Post by wiresplus on INT_TO_WORD function not working CODESYS Forge talk (Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26

Post by ojz0r on INT_TO_WORD function not working CODESYS Forge talk (Post)
That calculation will not work the way you expect it to. If PumpFillSpeed is limitied to 0-50 then the only whole number would be 50/50 = 1 everything else is 0.0-0.9999... and since you are using word and integer only 50 would work since there is no representation for mantissa in integer values. Declare a temporary real variable and do the calculation and then do a REAL_TO_WORD in the DRV2Speed assignment.
Last updated: 2024-01-26

Post by hsmw-wolf on How to fix Codesys Simulation Exception ? CODESYS Forge talk (Post)
Did anybody have a solution for this problem? I have the same issue and it occured as i wanted to continue work after the weekend. On Friday the simulation was working fine and on Monday thise error appears. There should be a more specific fault description to be honest. As I am writing I try to repair the installation and hope, that this will work. Still I am frustrated, because I don't know where to look for eliminating this fault. I am using CODESYS 3.5 SP19 Patch 5.
Last updated: 2024-01-29

Post by thomasrohnerch on Color Change for Symbols not working CODESYS Forge talk (Post)
I have some Symbols from the Visualization Toolbox on my Target Visu on the Computer. I tried many Symbols, mainly Arrows. I'm able to control the visibility with condition e.g. "GVL.actual_testvalues.speed <= 0" But I can't do "Toggle color" with boolean GVL.b_toggle_color. Neither "TRUE" nor "FALSE" does change anything. Is this a known issue? I'm using CODESYS V3.5 SP19 Patch 5 + (64-bit). See attached file with more Version-Info. I'm currently using Style 6, Gradient axial 2, 3.5.12.0. I had the same issue with Default 3.5.16.0.
Last updated: 2024-02-08

Post by durstloescher on Codesys Input Detector CODESYS Forge talk (Post)
Good morning, I am currently working on implementing a display dimmer. I want the display to dim after X minutes. This works so far. The implementation is done via the Linux subsystem, to which a command is sent to dim the display. However, my problem is resetting the timer when input is received. I want the dimming timer to be reset with each click/touch. Unfortunately, I can't find a suitable solution for this. Are there any ways to do this? Codesys v3.5 SP19 Patch 2
Last updated: 2024-02-15

Post by niallel on How to change bHiresMode CODESYS Forge talk (Post)
Hi, I'm trying to get Scaling working on my axis. An increment produces 36.6mm of movement, so I want to put the units in application as 36.6. However the docs say that I need to change bHiresMode as it doesn't show me the option for Precision in the User Interface. I'm thinking that I need to change the precision so I can enter decimal places. How can I do this, or is my thinking wrong? Thanks,
Last updated: 2024-03-11

Post by gregorpl on Tosibox With EATON XV300 CODESYS Forge talk (Post)
HEllo, I need to connect with PLC XV300 , the problem is for me not simple. The PLC have remote control by Tosibox VPN tunel. I can see the screen from PLC, but i also want to se Input and Output the PLC . I try to scan the network by useing tosibox Gateway but its not working. Where i should looking the problem ? DO i need added special library ?
Last updated: 2024-03-12

Post by k4zz on Scripting static code analysis CODESYS Forge talk (Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18

Post by wind-11 on Problem with simulation Modbus CODESYS Forge talk (Post)
Hello everyone, I encountered a problem in the simulation while working. In a test project we set up a Modbus connection. We wanted to simulate this with test values. The connection also worked, but unfortunately the values are frozen and do not report any β€œcurrent data”. (Picture attached) Since these are my first points of contact with Codesys and my colleague continues to work elsewhere, I was hoping that someone here might have an idea. Kind regards and thanks in advance.
Last updated: 2024-03-22

Post by sachem on SysFileGetTime problem CODESYS Forge talk (Post)
Good morning. I'm working with a Weidmuller controller using Codesys. My project use OPC-UA to communicate an application in my pc with the controller. Yesterday, I installed the license of the controller and test it, and the communication works perfect. I use the communication with anonymous login, and works fine. But, hours later, the anonymous login don't work, and the controller only allows connection via OPC with username and password. Someone know why this happend? Thanks
Last updated: 2024-04-09

Post by yannick on Raspberry PI 5 not working CODESYS Forge talk (Post)
Hello I'm using Codesys V3.5 SP19 Patch 6 and a Raspberry PI 5 4GB Bookworm 32bit with the Runtime 4.11.0.0 SL. I can install the runtime and download the software completly but after a few seconds the connection disconnects with the message no connection to device. Please scan network again. And the object reference was not set to an object instance. See screenshot. Can somebody help me with that? Thanks
Last updated: 2024-04-28

Post by eschwellinger on Raspberry PI 5 not working CODESYS Forge talk (Post)
there is a new problem with latest bootloader version. The problem seems to be: Version from2024-04-20 does not work-> 2024-01-15 version works the workaround is a rollback to January version: cp /lib/firmware/raspberrypi/bootloader-2712/stable/pieeprom-2024-01-15.bin ./pieeprom.bin rpi-eeprom-config pieeprom.bin > bootconf.txt rpi-eeprom-config --out pieeprom-new.bin --config bootconf.txt pieeprom.bin sudo rpi-eeprom-update -d -f ./pieeprom-new.bin sudo reboot
Last updated: 2024-04-29

Post by yofi on Raspberry Pi 4 POU not running CODESYS Forge talk (Post)
I have this error where the pou doesn't run even for simple programs like contact and a coil if i remove the pou from the task and put another one it works for one run then it stops working again in the photo we can see a contact is on but the coil connected to it is still not on and the device is in run mode I had this issue again and again any help
Last updated: 2024-06-02

Post by yofi on Raspberry Pi 4 POU not running CODESYS Forge talk (Post)
I have this error where the pou doesn't run even for simple programs like contact and a coil if i remove the pou from the task and put another one it works for one run then it stops working again in the photo we can see a contact is on but the coil connected to it is still not on and the device is in run mode I had this issue again and again any help
Last updated: 2024-06-02

Post by talhaali on Create an alarm list without use of Alarm config CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Create an alarm list without use of Alarm config CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by jeffg on License issue with visu tags CODESYS Forge talk (Post)
I seem to be having a problem with the license on ver 3.5.19 patch 5 The runtime keeps going into demo mode but it wont tell me the reason I looked at the license software metrics and the visu doesn't appear to be working I attached screen shots of the metrics screen and the license dongle that is plugged in to the windows PC Anyone have any ideas on how to fix this
Last updated: 2024-06-28

Post by tcarlbom on codesys sp20 opcua not working CODESYS Forge talk (Post)
hi, anyone else having trouble with opc ua in codesys sp20? i get Error 'BadIdentityTokenInvalid' was returned during ActivateSession i have tried both windows x64 runtime and linux runtime. i have created a completely new codesys project for this. in each of them i have only added the symbol configuration and selected one tag. i have tried several opc ua client, like ua expert, nodejs and python. all return Error 'BadIdentityTokenInvalid' was returned during ActivateSession so the problem must be the opc ua server.
Last updated: 2024-07-03

Post by taqamert on Codesys 2.3 & Peak PCAN CODESYS Forge talk (Post)
Despite working on it for days, I haven't achieved any results. I followed the necessary steps one by one as mentioned in the file you sent, but there hasn't been the slightest change. I couldn't find the step you mentioned "Set the 'Can Board Type' to PCAN USB" in the Word document. There is no such setting anywhere I looked. Is there a more detailed explanation available, or can you explain it in more detail? What am I missing?
Last updated: 2024-07-16

Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui CODESYS Forge talk (Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07

Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui CODESYS Forge talk (Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07

Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui CODESYS Forge talk (Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07

Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui CODESYS Forge talk (Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07

Post by nicopolux on Profinet RPC-call error CODESYS Forge talk (Post)
Hello everyone Since I have installed Codesys 3.5.20sp2 I cannot get the profinet features working again. Now I get RPC Blocked during device scan (see attached file) and when online I get RPC-call error (see attached file). I run Codesys on the last version of Windows 11, Profinet ports have been added to Firewall rules, and even with disabled Firewall I get same result I really never seen that before Same result using another PC I already spent 2 days to find the issu without any success, I would appreciate some help, thank you! Nico
Last updated: 2024-08-22

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23