Search talk: declaration of variables

 
<< < 1 .. 48 49 50 51 52 .. 131 > >> (Page 50 of 131)

Post by andrecavalcante on Warning code C0373 CODESYS Forge talk (Post)
Same thing. Anybody has a clue of this warning?!
Last updated: 2025-05-23

Post by eschwellinger on CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC CODESYS Forge talk (Post)
I would recommend to ask Moxa for a newer version of Debian. Debian 9 ("Stretch") has reached its end of life and is no longer receiving security updates from the official Debian Security Team as of June 30, 2022. This means any systems still running Debian 9 are vulnerable to security risks and should be upgraded to a newer, supported version of Debian like Debian 10 ("Buster") or Debian 11 ("Bullseye").
Last updated: 2025-07-14

Post by bmatlove on AXIS_REF_SM3 Error Codes? CODESYS Forge talk (Post)
I'm trying to firm up alarming of axis faults. Declutter the code and figure out what's what. Diving into it, I see the AXIS_REF_SM3 function block provides uiDriveInterfaceError and dwErrorId, but I can't find any significance of these further than Drive interface error number Parameter number: 1014 and Drive specific error identifier, parameter number: 1031, respectively. Is there some corresponding appendix I could use to decode these? Also, is there any relation to the Error ID (of type SMC_Error) of the MC POUs? MC_Jog, MC_Reset, MC_MoveRelative, etc? If so, are the above errors redundant? Thanks in advance.
Last updated: 2025-09-22

Post by snhatton on Add device greyed out CODESYS Forge talk (Post)
What type of PLC are you using?
Last updated: 2023-12-19

Post by snhatton on Add device greyed out CODESYS Forge talk (Post)
What type of PLC are you using?
Last updated: 2023-12-19

Post by reinier-geers on Inheritance of axis CODESYS Forge talk (Post)
Do You have a solution ? Ive want the same
Last updated: 2024-01-12

Post by alexgooi on Codesys OPC DA server requires more then 2 GB of ram CODESYS Forge talk (Post)
Last updated: 2024-01-25

Post by jamil on Send_email Codesys V3.5 CODESYS Forge talk (Post)
Hello Guys Where can I find the library of Send_Mail (FB)
Last updated: 2024-01-31

Post by jamil on Send_email Codesys V3.5 CODESYS Forge talk (Post)
Hello Guys Where can I find the library of Send_Mail (FB)
Last updated: 2024-01-31

Post by jackbrady on Function Blocks and arrays of function blocks CODESYS Forge talk (Post)
Thanks for the reply. Much appreciated.
Last updated: 2024-02-15

Post by noahpiskor on Configuration dialog screen with a Frame CODESYS Forge talk (Post)
Hello, I'm trying to configurate a frame. My goal is to have a frame with the symbol of a component. When I press the symbol a dialog screen of my choosing comes up. What variable should be used in the frame configuration, that I can put in the input configuration of my symbol. so that I can chose which dialog screen comes up on my multiply instances of this frame. Kind regards. Noah Piskor CODESYS V3.5 SP19 Patch 6
Last updated: 2024-04-02

Post by jonasz on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
PrtScr
Last updated: 2024-05-09

Post by talhaali on Alarm Class "Notification Actions" CODESYS Forge talk (Post)
Hi, do you have code implementation of this?
Last updated: 2024-06-06

Post by talhaali on Alarm Class "Notification Actions" CODESYS Forge talk (Post)
Hi, do you have code implementation of this?
Last updated: 2024-06-06

Post by thieulam on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive CODESYS Forge talk (Post)
ok. tnx! best regards.
Last updated: 2024-06-19

Post by jose-coro on Trouble installing codesys 64 3.5.19.0 CODESYS Forge talk (Post)
yes of course
Last updated: 2024-06-19

Post by gseidel on MC_Phasing state explenation CODESYS Forge talk (Post)
Hi kenth1973, MC_Phasing has been improved in recent versions. I would recommend to install the latest version of SoftMotion (4.20.1.0) and test whether the problem still exists, and if so, what the error identifier is. (Also check the PLC log in this case, it might contain additional information.) Setting the internal state of the FB is not recommended, it could lead to malfunction of the FB and unintended movements of the drive. Best regards, Georg
Last updated: 2025-11-28

Automation Server πŸ‡¬πŸ‡§ CODESYS Forge talk (Discussion)
The Industry 4.0 administration platform for users and operators of CODESYS compatible controllers
Last updated: 2026-06-16

Post by shamcke on Array with generic constant as persistent variable CODESYS Forge talk (Post)
Hello, I have written a function block that uses a generic constant for the upper bound of an array. I wanted to have this array in the persistent memory area, thus I constructed my FB as follows: FUNCTION_BLOCK FbWithGenericArrayLength VAR_GENERIC CONSTANT uiArrayLength : UINT := 10; END_VAR VAR PERSISTENT arr : ARRAY[1..uiArrayLength] OF INT; END_VAR In my PLC_PRG I declare an instance of said FB PROGRAM PLC_PRG VAR myFb : FbWithGenericArrayLength<10>; END_VAR This compiles just fine. When I let CODESYS fill my persistent list, it adds duplicate entries {attribute 'qualified_only'} VAR_GLOBAL PERSISTENT RETAIN // Generated instance path of persistent variable PLC_PRG.myFb.arr: ARRAY [1..uiArrayLength] OF INT; // Generated instance path of persistent variable PLC_PRG.myFb.arr: ARRAY [1..uiArrayLength] OF INT; END_VAR so I manually delete the duplicate. When i now compile, I get errors ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... [ERROR] Sandbox_FW31: PersistentVars [Device: PLC Logic: Application](Line 4): C0161: Border 'uiArrayLength' of array is no constant value [ERROR] Sandbox_FW31: PersistentVars [Device: PLC Logic: Application](Line 4): Type of mapped variable is not equal to original type Compile complete -- 2 errors, 0 warnings Build complete -- 2 errors, 0 warnings : No download possible Is is simply not possible to use a generic constant for the persistent array? Thanks in advance. Edit: It seems I can manually replace the uiArrayLength in the persisten list by the value 10 I used as the generic constant for this particular instance.
Last updated: 2026-05-29

Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon CODESYS Forge talk (Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20

Post by kurtk on dynamic modbus devices CODESYS Forge talk (Post)
I am CODESYS neophyte getting my wheels on. My goal is to re-platform an existing PLC application written in 61131 ST I've got the majority of the code/variables in a compilable form - excluding all the IO and comms nuances I am not sure whether this the right forum An important functionality which I implemented on the other platform was totally dynamic modbus devices... Most configurations I have come across impose static MB configs in which all configured devices MUST be present and functional... I have monkeyed around with MB enough to know that herding a half dozen MB cats into a working config can be tricky. I just do them one at a time and dynamically turn them on/off in whatever combination is convenient with ID, IP, baud, parity etc being runtime tweakable. I am totally curious whether this is possible with codesys, or whether its device configuration corrals one into a static cage which requires re-building the code to support flexible variations. Best regards
Last updated: 2025-08-19

Post by kurtk on runtime dynamic modbus devices CODESYS Forge talk (Post)
I am CODESYS neophyte getting my wheels on. My goal is to re-platform an existing PLC application written in 61131 ST I've got the majority of the code/variables in a compilable form - excluding all the IO and comms nuances I am not sure whether this the right forum An important functionality which I implemented on the other platform was totally dynamic modbus devices... Most configurations I have come across impose static MB configs in which all configured devices MUST be present and functional... I have monkeyed around with MB enough to know that herding a half dozen MB cats into a working config can be tricky. I just do them one at a time and dynamically turn them on/off in whatever combination is convenient with ID, IP, baud, parity etc being runtime tweakable. I am totally curious whether this is possible with codesys, or whether its device configuration corrals one into a static cage which requires re-building the code to support flexible variations. Best regards
Last updated: 2025-08-19

Post by timvh on Sorting array of any-sized structure CODESYS Forge talk (Post)
Look all the way at the end of the link below. This provides a way to use arrays with various lengths: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_array.html
Last updated: 2023-08-18

After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Thread)
After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
Last updated: 2023-08-22

<< < 1 .. 48 49 50 51 52 .. 131 > >> (Page 50 of 131)

Showing results of 3263

Sort by relevance or date