Post by oudom on Missing Button State Variable
CODESYS Forge
talk
(Post)
My CODESYS 3.5 SP16 Patch 4 in the visualization Button property missing a configuration Button state variable. How do we activate the Button State Variable in the visualization as shown in the attach document?
Last updated: 2024-10-04
Post by ojz0r on Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Post)
One thing you could do is create an object with the variable as field with a function and procedure to get the variable (read) and set the variable (write). These are then called from your program and the vizualization.
Last updated: 2025-02-20
Post by andrax on Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Post)
Arrays with variable lengths are a bad idea. This makes your system unstable and can lead to crashes. Declare your array large enough to reserve enough memory
Last updated: 2025-05-24
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Post by sercan on Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project
CODESYS Forge
talk
(Post)
I want to run the following command by linking it to the A-Axis: G01 A45.0 Which TRAFO should I use to do this? SMC_TRAFO_5Axes and SMC_TRAFO_GantryCutter3 function blocks did not work! For example, when SMC_TRAFO_5Axes is used, parameters B and C can be resolved by the transformer. However, parameter A cannot be resolved. Only SMC_Interpolator displays the value of parameter A in the SMC_Interpolator => piSetPosition.dA output. Should I drive this axis with SoftMotion commands (MC_MoveAbsolute etc.)?
Last updated: 2025-05-07
Post by berkdan on SMC_ReadNCFile2 is always busy
CODESYS Forge
talk
(Post)
Hello, Iβm using CODESYS V3.5 SP18. When I try to use SMC_ReadNCFile2 to read the file /PlcLogic/gcode.nc, the function block's bBusy output remains TRUE indefinitely. Can you help me understand what I might be doing wrong? Here is how Iβm calling the function block. The value of strFileName is 'gcode.nc'. fbReadFile( bExecute := bExecute, sFileName := strFileName, bAbort := bCycleStop, fDefaultVel := RetainVariables.xSlowVelocity, fDefaultAccel := RetainVariables.xAcc, fDefaultDecel := RetainVariables.xDec, b3DMode := TRUE, bParenthesesAsComments := TRUE, fDefaultVelFF := RetainVariables.xFastVelocity, fDefaultAccelFF := RetainVariables.xAcc, fDefaultDecelFF := RetainVariables.xDec, ErrorID => gCNC.eErrorId, errorPos => gCNC.eErrorPos, ErrorProgramName => gCNC.eErrorProgName, bBusy => bReadFileBusy, sentences => sentencesss ); Thanks in advance for your help.
Last updated: 2025-06-16
Post by imdatatas on Use MC_Home without enabling the drive for homing method 35
CODESYS Forge
talk
(Post)
Hello, As far as I know, no matter which home mode is selected, the axis must be in Standstill mode to run MC_Home according to PLCopen state machine. However, if the function you want can already be done from a parameter in the driver of the vendor you are using, you can try to perform the same function by sending the required value to that parameter via communication with the SDO write command. Regards, Imdat
Last updated: 2025-06-25
Post by eschwellinger on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore
CODESYS Forge
talk
(Post)
1) https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html -> SL: Restrictions The combination of Raspberry Pi and a CODESYS Runtime is for private use, test and teaching purposes. Commercial use is not permitted. 2) you could switch between them by /etc/codesyscontrol/CODESYSControl_User.cfg [CmpRasPi] Architecture=armv7l for MC: armv7l for SC: armv6l for 64Bit: aarch64 or in the Deploytool:
Last updated: 2025-08-06
Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade()
CODESYS Forge
talk
(Post)
Setup: Net Base Services (NBS), TCP_Client + TLSContext, ePurpose := CLIENT_SIDE, connecting to a third-party embedded device (Velux KLF200 home automation gateway) whose factory-installed TLS certificate expired on 2026-07-12 and has no user-facing renewal path. Tested on both CODESYS Control for Raspberry Pi SL (3.5.19.0) and CODESYS Control Win V3 x64, with identical results on both. Goal: Accept the peer's expired certificate via a custom ICertificateVerifier implementation, since the certificate itself can never be replaced. Implementation: FUNCTION_BLOCK FB_MyCertVerifier IMPLEMENTS NBS.ICertificateVerifier VAR udiCallCount : UDINT; aeCurStateLog : ARRAY[0..9] OF NBS.RTS_IEC_RESULT; END_VAR METHOD VerifyCertificate : UDINT VAR_INPUT hCert : NBS.RTS_IEC_HANDLE; eCurState : NBS.RTS_IEC_RESULT; END_VAR IF udiCallCount < 10 THEN aeCurStateLog[udiCallCount] := eCurState; END_IF udiCallCount := udiCallCount + 1; VerifyCertificate := 0; // also tried: VerifyCertificate := eCurState; Wired in via tlsContext.itfCertVerifer := certVerifier at declaration time, alongside itfTLSContext := tlsContext set at TCP_Client's own declaration (per an earlier forum thread here on ensuring inline start-values on FB-typed variables are actually honored when nested one level deep - that fix was needed and worked correctly for getting the handshake to start at all). Observed: - VerifyCertificate is confirmed called exactly once per connection attempt (via the call counter above). - eCurState passed in = 0x709 = ERR_CERT_HAS_EXPIRED - correctly reflecting the actual state of the peer's certificate. - Packet capture confirms the full TLS 1.2 handshake completes correctly at the wire level: ClientHello -> ServerHello -> Certificate -> ServerKeyExchange -> ServerHelloDone -> our ClientKeyExchange/ChangeCipherSpec/Finished -> server's ChangeCipherSpec/Finished. Both sides successfully complete the cryptographic handshake. - Despite this, TCP_Client.Upgrade() subsequently returns NBS.ERROR.CONNECTION_ERROR, and the connection is torn down with a plain TCP FIN (not a TLS alert) roughly 7-8ms after our side ACKs the server's Finished message. - TCP_Client.eErrorID (inherited from LCon) remains NO_ERROR throughout - the failure is only visible via Upgrade()'s return value. - Returning 0 (ERR_OK/ERR_CERT_OK - confirmed via the CmpErrors2 Interfaces documentation that these are literally the same value) makes no difference. - Echoing eCurState back unchanged (on the theory that this callback might work like mbedTLS's native verify callback, where the incoming state is a flags value to be cleared/modified and returned, rather than paired with a separate fixed "accept" sentinel) also makes no difference. - Identical result across udiVerificationMode := 0, 1, and 2. - Importing the peer's certificate into the runtime's trusted certificate store via cert-import trusted makes no difference either. - With itfCertVerifer left at its default (no custom verifier) and udiVerificationMode := 2, the underlying engine sends its own fatal TLS alert (handshake_failure) immediately after receiving the peer's Certificate message - suggesting built-in validation may reject at the record layer independent of whether a custom verifier is even present. Questions: 1. Is there an additional step required for a custom ICertificateVerifier to actually override an ERR_CERT_HAS_EXPIRED (or more generally, any ERR_CERT_*) rejection, or is certificate validation enforced unconditionally for a CLIENT_SIDE TLSContext regardless of what the verifier returns? 2. Is 0/ERR_OK genuinely the correct "accept" return value for VerifyCertificate, or does it expect something else (a specific bit pattern, a different constant, a value that must be computed from hCert itself)? 3. Is there a supported way to connect to a peer presenting a certificate that is both self-signed and expired, short of the peer issuing a new certificate? Happy to share the full packet captures or additional test combinations if useful. Also worth noting for anyone finding this thread later: a maintained Node-RED library for this same device (node-red-contrib-velux-klf200, forked to handle this exact expired-certificate situation) solves it by disabling built-in TLS validation entirely (rejectUnauthorized: false) and doing fingerprint-based pinning by hand after the handshake completes, rather than relying on a validation callback - which may be the more realistic approach here too if ICertificateVerifier genuinely can't override this class of rejection. Thanks in advance /JΓΈrgen Disclosure: most of the CODESYS code and this investigation was developed with the help of Claude (Anthropic's AI assistant) - the state machine design, SLIP/checksum implementation, and debugging methodology (including the packet capture analysis) were worked through in an extended back-and-forth with it. Posting here because we've run out of self-serviceable options and this now looks like it needs input from someone with visibility into NBS's actual implementation.
Last updated: 2026-07-26
Post by timvh on SafetyApp - "Invalid ERR Ack input"
CODESYS Forge
talk
(Post)
I had a similar error "Invalid ERR Ack input". What you need to do is link an variable from the "non-safe" PLC to the Group IOs of the POU in the Safety app. * Add a POU to the SafetyApp (probably already done, otherwise you don't get this error) * Right click on this POU - select properties * Go to the Group IOs tab * Link a variable to the Err.Ackn. input I don't know about the Size of zero, I didn't get this error. Were you able to fix this?
Last updated: 2023-11-16
Post by simotion on Inheritance of axis
CODESYS Forge
talk
(Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07
Post by maxsus on Visu Frame-configuration___text will not work
CODESYS Forge
talk
(Post)
Hello I have a problem with the Frame-configuration. In the picture below you can see that I set the Editor Type to variable. If it would be text it would work, but it wasnt variable anymore. Thanks for your time. Sorry, my codesys is in German.
Last updated: 2024-08-20
Post by maxsus on Visu Frame-configuration___text will not work
CODESYS Forge
talk
(Post)
Hello I have a problem with the Frame-configuration. In the picture below you can see that I set the Editor Type to variable. If it would be text it would work, but it wasnt variable anymore. Thanks for your time. Sorry, my codesys is in German.
Last updated: 2024-08-20
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Am I alone in this? Is this a known fault? Should I look for the reason of the lacking update option for "Control for linux SL" in my system or is it a potential fault in the codesys system?
Last updated: 2026-02-17
Post by pernockham on How to manage soft container licenses for (remote) multi units?
CODESYS Forge
talk
(Post)
Using Codesys runtime for Linux and thinking of the process of preparing multiple such systems for my customer. I don't necessarily have physical access to these units, they can be (very) remote. The idea so far is to use an image to install the Linux OS and codesys runtime. Application updates can be done by distribution of the PlcLogic/Application/application.app and application.crc files. But whats the most practical way of managing the license for these units? Do each controller need to be physically connected to a License Manager instance or can licenses be distributed by means of a license file for each unit? I believe that the license should be stored in soft containers for each unit. Help and insights appreciated! Per
Last updated: 2025-04-04
Post by brouwyka on JSONByteArrayWriter string result incorrect order
CODESYS Forge
talk
(Post)
Hello everybody! We are currently working on implementing a call to an API that tracks data sent to it through a JSON body. Versions: CODESYS V3.5 SP19 Patch 7 using IIOT Libraries SL license, specifically JSON Utilities SL version 1.13.0.0. For simplicity, let's say we want to construct the following JSON body for our request (simplified to just 1 key-value pair in each of the array objects to keep things shorter, but we'd have multiple fields in each in reality): { "id": "machine_1", "readings": [ { "temp_mid": 153.8 }, { "temp_mid": 98.3 } ], "status": "RUNNING" } However, our "readings" data is added over time, not in creation, so calls to the builder would be somewhat out of order. In a simplified manner, our calls would look like this: jsonBuilder(pJsonData := JsonData, diRootObj => rootJsonIndex); // rootJsonIndex = 0. // Set "id" at root JSON object. wsValue := "machine_1"; jsonBuilder.SetKeyWithValue("id", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 1, VALUE: diParentIndex = 1 & diIndex = 2. // ... Time passes, we get our first reading to add ... // The "readings" array does not exist yet, so we make it first at root JSON object before adding our first reading. readingsJsonArrayIndex := jsonBuilder.SetKeyWithArray("readings", diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 3, VALUE: diParentIndex = 3 & diIndex = 4. // Then add the first reading, for which we first have to make an object. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 5. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the first object in the array. rValue := 153.8; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := readingsJsonArrayObjectIndex); // JSONData KEY: diParentIndex = 5 & diIndex = 6, VALUE: diParentIndex = 6 & diIndex = 7. // ... Time passes, we want to add another root-JSON-level field ... // Set "status" at root JSON object. wsValue := "RUNNING"; jsonBuilder.SetKeyWithValue("status", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 8, VALUE: diParentIndex = 8 & diIndex = 9. // ... Time passes, we want to add a second reading ... // "readings" array exists, so add the second reading, but first we have to make another object. // NOTE the re-use of the earlier stored `readingsJsonArrayIndex`, so we add the new object to that previously created array. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 10. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the SECOND(, new) object in the array. rValue := 98.3; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 10 & diIndex = 11, VALUE: diParentIndex = 11 & diIndex = 12. // ... Finally, we want to send to the API, so we must convert the builder to data the client accepts as a body ... xTestWriteToJsonArray := TRUE; jsonArrayWriter( xExecute := xTestWriteToJsonArray, pwData := ADR(jsonDataString), udiSize := SIZEOF(jsonDataString), jsonData := JsonData^ ); IF jsonArrayWriter.xDone THEN // The writer was successful, the `jsonDataString` VAR should now contain a WString copy of the JSON object from the builder. xTestWriteToJsonArray := FALSE; END_IF We see that the JsonData STRUCT is correctly organised (in terms of the diParentIndex & diIndex set by it for each JsonElement) as we expect, as outlined in my comments in the simplified code above. However, as soon as we pass it to the jsonArrayWriter (which is a JSON.JSONByteArrayWriter), the resulting jsonDataString does not match our expectations, instead coming out like this: { "id": "machine_1", "readings": [ { "temp_mid": 153.8 } ] } { "temp_mid": 98.3 } "status": "RUNNING" The behaviour of the JSONByteArrayWriter thus seems to be the problem here. It does not seem to correctly process the children of JsonElements that are ARRAYs when additions to them are done broken up by additions to the lower level JSON OBJECT they are a part of. We have confirmed this by changing the order of the calls in our example to add both readings before adding the "status", in which case we get our expected outcome. However, in reality this is not possible for us - additions to any of the JSON's objects, arrays or array objects may happen at any time after other fields elsewhere in the JSON have been added. Does anyone know a way around this, a fix, or knows a solution we simply have not found? This same phenomenon was also noted on this forum by user @ryusoup at the end of 2023 (https://forge.codesys.com/forge/talk/Engineering/thread/c45929e2f1/#e27f) and user @mtho in early 2024 (https://forge.codesys.com/forge/talk/Engineering/thread/cd1bb450db/#1292) but both topics received no activity beyond both users' opening posts. Looking through the release notes of all the versions of the JSON Utilities SL library, I also did not see any remarks on resolutions of bugs in this vain. Thanks in advance for the assistance!
Last updated: 2026-06-10
Post by mondinmr on Jitter problems on imx8
CODESYS Forge
talk
(Post)
SOLVED!!! In this imx8 max_cstate=1 in kernel boot parameters is not working! We found a workaround: #include <stdio.h> #include <fcntl.h> #include <unistd.h> #include <stdint.h> int main(void) { int fd; uint32_t value = 0; fd = open("/dev/cpu_dma_latency", O_WRONLY); if (fd < 0) { perror("Error opening /dev/cpu_dma_latency"); return 1; } if (write(fd, &value, sizeof(value)) != sizeof(value)) { perror("Error writing to /dev/cpu_dma_latency"); close(fd); return 1; } while (1) { pause(); } } This simple code launched before CODESYS do the same work! Now jitter is identical as measured by cyclictest!
Last updated: 2023-10-19
Post by hteich on IECStringUtils.FormatDateTime
CODESYS Forge
talk
(Post)
Does that actually work, though? Where do you put in the actual Date_Time value??
Last updated: 2025-10-07
Post by oscardelmagno on Codesys v3.5.22.10 - Internal error:System.AggregateException...Value cannot be null...Parameter name: expLValue
CODESYS Forge
talk
(Post)
Last updated: 2026-08-25
Post by alexgooi on Update boot project default unchecked
CODESYS Forge
talk
(Post)
Dear Forum, I'm currently switching to Codesys V3.5 SP19. When I want to do an online change, I get the option to update the boot project, in other (codesys based) packages this is checked on by default. In Codesys V3.5 SP19 (and maybe older versions) this is unchecked by default. We are doing a lot of remote updates with systems that almost never power cycle. In other words when this box is forgotten the system will run fine until a blackout. Is it possible to get it checked on by default? This question was asked before, but no answers where given. https://forge.codesys.com/forge/talk/Engineering/thread/ffb4ffa298/ Thank you in advance.
Last updated: 2024-02-09
Post by hemuv on Dialog Open
CODESYS Forge
talk
(Post)
I'm programming an HMI for a machine. I want to log all the parameter's changes (used text field for displaying and changing) for particular User levels. Created a Numpad and want to log oldvalue and Newvalue on 'ok' Button press. To retrieve the oldvalue, i check if the dialogue opened is my Numpad, Then I retrieve the dialogue interface via GetDialogInterface(ADR(myNumpad)) --> numpadData.stVariableValue which contain my oldvalue and save it locally. Problem is sometimes i retrieve the data and sometimes not. Also observed when Numpad Dialogue is Opened, VisuDlgUtil_IsDialogOpen returns False in some cycles.Attached you will find my Project. please let me know what went wrong or if there is a better approach to collect old and New Value of a textfield. Thank you.
Last updated: 2025-03-26
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.