Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ?
CODESYS Forge
talk
(Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05
Post by bschraud on Unerwünschte Username- und Passwortabfrage im Browserfenster
CODESYS Forge
talk
(Post)
Leider habe ich keine Lösung für das Problem gefunden. Glücklicherweise konnte ich die "CODESYS Control for Raspberry Pi MC SL" wieder auf dem 32bit OS zum Laufen bringen.
Last updated: 2024-05-06
Post by mdetrana on VPLCs Tab 'Grey-ed Out', Cannot Create VPLC
CODESYS Forge
talk
(Post)
When evaluating Codesys functionality, I found that the VPLC tab under Deploy Control SL > Operation > VPLCs is 'grey-ed out', see attached image. I'm trying to evaluate how my infrastructure will interact with Codesys on a Raspberry Pi 4, so I'm trying to demo running it before purchasing licenses. I was going through the Codesys tutorial here, and it never shows the tab as grey, so I do not know how to proceed. Let me know if I can get any additional information that can help. This could be related to an Info message that's sent when connecting- [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (<ip_address>) [INFORMATION] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [INFORMATION] Finished reading device information</ip_address> I'm not exactly sure what I would need to do to install a 'supported container engine'.
Last updated: 2025-10-09
Post by eschwellinger on Licensing info not available.
CODESYS Forge
talk
(Post)
yes and no ... if you run the license server on the host (to serve licenses to the docker instances / vplcs then there is no runtime which could check the licenses on the host. Therefore you need the CODESYS WBM to activate or check the licenes or you could use in CODESYS IDE the licensemanager ( not the one for the device licenses) but you have the the IP of the license server that he know where to search for the licenses ..tool options i guess to add it, will add a screenshot later.
Last updated: 2025-10-01
Post by lraja on Codesys Programming with phyBOARD®-Pollux i.MX8M Plus
CODESYS Forge
talk
(Post)
Dear All, I am trying to Developing a PLC using phyBOARD®-Pollux i.MX 8M Plus. It is very difficult to find the suitable Codesys control for i.MX8M. I have tried to install CODESYS Control for Linux ARM SL , but unable install it and I am getting the following error, [INFORMATION] Executing SSH command on root@192.168.0.10: Retrieving architecture from package management [ERROR] Expected exit value of command failed: expected 0, received 127 [INFORMATION] Standard output: sh: line 1: dpkg: command not found Kindly check and help phyBOARD®-Pollux i.MX 8M Plus Link : https://www.phytec.eu/en/produkte/single-board-computer/phyboard-pollux/
Last updated: 2023-09-23
Post by animesh on SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP
CODESYS Forge
talk
(Post)
Hello everyone, I am facing a persistent issue with the OPC UA Server on Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) and need help from the community. Device Information Name: Advantech Control x86 RTE V3 x64 Vendor: Advantech Co., Ltd. Categories: PLCs Version: 3.5.20.10 Description: Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) Problem Summary The OPC UA Server works perfectly when accessed via: opc.tcp://localhost:4842 opc.tcp://<hostname>:4842</hostname> But it does NOT work when using the LAN IP: opc.tcp://192.168.0.XX:4842 In UAExpert I get: Discovery FindServers on opc.tcp://192.168.0.XX:4842 failed (BadCommunicationError) Port is LISTENING in windows Firewall.. Tried with turning off the firewall completely. System Information Windows 10 x64 Advantech CODESYS RTE Soft-PLC (hard real-time) Network IP: 192.168.0.XX Hostname: WINDOWS-XXXXX Need your Support
Last updated: 2025-11-24
Post by kuegerls on OpC UA server on Raspberry Pi MC SL - Certificate Issue
CODESYS Forge
talk
(Post)
Hello, I have set up an OPC UA server following several guides, including this one: https://revolutionpi.com/documentation/tutorials/opc-ua-codesys-nodered/. The license for the runtime is installed on the device. However, I am unable to create a certificate for the OPC UA server in the security screen. I always get the error message: "The certificate has not been created by the device." Does anyone have an idea what might be causing this issue? Any help would be greatly appreciated! Thanks in advance! Best regards, Stefan
Last updated: 2025-04-02
Post by shrikantp007 on help to get codesys understand
CODESYS Forge
talk
(Post)
Hello , I need some help on how to start with , 1) how to get test license to test codesys , 2) how to take a configuration backup or running process back and post file on fourm so people can understand and deploy same file and get idea what is missing or configure wrong 3) where i can get pdf for codesys admin or programmer 4) what is hardware recommand ,i am running on windows guest on kvm server .is it ok ? 5) i am trying to get ardunio porject working ,using ardunio board as a modbus slave but its not working some how https://forge.codesys.com/forge/talk/Engineering/thread/bf832569b8/ Thanks in advance . shrikant pune -india
Last updated: 2024-07-22
Post by wbj0t on tool 'update raspberry pi' unavailable
CODESYS Forge
talk
(Post)
I also tried install Linux SL and ARM/Linux SL. Same problem: not available in tools...
Last updated: 2024-09-26
Post by tk096 on Soft Motion - PosControl External Encoder
CODESYS Forge
talk
(Post)
Hi, there is an example for PosControl: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_example_poscontrol.html
Last updated: 2025-06-12
Installing boot application to CodeSYS HMI SL without login through CodeSYS
CODESYS Forge
talk
(Thread)
Installing boot application to CodeSYS HMI SL without login through CodeSYS
Last updated: 2021-01-05
Missing plug-in and error C0299 generator code for codesys PLCnext SL
CODESYS Forge
talk
(Thread)
Missing plug-in and error C0299 generator code for codesys PLCnext SL
Last updated: 2022-07-05
CoDeSys OPC DA SL won't install on Windows Server 2012 R2
CODESYS Forge
talk
(Thread)
CoDeSys OPC DA SL won't install on Windows Server 2012 R2
Last updated: 2020-11-03
CODESYS development system integration with MQTT broker through IIoT libraries SL
CODESYS Forge
talk
(Thread)
CODESYS development system integration with MQTT broker through IIoT libraries SL
Last updated: 2020-09-10
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
CODESYS Forge
talk
(Thread)
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
Last updated: 2021-10-18
Raspi SL MC: Which core is used by OPC-UA server
CODESYS Forge
talk
(Thread)
Raspi SL MC: Which core is used by OPC-UA server
Last updated: 2020-12-16
Codesys for linux SL AMD64 and last update of UBUNTU 22.04
CODESYS Forge
talk
(Thread)
Codesys for linux SL AMD64 and last update of UBUNTU 22.04
Last updated: 2023-02-06
Post by eschwellinger on Only single ehternet ip drive is communicating
CODESYS Forge
talk
(Post)
which versions EIP & Runtime and which plc is this? Does it work if they are connected to one network interface?
Last updated: 2024-03-09
Post by trycyclepower on Only single ehternet ip drive is communicating
CODESYS Forge
talk
(Post)
I had them inserted separately, now under one Ethernet tree they are working.
Last updated: 2024-03-11
Post by eschwellinger on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
use Arm64 SL or Arm SL instead of the PI package - this will work
Last updated: 2024-04-24
Establishing TLS Connection with MQTT Broker using MQTT Client SL Package
CODESYS Forge
talk
(Thread)
Establishing TLS Connection with MQTT Broker using MQTT Client SL Package
Last updated: 2024-06-20
Post by mos89p on Codesys Soft PLC OPC UA server
CODESYS Forge
talk
(Post)
Hi did you check the log of OPCUA expert Client?
Last updated: 2024-06-27
Post by cfam on Codesys Control for PLCnext SL, Bus not running
CODESYS Forge
talk
(Post)
Good day I would appreciate it if you can give me some advice on how to fix my "Bus Not Running Error". I am Using Codesys 3.5 SP20 and Codesys Control PLCnext SL V4.12.0.0. Codesys control was installed on the device and I can log into it but it seems that it does not pick up the PLC or the IO attached (Please see attached Image). The Bus Cycle Task of the AXL F 2152 is set to Main Task and the "Always update Variable" is Enabled on each IO Module. My Main Task interval is set to 100ms and Priority is set to 0. I have tried other options and none seem to work. Your response to this issue will be highly appreciated.
Last updated: 2024-08-12
Post by cfam on Codesys Control for PLCnext SL, Bus not running
CODESYS Forge
talk
(Post)
Good day I would appreciate it if you can give me some advice on how to fix my "Bus Not Running Error". I am Using Codesys 3.5 SP20 and Codesys Control PLCnext SL V4.12.0.0. Codesys control was installed on the device and I can log into it but it seems that it does not pick up the PLC or the IO attached (Please see attached Image). The Bus Cycle Task of the AXL F 2152 is set to Main Task and the "Always update Variable" is Enabled on each IO Module. My Main Task interval is set to 100ms and Priority is set to 0. I have tried other options and none seem to work. Your response to this issue will be highly appreciated.
Last updated: 2024-08-12
Post by jp23 on Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Post)
Hi all, I am attempting to use the Control Win V3 soft PLC to control a WAGO 750-315 remote I/O system via modbus RTU communication. I am struggling to connect to the device. I have been following this tutorial: https://www.youtube.com/watch?v=YlRfkESaNds I have setup my devices as shown in the images below. I have verified that my com port settings are correct as I am able to connect/control using modbus simulator software with these settings. I have also connected to a modbus master simulator program as instructed in the video, but the orange triangles will not go away. Additionally, I have updated my settings to 485 using the PLC shell. I have also set "always update variables" to enabled (1). Serial port, PCI-Bus, and modbus serial device status all show as "Not Running."
Last updated: 2024-08-26
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.