Post by ragarcia on Error while using Codesys SP19 Patch 4 on Windows 11 CODESYS Forge talk (Post)
Hello everyone, I just installed Codesys SP19 Patch 4 on Windows 11 and every time I open Codesys I get an error that says (Attached image): 'One or more issues ocurred with the current versio profile. Please contact the vendor to resolve these problems. The plug-in {....} (Exactly 4.15.0.0) is required by the current version profile., but has not been installed. It is highly recommended that the tools is terminated. Do you wanto to terminate now?' I cannot install any package since I get this error everytime I open or try to install any package. Can someone help me please, thanks in advanced
Last updated: 2024-03-26

Post by wiresplus on How to Connect / Go Online without re-downloading the project CODESYS Forge talk (Post)
Hello, I have a PLC in a remote location. I can connect to it, but when I use a different PC, it asks me to re-download to the PLC - which will a) interrupt production and b) cause version issues. Codesys being open-source, if someone else has made changes, I need to be able to connect, upload the current project, compare it with mine and then decide what next. Every time I connect, it says Warning: An application 'Application' is currently in RUN mode on the PLC. As there is no matching compile information, this existing application needs to be replaced. Click 'Yes' to download the latest code or 'No' to abort. What am I doing wrong?
Last updated: 2024-04-13

Post by m83coding on Raspberry Pi Codesys SPI Master CODESYS Forge talk (Post)
Hello, I am trying to control shift registers 74HC596 and 74HC165 via Raspberry PI with SPI interface. So far I did it with a Microcontroller and now I wanna upgrade my Projekt with Raspberry Pi and Codesys Software to be more flexible. I tried to adapt PiFace Function Block to just send or recive a 8 bit via SPI interface of the my Raspberry Pi. With following code (see attached screenshots) * PLC_PRG * PiFaceDigital * PiFaceDigital.write8 * PiFaceDigital.read8 I have a signal at SCK and MOSI pin of the PI, so far so good. But I really struggle with the unterstanding of the code. Is there some detailed description of each line of code? Or is there somebody in the community who can explain each line of code? Or is there a more simple way to send / recive 8 bit via SPI? Manuel
Last updated: 2024-04-23

Post by garrian on How to sort JSON object in codesys CODESYS Forge talk (Post)
Hi there, I'm testing out MQTT from my Wago PLC using JSON object. I have managed to publish this {"Temperature":15.6,"Setpoint":38.0} to my broker. Now I', trying to subscribe to the same message. The result is this: '{"Temperature":15.6,"Setpoint":38.0}95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' First, why do I see 95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' at the end of the message? Second, how Can i sort out this data to use it in my program? I followed a youtube tutorial which gave me the attached result, which works. But I need some other smart way of doing this when the object gets even more data in it. Any help is very appreciated :)
Last updated: 2024-05-04

Post by fpawlak on KNX SL on stock PFC200 firmware CODESYS Forge talk (Post)
Hi All. Is it possible to use CODESYS KNX SL on stock Wago firmware (Codesys version, not e!Cockpit). I have Wago 750-8212 with firmware 0.4.04.03(26). When I tried to run 'KNX SL' or even 'Device Reader', I have got [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE3' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' What probbalby means that there is no running CodeMeter component on PLC. I have checked /etc/codesys3.d/CODESYSControl.cfg [CmpWebServer] WebServerPortNr=58080 [CmpSecureChannel] CertificateHash=86ccf31839a098ee32067179e26600f1bd6b36f8 [CmpUserMgr] AsymmetricAuthKey=a9d38381e75bbf1bbfc8749e97f536f68238a2ce So the question is if I can somehow add Codemeter to stock firmware? Or should I switched to CODDESYS Control for PFC200 SL or application-base runtime licence?
Last updated: 2024-05-23

Post by ragarcia on How to change login visualization for other visualization after user logged in CODESYS Forge talk (Post)
Hello everyone, I have a web visualization on Codesys and to be able to use the web visualization first an user and a password is requested. After the user logged in, I want to automatically change the visualization to the 'Home' visualization but I am not sure how to do this. In the login visualization I basically have a button with the input configuration to execute the action 'Login' after a click. Once the user is logged in, the visualization is still stuck in the login page and I want to automatically change to Home visualization if the user was succesfully logged in. How can I know the number of web visualization clients connected to my PLC? Thanks in advance
Last updated: 2024-06-04

Post by installwhat on C0077 on one machine but not another CODESYS Forge talk (Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11

Post by gatto on Modbus tcp - channel CODESYS Forge talk (Post)
Hi can you give more details? Are you talking about a danfoss? wich model? Can post the configuration of channel' I used, on the past, serial modbus with danfoss fc280 I remember ((id x 10)-1) I remember that you couldn't use continuous reading/writing of the directors but you had to use them one at a time. it seemed that reading empty registers (caused by x10) was not accepted by danfoss. So I had created a scan that used just one register, then the next etc etc with a timed interval. But this was for the serial, I don't know if it's the same thing with ethernet. I currently use Ethernet TCP/IP interface with FC280.
Last updated: 2024-06-13

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
I don't know why the EtherCat fails, but what happens is: First I have only one 1WireMaster running on my Raspberry Pi and EtherCat is running fine. Then I'd like to add a 2nd 1WireMaster. Therefore I enable a 2nd GPIO Pin on the raspberry in the file "/boot/firmware/config.txt". dtoverlay=w1-gpio,gpiopin=4,pullup=0 dtoverlay=w1-gpio,gpiopin=23,pullup=0 To be able to use this 2nd 1WireMaster in Codesys Runtime I Adjust the CODESYScontrol.cfg file and add there: PlaceholderFilePath.2=/sys/devices/w1_bus_master2, $OneWire2$ After a reboot the EtherCat Master is not working any more. I didn't even add a 2nd OneWire Master in Codesys, but still if I do the EtherCat does not work. Do you have an idea why?
Last updated: 2025-10-21

Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16

Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16

Post by mr-ege on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
Hi all! I'm trying to learn PLC Programing. Today I was making a simple PLC program, as you can see. When I compile the program without the visualization, there are no errors. However, when I add the visualization and then compile it, I get this error. I don’t know how to solve the problem. I have tried the following solutions: rebooting the PC and updating the software. Error Code: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr Compile complete -- 1 errors, 0 warnings Build complete -- 1 errors, 0 warnings : No download possible Version: CODESYS V3.5 SP21 Patch 3
Last updated: 2025-11-25

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
I think I understand my problem. They are most probably related to configuration of the network. When I use DHCP for the unit to my router it all works. However when using static IP I have not managed to reach functioning state. Trying to replicate the situation on my desk. Having a static IP on the "debian host" and a connection to my computer which then routes traffic on to internet. I have entered settings for gateway and netmask. I can ping from my "debian plc host" to internet and also do "curl google.com" so traffic seems to find its way through and back, still "Automation server" will not find the gateway. Any hints how a manual configuration should be done? Is it possibly a "firewall" issue of my "normal router"? Thanks for any help! Per
Last updated: 2026-01-27

Post by rik123456 on Alarmmanagement – Dynamic Alarm List CODESYS Forge talk (Post)
Hi, I had a question about alarm management in the CODESYS visualization. I am currently investigating to what extent the alarm visualization can be built dynamically. In my program, I have developed a motor block that is used for multiple motors. When the emergency stop of one or more motors is activated, the corresponding motors are displayed in the alarm list (see image). This works quite well. I achieved this by linking variables to a latch, after which a piece of code displays the motors that are in emergency stop. My question is: do I need to create a separate latch for each motor or can I use a single latch to display multiple alarms of a motor underneath each other? This would then look like this: Time…: M1 Emergency Stop Active Time…: M4 Emergency Stop Active
Last updated: 2026-04-20

Post by kurt9 on ReadWriteEEprom FB question CODESYS Forge talk (Post)
I want to programmatically write the alias address to a new EtherCAT slave when I plug it into my IPC EtherCAT network. I am looking at the ReadWriteEEprom FB and see that one of the elements is "pbyData". which is the pointer to byte that is usually set to 2048 bytes. Since I am setting the alias address to the EEprom only (EEprom address 16#0012), I would assume that what I am writing is 2 bytes only. Does the pbyData have to be specified as ADR(myArray) where "myArray" is the 2 bytes of the alias address? How is the best way to set this element of the function block? Thanks in advance
Last updated: 2026-05-18

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Ok, with debug you suppress the errors, but that doesn't help you any further. You can find information about the missing drivers here https://forge.codesys.com/forge/talk/Runtime/thread/8981ce928a/ and here https://github.com/stefandreyer/I2C-Multiplex I'll have to have another look at which library you need. But you can easily find out. Create a completely empty project and insert the TCA9548. You don't need the board. Then look in the library and resolve all conflicts If you can compile the project without errors, delete the TCA9548 and insert the ADS1115. The driver should then also run. Small bonus: with the TCA9548 you can expand your network as you wish and use identical sensors multiple times
Last updated: 2024-11-08

Post by aleksahin6824 on SysEthernet error CODESYS Forge talk (Post)
Good afternoon Please help with localizing the error. Periodically, but on the same time grid, the error SysEthernet: packet could not be sent occurs. PLC and motors from XINJE. PLC — XSA-330L, rev. 1.2, drivers — DC5C2 (rev.5) In the task configurator, all tasks are set to simple numbers (11, 13, 41 ms) for convenience. The jitter for EtherCat and SoftMotion tasks is less than the task cycle (2 ms jitter for a 6 ms task). The power supply is sufficient for both the PLC and the motors. The cables are in good condition. Please suggest where to look for the problem. P.S. The PLC uses proprietary Linux and there is no SSH access.
Last updated: 2026-08-30

Post by aleksahin6824 on SysEthernet error CODESYS Forge talk (Post)
Good afternoon Please help with localizing the error. Periodically, but on the same time grid, the error SysEthernet: packet could not be sent occurs. PLC and motors from XINJE. PLC — XSA-330L, rev. 1.2, drivers — DC5C2 (rev.5) In the task configurator, all tasks are set to simple numbers (11, 13, 41 ms) for convenience. The jitter for EtherCat and SoftMotion tasks is less than the task cycle (2 ms jitter for a 6 ms task). The power supply is sufficient for both the PLC and the motors. The cables are in good condition. Please suggest where to look for the problem. P.S. The PLC uses proprietary Linux and there is no SSH access.
Last updated: 2026-08-30

Post by paulpotat on Project size increasing continuously CODESYS Forge talk (Post)
I still have the same problem with Codesys 3.5 SP18. Initially, my project is ~5 Mo. I work on it for like 3-4 days and it goes up to ~10Mo. If I make an export of the project and import it in a new empty project, it goes back to approximately 5 Mo. Why is it doing this ?
Last updated: 2023-08-23

Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
Hi, Thank you for your reply! What should be the version 4.9.0.0? I have a user named pi on the pi, thats what i´m using as credientials to be able to for example update/install runtime. Or do i need another user? once agin, thank for the reply! Martin
Last updated: 2023-09-11

Post by kdasystems on WebVisu on mobile devices CODESYS Forge talk (Post)
Hello I have a problem with web visu. When I open it to normal screen it is with good quality, but when I use it on mobile phone or tab then it is really bad quality, almost not possible to read the information. Can somebody help me what are the exact settings in the visu manager for this
Last updated: 2023-09-13

Post by transmin01 on EtherCat Master cannot open network adaptor on Win10x64 target CODESYS Forge talk (Post)
Hi, If I utilise an EtherCat master with a Beckhoff EK1100 coupler on a Win10x64 target I get a "Network Adaptor could not be opened" error. I have tried this on both a VM and a physical PC. Has anyone experienced this issue? Regards Trevor
Last updated: 2023-09-14

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Hello, my PFC200 has run for a few month now without problems. But now it freezed 2 times a day. LEDs were green but the PLC was not reachable. After power off -> on. I found that the MQTT had an error: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED. And MQTT hadn't reconnect since then. I tried a cold and a warm reset but nothing helped. How can I solve this? Regards, Paul
Last updated: 2023-09-21

Post by callumo1 on Check For Open Dialogs On Client CODESYS Forge talk (Post)
Thanks for the reply. I want to be able to check if any dialogs are open of any name. I already have a function similar to what you have send but I don't want to have to run it for all the different dialog names. Thanks
Last updated: 2023-09-26

Post by i-campbell on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
I can't answer why it's not resetting, but from the description of g_udiMaxReceiveBufferSize, I would guess the sum of sizes of the mqtt packets received in one cycle exceeded this value. So the answer may be to increase that parameter. https://content.helpme-codesys.com/en/libs/MQTT%20Client%20SL/Current/MQTT-Client/Common/Params/MQTTParam.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_library_parameter.html
Last updated: 2023-09-26