Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17
Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17
Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17
Post by karel-bas on Loosing connection to emulation running on Linux
CODESYS Forge
talk
(Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19
Post by rossanoparis on Clarifications regarding the appropriate runtime system to use
CODESYS Forge
talk
(Post)
Thank you @TimvH It is clear that licences are application based and now thanks to your reply I could understand the meaning of RT systems. The RT called "CODESYS Control for Linux ARM SL" can be deployed on a generic debian based ARM system. The RT called "CODESYS Control for Raspberry Pi MC SL" is more specific for Rasberry HW. Did I understand correctly? Regarding the RT called "CODESYS Virtual Control SL" despite its description it is not clear to me when to use it. It seems that a project created using such RT system can be deployed on any HW. It sound good obviously, as it means that it is possible to realize a completely abstract project from its hardware. The only limit could be represented by the need of using a specific HW or OS feature, in that case a more specific RT system should be chosen. Is my last consideration correct? Regards Rossano
Last updated: 2024-09-26
Post by ellocco on XOR with four Inputs with OR-, NON- and AND-Operators
CODESYS Forge
talk
(Post)
My topic is more of academic nature, I would like to implement an XOR-operation with four inputs on my own (without the predefined XOR-operator) in a function block diagram (FBD). I have two proposals. One works fine and the other one is just an idea, but I do not know, if it is possible to code it in CODESYS V3.5 SP18 in form of a FBD. Here the one that works: And here an idea, which I have not managed to code it as an FBD: Any ideas? Is the 2nd diagram a correct interpretation of the coding task? And is there a way to implement it in form of an FBD in CODESYS V3.5 SP18? Followup (08-Nov-2024): Also in the current version of CODESYS (V3.5SP20Patch3) I have not managed to connect the existing blocks. In the alternative SPS-IDE PLCnext Engineer it is possible.
Last updated: 2024-11-08
Post by hyys12 on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
Hello. I am currently working on a WAGO PLC, where I am trying to wrap my head around how the analog inputs and outputs work in codesys. I have looked far and wide on the internet, for a general introduction to the whole concept, but I have not had any luck with finding anything that helped me understand it better. The whole goal is for me to be able to read an analog input from a temperature sensor, as well as using an analog output, to control a frequency inverter. I know these have nothing to do with each other, but that is all I have on hand right now. I am trying to program this using Ladder Diagram. The only thing is, that every video/guide I have seen/read using LD, just adds a whole lot of function blocks, to do all kinds of stuff they don't explain. My general question is, how would one go ahead and read the analog input, as well as transmit an analog output? Is there some kind of specific function block I would have to use for this, or some great video I can watch, to understand the inner workings. Is it somehow possible to see the values the PLC recieved/sends? Regards.
Last updated: 2024-12-11
Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server
CODESYS Forge
talk
(Post)
Ok, I have a simple test environment. From C#, using OPC UA, I can read DINTs, write DINTs, read Structs, but when I try to write a struct I get BadNotWritable. I am using Communication Manager, OPC UA Server, and IEC Symbol Publishing. I have a struct defined with one single DINT in it. The instance of the struct is in GVL. The struct is marked read/write in IEC Symbol Publishing. Any ideas? Pointers are welcome. public static async Task WriteStructA(byte[] structAData) { if (_session == null) throw new Exception("session is null"); // create a RequestHeader RequestHeader requestHeader = new RequestHeader { Timestamp = DateTime.UtcNow, TimeoutHint = 30000 // timeout in milliseconds }; // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA", 5), structAData ); // create a WriteValue object to hold the value to be written WriteValue writeValue = new WriteValue { NodeId = _structANodeId, AttributeId = Attributes.Value, Value = new DataValue(extensionObject) }; // put the WriteValue object into a WriteValueCollection object WriteValueCollection writeValueCollection = new WriteValueCollection() { writeValue }; // perform the write operation asynchronously WriteResponse writeResponse = await _session.WriteAsync( requestHeader, writeValueCollection, CancellationToken.None ); // check the result of the write operation if (writeResponse.Results[0] != StatusCodes.Good) throw new Exception("Write failed: " + writeResponse.Results[0]); }
Last updated: 2024-12-17
Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3
CODESYS Forge
talk
(Post)
Some findings on this issue: PEAK CAN Driver is the same as in every PCI card from PEAK. I updated the inf file. Here are my steps: 1. Include right VendorID into the *.inf file 2. Disable Windows driver check (Disable WHQL check). This you need because 3S driver is not certified. You will find steps via google or ask chatgpt :) 3. Select: Select driver from a list and navigate to the folder. Say yes to install an uncertified driver. 4. Driver installed and device without errors I did the same with CAN Card from ESD, but here you dont need to include the vendor ID. In ANY CASE it was not successful. The RTIOwdmgeneric is not available in Codesys or anyhow accassable :( I wonder that it fails in two cases, two suppliers, two driver in the same way. How can RTIOwdmgeneric implemented into the project?
Last updated: 2024-12-20
Post by sean-barton on Ambiguous namespace in library dependencies
CODESYS Forge
talk
(Post)
I am trying to install the MQTT Client SL in an existing project I have been working on for years. After adding the library to the project, and without adding any other code, upon building I get a C0180: Ambiguous namespace 'MBM' error between the memory block manager (MBM) in the NetBaseSrv dependency of the MQTT Client SL library and the memory block manager (MBM) in the CAA CanL2 dependency of the 3S CANopen stack library. I have tried: * setting "Only allow qualified access to all identifiers." in the properties for both the parent libraries. * deleting the 3S CANopen stack library. Upon (re)building the error simply points to another conflicting library - there are many. * deleting the Library Manager and rebuilding it. * adding the memory block manager library (used in the NetBaseSrv) manually and changing its namespace to MBM3S. None of the above allow me to access the MQTT library through its namespace (MQTT). Adding the memory block manager manually removes the C0180 error, but the MQTT library is not accessible - i.e. mqttClient : MQTT.MQTTClient; highlights the mqttClient as "Identifier 'MQTT.MQTTClient' not defined". Is there anything else I can try?
Last updated: 2025-01-09
Post by fabiodasilveira on PLC Shell commands via ST Code
CODESYS Forge
talk
(Post)
Hello Everybody, I have created a project for an Eaton XC303 that sends lots of data to a router via UDP. It works fine. However, when there is more than one product connected to the router, then it is necessary to change the IP address of the Ethernet port 0, from e.g. 192.168.2.11 to 192.168.2.12 (second product). It is easily done via PLC Shell (setipaddr 0 192.168.2.12), but the people in production is struggling with the PLC Shell commands and I would like to create a Visualization page that will hide that. I used the instruction: eChangeIPResult:= SysSockSetIPAddress(strEthernetPort, strIPAddress); and it works, until the PLC resets. I already read some posts and it appears that I need to stop the Ethernet 0 port and Reconfigure it, but I am really struggling to find the right way to do it. Any help will be much appreciated.
Last updated: 2025-02-28
Post by struccc on The future and proper use of CAA.BOLT, CAA.SEMA,..
CODESYS Forge
talk
(Post)
Dear All, Dear CODESYS, I'm curiously following CODESYS transitioning away from the CAA libraries, and I'm mostly in favor of these major changes. Naturally, I'd like to align my current (not end-user) developments accordingly. I'm tracking , reading release notes, ... And want to figure out the future :) Is it possible to hear / read more about the reasons, objectives and scope of these changes? One important element is CAA Types - CAA Types Extern. What is the plan with that? What's the future of CAA.SEMA, CAA.BOLT ? I have never used them (always relied on SysLib*), but they are tempting... Would be useful to have a platform independent "Macro" for this functionality... Is there something in existing or planned ? Are they suitable to be used in low level libraries... For Example IO-Drivers, Components, "to-become system libraries"? CAA.TaskLock, CAA.TaskUnlock ? Well, they don't claim platform independency, so I can't rely on those.... Any up-to-date advise, standard, pattern to follow in new libraries for task and resource locking? Practical set of conditional defines to be used? If this information is not publicly available, can you please send a private message about the proper way to achieve this? I have support agreement, just couldn't get trough with these questions... P.
Last updated: 2025-03-14
Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64
CODESYS Forge
talk
(Post)
Hello I am trying to download my project onto my Codesys Control RTE x64 soft PLC. and I have had an issue when downloading. [FATAL ERROR] Unresolved reference: 'SYSETHERNETADAPTEROPEN' [FATAL ERROR] Unresolved reference: 'SYSETHERNETADAPTERCLOSE' [FATAL ERROR] Unresolved reference: 'GETNUMBEROFADAPTERS' [FATAL ERROR] Unresolved reference: 'GETADAPTERINFO' [FATAL ERROR] Unresolved reference: 'SYSETHERNETIPFRAMERECEIVE' [FATAL ERROR] Unresolved reference: 'SYSETHERNETETHFRAMESEND' [FATAL ERROR] Unresolved reference: 'SYSETHERNETETHFRAMERECEIVE' [FATAL ERROR] Unresolved reference: 'SYSETHERNETIPFRAMESEND' [FATAL ERROR] Unresolved reference: 'SYSETHERNETFRAMERELEASE' Looking on the forum I have found other people had to install the network driver, which I have done following this youtube video by codesysGroup: https://youtu.be/10oj4wABaKc?si=664l83JXUGQSDlAe I have added the network driver, please see attached image. I have checked my BIOS to make sure my secure boot status is disabled, see attached image. when I go to component manager, the drop down menu doesnt have the new network adapter, see attached image. I have not yet purchased or installed any licenses is that what I am missing? What other reason is there that I can't download to the runtime. Thanks
Last updated: 2025-03-18
Post by pernockham on Engineering IDE from linux?
CODESYS Forge
talk
(Post)
I have done the switch (linux mint, virtual windows through QEMU/KVM) now and is generally pleased. Have had problems in two areas initially. To bridge IP to the Virtual unit (solved), I overthought things initially. Solution. Configure manually a bridge in the mint-"network connections". Use that bridge in the Qemu settings as "Bridge device", "Device name": "name of the configured bridge" Figure out where to store the projects. I started out have the data in linux world (sort of) and linking it the windows with "virtio-fs". That had some serious impact though on git-handling. It seems that virtio-fs interpreted any file-path as lowercase only even if there were uppercase, resulting in git not able to sync files between its repository and the source code (it created a new file-path for me with only lowercase). Then I switch to samba-share instead and this works much better, though (git-actions) is a part that still has low performance with lots of waiting for file-actions. What should be the best way of handling the source/git? Edit to answer myself: Save the project "locally" in windows, then a lot of slow performance is avoided. Then a git-remote sync for backup.
Last updated: 2025-05-08
Post by abuckie on i2c master not running
CODESYS Forge
talk
(Post)
Hello, I am trying to create an Ethernet/IP device that can read analog signals, do some basic logic on it and then hand communicate the results to an Ethernet/IP master. I am using the Raspberry Pi to experiment with this as I would ultimately like to drive a display as well. I have loaded up the runtime on the Pi and got the digital I/O working. I have an ADS1115 ADC to I2C board and I can't get it to work, I get a message telling me the i2c master is not running and I am not sure where to start with this. Is there a manual for running CODESYS on the Pi or something like that I am missing? I found this post and opening the project in CODESYS V3.5 SP21 it seems like tons of this wouldn't convert properly https://forge.codesys.com/forge/talk/Runtime/thread/f1400b71b6/ I have added in the library and device manually and copied the structured text program but lost at what to do if the core functionality of the master is not running. I appreciate any help, thanks.
Last updated: 2025-05-19
Post by canplum on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
Although I have set in /etc/codesyscontrol/CODESYSControl_User.cfg the [SysFile] PlaceholderFilePath.1=/media/pi, $usb$ PlaceholderFilePath.1.View=1 PlaceholderFilePath.1.Volatile=1 I am not able to copy a file to this directory defined by the placeholder. Neither SysProcess.SysProcessExecuteCommand2 nor SysFileCopy nor FileCopy is working. If I try to copy the same file to /home/pi all is working fine. I also can create and open a different file by using SysFileOpen. I don't understand why the system allows to open (create) and write files into that directory but doesn't allow to copy into it. Obviously there is a rights problem with the USB drive. I have already set the permissions to drwxr-xr-x 2 and the user to pi but without any success. With 3.5.16 I never had such an issue. Is there anybody with some hints how to solve that problem? Cheers, canplum
Last updated: 2025-05-23
Post by kuegerls on Programmatically clearing or syncing Data Source Manager cache?
CODESYS Forge
talk
(Post)
Hi everyone, is there a way to programmatically clear the cache of the Data Source Manager in CODESYS so that variable values are re-synchronized from the OPC UA server (Symbol Configuration with OPCUA features)? Alternatively, is it possible to trigger a manual synchronization of data source variables from within the application code at runtime? Here’s the situation: A variable is first written by the OPC UA client to the server in one state of a state machine and changes to another state – so the initial communication works. Later, the server changes the variable value, but the client does not receive or reflect the updated value, unless the variable is actively written again. I’m looking for a way to force the client (data source manager) to re-read or refresh the variable state from the server, possibly by clearing the internal cache or triggering a sync. Any ideas or suggestions would be greatly appreciated! Thanks!
Last updated: 2025-05-23
Post by jy77812 on MC_MoveCircularAbsolute Using Help
CODESYS Forge
talk
(Post)
Dear People I’m trying to draw a circle using MC_MoveCircularAbsolute, but I keep encountering an error. The error message is SMC_CP_CIRCLE_CENTER_NOT_ON_BISECTOR. What I’m trying to do is simply draw a circle with a diameter of 20, starting from the point X=0, Y=0. I’ve set CircMode to center. It seems like a simple task, but the error keeps occurring, and it’s giving me a headache. I’d appreciate your help. I’ve also attached the program, so please provide any advice you can. I want to use the mode as the center. I've tried changing multiple coordinates and it won't run. Please help. sample stCirculAuxPoint.c.X := 20; stCirculAuxPoint.c.Y := 10; stCirculEndPoint.c.X := 20; stCirculEndPoint.c.Y := 30; fbMoveCircularAbsolute( AxisGroup := AxisGroup, Execute := xGroupCirculEx, CircMode := SMC_CIRC_MODE.CENTER, AuxPoint := stCirculAuxPoint, EndPoint := stCirculEndPoint, PathChoice := 0, Velocity := 50, Acceleration := 50, Deceleration := 50, Jerk := 50, CoordSystem := SMC_COORD_SYSTEM.MCS, BufferMode := 0, TransitionMode := 0, TransitionParameter := , OrientationMode := , VelFactor := , AccFactor := , JerkFactor := , TorqueFactor := , Name := , Done => , Busy => , Active => , CommandAborted => , CommandAccepted => , Error => , ErrorID => , MovementId => );
Last updated: 2025-06-04
Post by westcountryewe on Displaying a Target Web Page on WebVisu
CODESYS Forge
talk
(Post)
I have a main PLC with my CODESYS project on, including Web Visu. I also have a second device used for pump monitoring, all of this is displayed on a seperate HMI. I am looking at displaying the pump monitoring HMI on WebVisu so that I can solely use 1 HMI rather than having two. I can project the pump monitoring HMI into Chrome, and log in and it works fine. When I'm using the Web Browser element in Web Visu, enter my URL (device IP) it shows me the web page, but doesn't show me all of it. It uses parts of JavaScript for the login authenticiation and various other widgets. Similarly, I cannot get Youtube or Google to display on WebVisu either (possibily because of the same reason). Does anybody have any tips on how I can display the likes of Youtube or Google onto WebVisu so I can view it on my 7inch HMI (I suspect that if I can get Youtube or Google to work, then I will also be able to get my pump montitoring web page to work too).
Last updated: 2025-07-09
Post by jakubmphoenix on EtherCAT Master on RaspberryPi with EtherCAT Slave on Beckhoff
CODESYS Forge
talk
(Post)
Hello everyone, I’m currently working on setting up an EtherCAT Master using CODESYS on a Raspberry Pi, and I’ve run into some issues I could use help with. Project Setup: EtherCAT Master: Raspberry Pi with CODESYS Control for Raspberry Pi 64 SL installed EtherCAT Slave: Beckhoff CX5130 with EK1200 coupler I/O Module: EL2008 License Module: EL6070-0033 I’ve installed the required CODESYS packages and the Linux gateway on the Raspberry Pi. In my project, I added the EtherCAT Master with the appropriate port settings and scanned for devices. The CX5130 shows up as a slave, but communication fails—I'm getting error messages and can't access the outputs. Specifically: The EL2008 output module isn’t recognized properly in CODESYS. There’s no option to communicate with it through the CX5130. I’ve tried connecting via both the Raspberry Pi’s built-in Ethernet port and an external network card. I've attached screenshots showing the errors I get in CODESYS and the devices detected via TwinCAT for reference. Any help or suggestions would be greatly appreciated! Thanks in advance! EMERGENCY FROM DEVICE 1001 ERROR CODE 16#A000 Error register 16#02 Error field: 16#02 Error field : 16#0E 16#04 16#00 16#04 16#00
Last updated: 2025-07-16
Post by gmau on RS232 Communication in CODESYS Control RTE V3
CODESYS Forge
talk
(Post)
Hello, I would like to implement RS232 communication into CODESYS Control RTE V3. I was writing the program testing it on CODESYS Control Win V3, where it worked fine. When I changed it to RTE, the communication was on, but I cannot send the data between PLC and scale - there is no or little response from scale - mostly one time receive and that is it. On Win V3 it was working fine. I read that I am supposed to configure CODESYSControl file for a proper communication using RTE, but even after that I can not get a stable and working communication. I am attaching my CODESYSControl and CODESYSControlUser data below, as well as I am sending the code from communication function. The communication should be through COM1 port of PC. CODESYS Version: CODESYS V3.5 SP21 + (64-bit) Runtime + Version: CODESYS Control RTE V3 Version 3.5.21.0 / CODESYS Gateway V3 - x64 Version 2.5.21.0 I would be much gratefull for any help. Sincerely,
Last updated: 2025-07-16
Post by pouyavakili on Execute Codesys Tests with python
CODESYS Forge
talk
(Post)
Thank you for your input! What I'm ultimately trying to achieve is automated test execution as part of a CI/CD pipeline (e.g. in GitLab or Azure DevOps). For this, I need to: Open a CODESYS project via script Build the project Run the Test Manager tests from a .TestRepository.xml Collect test results (e.g., pass/fail + a report) Exit with a proper return code (for pipeline success/failure) To integrate this into automation, I’m using the CODESYS scripting engine via Python (headless), but the issue is that the get_testmanager() function isn't available on the project object — even though Test Manager is installed, licensed, and works interactively in the IDE. Are you suggesting that I should: Use the Test Manager GUI to script the logic with its internal scripting language? Or is there a way to launch the Test Manager in headless/scripted mode, while still being able to control things via Python? If there's a supported way to automate tests with the Test Manager using scripting, especially from pipelines or headless environments, I’d really appreciate any pointers or example workflows. Thanks again!
Last updated: 2025-07-24
Post by kurtk on Modbus TCP Server
CODESYS Forge
talk
(Post)
ditto I'm just getting my codesys wheels on and the modbus stuff is confusing. I am re-platforming an existing PLC application On that platform one could simply tag variables to register numbers and the whole shooting match could be accessed via modbus and typically holding registers and input registers were treated the same way... On codesys I see there is a modbus TCP server Device I/O mapping tab and a Modbus TCP server IEC objects tab I get the sense that one can configure the serving of variables both/either way but am unclear about the optimum/necessary path. Apparently in the IEC Objects tab one can "ADD" something or other - presumeably channels. I have created a preliminary function block but the Select Function Block window shows nothing to select WTH ? I exported the Device mapping and was surprised to see the entire Device IO map - complete with all the bit-mapped holding/input registers!! WTH!!?? Bit-mapped words are strictly a nichey special purpose application. I am targetting making a couple hundred variables available which would turn into hundreds of pages of IO/mapping Is the FUnction Block IEC objects thingy an alternative to that ? I notice that CODESYS shows the tags which the PLC used to specify the register address... are tags used in CODESYS for any specific hard-core purpose ?
Last updated: 2025-08-19
Post by pernockham on AC Persistence - values are not read from file during start?
CODESYS Forge
talk
(Post)
Im struggling with the AC Persistence. AC persistence seems to work for any variable that is changed online and values are kept during reboot. However, if I try to edit the persistence files offline or replace the persistence files with a previously downloaded older persistence file (with modified values), the online value will not follow, as if the system did not at all read the file at boot? My testing sequence. - Edit a the value of a persistenced variable (with xSaveOnChange = True) - Save/download the associated persistence file, (and confirm the value has changed). - Edit the value online for a second time . - Stop runtime - Replace (upload) the persistence file with my previously downloaded file . - Coldstart/Warmstart/Start runtime - Whatever Im trying the value of my persistence variable will always be equal to that of my second edit as if the file is not read/considered during boot. What am I doing wrong?
Last updated: 2025-09-02
Post by timvh on Codesys virtual control redundancy
CODESYS Forge
talk
(Post)
I think it depends on what you consider as redundant. Is it allowed to plug the network cable in another device (server), move the USB key with license to the other device (server) and then start it up? Or should it automatically switch over within msec and take over the communication with the I/O flawlessly without noticing the switchover? We helped several customers setting up the CODESYS Redundancy functionality and the nice thing is that when you have it up and running, you can easily switchover from active to passive and when you download a new applicaiton, CODESYS handles the update of boot project on the passive controller automatically. Sure this will require an additional license and the license for redundancy, but if your installation is that critical it should be worth it. Please contact us (Extend Smart Coding) if you need any further information. We could help you setup the configuration and possibly provide the licenses for it (I noticed you are situated in the Netherlands).
Last updated: 2025-09-04