Post by imdatatas on Codesys IDE initialization error from a new Sandbox image
CODESYS Forge
talk
(Post)
Hello everyone, I created a new sandbox image on the D drive with Codesys Installer. However, when I launch the IDE from this image, it gives the error shown in the attached image. -- Codesys V3.5 SP19 Patch7. -- The installer is the latest (2.5.0). -- All packages in the installer were updated to the latest version as of today when creating the sandbox. -- The originally installed IDE on the C drive does not give this error when launched. -- I last upgraded it to Softmotion 4.20.1.0 through the installer. Has anyone encountered the same or a similar issue? Will this issue be fixed in the next update? Best regards, Imdat
Last updated: 2025-12-05
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Post by expertplas on No connection to opc server from codesys opc client
CODESYS Forge
talk
(Post)
Hello, we have aproblen to connect our CODESYS OPC Client to the OPC Server. We installed the client according the CODESYS manual. We can browse the server and variables can be linked to the PLC. I created a self signed certificate for the CmpOPCUAClent as described. The server has a cerificate also. I copied the certificates to the trusted zone of server and client. But when it comes to data exchange we get an error message. "Communication error in data source OPC UA Library. Error ID : 7001 German : "Kommunikatinsfehler inder Datenquelle OPC UA -Bibiothek. Es wurde kein genauer Fehler angegeben. Fehler ID : 7001" It semms that there is no cerificate exchange. We are working with CODESYS 3.5 SP19 Patch 5. Can anyone here say something about this error or has an idea for a solution? Thanks.
Last updated: 2024-08-19
Post by rafa on MODBUS TCP SERVER DONT AUTO-STARTUP
CODESYS Forge
talk
(Post)
Dear all, I have a project where I have two ModbusTCP communication drivers in the application. It's working normally until a power outage or the installation panel is restarted. As soon as the PLC CPU is restarted, the Ethernet port is OK, but the TCP Server displays an "UNDEFINED" error. I can't reset the error using the diagnostic confirmation or the "mbserver.xConfirmError" bit. I noticed that the error only appears in the "mbserver.byModbusError" memory and the description is "UNDEFINED." The "mbserver.xError" memory doesn't flag an error. When using the warm restart function and then START CPU, the devices return to normal operation. The following demonstration images; The main question is: How can I make devices boot automatically?
Last updated: 2025-07-15
Post by rafa on MODBUS TCP SERVER DON'T AUTOMATIC STARTUP
CODESYS Forge
talk
(Post)
Dear all, I have a project where I have two ModbusTCP communication drivers in the application. It's working normally until a power outage or the installation panel is restarted. As soon as the PLC CPU is restarted, the Ethernet port is OK, but the TCP Server displays an "UNDEFINED" error. I can't reset the error using the diagnostic confirmation or the "mbserver.xConfirmError" bit. I noticed that the error only appears in the "mbserver.byModbusError" memory and the description is "UNDEFINED." The "mbserver.xError" memory doesn't flag an error. When using the warm restart function and then START CPU, the devices return to normal operation. The following demonstration images; The main question is: How can I make devices boot automatically? Um using Codesys Version 3.5.20.30 Patch 3+ My CPU is a Weintek Cmtx Built-int - ( CMT3092x )
Last updated: 2025-07-15
Post by kevintumibay on Struggling to connect to EK1100 to Raspberry Pi
CODESYS Forge
talk
(Post)
SUMMARIZED VERSION OF QUESTION: I'm trying to connect a Raspberry Pi running "Codesys Control for Raspberry Pi" to a Beckhoff EK1100, unfortunately, when I try to connect I get the following messages SEE FIRST PICTURE DETAILED VERSION OF QUESTION: Hi everyone, I'm a college student that is super interested in learning about PLCs. I wanted to dive into the subject and decided to follow this great Instructables article: https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/ Thank you in advance for your help! My current setup is as follows: 1. I have Codesys Control for Raspberry Pi, version 4.14.0.0, (https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html) installed on a Raspberry Pi 3B. 2. I am using my smartphone hotspot to create a network. 3. I have CODESYS 3.5 SP21 (64 bit) installed on my Windows 11 laptop. 4. Both the Raspberry Pi and my laptop are connected to the smartphone hotspot network (I am wirelessly connecting to the Raspberry Pi). Connecting to the Raspberry Pi from CODESYS on my laptop: 1. I launch Codesys Installer -> I install Codesys Control for Raspberry Pi (link to the software). 2. I launch Codesys 3.5 SP21 (64 bit) on my laptop. 3. I go to file --> new project --> standard project --> in the pop-up I select "Codesys Control for Raspberry Pi" and "Structured Text" 4. I click on tools -> Deploy Control SL (on older versions of Codesys you would click on "update Raspberry Pi", I got that information from this video: link) 5. Inside Deploy Control SL --> I go to the "communication" menu and I input the IP address of my Pi, the password, and click on connect. 6. Inside Deploy Control SL --> I go to the "deployment" menu and I install Codesys Control for Raspberry Pi SL and Codesys Edge Gateway for Linux 7. Now I double click on "device" in the left hand tree and put in the IP address of my Raspberry Pi and click on connect --> success! I am able to connect! SEE SECOND PICTURE Powering the EK1100 and connecting it to the Raspberry Pi: 1. I am supplying the EK1100 with 24 V across the + and - pins. 2. I have jumper wires going from the + pin to the 24V pin and from the - pin to the 0V pin. SEE THIRD PICTURE 4. I am pretty confident that the EK1100 is receiving power because the "LED Us 24 V" and "LED Up 24 V" are lighting up. 5. I then run an ethernet cable from the EK1100 to the Raspberry Pi port (the Raspberry Pi is connected to my laptop wirelessly over WiFi). I think this connection should also be good since the LINK/ACT LED lights up. Trying to connect to the EK1100: 1. Back in Codesys I right-click on "Device" in the left tree and then in the pop up I click on "add device". 2. I then click on EtherCAT Master. 3. Next in a terminal window I SSH into the raspberry Pi and run the "ifconfig" command. 4. From there I get the MAC address for eth0 --> in my case: b8:27:eb:29:a9:25 5. Then, back in Codesys I double click on "EtherCAT Master" in the left hand tree. I then paste the MAC address into the "Source Address (MAC)" field. 6. I go to the Beckhoff official website and download the XML files for EtherCAT: https://www.beckhoff.com/en-en/products/i-o/ethercat-terminals/ek1xxx-bk1xx0-ethercat-coupler/ek1100.html? 7. I unzip those files in my computer into some folder that I can remember. 8. Back in Codesys I click on "Tools" --> "Device Repository" --> "Install" --> and then on the "Beckhoff EK11xx.XML" file. 9. In theory the necessary XML file is now installed. 10. THIS IS WHERE I RUN INTO THE PROBLEM: I then click on login --> I right click on EtherCAT_Master and then scan for devices --> and nothing. 11. It just doesn't detect it. On top of this whenever I login I get those orange triangles on the left on my tree. When I check the Log I get the messages at the very first screenshot of this post. SEE FOURTH PICTURE Solutions that I have tried to resolve this problem: 1. I thought it was maybe the .XML file so I installed all the .XML files from the EtherCAT folder that I downloaded. That didn't fix it. 2. I went on the Wayback Machine and got the .XML files from 2018 as I thought maybe an older version would work. This file of EtherCAT folders had a .XML file named "Beckhoff EKxxxx.XML" I thought this would work because that's the name of the file the guy in the Instructables used (https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/). That didn't do anything. 3. I ran the PLC on my computer instead of the Raspberry Pi and tried to connect to the EK1100, in case the issue was with the Raspberry Pi, but I still ran into the same error from the picture above: "Attention! The device was not found in the repository. Vendorcode: 0x0. Productcode: 0x0. Revision: 0x0". SEE FIFTH PICTURE 4. I reinstalled Codesys, I was originally on version 3.5 SP20 when I did this, I upgraded to 3.5 SP21 with no success. 5. I then thought the solution might be to first add the EK1100 hardware before connecting so I did the following: 6. Right click on "EtherCAT Master" on the left hand tree --> then click on "add device" --> then I added the "EK1100 EtherCAT Coupler (2A E-Bus)" MY THEORY OF WHAT IS CAUSING THE PROBLEM: I asked ChatGPT for help and it said that it might have something to do with the revision number. On the physical EK1100 it says "Rev. Nr.: 0018". I believe that this means that I need to a revision 0018 XML file but if you look in Codesys it says the version is 16 (picture above). This is confusing because I got my .XML file from the official Codesys website so it should be the most up to date version possible. I searched and I searched and I couldn't find a version 18 .XML file, I don't even now if this exists. Any help you can provide is greatly appreciated, I don't know what to do anymore and I really really want to get this working. Thank you!
Last updated: 2025-03-30
Post by installwhat on C0077 on one machine but not another
CODESYS Forge
talk
(Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11
Post by mondinmr on Jitter problems on imx8
CODESYS Forge
talk
(Post)
SOLVED!!! In this imx8 max_cstate=1 in kernel boot parameters is not working! We found a workaround: #include <stdio.h> #include <fcntl.h> #include <unistd.h> #include <stdint.h> int main(void) { int fd; uint32_t value = 0; fd = open("/dev/cpu_dma_latency", O_WRONLY); if (fd < 0) { perror("Error opening /dev/cpu_dma_latency"); return 1; } if (write(fd, &value, sizeof(value)) != sizeof(value)) { perror("Error writing to /dev/cpu_dma_latency"); close(fd); return 1; } while (1) { pause(); } } This simple code launched before CODESYS do the same work! Now jitter is identical as measured by cyclictest!
Last updated: 2023-10-19
Post by nicopolux on Profinet RPC-call error
CODESYS Forge
talk
(Post)
Hello everyone Since I have installed Codesys 3.5.20sp2 I cannot get the profinet features working again. Now I get RPC Blocked during device scan (see attached file) and when online I get RPC-call error (see attached file). I run Codesys on the last version of Windows 11, Profinet ports have been added to Firewall rules, and even with disabled Firewall I get same result I really never seen that before Same result using another PC I already spent 2 days to find the issu without any success, I would appreciate some help, thank you! Nico
Last updated: 2024-08-22
Post by hbuitrago on CmpIecTask-program loaded exception
CODESYS Forge
talk
(Post)
I'm facing an error that show on the codesys and the PLC that dont let either the PLC run or access it using the remote software, Error: program loaded exception Log: exception position:IP=0x0xfffffffe (no IEC context could be retrieved) component: CmpIecTask exception [accessviolation] ocurred: APP=[application], Task=[Task] POU changed, that inhibits an online change, Plase let me know if there is a solution for this issue, Best regards,
Last updated: 2024-09-06
Post by askic on PLC error log help
CODESYS Forge
talk
(Post)
Hello, I'm using Codesys 3.5.20.0 version and I noticed that even with the most basic standard project create, there are error messages like shown in the acttached picture. The similar questions are already asked here on the CODESYS Forge Talk, but remained unanswered. Exact screenshot is attached, but essentially I would like to know which component in the Codesys has CmpID = 0x00000019 and what this Timeout means?
Last updated: 2025-01-10
Post by respl on IFM EXOR Network variable Error
CODESYS Forge
talk
(Post)
We are connected IFM CR711S to Exor EX710. We are exchanging data using network variables. Both devices are configured on same project so no need to use file source. When tested application it works fine. But after 3 months same application not working. We are able to send data from CR711 to EX710 but data from Ex710 to CR711s works only for one scan when we cold reset CR 711S. Can somebody help to find out error.
Last updated: 2025-03-17
Post by tvm on VisuFbFrameBase.SetInputPositionData: The element id for the input position cannot be determined
CODESYS Forge
talk
(Post)
I'm getting this error on one of my projects. Searching for it I came across this https://www.codesys.com/fileadmin/data/Images/System/Releaseinformation/Patch-Note-CODESYS-Visualization-4300.html which says it was a bug VIS-1394, fixed in Visualization 4.3.0.0. I'm using a previous visu version, what is the cause of this error, and what can be done to work around it?
Last updated: 2024-02-08
Post by shabroz-gill on Unable to load boot application on ARMv7 device restart
CODESYS Forge
talk
(Post)
I download an application to an ARMv7 32 bit device. I start the applicatin and it all works fine. But when i restart the device the boot app is not able to start. I have to redownload the application from the development environment to get to run again. I get the following error messages in the log on the restart
Last updated: 2023-11-30
Post by hfelek on *SOURCEPOSITION* App = [Application] area=0, offset = 0 on default example
CODESYS Forge
talk
(Post)
Hello, I am trying to run CmpTemplate component provided by Codesys for version 3.5.17. I call MyExternalFunction from the component but I get error as shown below. I see component is loaded successfully on runtime logs. I feel like I am missing something basically.
Last updated: 2024-01-15
Post by alexgooi on Init Array input on a method
CODESYS Forge
talk
(Post)
Dear Forum, I would like to initialize an array input on a method. When I do this, I get the following error: "The type of ARRAY [1..2] OF BOOL cannot have a default value in this context." I attached a picture for more clarity. Is this simply not possible or is there a different way of tackling this problem? Thank you in advance
Last updated: 2024-02-26
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
from another post on this forum .... In your library project select Project -> Project Information. On the Properties table remove the "LanguageModelAttribute" Value "Qualified Access Only". This will allow you to access the object without qualifying the access. ...... I guess they've compiled it the library with that setting and now I need to mess around with versions.
Last updated: 2024-04-20
Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License
CODESYS Forge
talk
(Post)
I'm trying to get the OPC server setup on my machine and currently I'm not having luck. I went ahead and got my license setup. However when I go to run WinCoDeSysOPC.exe I get an error message that I don't have the code meter licenses installed. Does anyone have any ideas on how I can fix this issue?
Last updated: 2024-05-02
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
Hello everyone, following corrupted data on the SD card of our Pi3B+ provided with a machine, we reinstalled a CODESYS image for Raspberry Pi, but we cannot find the 4.9.0.0 runtime that is compatible with the project. Currently, the machine is on 4.1.0.0, and we tried a more recent version 4.13.0.0, but there are error messages. Thanks in advance.
Last updated: 2025-10-24
Post by giackanto on Eoe issues with Windows and Linux
CODESYS Forge
talk
(Post)
Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Control Technique. Despite following some online guides (https://content.helpme-codesys.com/en/libs/EtherCATStack/4.3.0.0/Ethernet_over_EtherCAT/fld-Ethernet_over_EtherCAT.html) I havenβt had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here is my configuration: On Debian: (See attachments 1, 2, 3) enp1s0 = Ethernet port enp2s0 = EtherCAT port tap2 = TAP device IP forwarding and routes are both configured. On Windows: (See attachments 4, 5) On Codesys: (See attachments 6, 7) Version: Windows 11 Debian GNU/Linux 11 Codesys 3.5.17 Control for Linux SL 4.7.0 EtherCAT 4.4.0 With this configuration, I can ping the TAP device, but not the drive (See attachment 8). Could someone explain how to properly configure all these settings? Thank you, GA
Last updated: 2023-12-19
Post by wildcard on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Hello everyone, I have a very simple program for the process, but it's driving me crazy and I can't see the problems I'm left with: Short topological description: Dual Core Berghof controller with softmotion runtime version 3.5.19.30; Two axes with servodrive on canopen bus, clocked distributed from master; Ethercat I/O node; 2 ms ethercat task, 2 ms canopen bus cycle time; I/O objects of the canopen master and canopen drives connected to the ethercat task cycle; Problem 1: Two separate programs each manage their own axis and drive, with separate state machines. A first axis moves primarily in velocity, except having to position itself absolutely at a predetermined point at the end of the job; the second axis, on the other hand, is a paper unwinder that changes, for each job cycle, from actions in absolute, relative, and cam displacement with the master axis. Well, the state machine of both axes was written in such a way as to call running the useful FB and change it on state change in this way: CASE i_stateMachine OF 0: o_Power(Enable := TRUE, bRegulatorOn := FALSE, bDriveStart := FALSE, Axis := o_PaperUnwinderAxis); o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_MoveRel(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_CamSelect(Execute := FALSE, Master := o_MachineAxis, Slave := o_PaperUnwinderAxis, CamTable := cam_PaperUnwinder); o_CamIn(Execute := FALSE, Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Execute := FALSE, Slave := o_PaperUnwinderAxis); o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis); IF ... THEN i_StateMachine := 10; END_IF; 10: o_Power( Enable := TRUE, bRegulatorOn := TRUE, bDriveStart := TRUE, Axis := o_PaperUnwinderAxis ); IF o_Power.Status THEN i_StateMachine := 20; END_IF; 20: (* Avanzamento carta *) o_MoveAbs( Execute := TRUE, Position := o_Somewhere, Velocity := 25.0, Acceleration := 3666.7, Deceleration := 3666.7, Jerk := 48000.0, Direction := MC_DIRECTION.positive, Axis := o_PaperUnwinderAxis ); IF o_MoveAbs.Done THEN o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); i_StateMachine := 30; END_IF 30: d_HomingPosition := ...; o_SetPosition( Execute := TRUE, Position := d_HomingPosition, Mode := FALSE, Axis := o_PaperUnwinderAxis ); (* ... *) IF o_SetPosition.Done = TRUE THEN o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis ); o_LogServer.Append(sMessage := '...', lscClass := LOGSERVER_CLASS.ALWAYS, sdt := o_CommonsMgrData.systime.sdtLocal); i_StateMachine := 40; END_IF; 50: ... The code above is a sketchy example of what I wanted to write. But it gives me a spot problem: in some, the state change results in a drive error, which is unrecoverable except with a reinitialization via SM3_ReinitDrive(). Things are improved a little if in the program I always run the call of all softmotion blocks in this way: o_Power(Axis := o_PaperUnwinderAxis); o_Jog(Axis := o_PaperUnwinderAxis); o_Halt(Axis := o_PaperUnwinderAxis); o_MoveAbs(Axis := o_PaperUnwinderAxis); o_MoveRel(Axis := o_PaperUnwinderAxis); o_CamIn(Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Slave := o_PaperUnwinderAxis); If I don't execute all the calls of all the motion FBs used, when exchanging machine state often (but not always), the axis goes into error with event id THE_FB_WASNT_CALL... Done a little diagnostics it seems that the FBs return the bDone, before they are completely terminated. I tried doing the machine state exchange not with the bDone bit of the FBs, but with the 'standstill' state of the axis. It didn't seem to change anything. Problem 2: During the use SM3_ReinitDrive() I get the erro in the log: "NetID 0: SDO read error for object 16#607C..." Assuming that the device involved it's one of the two servodrive, (no others device are present in the network), I don't found any object 0x607C in the 'possible object list in/out' of the two drive, and I don't understand where this object can be listed. So any ideas and suggestions regarding these two issues will be very, very welcome. If you need the source project, I am willing to send it.
Last updated: 2024-07-17
Post by sukrit on What licenses are required for runtime on raspberry pi cm4
CODESYS Forge
talk
(Post)
We have developed a project for 2 servo motors using raspberry pi computemodule 4 on ethercat master. we are using web visualization for display different screens. project is running well in demo. we want to implement it in production envoirment. being new still wondering which licences i need. Can We get this information in codesys devlopment software. code size is approx 5 mb, 1 instance of etharcat master and aproox 100 variables in visaualization.
Last updated: 2023-10-17
Post by mubeta on Reset problem with CMZ SD/SVM drive
CODESYS Forge
talk
(Post)
In a recent project with SoftMotion 4.15.0.0, where I integrated two SD drives from CMZ (from catalogue EDS and not imported), on CANopen bus, I found that the SoftMotion MC_Reset function does not reset the drive faults. Even if the drive is in fault, either on the device or on the drive at the CoDeSys level, the function does not reset, instead reporting the error code: no error to reset. Finally, I had to connect the reset bit of the ControlWord directly to a tag in my program. Something I never had to do on other drives: Lexium, etc. all reset simply with MC_Reset.
Last updated: 2024-07-24
Post by struccc on Problem Update new version Master ethercat
CODESYS Forge
talk
(Post)
Hi, I had some issues as well migrating to the new version. What I have learnt: - Have to check all the libraries in the library manager, if they are the proper versions. - Some other parts of the application, maybe an old library referenced by another one can keep the old Ethercat libraries.... Use the "Placeholders" function on the library manager - See if there is a new version available of the slave "devices". Might just have to update them ... I had problems moving from 4.7 to with 4.8, especially with the 2nd adapter for redundancy - some devices failed to initialize properly.... So I have just downgraded those libraries now. P.
Last updated: 2024-10-28