Post by e13740e on Сalling the context menu from the keyboard
CODESYS Forge
talk
(Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05
Post by e13740e on Сalling the context menu from the keyboard
CODESYS Forge
talk
(Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05
Post by mp9876 on Device logon problem following fresh install
CODESYS Forge
talk
(Post)
All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. ‘Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh install: YES then: Initially went with Administrator twice (user & password) but it did not like it. No device is responding to …: Continued by setting a new user Pressed OK and obtained the following message: Stopped and Restarted PLC at that point: Obtained the following: Attempted to login a 2nd time without success. Then I scanned the network to see if matching device can be detected: Only way to get it detected was to remove the tick in the ‘Hide non-matching devices…’ Attempted a WINK but got a return like this one: REFRESH either @ Users and Groups or @ Access Rights returns: Then created user ‘mp’ at Project level ang logged in: Understandably device user mp9876 was not valid for the Project. Device information A few questions comes to my mind following these connection attempts: 1- Gateway not configured properly message pops out because of a non-compatible device ? 2- Why would the device not be compatible ? 3- Any way to make the device compatible ? 4- Any ideas on how to get this connectivity problem to the device solved ?
Last updated: 2024-03-17
Post by duvanmoreno24 on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi all, I want to know if someone has an idea of how I can write on value change in Modbus Codesys. I have a Wago PLC and I was used to work with E-cockpit which it was quite easy to do that without the necessity to trigger any value when there was a change in the variable ( I will put how easy is ). how you can see just changing the trigger in "On value Change" will do that channel writing automatically when It detects a change in those arrays. On the other hand, in Codesys if I enable the rising edge in Codesys It ask me to put a bool variable and if triggers is going to write that value. That is making me that I have to create a function or a logic to detect the change, the problem I have is that doing that is very tedious. I first approach I got it was to create a Function who returns a bool when the value change, but I tried to keep the old value but what is happening is that in Functions all the data is erased every cycle so I can not keep any Old value. so in the Main program the trigger is going to be TRUE all the time due, the old value is cero every cycle. The second approach I got it was using a function Block (POU_1) and it works but I dont want to instance that function for every Channel or value that I want to check if the value change, Basically if I have 200 values to write trhough modbus I have to create 200 instances of that function which I think it is not practicall at all. It should be a better way to implement this as e-Cockpit from Wago Does. However, I haven't been able to know how.
Last updated: 2024-03-26
Post by kreisfilho on Stop raspberry from executing a plc program
CODESYS Forge
talk
(Post)
Hi guys, Can someone inform where in a raspberry pi are stored the codesys programs? I´ve been training the use of a RPI as PLC, which works pretty well, however while both the RPI and PC (running codesys) remain connected to the same network. The question is: how to run the codesys program downloaded to the RPI as a stand alone device (disconnected from the PC)? Thanks! Kreis
Last updated: 2023-08-23
Post by macros8 on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi all, in Alarm management you can latch some variable to show value within the alarm msg. It´s very useful sometime. But I´m wondering whether there is any possibility to represent that value as Text list. It´s quite common in other HMI tools and this is very useful in case of using some ErrorID for detail specification of error. Unfortunately I could not find any way how to do it but I believe that exists :) Thanks a lot. M.
Last updated: 2023-09-06
Post by alexgooi on OPC-UA Boolean format
CODESYS Forge
talk
(Post)
Dear Forum, We are currently making the switch from OPC-DA (Codesys server) to OPC-UA (Running on a Codesys controller). We are using Codesys version 3.5 SP 20. Our Scada system is expecting Boolean's to be represented as a 0/1 (True Boolean) but the OPC-UA server is representing a boolean as False/True This indeed matches the OPC-UA standard, but is there a way to configure the OPC-UA server's boolean representation? Thank you in advance
Last updated: 2024-08-06
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pietrobalint on Retain / Persistent Variables in Codesys for Raspberry Pi
CODESYS Forge
talk
(Post)
Hi micik, I am not sure I am using well the code, because I checked the directory and there is no retains.ret file. Now I deleted the code from my project and the values are still works as persistant variables after ssh reboot it seems to me they retain as their previous value. So I am a bit confused, maybe 4.12.0.0 Raspberry Pi SL solved the persitent variable problem...
Last updated: 2024-08-20
Post by mani-i4point0 on Codesys (Ethernet IP Scanner ) and Python (Ethernet IP Adapter)
CODESYS Forge
talk
(Post)
Hi, I am currently developing the software to establish the communication and data transfer between Python Module as a Ethernet IP - Adapter coding is running my laptop and Codesys as a Ethernet IP scanner in the resperry PI hardware. I am trying to look for some available recourses online, Can anyone suggest me to develop this function in Codesys and Python ? Best Regards, Mani
Last updated: 2024-09-24
Post by athuum on Error 'Library not found' and 'Unkown type'
CODESYS Forge
talk
(Post)
Hello, I am getting the following error and warning when trying to download a project into a PLC: - Library CmpTargetVisu has not been added to the Library manager, or no valid license could be found - Unkown type: 'CmpEventMgr.EventParam' As far as I can see, both are included, and licensed, in the library manager (see image). What could the problem be, and how would I resolve this?
Last updated: 2024-10-08
Post by mtnkyr on Ethercat Master
CODESYS Forge
talk
(Post)
Hi everyone, I am working on a 3 axes Cartesian robot. I take control of all the axes. In the Ethercat connection, the drive sequence is the same as in the program. For example, in the current program the order is as follows. 1. Axis_Z 2. Axis_X 3. Axis_Y Communication Diagram PLC->Drive_Z->Drive_X->Drive_Y When I try to change the order in the program while keeping the communication diagram the same, there is an axis drive mismatch. How can I fix this?
Last updated: 2024-10-22
Post by garrian on How to write multiple coils (Modbus FC15)
CODESYS Forge
talk
(Post)
Thanks! As far as I can see, the client can only send words. And on the server side there are an array for each of the functions: bool for coil and discrete, word for holding and input registers. I assume I can use holding register, then use bit mapping on the words instead of coils. But I really want to use the FC15/coils.
Last updated: 2024-11-17
Post by teichhei on The selected container ... does not fit your ticket
CODESYS Forge
talk
(Post)
Update, installed 3.5.19.70 with the same result. The error message is as useful as a chocolate fire guard. The container SN is in the 130-xxx range which should work. The Version, Chip, Rev number don't mean anything to me. There is no SD Card installed. I've also reinstalled a fresh Wago FW22 image, Deployed PFC200 SL and Edge for Linux, still the same result.
Last updated: 2025-01-09
Post by nz-dave on FAILURE TO OPEN PROJECT ON ANOTHER COMPUTER
CODESYS Forge
talk
(Post)
just now i have tried loading the achive file from today at work. using 3.5.20.4 same as at work. when i open the project it says " prject inspection, this project has been saved with a different version(codesys v3.5 sp20 patch 4).? one option in the above "project inspection" window just wants to download that same version again. the other option leads no where as it say the required add ons cant be resolved. just end up going around in circles.
Last updated: 2025-01-22
Post by timvh on Codesys Runtime Devie Password
CODESYS Forge
talk
(Post)
This has been moved because of security reasons. But it depends on how you start CODESYS where the project files are located (at least for Control Win from SP20). 1) If you start it through the sys tray icon, you start it as a service and the files will be located in: C:\Windows*System32\config\systemprofile\AppData\Roaming\CODESYS... (or C:\Windows*SysWOW64**\config...) 2) If you start it as a user, e.g. with a shortcut to the runtime, you can find it in: C:\Users\<your user="" name="">\AppData\Roaming\CODESYS...</your>
Last updated: 2025-02-11
Post by dogulas on Removing a symbol from the IEC Symbols Editor grid
CODESYS Forge
talk
(Post)
gatto, That works. Thanks. Typically I use my mouse more than my keyboard. That's why I was looking for a delete option from the right-click context menu or a delete button on a toolbar at the top. It never occured to me to use the keyboard. It might be a little more user friendly if they allowed a mouse wise ability to remove a line from the grid as well as the DEL key. Just a suggestion. Thanks for your help.
Last updated: 2025-02-13
Post by stribor on Passing properties as VAR_IN_OUT variables.
CODESYS Forge
talk
(Post)
I am designing a custom slider object and i ran into a problem when i want to use properties with it. I can update the basic variables if i have a slider variable defined as VAR_IN_OUT, but it does not work with properties. How can i achieve same functionality that some basic objects have (for example basic Slider that comes withing the codesys libraries) such that i can pass both variables and properties to it and they can be modified within the object? I am using Codesys V3.5 SP20 Patch 5.
Last updated: 2025-03-01
Post by eoahe on Problem Reading Registers via Modbus from non Codesys device
CODESYS Forge
talk
(Post)
Hey Guys :) I have the following Problem using Modbus via Codesys: I'm trying to implement a Modbus Device into my codesys project. The device is a Router from Teltonika (RUT956) and it can communicate via Modbus. Currently I'm trying to implement it into my codesys prject as a slave and I'm using my windows computer as master. As it is not a codesys device (the codesys application is not uploaded to device as it has its own software) I'm having problems requesting and reading registers from the router. I've set up my windows computer as Master and implemented the router as slave. When I go online on my master device it sais that it has established a connection to the slave (router)(So I'm thinking this could work as there is a connection?). The goal is to read the GPS (latitude and longitude) data and on the homepage of teltonika you can find the register address and number of registers (adress 143 for latitude and 145 for longitude; both have a number of two registers). I've found tutorials how to read specific registers via their register address with other modbus programs (like modbus-cli), but as my entire project is established in codesys I was hoping to read these specific registers via codesys so that I can show the GPS data on my dashboard. I've tried establishing slave channels but that hasn't been working. I tried read input register channels of the length 4 but it's not possible to define specific register addresses to read via codesys so that didn't work (I jsut get a slaves device failure) and I've also tried establishing 516 (total number of registers the router sends I think?) read inputregister channels but that has the samle failure... So i guess the problem I'm having is establishing slave channels to read these specific registers. Does anyone know how to tackle this problem and has maybe had the same problem? Or maybe someone knows a workaround? I'm quite new to codesys so maybe I'm also lacking expertise...
Last updated: 2025-03-01
Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess)
CODESYS Forge
talk
(Post)
Wow! Thanks mr Strucc. Changed to service to run as local acc, and now log works! The service (run from local acc) is using this config: C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg The path you first mentioned (c:\Windows\System32\config\systemprofile\AppData\Roaming) has no CODESYS folder in it (Windows 11 24H2 b26100.3194). Thanks for your help :)
Last updated: 2025-03-06
Post by nz-dave on ethercat softmotion axis error
CODESYS Forge
talk
(Post)
Hi all I'm having a little trouble get my axis to work. i can turn them off and on. i can run each servo manually inputting directly to the mapping address. as soon as i try to use any FB's like jog etc my servos wont move and error out. so far I've had error "SMC_ERROR.SMC_DI-POSITIONLAGERROR" and another one about not calling a fb. cheers. in the attachment I have just jogged X_Axis with the MC_JOG FB
Last updated: 2025-03-10
Post by glutenaron on Safety drive EL6900 and mitsubishi
CODESYS Forge
talk
(Post)
Hi, Im wokring to get my servo mitsubishi mr-j5-g40-rnj1 working with my safety drive. I have as you can se in the picture Ek1100 koppler and EL6900 as safety plc. My questien is how do i connect the safety_drive to the SM3_Drive_ETC_Mitsubishi_MelServo_J5_Axis1 down below? I get the error ((Logical I/Os]: The logical device 'Safety_Drive' is not mapped to any physical device.)) but how do i map this? regard
Last updated: 2025-05-13