Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser CODESYS Forge talk (Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16

Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser CODESYS Forge talk (Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16

Post by tali on Configuration of disabled/deactivated visu elements CODESYS Forge talk (Post)
would be great to have such fucntionality. Sometimes it is not clear for user which elemetns are blocked and which are not - the greyed out eleemtns are not so different for low resolution / low quality screeens. What I have in my mind as well is to have a possibility to detect the visu Element clicked on and get its Access Rights. If it is blocked/deactivated, the dialog can be rised with INFO 'please login first with proper rights'. It is possible now to have a Mose event Handler ( Examples -> EventHandler) and rise the dialog out of ST (Exapmpals -> ST Dialogs). I am struggling still with getting the separate Visu Element under the mouse and its structure info
Last updated: 2025-12-05

Post by cvrettacos-dse on Table Element Scroll Return CODESYS Forge talk (Post)
Hello, I would like to use swipe/pan gestures to scroll a table visualization element (CODESYS 3.5.21.10) on a DSE M810 display. The swipe / pan gesture control works fine, however, I cannot figure out how to reset / navigate to the top of the table again with code. I have tried the Scrolling begin variable, and the visu manager is setting it to FALSE right away but the table doesn't actually scroll back to top. If I check the “Scroll elements with scrollbar” box, then the Scrolling begin variable works perfectly, but now the swipe/pan scrolling no longer works and you have to use the scrollbar. Is it possible to do what I've described? Any assitence you can provide is appreciated. Thanks.
Last updated: 2026-06-10

Post by cvrettacos-dse on How to reset scroll of a table element CODESYS Forge talk (Post)
Hello, I would like to use swipe/pan gestures to scroll a table visualization element (CODESYS 3.5.21.10) ona DSE M810 display. The swipe / pan gesture control works fine, however, I cannot figure out how to reset / navigate to the top of the table again with code. I have tried the Scrolling begin variable, and the visu manager is setting it to FALSE right away but the table doesn't actually scroll back to top. If I check the “Scroll elements with scrollbar” box, then the Scrolling begin variable works perfectly, but now the swipe/pan scrolling no longer works and you have to use the scrollbar. Any assitence you can provide is appreciated. Thanks.
Last updated: 2026-04-21

Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade() CODESYS Forge talk (Post)
Setup: Net Base Services (NBS), TCP_Client + TLSContext, ePurpose := CLIENT_SIDE, connecting to a third-party embedded device (Velux KLF200 home automation gateway) whose factory-installed TLS certificate expired on 2026-07-12 and has no user-facing renewal path. Tested on both CODESYS Control for Raspberry Pi SL (3.5.19.0) and CODESYS Control Win V3 x64, with identical results on both. Goal: Accept the peer's expired certificate via a custom ICertificateVerifier implementation, since the certificate itself can never be replaced. Implementation: FUNCTION_BLOCK FB_MyCertVerifier IMPLEMENTS NBS.ICertificateVerifier VAR udiCallCount : UDINT; aeCurStateLog : ARRAY[0..9] OF NBS.RTS_IEC_RESULT; END_VAR METHOD VerifyCertificate : UDINT VAR_INPUT hCert : NBS.RTS_IEC_HANDLE; eCurState : NBS.RTS_IEC_RESULT; END_VAR IF udiCallCount < 10 THEN aeCurStateLog[udiCallCount] := eCurState; END_IF udiCallCount := udiCallCount + 1; VerifyCertificate := 0; // also tried: VerifyCertificate := eCurState; Wired in via tlsContext.itfCertVerifer := certVerifier at declaration time, alongside itfTLSContext := tlsContext set at TCP_Client's own declaration (per an earlier forum thread here on ensuring inline start-values on FB-typed variables are actually honored when nested one level deep - that fix was needed and worked correctly for getting the handshake to start at all). Observed: - VerifyCertificate is confirmed called exactly once per connection attempt (via the call counter above). - eCurState passed in = 0x709 = ERR_CERT_HAS_EXPIRED - correctly reflecting the actual state of the peer's certificate. - Packet capture confirms the full TLS 1.2 handshake completes correctly at the wire level: ClientHello -> ServerHello -> Certificate -> ServerKeyExchange -> ServerHelloDone -> our ClientKeyExchange/ChangeCipherSpec/Finished -> server's ChangeCipherSpec/Finished. Both sides successfully complete the cryptographic handshake. - Despite this, TCP_Client.Upgrade() subsequently returns NBS.ERROR.CONNECTION_ERROR, and the connection is torn down with a plain TCP FIN (not a TLS alert) roughly 7-8ms after our side ACKs the server's Finished message. - TCP_Client.eErrorID (inherited from LCon) remains NO_ERROR throughout - the failure is only visible via Upgrade()'s return value. - Returning 0 (ERR_OK/ERR_CERT_OK - confirmed via the CmpErrors2 Interfaces documentation that these are literally the same value) makes no difference. - Echoing eCurState back unchanged (on the theory that this callback might work like mbedTLS's native verify callback, where the incoming state is a flags value to be cleared/modified and returned, rather than paired with a separate fixed "accept" sentinel) also makes no difference. - Identical result across udiVerificationMode := 0, 1, and 2. - Importing the peer's certificate into the runtime's trusted certificate store via cert-import trusted makes no difference either. - With itfCertVerifer left at its default (no custom verifier) and udiVerificationMode := 2, the underlying engine sends its own fatal TLS alert (handshake_failure) immediately after receiving the peer's Certificate message - suggesting built-in validation may reject at the record layer independent of whether a custom verifier is even present. Questions: 1. Is there an additional step required for a custom ICertificateVerifier to actually override an ERR_CERT_HAS_EXPIRED (or more generally, any ERR_CERT_*) rejection, or is certificate validation enforced unconditionally for a CLIENT_SIDE TLSContext regardless of what the verifier returns? 2. Is 0/ERR_OK genuinely the correct "accept" return value for VerifyCertificate, or does it expect something else (a specific bit pattern, a different constant, a value that must be computed from hCert itself)? 3. Is there a supported way to connect to a peer presenting a certificate that is both self-signed and expired, short of the peer issuing a new certificate? Happy to share the full packet captures or additional test combinations if useful. Also worth noting for anyone finding this thread later: a maintained Node-RED library for this same device (node-red-contrib-velux-klf200, forked to handle this exact expired-certificate situation) solves it by disabling built-in TLS validation entirely (rejectUnauthorized: false) and doing fingerprint-based pinning by hand after the handshake completes, rather than relying on a validation callback - which may be the more realistic approach here too if ICertificateVerifier genuinely can't override this class of rejection. Thanks in advance /Jørgen Disclosure: most of the CODESYS code and this investigation was developed with the help of Claude (Anthropic's AI assistant) - the state machine design, SLIP/checksum implementation, and debugging methodology (including the packet capture analysis) were worked through in an extended back-and-forth with it. Posting here because we've run out of self-serviceable options and this now looks like it needs input from someone with visibility into NBS's actual implementation.
Last updated: 2026-07-26

Post by mrbartpawlowski on Codesys Crash CODESYS Forge talk (Post)
Hi all, I’m new to codesys and working on some project. Codesy 3.5 V20 patch 3 Every time I try to use refactor codesys hang and not respond. I was trying to use repair function in installer but this is not helping at all. Wonder if anyone experience this behaviour? Sometimes I have Popup saying : Cannot insert ‘CreateTextFile’ bellow ‘<root>’</root>
Last updated: 2024-10-14

Post by thieulam on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive CODESYS Forge talk (Post)
Hello to all! How can I read or write, via my main code (ST), to the registers present in the DO of my ethercat CoE servo drive? These objects appear in the list of the INITIALIZATION page, and from here I can only access them at startup. How do I access it in run time from my main PLC_PROGRAM?
Last updated: 2024-06-19

Post by aniket-b on Scara3 kinematic robot error CODESYS Forge talk (Post)
Thanks Georg for responding. I have followed the suggestion mentioned in the real time problem. However, it does not solve the problem. The weird part is, the robot stops at the same position randomly and it does not stop when I increase the speed of the motion.
Last updated: 2025-12-23

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by cellohorst on File Creation Issue CODESYS Forge talk (Post)
Nope! The file path is $$PlcLogic$$ and NOT $$PLCLogic$$. Otherwise a new folder ('PLCLogic') is created (at least with a linux rt - like raspberry or compute module) with the new file in it if you open the file with eFileMode := FILE.MODE.MRDWR. That is a bad bug that I'll report right after this comment.
Last updated: 2025-03-03

Post by snhatton on Testing of Codesys program CODESYS Forge talk (Post)
There is a tool called test manager that is part of the Professional Developer's Edition of CODESYS. I would take a look at this tool for your testing purposes. There is a free 30-day trial so you can evaluate if the tool will meet your needs before investing in the license.
Last updated: 2023-12-08

Post by tvm on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
maybe this would be a better approach, then you don't have to pass the constant at all. FUNCTION fun : INT VAR_IN_OUT arr: ARRAY[*] OF INT; END_VAR VAR lower: DINT; upper: DINT; END_VAR lower:= LOWER_BOUND(arr, 1); upper:= UPPER_BOUND(arr, 1); see here as well https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_datatype_array/
Last updated: 2024-01-08

Post by mkintegration on Reading Absolute Encoder Position From Yasakawa Drive CODESYS Forge talk (Post)
I am looking to read in the absolute position of a yaskawa servo drive Sigma 7 that is using absolute encoder. It looks like yaskawa outputs this across there CN1 I/O connecter and during operation just outputs encoder pulses. But at boot up transmits the Multiturn data position and the Position within one rotation (pulse train) on two different wires. Once the drives are enabled it just uses incremental pulses. Does any one have experience with what IEC blocks to use to read this information in. I attached the Yaskawa Manual section that talks about the format.
Last updated: 2025-02-26

Post by mkintegration on Reading Absolute Encoder Position From Yasakawa Drive CODESYS Forge talk (Post)
I am looking to read in the absolute position of a yaskawa servo drive Sigma 7 that is using absolute encoder. It looks like yaskawa outputs this across there CN1 I/O connecter and during operation just outputs encoder pulses. But at boot up transmits the Multiturn data position and the Position within one rotation (pulse train) on two different wires. Once the drives are enabled it just uses incremental pulses. Does any one have experience with what IEC blocks to use to read this information in. I attached the Yaskawa Manual section that talks about the format.
Last updated: 2025-02-26

Post by hazarath on How extract JSONElement containing Array data CODESYS Forge talk (Post)
I want to extract each element of an Array. Can someone help me with this. When I use JSONElementToString (part of JSON Utilities SL), I am seeing output as "ARRAY" instead of actual data. Here is the JSON content that I want to read : { "value1Unit": { "units": "M" }, "data": { "stepSize": 300.23, "points": [6,8] } } I would like to read each item of the element "points" i.e. 6 and 8. Here is the code I used, // Reading the content as JSON reader ( xExecute := execute , pwData := ADR ( converted_value ), jsonData := jsonDataStorage ); // Get the JSON Element jsonDataStorage.FindFirstValueByKey( wsKey := fidKeyVar, diStartIndex := searchElem, jsonElement => jsonElement ); JSON.JSONElementToString ( element := jsonElement , wsResult := valueWstring ); The content of the output of valueWstring is shown as "ARRAY" instead of the array items i.e. 6 and 8 Please can someone help me.
Last updated: 2024-07-30

Post by pmanuele on Beckhoff AS1060 and EL7041 configuration CODESYS Forge talk (Post)
Hello everyone, i'm having some problems commanding AS1060 step motor with EL7041 (rev22) drive. With motor i've also the incremental encoder (05.2420.1230.0200.5009). I can correctly move the motor in "Position controller" operating mode with the internal counter. The problems start when i set the Encoder in feedback type or i change the operating mode. Does anyone have experience with these two terminals and can give me some advice of main parameters to check or change? Thanks everyone
Last updated: 2024-12-11

Post by dnordenberg on BOOL variable in OPC UA and modbus simultaneously CODESYS Forge talk (Post)
How can I have an BOOL variable that is read/write in both modbus TCP server and from OPC UA at the same time? Variables with %MX.n %QX.n addressing which is used for BOOL/coils in modbus server is not allowed in OPC UA symbol list on Schneider M251 controllers. I have already asked on Schneiders forum but there are not a lot of codesys experts over there :( So OPC symbols can't have a address and the modbus TCP server needs a address. So how should I do it then? It seems like an impossible combination. Since I want read/write access from both ways I can't just simply make a second variable and assign it the value of another since it would be a one way assignment. I also tried using VAR_CONFIG which then makes the address syntax %Q or %M in my main variable list and that fools OPC UA Symbol Configuration to allow it and then I add the complete %MX.n address of it in the VAR_CONFIG list. This semi works, I can toggle the BOOL from modbus but the OPC UA symbol seems to be read only. It displays symbol status but nothing happens when I toogle it. I think I need another way to have the variables and symbols pointing to the same bits in memory... My plan B is to write a BOOL array compare FB that saves a history bit from previous cycle and if that does not match current status at next cycle for either the OPC symbol or the modbus variable then it copies the new status over to the other. Maybe ugly but it's like my last alternative. Kind regards David
Last updated: 2025-07-14

Post by respl on Codesys Symbolic Access CODESYS Forge talk (Post)
We need to exchange data between two controller IFM and EXOR. Our one controller support codesys symbolic access while other support COdesys V3 application. can anybody tell me how to do communication between these two. Sample program will be highly appreciable. Regards, Rahul Sayre
Last updated: 2025-03-20

Post by mondinmr on CIFX 50E-DP on Linux. CODESYS Forge talk (Post)
We need to use two CIFX 50E-DP cards in two Linux PCs running CODESYS for Linux SL (the machines are x86). Has anyone experienced any issues? Do these cards work reliably under Linux?
Last updated: 2025-05-23

Is there any way to remove the warning for having two enumerators with the same value in the same enum? CODESYS Forge talk (Thread)
Is there any way to remove the warning for having two enumerators with the same value in the same enum?
Last updated: 2016-12-22

Post by simotion on Multiple Ethercat masters on one IPC CODESYS Forge talk (Post)
Our IPC has multiple seperate ethernet ports. Is it possible to have two ethercat masters on the IPC (on two different ehternet ports off course)? If so, is there documentation available on this, or are there watchouts? Thansk
Last updated: 2024-01-12

Post by simotion on Multiple Ethercat masters on one IPC CODESYS Forge talk (Post)
Our IPC has multiple seperate ethernet ports. Is it possible to have two ethercat masters on the IPC (on two different ehternet ports off course)? If so, is there documentation available on this, or are there watchouts? Thanks
Last updated: 2024-01-12

Post by bjarne-pagaard on Newly created texlists wont appear in the selection dropdown CODESYS Forge talk (Post)
I just had the same problem in 3.5 SP19 Patch 6. Trying to use a textlist for Combobox Integer element. The textlist cannot be selected in the IDE, and is not found when manually entering the name. The textlist is copied to the device, but is not used. Can confirm, that copying an existing textlist and renaming it does work.