Search talk: how to use interface set property

 
<< < 1 .. 27 28 29 30 31 .. 230 > >> (Page 29 of 230)

Post by timvh on Get Alarm status in Codesys CODESYS Forge talk (Post)
You are right, that you can use the GetState method, but it is not that simple. You first have to get a list of (filtered) alarms from the AlarmManager. You can find an example in Forge how to do this. See https://forge.codesys.com/prj/codesys-example/alarm-manager/home/Home/ Then you can go through this list to get the state of all the (filtered) alarms. See below the code which you could use. This is all based on the example from forge. Create a program: // This example shows how to access alarms via structured text. PROGRAM PLC_PRG VAR xInit : BOOL := TRUE; udiResult : UDINT; fbAlarmFilterCriteriaAll : FB_AlarmFilterCriteriaAll; fbAlarmManagerClient : FB_AlarmManagerClient; itfAlarmManagerClient : IAlarmManagerClient := fbAlarmManagerClient; xAlarm1 : BOOL; xAlarm2 : BOOL; xWarning : BOOL; iNrOfAlarmsInAlarmList : INT; iNrOfActiveAlarmsInAlarmList : INT; paitfAlarm: POINTER TO ARRAY [0..0] OF AlarmManager.IAlarm; iAlarmIndex : INT; eAlarmState: AlarmManager.AlarmState; END_VAR IF xInit THEN xInit := FALSE; fbAlarmManagerClient.itfAlarmFilterCriteria := fbAlarmFilterCriteriaAll; // register alarm client to get updated about alarm status / changes udiResult := AlarmManager.g_AlarmHandler.RegisterClient(itfAlarmManagerClient, 0, 0); END_IF // Polling the number of alarms udiResult := AlarmManager.g_AlarmHandler.GetActiveAlarms(itfAlarmManagerClient, parritfActiveAlarms => paitfAlarm, iCountActiveAlarms => iNrOfAlarmsInAlarmList); iAlarmIndex := 0; iNrOfActiveAlarmsInAlarmList := 0; WHILE iAlarmIndex < iNrOfAlarmsInAlarmList DO eAlarmState := paitfAlarm^[iAlarmIndex].GetState(); IF eAlarmState = AlarmManager.AlarmState.Active OR eAlarmState = AlarmManager.AlarmState.ActiveAcknowledged THEN iNrOfActiveAlarmsInAlarmList := iNrOfActiveAlarmsInAlarmList + 1; END_IF iAlarmIndex := iAlarmIndex + 1; END_WHILE See below some details about the function blocks: One function block should implement the IAlarmFilterCriteria interface. This can be empty except a few methods. FUNCTION_BLOCK FB_AlarmFilterCriteriaAll IMPLEMENTS AlarmManager.IAlarmFilterCriteria Method implementation (others related to interface are empty) METHOD AreAllAlarmClassesSelected : BOOL AreAllAlarmClassesSelected := TRUE; METHOD AreAllAlarmGroupsSelected : BOOL AreAllAlarmGroupsSelected := TRUE; METHOD GetPriorityFrom : USINT GetPriorityFrom := 0; METHOD GetPriorityTo : USINT GetPriorityTo := 255; The other function block should implement IAlarmManagerClient and get a reference to the FB which implements the IAlarmFilterCriteria FUNCTION_BLOCK FB_AlarmManagerClient IMPLEMENTS AlarmManager.IAlarmManagerClient VAR_INPUT itfAlarmFilterCriteria: AlarmManager.IAlarmFilterCriteria; END_VAR Method implementation (others related to the interface are empty) METHOD GetFilterCriteria : AlarmManager.IAlarmFilterCriteria // see VAR_INPUT for filter GetFilterCriteria := itfAlarmFilterCriteria; Off course you have to add the AlarmManager to your application and add some alarms to it.
Last updated: 2025-09-02

Post by tomast on Communication PLC with HMI - how to send DUT via NVL. CODESYS Forge talk (Post)
Hi everyone, I am working with project where i have DUT wihth struct. I would like to fill this data trough a form on HMI. I use NVL to communicate and i would like to know how is it possible to do this? Thanks for all your advice in advance.
Last updated: 2024-08-23

Post by e13740e on Сalling the context menu from the keyboard CODESYS Forge talk (Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05

Post by e13740e on Сalling the context menu from the keyboard CODESYS Forge talk (Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05

Post by mait-tim on Errors after moving from SP18 to SP20/21 CODESYS Forge talk (Post)
Hello, Im running into a problem after moving from SP18 to SP20 or SP21. After the update I have an error with the TextFieldInmputHandler.VariableWritten which is implemented if de visualisation part of my software. The interface seems to have changed. I cannot find the new implementation. Does anyone know how to solve this issue.
Last updated: 2025-10-20

Post by mait-tim on Errors after moving from SP18 to SP20/21 CODESYS Forge talk (Post)
Hello, Im running into a problem after moving from SP18 to SP20 or SP21. After the update I have an error with the TextFieldInmputHandler.VariableWritten which is implemented if de visualisation part of my software. The interface seems to have changed. I cannot find the new implementation. Does anyone know how to solve this issue.
Last updated: 2025-10-20

Post by rmaas on How to use/create SOTU in LD program CODESYS Forge talk (Post)
You can use the R_TRIG and F_TRIG function blocks to generate a pulse in Rising or Falling edge of your signal. Have a look here: https://content.helpme-codesys.com/en/libs/Standard/Current/Trigger/R_TRIG.html
Last updated: 2024-07-11

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
So we pay 380€ for SoftMotion licenses for each robot, but have to implement such an obvious use case manually without any hint in the official documentation how to achieve this. This is crazy...
Last updated: 2025-07-31

Post by hyys12 on How to use/create SOTU in LD program CODESYS Forge talk (Post)
Yes. R_TRIG and F_TRIG works exactly like needed for this.
Last updated: 2024-07-11

Post by pazderai on CanOpen write issue CODESYS Forge talk (Post)
Anyway, any idea how to get command byte 0x22 for sdo write if I use codesys cia405 canopen library?
Last updated: 2024-07-16

Post by correo0269 on SSD1206 CODESYS Forge talk (Post)
Hello, I want to use the LCD display ssd1306 with i2c but I can not add that device. Someone know how I can add the display?
Last updated: 2024-04-11

Post by ioannis-a on How to Use Personal Access Tokens from GitHub with Codesys Git CODESYS Forge talk (Post)
I have the same issue. Is there any solution?
Last updated: 2024-05-12

Post by totorovic on How to display the application name on a visualization (V3.5.16) CODESYS Forge talk (Post)
You could use the function AppGetApplicationInfo from CmpApp library. https://content.helpme-codesys.com/en/libs/CmpApp/Current/AppGetApplicationInfo.html
Last updated: 2024-05-14

Post by nano on Persistent variable storage CODESYS Forge talk (Post)
use the persistence manager. with the persistence-manager, you're aböe to define how, when and where you store your data
Last updated: 2024-06-16

How to change list of referenced visualizations of a frame by programm? (NOT how to switch vis!) CODESYS Forge talk (Thread)
How to change list of referenced visualizations of a frame by programm? (NOT how to switch vis!)
Last updated: 2023-06-01

Post by bingo on PLC Shell commands via ST Code CODESYS Forge talk (Post)
Suppose you need to switch PLC IP dynamically between 192.168.1.10\192.168.2.10, First, set PLC IP to 192.16.1.10. Create a PGVL with a flag ‘xUseSecondry’ xUseSecondry : bool ; create a function that use socket to update IP: FUNCTION fSwitchIP : bool VAR_INPUT useMainIP:bool; END_VAR --------------------------------CODE------ if useMainIP then SysSockSetIPAddress(‘0’, ‘192.168.1.10’); PGVL.xUseSecondry := 0; else SysSockSetIPAddress(‘0’, ‘192.168.2.10’); PGVL.xUseSecondry := 1; end_if Now, if during execution, you need to switch IP, call the function ‘fSwitchIP()’, Set input to 1 for main IP, 0 for secondary IP. In order to set secondary IP at startup, you can do the following: in your PLC_PRG add a flag: xInit : bool := 1 ; and the code: if xInit then if PGVL.xUseSecondry then fSwitchIP(0); end_if xInit := 0 ; end_if *Alternative way is to use system events.
Last updated: 2025-03-03

I want to use the function of PVT to realize move CODESYS Forge talk (Thread)
I want to use the function of PVT to realize move
Last updated: 2013-05-14

Trying to Use Python Script to Exclude Certain Objects from Build CODESYS Forge talk (Thread)
Trying to Use Python Script to Exclude Certain Objects from Build
Last updated: 2019-08-20

Which Lib to use, connect to a socket with URL instead of IP address CODESYS Forge talk (Thread)
Which Lib to use, connect to a socket with URL instead of IP address
Last updated: 2025-11-12

Post by nmcc on How to address visualization change with button press... CODESYS Forge talk (Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13

Post by nmcc on How to address visualization change with button press... CODESYS Forge talk (Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13

Post by elsmart on Sequential read and triggering of Modbs RTU channels in application CODESYS Forge talk (Post)
Hello I need some help understanding how to use Modbus RTU (COM port) in Codesys enviroment. I defined a Modbus Server device (slave) in device tree and added some channels to read from (function 3). Also I set trigering mode to Application. I have a POU in which I want to trigger each channel one after the other something like this (C code for better visualisation): for (int i = 0; i < channelsCount; i++) { triggerChannel(channelsArray[i]); // Start transmission while(channel.xBusy); // Wait for transmission to complete } I have found ModbusChannel function block documentation but examples are scarce. I don't understand how rising edge triggering works. What would be the best solution for achieving sequntial channel triggering? What is the common way to read multiple Modbus channels once every time a specified POU is executed?
Last updated: 2025-05-16

Post by niallel on How to change bHiresMode CODESYS Forge talk (Post)
Hi, I'm trying to get Scaling working on my axis. An increment produces 36.6mm of movement, so I want to put the units in application as 36.6. However the docs say that I need to change bHiresMode as it doesn't show me the option for Precision in the User Interface. I'm thinking that I need to change the precision so I can enter decimal places. How can I do this, or is my thinking wrong? Thanks,
Last updated: 2024-03-11

Compiling CoDeSys project using the command line interface CODESYS Forge talk (Thread)
Compiling CoDeSys project using the command line interface
Last updated: 2021-01-27

Gateway Interface Communicator CG150-2 CAN/USB CODESYS Forge talk (Thread)
Gateway Interface Communicator CG150-2 CAN/USB
Last updated: 2017-12-23

<< < 1 .. 27 28 29 30 31 .. 230 > >> (Page 29 of 230)

Showing results of 5740