Post by maldus512 on How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Post)
Hello everyone, I have been given the task to develop I/O drivers for a custom made, Linux based board to allow for Codesys applications to run and control the hardware. I have successfully installed Codesys Control SL for ARM/Linux and tested it with a simple demo application. Now I should start interfacing the runtime to the actual hardware; I should be able to interact with 2 RS485 serial ports, a few GPIOs and an I2C port, all of which already have the corresponding /dev/ interface in the Linux system. I am having trouble understanding how it should be approached. I have found sporadic references that fail to lead to a really comprehensive documentation. For example: The store page (https://store.codesys.com/en/codesys-control-for-linux-arm-sl-1.html#options) mentions a "runtime package" that should allow "Integration of existing C code" and "Usage of local I/Os", which seems exactly what I need to interact with custom peripherals. I have found no further reference to Codesys-C interpop. The Codesys Help page for the runtime package has a page on the "Development of Drivers" (https://content.helpme-codesys.com/en/CODESYS%20Control/rtsllinuxrbpdriverdevelopment.html) that suggests to either "Implement a function block" or "Implement I/O drivers". Those in turn lead to this page (https://forge.codesys.com/drv/io-drivers/doc/Generic/) which describes briefly an XML schema to describe new devices; unfortunately, it doesn't mention what to do with such a description (i.e. how does the runtime know about it) or how it is in any way connected to the actual hardware. Could anyone give me some pointers? I should also mention I have no prior experience with Codesys, so maybe I'm missing an obvious answer.
Last updated: 2024-08-09
Post by gorditron on I2C Communication with
CODESYS Forge
talk
(Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag fĂźr die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte fĂźr den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer fĂźr den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer fĂźr die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle fĂźr das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13
Post by elektron785 on GPIO mit Codesys Virtual Control for Linux ARM64 SL
CODESYS Forge
talk
(Post)
Hallo zusammen, ich mĂśchte an einem Entwicklungsboard auf dem der i.MX 8M Plus von NXP aufgesteckt ist die vier zur VerfĂźgung gestellten GPIOs als Ausgänge verwenden. Ich habe mir dazu die Readme-Datei des GPIO-Beispiels von "C:\Program Files\CODESYS 3.5.20.40\CODESYS\CODESYS Control SL Extension Package\4.14.0.0\Examples\GPIO" angeschaut Die Ăbersicht der verfĂźgbaren GPIOs sieht folgendermaĂen aus - wobei ich das auf die reduziert habe, die fĂźr mich von Interesse sind: gpiochip0: GPIOs 0-31, parent: platform/30200000.gpio, 30200000.gpio: gpio-0 (SODIMM206 ) gpio-1 (SODIMM208 ) gpio-2 ( ) gpio-3 ( ) gpio-4 ( |sd-vsel ) out hi gpio-5 (SODIMM210 ) gpio-6 (SODIMM212 ) gpio-7 (SODIMM216 ) gpio-8 (SODIMM218 ) gpio-9 ( ) gpio-10 ( ) gpio-11 (SODIMM16 ) gpio-12 (SODIMM155 |regulator-usb1-vbus ) out lo gpio-13 (SODIMM157 ) gpio-14 (SODIMM185 |regulator-usb2-vbus ) out hi gpio-15 (SODIMM91 )** FĂźge ich nun das GPIO (1 Bit)-Gerät in meinem Codesys-Programm hinzu funktioniert der Bus solange bis ich die Richtung in den GPIO-Parametern von "not used" auf "Output" stelle (siehe Bild gpio_parameter). Dann funktioniert nach Download der Bus nicht mehr. Gibt es noch eine andere MĂśglichkeit das zu steuern oder muss ich noch Einstellungen tätigen? FĂźr die Zeile mit dem echo (export/unexport) aus dem Beispiel fehlen mir trotz sudo die Zugriffsrechte. "The Kernel Linux has deprecated GPIO user space SysFS. However, the kernel config CONFIGGPIOSYSFS is still enabled on Toradex's BSP to support customers using it in their legacy applications. You can check the configuration by running zcat /proc/config.gz | grep CONFIGGPIOSYSFS. For GPIO access from userspace, the new char device API, also known as libgpiod, must be used." Dies steht in der Verwendung der GPIOs - eine AusfĂźhrung des zcat-Kommandos liefert ein =y zurĂźck.
Last updated: 2025-03-17
Post by artplc on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Subject: Solution: CODESYS Freezes Linked to Large Symbol Configuration (OPC UA) Hello everyone, I was experiencing the same problem as many here: CODESYS (v3.5 SP20+) freezing during compilation and download, especially on projects that use OPC UA for SCADA. The only workaround was to run Build > Clean all before every download. I believe I have found the root cause and a permanent solution. The Problem: The issue is directly related to a large Symbol Configuration. In my project, I only need about 700 tags for OPC UA, but the Symbol Configuration list was showing over 250,000 tags. This is because it automatically includes all variables from Global Variable Lists (GVLs) and other memory areas. When any static variable is changed, the IDE tries to rebuild this enormous list, causing it to freeze for several minutes. The Solution: Instead of letting CODESYS export every variable by default, you can use a pragma to tell it which variables or GVLs to exclude from the symbol export process. Place the following pragma at the top of any GVL or data structure that you do not want to be part of the symbol configuration: 1 {attribute 'symbol' := 'none'} 2 VAR_GLOBAL 3 // All variables in this GVL will now be excluded from the 4 // Symbol Configuration by default. 5 InternalVariable1 : INT; 6 InternalVariable2 : BOOL; 7 END_VAR After adding this pragma to all the GVLs that were not needed for OPC UA, the number of tags in my Symbol Configuration dropped to the correct amount. The compilation and download process is now fast again, with no freezing. This method is much more efficient than manually managing the symbol list in the editor. I hope this helps others who are facing this frustrating issue. Best regards.
Last updated: 2025-08-10
Post by timvh on Get Alarm status in Codesys
CODESYS Forge
talk
(Post)
You are right, that you can use the GetState method, but it is not that simple. You first have to get a list of (filtered) alarms from the AlarmManager. You can find an example in Forge how to do this. See https://forge.codesys.com/prj/codesys-example/alarm-manager/home/Home/ Then you can go through this list to get the state of all the (filtered) alarms. See below the code which you could use. This is all based on the example from forge. Create a program: // This example shows how to access alarms via structured text. PROGRAM PLC_PRG VAR xInit : BOOL := TRUE; udiResult : UDINT; fbAlarmFilterCriteriaAll : FB_AlarmFilterCriteriaAll; fbAlarmManagerClient : FB_AlarmManagerClient; itfAlarmManagerClient : IAlarmManagerClient := fbAlarmManagerClient; xAlarm1 : BOOL; xAlarm2 : BOOL; xWarning : BOOL; iNrOfAlarmsInAlarmList : INT; iNrOfActiveAlarmsInAlarmList : INT; paitfAlarm: POINTER TO ARRAY [0..0] OF AlarmManager.IAlarm; iAlarmIndex : INT; eAlarmState: AlarmManager.AlarmState; END_VAR IF xInit THEN xInit := FALSE; fbAlarmManagerClient.itfAlarmFilterCriteria := fbAlarmFilterCriteriaAll; // register alarm client to get updated about alarm status / changes udiResult := AlarmManager.g_AlarmHandler.RegisterClient(itfAlarmManagerClient, 0, 0); END_IF // Polling the number of alarms udiResult := AlarmManager.g_AlarmHandler.GetActiveAlarms(itfAlarmManagerClient, parritfActiveAlarms => paitfAlarm, iCountActiveAlarms => iNrOfAlarmsInAlarmList); iAlarmIndex := 0; iNrOfActiveAlarmsInAlarmList := 0; WHILE iAlarmIndex < iNrOfAlarmsInAlarmList DO eAlarmState := paitfAlarm^[iAlarmIndex].GetState(); IF eAlarmState = AlarmManager.AlarmState.Active OR eAlarmState = AlarmManager.AlarmState.ActiveAcknowledged THEN iNrOfActiveAlarmsInAlarmList := iNrOfActiveAlarmsInAlarmList + 1; END_IF iAlarmIndex := iAlarmIndex + 1; END_WHILE See below some details about the function blocks: One function block should implement the IAlarmFilterCriteria interface. This can be empty except a few methods. FUNCTION_BLOCK FB_AlarmFilterCriteriaAll IMPLEMENTS AlarmManager.IAlarmFilterCriteria Method implementation (others related to interface are empty) METHOD AreAllAlarmClassesSelected : BOOL AreAllAlarmClassesSelected := TRUE; METHOD AreAllAlarmGroupsSelected : BOOL AreAllAlarmGroupsSelected := TRUE; METHOD GetPriorityFrom : USINT GetPriorityFrom := 0; METHOD GetPriorityTo : USINT GetPriorityTo := 255; The other function block should implement IAlarmManagerClient and get a reference to the FB which implements the IAlarmFilterCriteria FUNCTION_BLOCK FB_AlarmManagerClient IMPLEMENTS AlarmManager.IAlarmManagerClient VAR_INPUT itfAlarmFilterCriteria: AlarmManager.IAlarmFilterCriteria; END_VAR Method implementation (others related to the interface are empty) METHOD GetFilterCriteria : AlarmManager.IAlarmFilterCriteria // see VAR_INPUT for filter GetFilterCriteria := itfAlarmFilterCriteria; Off course you have to add the AlarmManager to your application and add some alarms to it.
Last updated: 2025-09-02
Post by imdatatas on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic
CODESYS Forge
talk
(Post)
Dear @gseidel, Thank you for your clarification. I fully agree that the quadratic ramp type may have certain technical advantages. However, the main problem is backward compatibility and consistency across projects. In many automation projects, application developers rely on the fact that creating a new axis object will behave exactly the same way as in previous versions. With SoftMotion V4.18.0.0 and later, if an application developer adds an axis and overlooks the changed default, the motion function blocks behave differently than expected. In particular, since the Jerk value in SM3_Basic function blocks is ineffective in trapezoid ramp type, users are accustomed to leaving this parameter empty in their projects. In many existing projects, this variable has not even been assigned. When the default is changed to quadratic, the Jerk parameter suddenly becomes relevant, which can cause errors or unexpected behaviour in the field. From a user perspective, a default setting should always be the âsafeâ and âexpectedâ option, while alternative options (like quadratic) can be selected manually if desired. Keeping the default as trapezoid ensures compatibility with existing projects and prevents unexpected issues, while still allowing users to benefit from quadratic ramps if they explicitly choose so. For these reasons, I kindly ask you to reconsider making trapezoid the default again. This would significantly reduce the risk of unexpected behaviour in future projects while still preserving the advantages of the quadratic ramp type for those who actively select it. Of course, the final decision is entirely at your discretion. Best Regards, imdatatas
Last updated: 2025-09-26
Post by john-robinson on Limiting Memory Access of an Array to Within its Bounds
CODESYS Forge
talk
(Post)
Recently we had an issue regarding some simple code to calculate a rolling average. The code indexes from zero to 199 to properly store the current input into a circular buffer which then allows us to calculate a rolling average: VAR input_5s : REAL; outs_arr : ARRAY[0..199] OF REAL; i : USINT := 0; END_VAR ___ //this code runs every five seconds, calculating a rolling average outs_arr[i] := input_5s; i := i + 1; output := OSCAT_BASIC.ARRAY_AVG(ADR(outs_arr), SIZEOF(outs_arr)); IF i >= SIZEOF(outs_arr) THEN i := 0; END_IF There is a simple bug in this code where the index will be set to 0 when it has surpassed the length of the array in bytes (800 in this case) rather than larger than the number of reals in the array (200). The solution here is simple, replacing i >= SIZEOF(outs_arr) with i >= SIZEOF(outs_arr)/SIZEOF(outs_arr[0]). In this example when the index increased to 201 and the line outs_arr[201] := input_5s was called, codesys arbitrarily wrote to the address in memory that is where outs_arr[201] would be if the array was that long. I would like to find a way to wrap the codesys array inside of a wrapper class that checks if an input is within the bounds of an array before writing to that value. I know how I would implement that for a specific array, I could create a method or class that takes an input of an array of variable length, ie. ARRAY[*] OF REAL, but I don't know how to make this for any data type. I am wondering if anyone has ever done anything similar to this, or has any better suggestions to ensure that none of the programmers on this application accidentally create code that can arbitrarily write to other locations in memory.
Last updated: 2024-03-05
Post by anonymous on Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Post)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part.I am able to capture the data of client side in wireshark but i am unable to capture it in the codesys. Heres the below part of code of client side. PROGRAM POU_udpclient_program VAR istep : INT := 1;//step variable for state machine xStart: BOOL;// Flag to start the UDP protocol iecSocketId: syssocket_interfaces.RTS_IEC_HANDLE;//socket handle for receiving iecCreateResult: syssocket_interfaces.RTS_IEC_RESULT; ipAddr: syssocket.SOCKADDRESS;//Socket address structure for receiving sIpAddress : STRING := '192.168.0.2'; wPort: WORD:= 12346; iecConnectResult : syssocket_interfaces.RTS_IEC_RESULT;//connect paramters sDataRec : STRING[255];//Buffer for received data xiRecBytes : __XINT;//number of bytes received iecRecResult : syssocket_interfaces.RTS_IEC_RESULT;//receive data parameters iecCloseResult : syssocket_interfaces.RTS_IEC_RESULT; END_VAR syssocket.SysSockInetAddr(sIpAddress,ADR(ipAddr.sin_addr)); ipAddr.sin_family := syssocket.SOCKET_AF_INET; ipAddr.sin_port := syssocket.SysSockHtons(wPort); CASE istep OF 1: //create socket IF xStart THEN iecSocketId:= syssocket.SysSockCreate(syssocket.SOCKET_AF_INET,syssocket.SOCKET_DGRAM,syssocket.SOCKET_IPPROTO_IP,ADR(iecCreateResult)); IF iecSocketId = syssocket_interfaces.RTS_INVALID_HANDLE THEN xStart := FALSE; istep := 1; ELSE istep := 2; END_IF END_IF 2: //connect to socket server using setoption iecConnectResult := syssocket.SysSockSetOption(iecSocketId,syssocket.SOCKET_SOL,syssocket.SOCKET_SO_REUSEADDR,ADR(ipAddr),SIZEOF(ipAddr)); istep := 3; 3: //receive data xiRecBytes := syssocket.SysSockRecvFrom(iecSocketId,ADR(sDataRec),SIZEOF(sDataRec),0,ADR(ipAddr),SIZEOF(ipAddr),ADR(iecRecResult)); istep := 4; 4: //close socket iecCloseResult:= syssocket.SysSockClose(iecSocketId); xStart := FALSE; istep := 1; END_CASE
Last updated: 2024-06-03
Post by munwar on Temu Coupon Code |^â˘^100% off^â˘^| [^â˘^ââ â {acq794628^â˘^] for New and Existing Customers.
CODESYS Forge
talk
(Post)
ready to elevate your shopping experience with Temu's incredible offers! Use our exclusive Temu coupon code $100 off [acq794628] for existing customers or for new users to enjoy massive savings on your next purchase. Temu: Your Gateway to Unbeatable Deals Temu has taken the e-commerce world by storm, offering a vast array of products at jaw-dropping prices. With free shipping to 67 countries and lightning-fast delivery, it's no wonder Temu has become a go-to destination for savvy shoppers. . But the savings don't stop there â let's explore how you can maximize your discounts with our Temu coupon $100 off for existing customers! Exclusive Temu Coupon Codes for Maximum Savings Here's a quick rundown of our top Temu coupon codes: ⢠acq794628: Temu coupon code $100 off for new users ⢠acq794628: Temu coupon $100 off for customers ⢠acq794628: Temu $100 extra off (Temu 100$ coupon code) ⢠acq794628: $100 discount for new users (100 off Temu coupon) ⢠acq794628: $100 coupon for existing and new users (Temu coupon code 100 off) Why Choose Temu? Before we dive deeper into the Temu $100 coupon bundle, let's look at what makes Temu stand out: 1. Vast product selection 2. Unbeatable prices 3. Fast and free shipping 4. User-friendly platform 5. Regular promotions and discounts How to Use Your Temu Coupon Code $100 Off Using your Temu coupon code $100 off is a breeze. Here's a step-by-step guide to help you make the most of your savings: 1. Browse Temu's extensive catalog 2. Add items to your cart 3. Proceed to checkout 4. Enter your Temu coupon code $100 off in the designated field 5. Watch your total drop by $100! Tips for Maximizing Your Savings To get the most bang for your buck,. consider these strategies: 1. Combine your Temu coupon $100 off with ongoing sales 2. Look for bundle deals to increase your savings 3. Check Temu's daily deals for additional discounts 4. Sign up for Temu's newsletter to stay informed about upcoming promotions Temu Coupon $100 Off: Frequently Asked Questions You might be wondering about the details of these incredible offers. Let's address some common questions: Is the Temu $100 off coupon legit? Absolutely! The Temu 100 off coupon is legit and has been verified by countless happy customers. You can shop with confidence knowing that your Temu coupon code $100 off will be honored at checkout. Can I use the Temu coupon $100 off for existing customers on my first order? While the Temu coupon $100 off for existing customers is designed for repeat shoppers, new users can take advantage of the Temu coupon code $100 off for new users. Both offers provide the same great savings! How often can I use a Temu coupon $100 off? Typically, these coupons are one-time use per account. However, Temu frequently releases new promotions, so keep an eye out for fresh opportunities to save! Explore Temu's Best Deals with Your $100 Off Coupon Now that you're armed with your Temu coupon code $100 off, let's look at some popular categories where you can apply your savings: ⢠Electronics ⢠Fashion ⢠Home & Garden ⢠Beauty & Personal Care ⢠Sports & Outdoors Hot Deals Alert: Temu Coupon Codes Don't miss out on these amazing offers: ⢠acq794628: Temu coupon $100 off for existing customers free shipping ⢠acq794628: Temu coupon $100 off for new users ⢠acq794628: Temu coupon codes 100 off ⢠acq794628: Temu coupon $100 off code ⢠acq794628: Temu coupon $100 off first-time user Make the Most of Your Temu Shopping Experience As you explore Temu's vast catalog with your Temu coupon $100 off in hand, keep these tips in mind: 1. Read product reviews from other customers 2. Check sizing charts for clothing and shoes 3. Compare similar items to find the best value 4. Take advantage of Temu's customer service for any questions The Temu Difference What sets Temu apart from other e-commerce platforms? It's not just about the Temu $100 coupon bundle â it's the overall shopping experience. With a user-friendly interface, a wide range of products, and unbeatable prices, Temu is revolutionizing online shopping. I've been using Temu for months now, and I can confidently say that the savings are real. Whether you're a new user looking to score a great deal with a Temu coupon code $100 off first order or an existing customer ready to use your Temu coupon $100 off for existing customers first order, you're in for a treat. Conclusion: Shop Smart with Temu In today's economy, finding ways to save money without sacrificing quality is crucial. That's why I'm thrilled to share these Temu coupon $100 off opportunities with you. Whether you're shopping for yourself or looking for the perfect gift, Temu has you covered. Remember, the key to maximizing your savings is to stay informed about the latest promotions. Bookmark this page and check back regularly for updates on Temu coupon codes and deals. And don't forget â your Temu coupon code $100 off [acq794628] for existing customers is waiting to be used! Happy shopping, and enjoy your incredible savings with Temu! .
Last updated: 2024-10-26
Post by munwar on Temu coupon code â ââ â {acq794628}: ||^°$100 off.^° ||
CODESYS Forge
talk
(Post)
ready to elevate your shopping experience with Temu's incredible offers! Use our exclusive Temu coupon code $100 off [acq794628] for existing customers or for new users to enjoy massive savings on your next purchase. Temu: Your Gateway to Unbeatable Deals Temu has taken the e-commerce world by storm, offering a vast array of products at jaw-dropping prices. With free shipping to 67 countries and lightning-fast delivery, it's no wonder Temu has become a go-to destination for savvy shoppers. . But the savings don't stop there â let's explore how you can maximize your discounts with our Temu coupon $100 off for existing customers! Exclusive Temu Coupon Codes for Maximum Savings Here's a quick rundown of our top Temu coupon codes: ⢠acq794628: Temu coupon code $100 off for new users ⢠acq794628: Temu coupon $100 off for customers ⢠acq794628: Temu $100 extra off (Temu 100$ coupon code) ⢠acq794628: $100 discount for new users (100 off Temu coupon) ⢠acq794628: $100 coupon for existing and new users (Temu coupon code 100 off) Why Choose Temu? Before we dive deeper into the Temu $100 coupon bundle, let's look at what makes Temu stand out: 1. Vast product selection 2. Unbeatable prices 3. Fast and free shipping 4. User-friendly platform 5. Regular promotions and discounts How to Use Your Temu Coupon Code $100 Off Using your Temu coupon code $100 off is a breeze. Here's a step-by-step guide to help you make the most of your savings: 1. Browse Temu's extensive catalog 2. Add items to your cart 3. Proceed to checkout 4. Enter your Temu coupon code $100 off in the designated field 5. Watch your total drop by $100! Tips for Maximizing Your Savings To get the most bang for your buck,. consider these strategies: 1. Combine your Temu coupon $100 off with ongoing sales 2. Look for bundle deals to increase your savings 3. Check Temu's daily deals for additional discounts 4. Sign up for Temu's newsletter to stay informed about upcoming promotions Temu Coupon $100 Off: Frequently Asked Questions You might be wondering about the details of these incredible offers. Let's address some common questions: Is the Temu $100 off coupon legit? Absolutely! The Temu 100 off coupon is legit and has been verified by countless happy customers. You can shop with confidence knowing that your Temu coupon code $100 off will be honored at checkout. Can I use the Temu coupon $100 off for existing customers on my first order? While the Temu coupon $100 off for existing customers is designed for repeat shoppers, new users can take advantage of the Temu coupon code $100 off for new users. Both offers provide the same great savings! How often can I use a Temu coupon $100 off? Typically, these coupons are one-time use per account. However, Temu frequently releases new promotions, so keep an eye out for fresh opportunities to save! Explore Temu's Best Deals with Your $100 Off Coupon Now that you're armed with your Temu coupon code $100 off, let's look at some popular categories where you can apply your savings: ⢠Electronics ⢠Fashion ⢠Home & Garden ⢠Beauty & Personal Care ⢠Sports & Outdoors Hot Deals Alert: Temu Coupon Codes Don't miss out on these amazing offers: ⢠acq794628: Temu coupon $100 off for existing customers free shipping ⢠acq794628: Temu coupon $100 off for new users ⢠acq794628: Temu coupon codes 100 off ⢠acq794628: Temu coupon $100 off code ⢠acq794628: Temu coupon $100 off first-time user Make the Most of Your Temu Shopping Experience As you explore Temu's vast catalog with your Temu coupon $100 off in hand, keep these tips in mind: 1. Read product reviews from other customers 2. Check sizing charts for clothing and shoes 3. Compare similar items to find the best value 4. Take advantage of Temu's customer service for any questions The Temu Difference What sets Temu apart from other e-commerce platforms? It's not just about the Temu $100 coupon bundle â it's the overall shopping experience. With a user-friendly interface, a wide range of products, and unbeatable prices, Temu is revolutionizing online shopping. I've been using Temu for months now, and I can confidently say that the savings are real. Whether you're a new user looking to score a great deal with a Temu coupon code $100 off first order or an existing customer ready to use your Temu coupon $100 off for existing customers first order, you're in for a treat. Conclusion: Shop Smart with Temu In today's economy, finding ways to save money without sacrificing quality is crucial. That's why I'm thrilled to share these Temu coupon $100 off opportunities with you. Whether you're shopping for yourself or looking for the perfect gift, Temu has you covered. Remember, the key to maximizing your savings is to stay informed about the latest promotions. Bookmark this page and check back regularly for updates on Temu coupon codes and deals. And don't forget â your Temu coupon code $100 off [acq794628] for existing customers is waiting to be used! Happy shopping, and enjoy your incredible savings with Temu! .
Last updated: 2024-10-26
Post by fukre on Temu Coupon Code â{" acq794628."}: |Get "$100 off" + 30% Discount|
CODESYS Forge
talk
(Post)
Ready to elevate your shopping experience with Temu's incredible offers! Use our exclusive Temu coupon code $100 off [acq794628] for existing customers or for new users to enjoy massive savings on your next purchase. Temu: Your Gateway to Unbeatable Deals Temu has taken the e-commerce world by storm, offering a vast array of products at jaw-dropping prices. With free shipping to 67 countries and lightning-fast delivery, it's no wonder Temu has become a go-to destination for savvy shoppers. . But the savings don't stop there â let's explore how you can maximize your discounts with our Temu coupon $100 off for existing customers! Exclusive Temu Coupon Codes for Maximum Savings Here's a quick rundown of our top Temu coupon codes: ⢠acq794628: Temu coupon code $100 off for new users ⢠acq794628: Temu coupon $100 off for customers ⢠acq794628: Temu $100 extra off (Temu 100$ coupon code) ⢠acq794628: $100 discount for new users (100 off Temu coupon) ⢠acq794628: $100 coupon for existing and new users (Temu coupon code 100 off) Why Choose Temu? Before we dive deeper into the Temu $100 coupon bundle, let's look at what makes Temu stand out: 1. Vast product selection 2. Unbeatable prices 3. Fast and free shipping 4. User-friendly platform 5. Regular promotions and discounts How to Use Your Temu Coupon Code $100 Off Using your Temu coupon code $100 off is a breeze. Here's a step-by-step guide to help you make the most of your savings: 1. Browse Temu's extensive catalog 2. Add items to your cart 3. Proceed to checkout 4. Enter your Temu coupon code $100 off in the designated field 5. Watch your total drop by $100! Tips for Maximizing Your Savings To get the most bang for your buck,. consider these strategies: 1. Combine your Temu coupon $100 off with ongoing sales 2. Look for bundle deals to increase your savings 3. Check Temu's daily deals for additional discounts 4. Sign up for Temu's newsletter to stay informed about upcoming promotions Temu Coupon $100 Off: Frequently Asked Questions You might be wondering about the details of these incredible offers. Let's address some common questions: Is the Temu $100 off coupon legit? Absolutely! The Temu 100 off coupon is legit and has been verified by countless happy customers. You can shop with confidence knowing that your Temu coupon code $100 off will be honored at checkout. Can I use the Temu coupon $100 off for existing customers on my first order? While the Temu coupon $100 off for existing customers is designed for repeat shoppers, new users can take advantage of the Temu coupon code $100 off for new users. Both offers provide the same great savings! How often can I use a Temu coupon $100 off? Typically, these coupons are one-time use per account. However, Temu frequently releases new promotions, so keep an eye out for fresh opportunities to save! Explore Temu's Best Deals with Your $100 Off Coupon Now that you're armed with your Temu coupon code $100 off, let's look at some popular categories where you can apply your savings: ⢠Electronics ⢠Fashion ⢠Home & Garden ⢠Beauty & Personal Care ⢠Sports & Outdoors Hot Deals Alert: Temu Coupon Codes Don't miss out on these amazing offers: ⢠acq794628: Temu coupon $100 off for existing customers free shipping ⢠acq794628: Temu coupon $100 off for new users ⢠acq794628: Temu coupon codes 100 off ⢠acq794628: Temu coupon $100 off code ⢠acq794628: Temu coupon $100 off first-time user Make the Most of Your Temu Shopping Experience As you explore Temu's vast catalog with your Temu coupon $100 off in hand, keep these tips in mind: 1. Read product reviews from other customers 2. Check sizing charts for clothing and shoes 3. Compare similar items to find the best value 4. Take advantage of Temu's customer service for any questions The Temu Difference What sets Temu apart from other e-commerce platforms? It's not just about the Temu $100 coupon bundle â it's the overall shopping experience. With a user-friendly interface, a wide range of products, and unbeatable prices, Temu is revolutionizing online shopping. I've been using Temu for months now, and I can confidently say that the savings are real. Whether you're a new user looking to score a great deal with a Temu coupon code $100 off first order or an existing customer ready to use your Temu coupon $100 off for existing customers first order, you're in for a treat. Conclusion: Shop Smart with Temu In today's economy, finding ways to save money without sacrificing quality is crucial. That's why I'm thrilled to share these Temu coupon $100 off opportunities with you. Whether you're shopping for yourself or looking for the perfect gift, Temu has you covered. Remember, the key to maximizing your savings is to stay informed about the latest promotions. Bookmark this page and check back regularly for updates on Temu coupon codes and deals. And don't forget â your Temu coupon code $100 off [acq794628] for existing customers is waiting to be used! Happy shopping, and enjoy your incredible savings with Temu! .
Last updated: 2024-10-26
Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
In reality, other vendors are already moving towards integration with VS Code. B&R, for example, is likely the only one that could truly challenge Codesys in the market: theyâve overhauled their once-archaic environment (previously lacking ST OOP) and are now catching up significantly with Automation Studio Code, offering modern programming capabilities and native support for tools like Git and GitHub Copilot. The other big names in the market, frankly, are still light years behind. For smaller projects, typically handled by âwire strippersâ (with all due respect!), a classic environment might be just fine. But once youâre dealing with thousands or even millions of lines of codeâpossibly organized in an OOP paradigm, spanning large teams, integrating third-party libraries, requiring version control, and performing comprehensive testsâa lightweight, responsive editor supercharged with AI-based features becomes essential. The real strength of something like VS Code lies in its vast ecosystem of extensions and integrations: from advanced Git support to automated build/test pipelines, and even AI-assisted autocompletion that already makes software development much more agile and productive. I understand that a PLC project involves more than just ST code (task setup, fieldbus configuration, libraries, etc.). However, thereâs no technical reason not to at least provide ST files in a pure text format, making version control and collaboration far easier. B&R has clearly adopted this approach; I hope Codesys will accelerate its own efforts to offer a native, text-based integration and modern development tooling. Once you go beyond a certain level of complexityâdozens of configurations, OOP hierarchies, and distributed teamsâyou really do need âengineer-levelâ software tools, not just solutions targeting âwire strippers.â For large-scale automation projects, a more open and flexible approach is the only way to avoid chronic frustration. Let me emphasize that I truly love Codesys and consider the work done so far to be brilliantâIâd be sorry to see it overshadowed by others moving faster in this direction.
Last updated: 2025-02-18
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14
Post by mariapaola on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3
CODESYS Forge
talk
(Post)
Hi, Would really appreciate your insights in this issue I have. I am currently using a WAGO 750-881 with multiple IO devices. For one of them I already occupied the MODBUS Master configuration tool so I cannot overwrite it for my other devices. I have a total of two serial interfaces WAGO 750-652. The first one is instantiated in COM2 and doesn't need any protocol since the information comes in an specific formatting that need little code to differentiate between needed info. This one is working just fine. The second one is where I have an issue. I have tried to instantiate the port using MODBUS library modb_L05.lib to properly receive the data from an ARDUINO and I am absolutely unable to open the port: Signal DEVICE2.fbModbus.MODBUS_EXT_MASTER.Interface.Com_Port_Ist_Offen is never TRUE, among with all other signals from that interface, while signal DEVICE1.COM2.Com_Port_Ist_Offen is TRUE, and the other signals also read as TRUE or FALSE. I have tried instantiating the second one as the first one, changing COM3 to COM4, I've tried a lot of things but it wont ever open the channel. I don't know if you have any recommendations for me. For both physical modules, both witness LEDs A and E are on. First one is instantiated like this: PROGRAM DEVICE1 VAR wBaudRate : WORD := BAUD_9600; bDataBits : BYTE := 8; bParity : BYTE := 0; bFlowControl : BYTE := 3; (RS422 FullDuplex with continous send) i : INT; COM2 : SERIAL_INTERFACE; xOpenPort2 : BOOL := TRUE; ( Flag to open the Port ) xInitPort2 : BOOL; ( Flag to initiallize the Port ) ReceiveBuffer2 : typRing_Buffer; END_VAR COM2( bCOM_PORT_NR := 2, cbBAUDRATE := wBaudRate, cbsBYTESIZE := bDataBits, cpPARITY := bParity, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := bFlowControl, utRECEIVE_BUFFER := ReceiveBuffer2, ptSEND_BUFFER := ADR(SendString2), xINIT := xInitPort2, xOPEN_COM_PORT := xOpenPort2, iBYTES_TO_SEND := LEN(SendString2)+1, xSTART_SEND := xSendActive2 ); Second one like this: PROGRAM DEVICE2 VAR COM4 : SERIAL_INTERFACE; xInitPort4 : BOOL := TRUE; xOpenPort4 : BOOL := TRUE; ReceiveBuffer4 : typRing_Buffer; fbModbus : MODBUS_EXTENDED_MASTER_RTU; fbError : enumMB_ERROR; stQuery : typModbusExtendedQuery; stResponse : typModbusResponse; au16Data : ARRAY[0..14] OF WORD; i : INT; tPoll : TON; END_VAR COM4( bCOM_PORT_NR := 4, cbBAUDRATE := BAUD_9600, cbsBYTESIZE := 8, cpPARITY := 0, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := 2, ( RS-485 half-duplex ) utRECEIVE_BUFFER := ReceiveBuffer4, xINIT := xInitPort4, xOPEN_COM_PORT := xOpenPort4, xSTART_SEND := xSendActive4, ); stQuery.SlaveAddress := 1; stQuery.FunctionCode := 3; stQuery.Read_StartAddress := 0; stQuery.Read_Quantity := 15; (Poll code) fbModbus( ENABLE := TRUE, bCOM_PORT := 4, ( COM4=> 750-652 port ) cbCOM_BAUDRATE := BAUD_9600, cpCOM_PARITY := 0, csCOM_STOPBITS := 1, cbsCOM_BYTESIZE := 8, cfCOM_FLOW_CONTROL := 2, TimeOut := T#500ms, StartFunction := xStart, ExtQuery := stQuery, Response := stResponse, MB_Error => fbError ); FOR i := 0 TO 14 DO au16Data[i] := stResponse.Data[i]; END_FOR;
Last updated: 2025-11-28
Post by bertus on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hello all, I am trying to run a XY trajectory from a static G-Code file. Everything works except the smoothing/blending of the corners. My setup: Codesys v3.5sp18 Raspberry Pi 4 CODESYS Control for Raspberry Pi SL, using demo license. Zero axes (only using the interpolator). The order of processing for my decoding is: SMC_NCDecoder (ok) SMC_SmoothMerge (ok) SMC_SmoothPath (not ok) SMC_LimitDynamics SMC_CheckVelocities I created following instances and buffers: fbNCDecoder: SMC_NCDecoder; fbSmoothMerge: SMC_SmoothMerge; fbSmoothPath: SMC_SmoothPath; fbLimitDynamics: SMC_LimitDynamics; fbCheckVelocities: SMC_CheckVelocities; aNCDecoderBuffer: ARRAY[0..49] OF SMC_GeoInfo; // buffer stage 1 (fbNCDecoder) aSmoothMergeBuffer: ARRAY[0..19] OF SMC_GeoInfo; // buffer stage 2 (fbSmoothMerge) aSmoothPathBuffer: ARRAY[0..99] OF SMC_GeoInfo; // buffer stage 3 (fbSmoothPath) aLimitDynamicsBuffer: ARRAY[0..39] OF SMC_GeoInfo; // buffer stage 4 (fbLimitDynamics) My original G-Code file has a lot of short G1 elements but this example, I reduced it to a simple square: N000 G51 D10 N010 G38 O1 N020 G00 X0 Y0 F50 E1000 E-1000 N030 G01 X0 Y-37.5 N040 G01 X-75 Y-37.5 N050 G01 X-75 Y37.5 N060 G01 X0 Y37.5 N070 G01 X0 Y0 N080 G50 N090 G39 O1 In the Codesys CNC settings, I have these instances activated: SMC_SmoothMerge SMC_SmoothPath SMC_LimitDynamics SMC_CheckVelocities And with those settings (and the path-preprocessing button actived), the G-Code viewer shows the square with nicely blended corners (see attached picture). However, when running it on the PLC, it doesn't blend the corners at all. Below the relevant part of my code. The process is started with bDecode. // stage 1: decoding G-code fbNCDecoder( ncprog := square, bExecute:= bDecode, bAbort:= NOT bDecode, nSizeOutQueue := SIZEOF(aNCDecoderBuffer), pbyBufferOutQueue := ADR(aNCDecoderBuffer) ); // stage 2: merge short linear segments fbSmoothMerge( bExecute := bDecode, poqDataIn := fbNCDecoder.poqDataOut, nSizeOutQueue := SIZEOF(aSmoothMergeBuffer), pbyBufferOutQueue := ADR(aSmoothMergeBuffer), piMaxDifference := PI_MAX_DIFFERENCE, usiMaxDegree := 5, wFeatureFlag := 1, wAdditionalParamNumber := 0, dMinimumCurvatureRadius := D_MIN_CURVATURE_RADIUS ); // stage 3: smooth corners fbSmoothPath( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothMerge.poqDataOut, eMode := SMC_SMOOTHPATHMODE.SP_SPLINE5_MIN_CURVATURE, eAddAxMode := SMC_SMOOTHPATHADDAXMODE.SPAA_NONE, nSizeOutQueue := SIZEOF(aSmoothPathBuffer), pbyBufferOutQueue := ADR(aSmoothPathBuffer), dAngleTol := D_ANGLE_TOL, bSymmetricalDistances := TRUE, bImprovedSymmetricCuts := TRUE ); // stage 4: keep acc/dec and velocity within limits fbLimitDynamics( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothPath.poqDataOut, wAxis := 16#07, nSizeOutQueue := SIZEOF(aLimitDynamicsBuffer), pbyBufferOutQueue := ADR(aLimitDynamicsBuffer), bIncludePathSettings := TRUE, dMaxVel := 2500, dMaxAccDec := 10000 ); // stage 5: check the path speed fbCheckVelocities( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbLimitDynamics.poqDataOut, dAngleTol := D_ANGLE_TOL); pathQueue := fbCheckVelocities.poqDataOut; // repeat until MaxDuration ... Any idea what I'm doing wrong? Is smooth path supposed to work at all when using a demo license? Thanks.
Last updated: 2 days ago
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by shooxplc on How to call the same program from library and get the vars updated.
CODESYS Forge
talk
(Post)
Hi, I am writing to you today because I would like to create a library that would contain a program with its various subprograms, in my example "PLC_PRG" with "a", "aa", "aaa". But once the library is created as shown below: I would like to be able to drag and drop my folder as many times as I want (let's say I manage the same system multiple times). Once the drag and drop is done, we can see the second folder with the variables renamed successfully. As shown below: But my variables in CAD_1 remain the same as for CAD, so it's PLC_PRG instead of PLC_PRG_1, for example. Is there a solution to automate this? I wouldn't want to have to rename all my variables manually, considering that in the program where I want to do this, the number of variables is substantial. Lucas.
Last updated: 2023-08-23
Post by timvh on Detect "Cancel" Press in FileOpenSave Dialog
CODESYS Forge
talk
(Post)
Maybe there is a better way, but a long time ago I created a test application that worked like this: With a button I opened the dialog and I added a "Input configuration - OnDialogClosed" "Execute ST-Code" action to this same button which called the following Function when the dialog was closed: F_OnFileDialogClosed(pClientData); Below this Function which handled the result: // This function is called from the visualization when the dialog is closed. FUNCTION F_OnFileDialogClosed : BOOL VAR_INPUT pClientData : POINTER TO VisuElems.VisuStructClientData; END_VAR VAR dialogMan : VisuElems.IDialogManager; FileOpenCloseDialog : VisuElems.IVisualisationDialog; result : VisuElems.Visu_DialogResult; _sFileName : STRING(255); END_VAR // the DialogManager is provided via the implicitly available VisuManager dialogMan := VisuElems.g_VisuManager.GetDialogManager(); IF dialogMan <> 0 AND pClientData <> 0 THEN FileOpenCloseDialog := dialogMan.GetDialog('VisuDialogs.FileOpenSave'); // gets the FileOpenSave dialog IF FileOpenCloseDialog <> 0 THEN result := FileOpenCloseDialog.GetResult(); // gets the result (OK, Cancel) of the dialog IF result = VisuElems.Visu_DialogResult.OK THEN // Original code gvlFile.FileListProvider(); _sFileName := CONCAT(gvlFile.FileListProvider._stDirectory, gvlFile.FileListProvider.stFile); // do something with this file name... END_IF END_IF END_IF
Last updated: 2023-09-19
Post by damian177 on Codesys and SMS in RPi
CODESYS Forge
talk
(Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?
Last updated: 2023-09-29
Post by ryusoup on JSONByteArrayWriter problem?
CODESYS Forge
talk
(Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,
Last updated: 2023-10-04
Post by captaincookie on increase default string length in queue
CODESYS Forge
talk
(Post)
Hello, I'm using Codesys V3.5 SP18 Patch 4. In the ElementCollectionExample Project from Codesys, I test the SimpleQueueExample in a Control Win V3 x64 environment. I try to add a string of 95 characters length to a queue. The default length of strings is defined as 80 characters. In the initialization of a string variable, it is possible to increase the length by the definition of e.g. STRING(1000). But when I write the string defined like this to the queue, only 80 characters are written to it and the rest is missing. I think the default length is still set in the queue definition, so it is necessary to change this, isn't it? Is there any option to increase the default length of strings in the queue? Attached you can find the used project. Thanks in advance. If any information are missing or my description unclear please let me know.
Last updated: 2023-10-05
Post by markusef3 on Verhalten bei zu kurz gesetzter Task-Zyklus-Zeit
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe eine Frage bezĂźglich dem Verhalten der Tasks. In der Hilfe und hier im Forum sowei im Internet konnte ich diesbezĂźglich leider nichts finden. Wie genau verhält sich Codesys wenn mehrere zyklische Task eingestellt sind und bei einem ab und zu die Abarbeitung des angehängten Programmes länger dauert als das Aufrufintervall eingestellt ist. D.H. der nächste Aufruf wĂźrde "theoretisch" erfolgen bevor alles im Program abgearbeitet ist. Z.B. Intervall ist 1ms, Abarbeitung dauert manchmel 1,1ms oder länger. (Watchdog ist zwar eingeschaltet, aber grĂśĂer gewählt als das Zyklische Intervall zum Aufruf. Watchdog soll jetzt auch nicht das Thema sein). Was passiert in so einem Fall? - Wird das Programm zuerst zu Ende abgearbeitet und dann der nächste Aufruf gestartet? - Wird das Programm "mittendrin" unterbrochen und dann neu gestartet? - wie genau muss ich mir das vorstellen wenn dem so ist? - ...... - ...... Ich konnte Ăźberall nur Anleitungen finden wie die Tasks zu konfigurieren sind, jedoch nichts dazu was im oben genannten Fall genau passieren wird. Gruss Markus
Last updated: 2023-10-19
Post by janber0206 on Gateway doesn't come online, regarding a working internet connection
CODESYS Forge
talk
(Post)
Solved EN: The Problem is that the Codesys Edge-Gateways have a License with a runtime of an half year, as long the Gateways are online they will self renew themselfs. In my Case the RevPi was more than a year offline and so the Edge-Gateway was not working anymore. The solution: I accessed a laptop that was directly connected to the RevPi. I installed the Codesys service tool and renewed the certificate manual. DE: Das Propblem ist das die Codesys Edge-Gatways eine Lizenz haben die nur ein halbes Jahr gĂźltig ist. Solange das Gateway eine Internet verbindung hat aktualisiert sich das Zertifikat von alleine. In meinem Fall war das Gateway aber Ăźber ein Jahr offline und hat somit nicht mehr funktioniert. Die LĂśsung: Ich hab auf einen Laptop von Kunden mit TeamViewer zugegriffen, der Laptop wurde mit Kabel direkt mit RevPi verbunden. Codesys Service Tool installiert und dann das Gatewayzertifikat aktualisiert.
Last updated: 2023-10-26
Post by riccardo on VisuElems.CurrentUserGroupId is not stable
CODESYS Forge
talk
(Post)
GoodMorning everyone. I have a system that, in case of alarm, have to block. When the operator logs in must have to acknoledge the alarm and should operate in the system freely. To perform this I detect the logged User by (VisuElems.CurrentUserGroupID <> 0) with a similar code to the the following: PROGRAM AlarmMngt VAR alarm : BOOL:= FALSE; Ack : BOOL:= TRUE; PushBottonOpening : BOOL:= FALSE; Valve : BOOL := FALSE; Flag: BOOL := FALSE; END_VAR IF alarm AND Ack AND (NOT Flag) THEN valve := FALSE; PushBottonOpening := FALSE; Ack := FALSE flag := TRUE; ELSIF (NOT alarm) AND Ack THEN flag := FALSE; END_IF (* if the system is in alarm but there is a logged operator that acknowledge the alarm the system allows the valve opening.*) IF (VisuElems.CurrentUserGroupID <> 0) AND Ack AND Alarm AND PushBottonOpening THEN Valve := TRUE; ELSIF (VisuElems.CurrentUserGroupID = 0) AND Alarm THEN valve := FALSE; END_IF The problem I have is in the last 5 lines of the code: Even if there is a logged in user, the GroupID variable is subjected to a refresh that cyclically set for an instant it to 0 and this close the valve making difficult to the user to work Now I solved it creating a time hysteresys cycle but it is not a good solution. Someone is able to explane me why the GroupID variable is sobjected to this refresh and how to stabilize to avoiding it? Thank you in advance, Riccardo
Last updated: 2023-11-10
Post by mm-sceg on Runtime geht sporadisch in StĂśrung -> RaspiPi4 reagiert nicht mehr
CODESYS Forge
talk
(Post)
Guten Tag, ich hab seit längerem das Problem, dass mein Raspberry Pi4 durch die PLC in StÜrung geht. Auf dem Raspi läuft eine einfache Software mit OPC UA server, InfluxDB und ein NodeRed-Server. (Und MQTT-Server) Daten werden von der PLC ßber OPC-UA an NodeRed ßbergeben. Es kann sein, dass der Raspi 2 Wochen läuft, dann geht die PLC in Stopp. Manchmal nur 2-3 Tage. Ein Neustart ßber Spannung aus & wieder an schafft Abhilfe. NodeRed wirft extrem viele Fehlermeldungen in kurzer Zeit. Wenn die PLC in StÜrung ist, kann man sich nicht mal mehr ßber SSH beim Raspi einloggen. Der Raspi ist aktiv gekßhlt und im Normalbetrieb nicht ßberlastet. Ich hab einige logfiles mit vielen Einträgen die mir nichts sagen, eventuell hat hier jemand eine Idee wie ich dem Problem Herr werden kann :) Der letzte Datenbankeintrag von der SPS war am 11.11.2023 um 5:55:50 Uhr. D.h. danach muss die SPS gestorben sein. Siehe Raspi-Log im Anhang. Das LogFile von Codesys startet leider erst um 11 Uhr, weshalb weià ich leider nicht. Vielen Dank schonmal
Last updated: 2023-11-11
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.