Post by shrikantp007 on new to codesys help on modbus with ardunio modbus rtu
CODESYS Forge
talk
(Post)
Hello , I am new to codesys ,working with it for just 15-17 days so ,i think i am able to installed it and configure it ,not i want to use ardunio program (smart dustbin ,college project using motor and Ultrasonic Module HC-SR04 and servo motor). i use ardunio program to write code with chatgpt to work ardunio as a modbus rtu as i dont have ethernet or wifi shild ,i wrote program in ariduno but now don have idea what change i have to make in codesys to comunicate as modbus slave it give error with bus error ,where i can get all errors ? Thanks in advance :)
Last updated: 2024-07-21
Post by hazarath on How extract JSONElement containing Array data
CODESYS Forge
talk
(Post)
I want to extract each element of an Array. Can someone help me with this. When I use JSONElementToString (part of JSON Utilities SL), I am seeing output as "ARRAY" instead of actual data. Here is the JSON content that I want to read : { "value1Unit": { "units": "M" }, "data": { "stepSize": 300.23, "points": [6,8] } } I would like to read each item of the element "points" i.e. 6 and 8. Here is the code I used, // Reading the content as JSON reader ( xExecute := execute , pwData := ADR ( converted_value ), jsonData := jsonDataStorage ); // Get the JSON Element jsonDataStorage.FindFirstValueByKey( wsKey := fidKeyVar, diStartIndex := searchElem, jsonElement => jsonElement ); JSON.JSONElementToString ( element := jsonElement , wsResult := valueWstring ); The content of the output of valueWstring is shown as "ARRAY" instead of the array items i.e. 6 and 8 Please can someone help me.
Last updated: 2024-07-30
Post by abrarsk on SysCom Library Usage
CODESYS Forge
talk
(Post)
Hello all, I am facing issues with using SysCom library. With SysCom23 library things were simple but since we are migrating to 64bit systems, I am writing a Porting program. With SysCom23, opening the comport was as simple as providing the ComPort no. which returns the Handle as a DWORD. dwHandle:=SysComOpen(Port); But the new library is a bit different. It is asking for 2 input parameters to open the Com Port - Port Number and POINTER to RTS_IEC_RESULT IF hCom = 0 THEN hCom := SysComOpen(ComSettings.sPort, ADR(pResult)); How should I use the RTS_IEC_Result? I can find RTS_IEC-REUSLT under SysType2Interfaces of SysCom library. Also, can someone give me a general understanding of this RTS_IEC_REULT and RTS_IEC_HANDLE, etc.?
Last updated: 2024-08-05
Post by yannickasselin on codesys VLAN tagging
CODESYS Forge
talk
(Post)
I ordered a cheap managed switch and tested it as soon as I received the switch. It works great! I even went a bit further. As you can see in the screenshot, I created 2 Codesys containers. Each one having 2 fieldbuses. The first one has EtherCAT and EtherNet/IP and the second one has EtherCAT and Modbus/TCP. All going through the same ethernet port from the PC to the switch. The switch splits it up into 4 different networks. The hardest part was to figure out how to configure the switch. @eschwellinger, thank you very much.
Last updated: 2024-09-17
Post by ben1 on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
Hi there mate Most PLC's have a very similar concept with AI/AO - have you used any other software before? I have not used a Wago before myself, but I assume the concept would very much be: 1. Add the analog in & out cards to your hardware config. 2. Setup the raw input scaling on the hardware (eg. 4 - 20mA = 4000 - 20000) 3. Use a built in or homemade scaling block to scale your input as needed (eg. 4000 - 20000 = -100 - 2000kPa. 4. Write code as required 5. Scale output as needed (eg. 0 - 100% = 0-10000 = 0 - 10V) Is this the information you require?
Last updated: 2024-12-15
Post by timvh on Problem Reading Registers via Modbus from non Codesys device
CODESYS Forge
talk
(Post)
According to the documentation: https://wiki.teltonika-networks.com/view/RUT956_Modbus You need to create a Channel to read 2 registers from address 143 to get the lattitude. It doesn't specify if you need to read it as a Holding Register or as an Input Register. You could try both. So in the Teltonika router, you need to enable it as being a Modbus Server. Then in CODESYS add an Ethernet Adapter, then a Modbus Client (Master) and to the Client (Master) add the Modbus Server (Slave). Set the IP address and add the Channel. The please consider that CODESYS doesn't update any variables when they are not used in the application. In the I/O mapping tab of your I/O configuration, you can set the "Always update" to enabled.
Last updated: 2025-03-08
Post by mondinmr on Shared Memory Access Issues
CODESYS Forge
talk
(Post)
In Windows I need create shared memory in PC software and connect from CODESYS. If shm is not GLOBAL doesn't work due different users between runtime and PC software. PC software need admin privileges. Name need "Global\\" before key. Very unsafe!!! If CODESYS create shared I cannot find key PC side. In Linux I can create shared memory as standard user, bind in the runtime docker, use keys without any "Global\\". Much more safe!!! If CODESYS create shared you need play with permissions to use app as standard user. I prefer create form PC software as standard user.
Last updated: 2024-01-30
Post by dhumphries on Rounding error in simple addition
CODESYS Forge
talk
(Post)
Thanks for the response, as I've thought about this problem over the last month I began to suspect this was a problem with not being able to exactly represent .1 as a 32 bit binary number. I think I've found a work around by making the number an integer, then dividing it by 10 and storing that value as a floating point number. There is still an issue with the value not being exact somewhere in the 8th or 9th decimal place, but because I'm incrementing an integer value then dividing it, the error doesn't compound.
Last updated: 2024-05-25
Post by swol on HTML 5 - Controls -> Change Content-Security-Policy settings
CODESYS Forge
talk
(Post)
Sorry for being late to the party... so it is not possible to use the webbrowser tool to display external websites in a visu anymore? As it is not possible to simply "adjust the ContentSecurityPolicyIncludeTrustedOrigins setting in the automatically generated webvisu.cfg.json file" as stated in the docs? We need to display data read from a Raspberry Pi (part of our computer network) in our webvisu. We used to do it by entering the Pi's IP address as the URL variable in the webbrowser element but now (I don't know since when, I'm new on the job) "The page’s settings blocked the loading of a resource (frame-src) at 'IP address' because it violates the following directive: “default-src 'self' 'unsafe-inline'”. What are the options for displaying the data?
Last updated: 2025-11-11
Post by yannickasselin on Question about Demo License limitations for Modbus TCP communication and Fieldbus Instances
CODESYS Forge
talk
(Post)
As far as I know, there is no other limitations than the 2 hours limit. The demo mode should be plenty enough for testing purposes. Regarding instances. In the device tree, 1 master = 1 instance, no matter how many slaves the master is communicating with. But it is also possible that your Codesys runtime act as a slave. In this case, each slave in the device tree is one instance. You can also use the license metric tool in the IDE. This will tell you exactly how many instances you have in your project. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_edt_device_licensed_software_metrics.html
Last updated: 2026-02-28
Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error
CODESYS Forge
talk
(Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22
Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error
CODESYS Forge
talk
(Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22
Post by tehthoams on Library Search not working
CODESYS Forge
talk
(Post)
Hello All! Having a strange issue. When adding a library, I'm unable to search. Each time a window pops up 'creating the search index' and then has 0 results. I have the same behavior when using the library repository and pressing the 'Find' button. I wonder if there is a way to reset or fix this issue? It is making it very difficult to search and find proper libraries to add to my project. Much appreciated.
Last updated: 2023-10-17
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this point is part of my misunderstanding. Why, after the execution ot the motion FBs is set to FALSE and exsecuted at lest one time, it must be continuosly called, even if the motion control it's take from another subsequent instruction. This is what I really don't undertand, but what in fact it's happening. For example, in case of stopping a MoveVelocity FB, then Halting the motion by the related FB, the axis at spot goes into error. If there was bad trigger management, the various instructions would NEVER work.
Last updated: 2024-07-18
Post by dkugler on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
I can confirm that at my 4ms EtherCAT Master the frames per second is equal at round about 500 with Codesys SP19. The same program at SP16 it was at 380-430 f/sec. for me it will be interesting too, whats the reason is for this high frame count/sec? I havn't had the time to use a paket sniffer and analyse all the frames. I can't help with your other questions, sorry.
Last updated: 2024-09-19
Post by lsislsis on Alarms Placeholder
CODESYS Forge
talk
(Post)
Hello. When i put placeholders at "/etc/codesyscontrol/CODESYSControl.cfg" : [SysFile] FilePath.1=/etc/codesyscontrol/, 3S.dat IecFilePath.1=/proc/, cpuinfo IecFilePath.2=/proc/, iomem PlaceholderFilePath.1=/sys/devices/w1_bus_master1, $OneWire$ PlcLogicPrefix=1 PlaceholderFilePath.2=/data/persistence, $ac_persistence$ PlaceholderFilePath.2.Volatile=1 PlaceholderFilePath.2.View=1 PlaceholderFilePath.3=/data/alarms, $alarms$ PlaceholderFilePath.3.Volatile=1 PlaceholderFilePath.3.View=1 Where "Data" are my USB Flash. I take these attachment errors at run time. What i am doing wrong.
Last updated: 2024-10-15
Post by yannickasselin on MQTT QoS 1 & 2
CODESYS Forge
talk
(Post)
Using Wireshark, I can see that the broker sends the QoS 1 or 2 messages when Codesys MQTT client reconnects but they are just discarded and not acknowledged by Codesys MQTT Client. So the broker holds on to them and tries to send them back to Codesys every time the client reconnects but they are always discarded by Codesys. There really seems to be an issue with QoS 1 & 2 in Codesys. It really does not behaves like it should.
Last updated: 2024-10-31
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Finnaly i get it working. There was a line in the file that set the ADS1015 chip in /boot/firmware/config.txt which i removed and after that the ADS1115 has a green turning circle and i got values. i created a new component so it fits our ADS1015. see screenshot. It works also with Codesys Control for Raspberry Pi 64 SL after adding the ULINT_TO_UDINT conversion in the library. i think the chip was all the time in use by the Raspberry pi itself. Thanks for your help!
Last updated: 2024-11-12
Post by selim on Need help to get RS-485 signal in Cosesys .
CODESYS Forge
talk
(Post)
Hello Mr./Ms., I invested Raspberry Pi lot of time to get the output from the raspberry PI5. But, i did not get the signal. I use a raspberry pi 5> RS485 can hat > Modbus RTU, Industrial 8-ch analog acquisition module >weight transmitter jy-s60> S-load cell. I did not able to receive the signal from Modbus RTU to Raspberry PI5 where I use the RS 485 serial connection.
Last updated: 2024-12-01
Post by simone on Preferred way of managing Ip-adress/es for linux (debian) host?
CODESYS Forge
talk
(Post)
Hi pernockham, I think you should ask your device vendor. For some time I used one from an Italian company where they had made a library where you can manage the ip with a function (something like SetIPAddr...), it was based on connmann on linux. From my little experience is better to use the "default" way, so for me is to manage the config file on interfaces or use the ip addr utility
Last updated: 2025-03-24
Post by jbu0105 on Dynamic limits invaild
CODESYS Forge
talk
(Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04
Post by jbu0105 on Dynamic limits invaild
CODESYS Forge
talk
(Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04
Post by arvindkumar on Wago plc not going back to RUN Mode after Power failure
CODESYS Forge
talk
(Post)
Hi im using wago pfc750-8207 plc and my programming software was codesys v2.3, im facing some issue in my plc after power failure my plc not going back to run mode sometimes, i did sourecode download, boot application created and still facing this issue, out of 10 power failure 8 times its going to run mode some time its missing to go run mode and only sys indication is in on condition Kindly please help me.
Last updated: 2023-12-15
Post by user0815 on Web Socket Client SL -Bibliothek Fehler
CODESYS Forge
talk
(Post)
Hallo zusammen, ich hoffe ihr könnt mir weiterhelfen. Meine Codesys Version ist die V3.5 SP19 Patch 4 und die Zielsystemversion ist die 4.10.0.0 . Ich verwende Codesys ohne Lizenz. Ich probiere eine Verbindung über Web Sockets zwischen Node-RED und Codesys aufzubauen. Dabei kommt folgende Fehlermeldung und folgender Logeintrag. Ansonsten stehen keine Fehlermeldungen im Log. Ich weiß nicht wieso sich die demo mode Zeit nicht zurücksetzt beim neu starten der RUN-Time. Schöne grüße
Last updated: 2023-12-19
Post by jinlee on Multiple WebVisu
CODESYS Forge
talk
(Post)
Hi, thank you for replying. Basically, I have a main visu with frame selection. So, under some condition the frame will switch to a specific frame. It used to be controlled by variable using "Switch frame variable". However, I realise it will change all the HMI screen at one time. So I removed the variable, and still looking for a solution to do that. Do you have any idea?
Last updated: 2024-02-06