup still publishes plaintext
CODESYS Forge
talk
(Post)
I am currently investigating an OPC UA PubSub connection over UDP. When I don't use encryption, the publish and subscribe are working correctly. But with encryption it does not. Environment OPC UA PubSub SL 1.3.0.0 (namespace UADP) OPC UA PubSub Security 1.3.0.0 (namespace PSS) OPC UA PubSub Base 1.3.0.0 (namespace PSB, incl. PSS.SecurityGroup / PSS.CONFIG) Programmatic PubSub in a CFC: UADP.Configuration → UADP.Connection → UADP.writerGroup → UADP.writer → writerDataSet, plus a CyclicCall gated by xEnable. Goal: publish secured UADP, SignAndEncrypt, policy PubSub-Aes256-CTR. What I do (one-shot, before xEnable := TRUE): fbSecurityGroup.SetInitialValue( 'http://opcfoundation.org/UA/SecurityPolicy#PubSub-Aes256-CTR', PSB.SECURITY.SIGNING_AND_ENCRYPTION); stSecurityCfg := fbSecurityGroup.GetConfig(eErrorID => eError); // eError=NO_ERROR, udiEncryptionKeySize=32 eError := fbSecurityGroup.SetSecurityKeys(udiTokenId, ADR(abyKey), SIZEOF(abyKey), 2436001000); // eError=NO_ERROR, SIZEOF=68 // writerGroup.itfSecurityGroup := fbSecurityGroup -- set in the WriterGroup block's Parameters (a per-scan code write got overwritten) What I verified eError = NO_ERROR after both GetConfig and SetSecurityKeys; udiEncryptionKeySize = 32. Key length = 68 bytes (signing 32 ‖ encrypt 32 ‖ nonce 4). itfSecurityGroup is set via the WriterGroup's Parameters (so it isn't clobbered each scan). Init runs before xEnable (the writer doesn't run with xEnable=FALSE). The UADP.writerGroup FB exposes only itfSecurityGroup for security — no SecurityMode/MessageSecurityMode property. Result: the published datagrams are still plaintext — ExtendedFlags1 = 0x01 (security bit 0x10 clear), no security header: b1 01 29 00 0f 16 00 … (PublisherId 41, WriterGroupId 22, RawData, no security) Questions With UADP.writerGroup, is assigning a configured + keyed PSS.SecurityGroup to itfSecurityGroup sufficient to enable message security, or is there an additional step/property/method to switch the WriterGroup to SignAndEncrypt? At what point in the WriterGroup lifecycle is itfSecurityGroup read? Must it be assigned/keyed before xActive, and does the group need a stop→start to pick it up? Is there a required call order, and does SetSecurityKeys need to be called once or repeatedly? Should security be configured on the Connection/Configuration level rather than (or in addition to) the WriterGroup? Is there a working example of secured (SignAndEncrypt) programmatic UADP publishing with this library, or a known limitation in 1.3? How can I read back at runtime whether security is actually active (via itfDiagnostics or similar)? Additional information I can confirm that the consumer side works — i.e. a standard subscriber decrypts the same keys fine — so the keys/profile aren't the issue. The Wireshark capture of the published message is: 0000 b1 01 29 00 0f 16 00 df 0d bb 25 01 00 0e 00 1b ..).......%..... 0010 0e 00 00 00 00 00 00 00 ........
Last updated: 2026-06-22
Post by alexschooneveld on OPC UA PubSub SL 1.3 — UADP WriterGroup with assigned PSS.SecurityGroup still publishes plaintext
CODESYS Forge
talk
(Post)
I am currently investigating an OPC UA PubSub connection over UDP. When I don't use encryption, the publish and subscribe are working correctly. But with encryption it does not. Environment OPC UA PubSub SL 1.3.0.0 (namespace UADP) OPC UA PubSub Security 1.3.0.0 (namespace PSS) OPC UA PubSub Base 1.3.0.0 (namespace PSB, incl. PSS.SecurityGroup / PSS.CONFIG) Programmatic PubSub in a CFC: UADP.Configuration → UADP.Connection → UADP.writerGroup → UADP.writer → writerDataSet, plus a CyclicCall gated by xEnable. Goal: publish secured UADP, SignAndEncrypt, policy PubSub-Aes256-CTR. What I do (one-shot, before xEnable := TRUE): fbSecurityGroup.SetInitialValue( 'http://opcfoundation.org/UA/SecurityPolicy#PubSub-Aes256-CTR', PSB.SECURITY.SIGNING_AND_ENCRYPTION); stSecurityCfg := fbSecurityGroup.GetConfig(eErrorID => eError); // eError=NO_ERROR, udiEncryptionKeySize=32 eError := fbSecurityGroup.SetSecurityKeys(udiTokenId, ADR(abyKey), SIZEOF(abyKey), 2436001000); // eError=NO_ERROR, SIZEOF=68 // writerGroup.itfSecurityGroup := fbSecurityGroup -- set in the WriterGroup block's Parameters (a per-scan code write got overwritten) What I verified eError = NO_ERROR after both GetConfig and SetSecurityKeys; udiEncryptionKeySize = 32. Key length = 68 bytes (signing 32 ‖ encrypt 32 ‖ nonce 4). itfSecurityGroup is set via the WriterGroup's Parameters (so it isn't clobbered each scan). Init runs before xEnable (the writer doesn't run with xEnable=FALSE). The UADP.writerGroup FB exposes only itfSecurityGroup for security — no SecurityMode/MessageSecurityMode property. Result: the published datagrams are still plaintext — ExtendedFlags1 = 0x01 (security bit 0x10 clear), no security header: b1 01 29 00 0f 16 00 … (PublisherId 41, WriterGroupId 22, RawData, no security) Questions With UADP.writerGroup, is assigning a configured + keyed PSS.SecurityGroup to itfSecurityGroup sufficient to enable message security, or is there an additional step/property/method to switch the WriterGroup to SignAndEncrypt? At what point in the WriterGroup lifecycle is itfSecurityGroup read? Must it be assigned/keyed before xActive, and does the group need a stop→start to pick it up? Is there a required call order, and does SetSecurityKeys need to be called once or repeatedly? Should security be configured on the Connection/Configuration level rather than (or in addition to) the WriterGroup? Is there a working example of secured (SignAndEncrypt) programmatic UADP publishing with this library, or a known limitation in 1.3? How can I read back at runtime whether security is actually active (via itfDiagnostics or similar)? Additional information I can confirm that the consumer side works — i.e. a standard subscriber decrypts the same keys fine — so the keys/profile aren't the issue. The Wireshark capture of the published message is: 0000 b1 01 29 00 0f 16 00 df 0d bb 25 01 00 0e 00 1b ..).......%..... 0010 0e 00 00 00 00 00 00 00 ........
Last updated: 2026-06-22
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by shooxplc on How to call the same program from library and get the vars updated.
CODESYS Forge
talk
(Post)
Hi, I am writing to you today because I would like to create a library that would contain a program with its various subprograms, in my example "PLC_PRG" with "a", "aa", "aaa". But once the library is created as shown below: I would like to be able to drag and drop my folder as many times as I want (let's say I manage the same system multiple times). Once the drag and drop is done, we can see the second folder with the variables renamed successfully. As shown below: But my variables in CAD_1 remain the same as for CAD, so it's PLC_PRG instead of PLC_PRG_1, for example. Is there a solution to automate this? I wouldn't want to have to rename all my variables manually, considering that in the program where I want to do this, the number of variables is substantial. Lucas.
Last updated: 2023-08-23
Post by timvh on Detect "Cancel" Press in FileOpenSave Dialog
CODESYS Forge
talk
(Post)
Maybe there is a better way, but a long time ago I created a test application that worked like this: With a button I opened the dialog and I added a "Input configuration - OnDialogClosed" "Execute ST-Code" action to this same button which called the following Function when the dialog was closed: F_OnFileDialogClosed(pClientData); Below this Function which handled the result: // This function is called from the visualization when the dialog is closed. FUNCTION F_OnFileDialogClosed : BOOL VAR_INPUT pClientData : POINTER TO VisuElems.VisuStructClientData; END_VAR VAR dialogMan : VisuElems.IDialogManager; FileOpenCloseDialog : VisuElems.IVisualisationDialog; result : VisuElems.Visu_DialogResult; _sFileName : STRING(255); END_VAR // the DialogManager is provided via the implicitly available VisuManager dialogMan := VisuElems.g_VisuManager.GetDialogManager(); IF dialogMan <> 0 AND pClientData <> 0 THEN FileOpenCloseDialog := dialogMan.GetDialog('VisuDialogs.FileOpenSave'); // gets the FileOpenSave dialog IF FileOpenCloseDialog <> 0 THEN result := FileOpenCloseDialog.GetResult(); // gets the result (OK, Cancel) of the dialog IF result = VisuElems.Visu_DialogResult.OK THEN // Original code gvlFile.FileListProvider(); _sFileName := CONCAT(gvlFile.FileListProvider._stDirectory, gvlFile.FileListProvider.stFile); // do something with this file name... END_IF END_IF END_IF
Last updated: 2023-09-19
Post by damian177 on Codesys and SMS in RPi
CODESYS Forge
talk
(Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?
Last updated: 2023-09-29
Post by ryusoup on JSONByteArrayWriter problem?
CODESYS Forge
talk
(Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,
Last updated: 2023-10-04
Post by captaincookie on increase default string length in queue
CODESYS Forge
talk
(Post)
Hello, I'm using Codesys V3.5 SP18 Patch 4. In the ElementCollectionExample Project from Codesys, I test the SimpleQueueExample in a Control Win V3 x64 environment. I try to add a string of 95 characters length to a queue. The default length of strings is defined as 80 characters. In the initialization of a string variable, it is possible to increase the length by the definition of e.g. STRING(1000). But when I write the string defined like this to the queue, only 80 characters are written to it and the rest is missing. I think the default length is still set in the queue definition, so it is necessary to change this, isn't it? Is there any option to increase the default length of strings in the queue? Attached you can find the used project. Thanks in advance. If any information are missing or my description unclear please let me know.
Last updated: 2023-10-05
Post by janber0206 on Gateway doesn't come online, regarding a working internet connection
CODESYS Forge
talk
(Post)
Solved EN: The Problem is that the Codesys Edge-Gateways have a License with a runtime of an half year, as long the Gateways are online they will self renew themselfs. In my Case the RevPi was more than a year offline and so the Edge-Gateway was not working anymore. The solution: I accessed a laptop that was directly connected to the RevPi. I installed the Codesys service tool and renewed the certificate manual. DE: Das Propblem ist das die Codesys Edge-Gatways eine Lizenz haben die nur ein halbes Jahr gültig ist. Solange das Gateway eine Internet verbindung hat aktualisiert sich das Zertifikat von alleine. In meinem Fall war das Gateway aber über ein Jahr offline und hat somit nicht mehr funktioniert. Die Lösung: Ich hab auf einen Laptop von Kunden mit TeamViewer zugegriffen, der Laptop wurde mit Kabel direkt mit RevPi verbunden. Codesys Service Tool installiert und dann das Gatewayzertifikat aktualisiert.
Last updated: 2023-10-26
Post by riccardo on VisuElems.CurrentUserGroupId is not stable
CODESYS Forge
talk
(Post)
GoodMorning everyone. I have a system that, in case of alarm, have to block. When the operator logs in must have to acknoledge the alarm and should operate in the system freely. To perform this I detect the logged User by (VisuElems.CurrentUserGroupID <> 0) with a similar code to the the following: PROGRAM AlarmMngt VAR alarm : BOOL:= FALSE; Ack : BOOL:= TRUE; PushBottonOpening : BOOL:= FALSE; Valve : BOOL := FALSE; Flag: BOOL := FALSE; END_VAR IF alarm AND Ack AND (NOT Flag) THEN valve := FALSE; PushBottonOpening := FALSE; Ack := FALSE flag := TRUE; ELSIF (NOT alarm) AND Ack THEN flag := FALSE; END_IF (* if the system is in alarm but there is a logged operator that acknowledge the alarm the system allows the valve opening.*) IF (VisuElems.CurrentUserGroupID <> 0) AND Ack AND Alarm AND PushBottonOpening THEN Valve := TRUE; ELSIF (VisuElems.CurrentUserGroupID = 0) AND Alarm THEN valve := FALSE; END_IF The problem I have is in the last 5 lines of the code: Even if there is a logged in user, the GroupID variable is subjected to a refresh that cyclically set for an instant it to 0 and this close the valve making difficult to the user to work Now I solved it creating a time hysteresys cycle but it is not a good solution. Someone is able to explane me why the GroupID variable is sobjected to this refresh and how to stabilize to avoiding it? Thank you in advance, Riccardo
Last updated: 2023-11-10
Post by mm-sceg on Runtime geht sporadisch in Störung -> RaspiPi4 reagiert nicht mehr
CODESYS Forge
talk
(Post)
Guten Tag, ich hab seit längerem das Problem, dass mein Raspberry Pi4 durch die PLC in Störung geht. Auf dem Raspi läuft eine einfache Software mit OPC UA server, InfluxDB und ein NodeRed-Server. (Und MQTT-Server) Daten werden von der PLC über OPC-UA an NodeRed übergeben. Es kann sein, dass der Raspi 2 Wochen läuft, dann geht die PLC in Stopp. Manchmal nur 2-3 Tage. Ein Neustart über Spannung aus & wieder an schafft Abhilfe. NodeRed wirft extrem viele Fehlermeldungen in kurzer Zeit. Wenn die PLC in Störung ist, kann man sich nicht mal mehr über SSH beim Raspi einloggen. Der Raspi ist aktiv gekühlt und im Normalbetrieb nicht überlastet. Ich hab einige logfiles mit vielen Einträgen die mir nichts sagen, eventuell hat hier jemand eine Idee wie ich dem Problem Herr werden kann :) Der letzte Datenbankeintrag von der SPS war am 11.11.2023 um 5:55:50 Uhr. D.h. danach muss die SPS gestorben sein. Siehe Raspi-Log im Anhang. Das LogFile von Codesys startet leider erst um 11 Uhr, weshalb weiß ich leider nicht. Vielen Dank schonmal
Last updated: 2023-11-11
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.