Search talk: if statement

 
<< < 1 .. 50 51 52 53 54 > >> (Page 52 of 54)

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' °C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' °C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by cfam on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Good day All I would like to share some information on this site for the Codesys team as well for the future members using Codesys Control for PLCnext if it is allowed. I hope that i Post it in the correct spot. Subject: Codesys, Codesys Control for PLCnext Objective: Using the following Phoenix components to built a PLC Rack and run it on Codesys: Hardware and Software used 1. 2404267, AXC F 2152 - Controller 2. 1088136, AXL F BP SE6 - Module carrier 3. 1088129, AXL SE DO16/1 - Digital module 4. 1337224, AXL SE PD16 GND - Potential distributors 5. 1088127, AXL SE DI16/1 - Digital module 6. 1337223, AXL SE PD16 24V - Potential distributors 7. 1088123, AXL SE AO4 I 4-20 - Analog module 8. 1088134, AXL SE SC-A - Cover 9. Codesys v3.5 SP19 Patch 4 10. Codesys Control for PLCnext V4.10.0.0 Process: Firstly I built the Rack according to the Phoenix Project+ Software tool. Where I rebuilt it onto my test bench . I used the PLCnext Engineer IDE from Phoenix and all Communications where up and running and my PLC program executed successfully. THEN I tried the same PLC Layout with Codesys and Codesys Control for PLCnext. It was not successful and gave me the "Error: Local Bus not Running". I searched the web for answers but was unsuccessful in finding a solution. So I tried to change my configuration and found that the following Modules COULD NOT be recognized by Codesys Control. The result was that the Local Bus Failed to run. 1337224, AXL SE PD16 GND - Potential distributors 1337223, AXL SE PD16 24V - Potential distributors Example 1, Resulted in "Error: Local Bus Not Running": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1337224, AXL SE PD16 GND - Potential distributors Module carrier slot 3: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 4: 1337223, AXL SE PD16 24V - Potential distributors Module carrier slot 5: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 6: 1088134, AXL SE SC-A - Cover Example 2, Result "Successful": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 3: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 4: 1088134, AXL SE SC-A - Cover Module carrier slot 5: 1088134, AXL SE SC-A - Cover Module carrier slot 6: 1088134, AXL SE SC-A - Cover Result: Codesys or Codesys Control for PLCnext, has a PROBLEM to identify the following Modules. 1. AXL SE PD16 24V - Potential distributors 2. AXL SE PD16 GND - Potential distributors Hope that this information could be useful in future. Best regards Jaco Pretorius
Last updated: 2023-12-06

Post by r-niedermayer on OPC UA subscriber not operational CODESYS Forge talk (Post)
Hi. As far as projects in "old version"s are concerned, these can be upgraded to newer versions at any time. To do this, the device must be updated accordingly and the copilers and library versions must be adapted. You can find instructions on how to proceed in the online help/FAQ: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_changing_compiler_version.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_cmd_update_device.html See also 4.3.22.4 "How to open an Example Project" within the following pdf for more details on the single steps: https://forge.codesys.com/lib/counit/tickets/_discuss/thread/3e991befbc/ca97/attachment/Public%20FAQ-v13-20240610_075228.pdf Regaring your OPCUA connection state always showing just "DISABLED", without knowing both sides of the assembly in detail, one can only approach the problem theoretically. We can give a chekclist on how to proceed: Fist, please recheck the communication settings in the OPC UA connection function block to ensure that the server URL, endpoint URL, and other settings are correct and match the configuration of the OPC UA server. Verify that the OPC UA server is running and accessible. -You can try to connect to the OPC UA server using a separate client, such as UAExpert, to ensure that the issue is not related to the OPC UA server itself. Test the security settings in the OPC UA connection function block to ensure that the correct security policy and certificate are selected. If you are using a dynamic connection to the OPC UA server, probe that the connection settings are correctly configured and that the OPC UA client is able to establish a connection to the OPC UA server. Also, please loock into the log files for any errors related to the OPC UA connection function block, these should be listet there. The log files may also provide additional information about the issue and help you to further troubleshoot the problem. FYI - Please see https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_obj_data_source_communication_opc_ua_server.html: Her you can finde the Communication settings via OPC UA Server -> layout Browse Live Server: The client connects to the server and detects the existing variables and types. From Information Model The client reads the data structure (layout) of the OPC UA Server from the information model set here and as a result receives the information about available variables and types. A connection to the server is not required. The list contains the information models installed in the OPC UA Information Model Repository. "Read Connection" Settings from IEC Variable (option set): - The connection settings used by the device are not read here from the dialog, but at runtime from the IEC variable specified here. - For this possibility, please see the Using a Dynamic Connection to an OPC UA Server (https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html) The settings for the communication of a Client-data source to an OPC UA Server can also be dynamically configured from the IEC code and can also be changed at runtime. For such a purpose, a structure is available in the DatasourceOpcUAServer library (For a description of the OPC UA Server, there is one included in the standard installation of CODESYS, https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html)
Last updated: 2024-11-04

Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess) CODESYS Forge talk (Post)
I run CODESYS runtime as a service and use CmpLog (the LogAdd2 function) to log different events to a file. I have done this many times before on various projects and hardware, and it works fine. On this particular system, I have CODESYS 3.5.20.40 running on a Windows 11 PC. The CODESYSControlService autostarts (with Local System credentials, the default), and the application runs fine. However, the configuration file is not read (or at least not the one that should be, or not the CmpLog section), and log files are not written to the disk. I would be thankful if anyone knew why this is happening and how to fix it. A note to CODESYS people: you must provide more information on the codesys configuration file, CODESYSControlService.exe and other major components and system behaviour. You created the service and various features (i.e. logging), but haven't explained how they work, which, in my opinion, is below standard for industrial automation software. These are my observations: - When running as a service, the config file is not read (none of them), or at least the CmpLog section is not read. I checked the log using Codesys IDE, and the CmpLog parameters are not the ones I have set in any of the config files. Which CmpLog config values does the service use, and where does it read them from? I have no idea, but it's not the config files. Here are the codesys config files I located on the PC's disk: o C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\CODESYSControl.cfg (only 2 lines in this config) o C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\AppDataFiles\CODESYSControlWinV3\CODESYSControl.cfg o C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg o C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\tempCFG\CODESYSControl.cfg - When I run codesys as an app (e.g. by clicking the icon), this config file is read C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg and log files are written ok. The icon target is "C:\Program Files (x86)\CODESYS 3.5.20.40\GatewayPLC\CODESYSControlService.exe" -d o the -d option, I think, starts a cmd-like window showing service debug output (the output shown in log in the IDE) o the -i option, again I think, means install the service - I tried adding -d to service start parameters in the registry, but it started only once and after that it refused to start. Knowing what -d does and which other options are available would be great (e.g. can I make the service read a different config file). - Syslog UDP logging works fine in any case. - These are my CmpLog parameters ~~~ [CmpLog] Logger.0.Name=PlcLog3 Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=10003 Logger.0.MaxFileSize=50003 Logger.0.MaxFiles=33 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314 ;Set the timestamp to RTC ~~~
Last updated: 2025-02-27

Post by kevinrn on Github Actions CI/CD tasks - development topic CODESYS Forge talk (Post)
Hello community, I just want to inform you about our plans and the current status of automating the build process for CODESYS libraries. So it might be helpful for some people who are in the same situation. Background story: I am a software engineer at powerIO GmbH, normally I use high level languages for the products we develop and offer. Sometimes I work with my team on CODESYS libraries, which can also be found in the CODESYS store. Most of the time I spend with them on architecture tasks and tasks that are not directly related to our products. Every time I see the manual processes for releasing a library etc., I am very surprised about this time intensive process. Current situation: I know there has been a scripting interface for years. CODESYS Git was released a few years ago, but the scripting interface was only released a few months (weeks?) ago. We developed a pseudo-automated solution a few months ago, but it was all very hacky. So now there is a better Git implementation and also more modularization and installation options. For example, the CODESYS installer has a full CLI, which makes it very convenient to install CODESYS installations headless. Plans: I think it's the right time to develop a better automation solution. Most of our software projects are hosted on Github and we use Github actions very intensively for other software projects. Therefore, we have decided to use Github for our CODESYS library projects as well. Following tasks should be implemented in automation for CI/CD tasks: - Automated setup of CODESYS installation (Already released: https://github.com/marketplace/actions/setup-codesys-installation) - Checkout CODESYS libraries - Execute tests scripts - Sign CODESYS libraries - Extract Library documentation - Create CODESYS package - Sign CODESYS package Side Note: - This is mainly a side project, and we do not provide support for the CI/CD part. - This topic is here to help and also to get help from other software engineers. - This project and idea is not prioritized as I am currently the only one working on it and I hope it will help us and also others and increase productivity. - We are putting this out there as an organization, but priorities can change quickly and the CI/CD tasks I am developing are mostly done in my spare time. So please don't expect this to happen in a short time or even be fully completed. I would be very happy if some ppl will join the development process and might be open to discuss some technical details for this. I hope this topic is not to off-topic, but I think the CI/CD part is very important today and it can increase a lot of quality and push productivity. Thanks :)
Last updated: 2024-03-28

Post by lzml on HTML5 visualization controls disabled on CODESYS Control for Linux SL - overlay not supported? CODESYS Forge talk (Post)
Hello, I'm developing a custom HTML5 visualization control (via the HTML5 Control Editor / Tools > Visualization Element Repository) and I'm running into what looks like a target-device limitation when trying to deploy it to CODESYS Control for Linux SL. I'd like to understand whether this is a known/expected limitation or something in my setup. Environment - CODESYS Development System: V3.5.22.0 - Target runtime: CODESYS Control for Linux SL, package version 4.15.0.0 (installed together with CODESYS Edge Gateway for Linux 4.15.0.0) - Visu system libraries (VisuElems, VisuElemsAlarm, VisuInputs, VisuNativeControl, etc.): version 4.7.0.0 - Host OS: Debian RT (minimal/base installation) - We only use WebVisu, not TargetVisu. What I did 1. Built a custom HTML5 control following the official HTML5-API-Examples pattern (.html5control.xml manifest + ElementWrapper.js + CSS), installed it successfully via the HTML5 Control Editor ("Save and Install") into the Visualization Element Repository. 2. In the Visualization Manager, enabled "Support client animations and overlay of native elements" (documented as required for HTML5 controls to work at all). 3. With the project's Device set to CODESYS Control for Linux SL, compiling/downloading fails with: "Overlay is not supported for your target visualization device." (Visualization Manager) Build stops with 1 error, download not possible. Isolating the cause - The Visualization Element Repository confirms the control is correctly installed. - With the project Device set to a Windows-based device, the HTML5 control appears and is enabled in the Toolbox as expected. - With the project Device set to CODESYS Control for Linux SL, the HTML5 control is disabled/missing from the Toolbox entirely, even though it's installed in the repository. This points to the Linux SL device description simply not declaring overlay/HTML5 support, rather than a missing package or Debian-side dependency (WebVisu itself already works fine for standard/native visualization elements on this same target). Questions 1. Does CODESYS Control for Linux SL currently support WebVisu overlay (and therefore custom HTML5 controls)? I found documentation stating overlay support for target visualizations (Windows and Linux) was added starting with CODESYS Development System V3.5.17.0, but that seems to refer to TargetVisu, and our case is WebVisu-only on a Linux runtime. 2. If not currently supported, is this on a roadmap, or is there a different Linux runtime package/edition that does support WebVisu overlay for HTML5 controls? 3. Is there any Linux-side configuration or package needed to enable this (given the check appears to happen against a static device capability declaration rather than a live server check), or is this purely a matter of the device description bundled with the current Control for Linux SL package? Thanks in advance for any pointers.
Last updated: 2026-08-05

Post by kuegerls on PROFINET Controller SL: WRREC remains BUSY forever, no DCE/RPC packets transmitted (RevPi Connect 5 + NORD SK205E) CODESYS Forge talk (Post)
Hello , I am currently evaluating the CODESYS PROFINET Controller SL on a Revolution Pi Connect 5 and have encountered a problem with acyclic PROFINET Record Access (WRREC/RDREC). System Hardware: Revolution Pi Connect 5 Runtime: CODESYS Control 4.16.0.0 (SDK 3.5.21.10) Development System: CODESYS V3.5 SP21 (64-bit) CommFB: 3.5.17.10 ProfinetCommon: 4.6.0.0 PROFINET Controller Device: PN-Controller 4.6.0.0 PROFINET Device: NORD DRIVESYSTEMS SK205E with SK TU4-PNT GSDML: GSDML-V2.46-NORDDRIVESYSTEMS-PNT-20251016.xml Network The PROFINET network is completely separated from the office network. RevPi: eth0 → Office network eth1 → PROFINET wlan0 → Visualization The PN Controller is configured to use eth1. IP configuration: RevPi (eth1): 192.168.100.1/24 NORD Drive: 192.168.100.3 Connection is established successfully. Current Status The PN Controller reports: Controller Status = Run Online = TRUE IP Active = TRUE Connections = 1 Cyclic PROFINET IO communication works correctly. Problem I am trying to access PKW parameters via WRREC (Record Index 100). The request buffer contains: 01 14 00 04 92 00 00 00 00 00 00 which corresponds to Reference = 0x01 Request = Read Axis = 0 Parameter = 170 + 1000 Subindex = 0 Value = 0 The WRREC call is fbWRREC( REQ := xWrReq, ID := ConnectionID, INDEX := 100, LEN := 11, RECORD := ADR(TxBuffer) ); REQ is pulsed for one PLC cycle only. Observed Behaviour WRREC enters BUSY state and never finishes. Observed values: BUSY = TRUE DONE = FALSE ERROR = FALSE STATUS = 16#FFFFFFFF indefinitely. Packet Capture A Wireshark capture was taken on the PROFINET network. Observed traffic: PROFINET RT LLDP DCP Observed: successful cyclic IO Not observed: DCE/RPC Record Write Record Read RPC Bind No RPC packets are transmitted at all. Diagnostic Messages The controller repeatedly reports AR alarm.ind(err) AR CMI timeout although cyclic IO communication continues to work. Already Verified The following points have already been checked: correct Ethernet interface (eth1) correct CREATE_ID result correct Device ID correct Slot/Subslot correct GSDML correct REQ pulse RECORD buffer is larger than LEN cyclic IO communication works different Record Indices (100...104) tested Question Is there any known issue or limitation where WRREC/RDREC requests remain permanently BUSY and no RPC Record Access packets are generated? Could this behaviour be related to Runtime 4.16.0.0, PN Controller 4.6.0.0, the missing runtime license (currently running in demo mode), or any known issue with the PROFINET Controller SL? I am currently evaluating the PROFINET Controller SL and therefore the runtime is operating in demo mode. Could you please confirm whether WRREC/RDREC (acyclic Record Data services) are fully supported in demo mode, or whether a valid license is required for these services? If required, I can provide: complete project archive Wireshark capture (.pcap) GSDML online screenshots diagnostic log Thank you very much for your help. Best regards, Stefan
Last updated: 2026-07-17

Post by thejesh on WebVisu: switch-frame destroys and rebuilds referenced visualization - is retention configurable? CODESYS Forge talk (Post)
Hi, HTML5 Conrtrol elements on CODESYS V3.5 SP22 Patch 2, WebVisu only (no TargetVisu). The client is Chromium 147 in kiosk mode on a Raspberry Pi CM5 panel; the runtime is CODESYS Control Win V3 x64/CODESYS Control RTE V3 x64 on a separate IPC. I have measured that changing a Frame element's switch-frame variable destroys the currently referenced visualization and fully rebuilds it on return, including all embedded HTML5 controls. We would like to know whether this lifecycle is configurable. Measurement 1: Curently, our production page contains a good number of custom HTML5 controls and will only increase , each of which the WebVisu client instantiates as a separate about:srcdoc iframe. I counted live targets via the Chromium remote debugging endpoint (curl http://localhost:9222/json/list) before and after switching. Production displayed (index 0) 108 iframes Switched to a light page (index 1) 46 iframes Switched back to Production 108 iframes 62 controls are destroyed on leaving the page and re-instantiated on return. Observed latency was approximately 2.5 -5s away from the heavy page and approximately 4.0 -5 s back to it. This was measured with the panel otherwise idle: 2.8% system CPU, 97.1% idle, 2 h 56 min uptime, no remote-desktop session running, hardware acceleration confirmed active in chrome://gpu. I had previously measured the same behaviour under a much higher CPU load and have since resolved that load separately (VISU_TASK cycle period), so I am confident the rebuild is the frame lifecycle itself and not CPU starvation. Measurement 2 — frame offset instead of switch index I then displayed the same overlay page by a different mechanism. Instead of using a switch-frame index, I placed the page in a fixed Frame parked off-screen below the visible canvas, and drive its Y offset from an INT in Structured Text to move it into view. With this approach the overlay appears immediately, the production page underneath is never torn down and keeps updating, and no visualization is destroyed or rebuilt in either direction. The iframe count does not change at any point. This is the same visualization, containing the same HTML5 controls, as in Measurement 1 — the only difference is how it is brought on screen. So the rebuild appears to be a property of the switch-frame mechanism specifically, not of the page or its control count. Questions: Is the destroy-and-rebuild behavior on switch-frame the intended and documented lifecycle for WebVisu? Is there any setting, property or client option that causes a referenced visualization to remain instantiated when it is not the active index — the equivalent of keeping it mounted but not displayed? Does the runtime or client offer any form of caching or pre-instantiation for referenced visualizations, so that a return switch does not pay the full construction cost? Is the cost specific to HTML5 controls, or would the same rebuild occur with an equivalent number of native visualization elements? We ask because it would inform whether reducing our HTML5 control count is a viable solution. Is there a recommended pattern for showing a full-screen page over a live production screen without tearing the production screen down? My current workaround is to keep every page permanently instantiated and move it on and off screen by driving a frame offset variable, which avoids the rebuild entirely but means every page stays live and consumes client resources for the life of the session. This works, but I would prefer to use the supported mechanism if one exists. Any help on this is greatly appreciated. Thank you!
Last updated: 2026-08-07

Post by kevintumibay on Struggling to connect to EK1100 to Raspberry Pi CODESYS Forge talk (Post)
SUMMARIZED VERSION OF QUESTION: I'm trying to connect a Raspberry Pi running "Codesys Control for Raspberry Pi" to a Beckhoff EK1100, unfortunately, when I try to connect I get the following messages SEE FIRST PICTURE DETAILED VERSION OF QUESTION: Hi everyone, I'm a college student that is super interested in learning about PLCs. I wanted to dive into the subject and decided to follow this great Instructables article: https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/ Thank you in advance for your help! My current setup is as follows: 1. I have Codesys Control for Raspberry Pi, version 4.14.0.0, (https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html) installed on a Raspberry Pi 3B. 2. I am using my smartphone hotspot to create a network. 3. I have CODESYS 3.5 SP21 (64 bit) installed on my Windows 11 laptop. 4. Both the Raspberry Pi and my laptop are connected to the smartphone hotspot network (I am wirelessly connecting to the Raspberry Pi). Connecting to the Raspberry Pi from CODESYS on my laptop: 1. I launch Codesys Installer -> I install Codesys Control for Raspberry Pi (link to the software). 2. I launch Codesys 3.5 SP21 (64 bit) on my laptop. 3. I go to file --> new project --> standard project --> in the pop-up I select "Codesys Control for Raspberry Pi" and "Structured Text" 4. I click on tools -> Deploy Control SL (on older versions of Codesys you would click on "update Raspberry Pi", I got that information from this video: link) 5. Inside Deploy Control SL --> I go to the "communication" menu and I input the IP address of my Pi, the password, and click on connect. 6. Inside Deploy Control SL --> I go to the "deployment" menu and I install Codesys Control for Raspberry Pi SL and Codesys Edge Gateway for Linux 7. Now I double click on "device" in the left hand tree and put in the IP address of my Raspberry Pi and click on connect --> success! I am able to connect! SEE SECOND PICTURE Powering the EK1100 and connecting it to the Raspberry Pi: 1. I am supplying the EK1100 with 24 V across the + and - pins. 2. I have jumper wires going from the + pin to the 24V pin and from the - pin to the 0V pin. SEE THIRD PICTURE 4. I am pretty confident that the EK1100 is receiving power because the "LED Us 24 V" and "LED Up 24 V" are lighting up. 5. I then run an ethernet cable from the EK1100 to the Raspberry Pi port (the Raspberry Pi is connected to my laptop wirelessly over WiFi). I think this connection should also be good since the LINK/ACT LED lights up. Trying to connect to the EK1100: 1. Back in Codesys I right-click on "Device" in the left tree and then in the pop up I click on "add device". 2. I then click on EtherCAT Master. 3. Next in a terminal window I SSH into the raspberry Pi and run the "ifconfig" command. 4. From there I get the MAC address for eth0 --> in my case: b8:27:eb:29:a9:25 5. Then, back in Codesys I double click on "EtherCAT Master" in the left hand tree. I then paste the MAC address into the "Source Address (MAC)" field. 6. I go to the Beckhoff official website and download the XML files for EtherCAT: https://www.beckhoff.com/en-en/products/i-o/ethercat-terminals/ek1xxx-bk1xx0-ethercat-coupler/ek1100.html? 7. I unzip those files in my computer into some folder that I can remember. 8. Back in Codesys I click on "Tools" --> "Device Repository" --> "Install" --> and then on the "Beckhoff EK11xx.XML" file. 9. In theory the necessary XML file is now installed. 10. THIS IS WHERE I RUN INTO THE PROBLEM: I then click on login --> I right click on EtherCAT_Master and then scan for devices --> and nothing. 11. It just doesn't detect it. On top of this whenever I login I get those orange triangles on the left on my tree. When I check the Log I get the messages at the very first screenshot of this post. SEE FOURTH PICTURE Solutions that I have tried to resolve this problem: 1. I thought it was maybe the .XML file so I installed all the .XML files from the EtherCAT folder that I downloaded. That didn't fix it. 2. I went on the Wayback Machine and got the .XML files from 2018 as I thought maybe an older version would work. This file of EtherCAT folders had a .XML file named "Beckhoff EKxxxx.XML" I thought this would work because that's the name of the file the guy in the Instructables used (https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/). That didn't do anything. 3. I ran the PLC on my computer instead of the Raspberry Pi and tried to connect to the EK1100, in case the issue was with the Raspberry Pi, but I still ran into the same error from the picture above: "Attention! The device was not found in the repository. Vendorcode: 0x0. Productcode: 0x0. Revision: 0x0". SEE FIFTH PICTURE 4. I reinstalled Codesys, I was originally on version 3.5 SP20 when I did this, I upgraded to 3.5 SP21 with no success. 5. I then thought the solution might be to first add the EK1100 hardware before connecting so I did the following: 6. Right click on "EtherCAT Master" on the left hand tree --> then click on "add device" --> then I added the "EK1100 EtherCAT Coupler (2A E-Bus)" MY THEORY OF WHAT IS CAUSING THE PROBLEM: I asked ChatGPT for help and it said that it might have something to do with the revision number. On the physical EK1100 it says "Rev. Nr.: 0018". I believe that this means that I need to a revision 0018 XML file but if you look in Codesys it says the version is 16 (picture above). This is confusing because I got my .XML file from the official Codesys website so it should be the most up to date version possible. I searched and I searched and I couldn't find a version 18 .XML file, I don't even now if this exists. Any help you can provide is greatly appreciated, I don't know what to do anymore and I really really want to get this working. Thank you!
Last updated: 2025-03-30

Post by mogam on Internal error:System.NullReferenceException: The object reference was not set to an object instance. CODESYS Forge talk (Post)
Hi everyone, I have a my App that reads values from a shared memory than 2 variables x,y were calculated. here as you can see in my code: PROGRAM PLC_PRG VAR szName : STRING := '/SM'; ( Name of the shared memory.) uxiSize : __UXINT := 646 * 2 * SIZEOF(REAL); ( Size of the shared memory. ) hShm : RTS_IEC_HANDLE; ( Handle to the shared memory ) pStart : POINTER TO REAL; ( Pointer to the first element in the memory ) pData : POINTER TO REAL; ( Pointer, which is incremented until the last sign in the memory is reached. ) shared_data :ARRAY[0..645, 0..1] OF REAL; velocity : ARRAY[0..2] OF REAL; ( Velocity array ) position : ARRAY[0..2] OF REAL; ( Position array ) angleDepth : ARRAY[0..645, 0..1] OF REAL; ( Angle and depth array ) xEndOfMemory : BOOL; x : ARRAY[0..645] OF REAL := 1.0; y : ARRAY[0..645] OF REAL := 1.0; (* Result of actions at the memory. *) OpenResult : RTS_IEC_RESULT; ReadResult : RTS_IEC_RESULT; PointerResult : RTS_IEC_RESULT; DeleteResult : RTS_IEC_RESULT; CloseResult : RTS_IEC_RESULT; i : INT; END_VAR ( Open the shared memory ) hShm := SysSharedMemoryOpen2(szName, 0, ADR(uxiSize), ADR(OpenResult)); IF hShm <> RTS_INVALID_HANDLE THEN (* Read the entire shared memory table *) SysSharedMemoryRead(hShm:= hShm, ulOffset:= 0, pbyData:= ADR(shared_data), ulSize:= uxiSize, pResult:= ADR(ReadResult)); (* Fetch the pointer from the shared memory. The pointer is pointing to the first element address *) //pStart := SysSharedMemoryGetPointer(hShm, ADR(PointerResult)); (* Close the shared memory *) //CloseResult := SysSharedMemoryClose(hShm := hShm); (* Read velocity and position data from the shared memory *) FOR i := 0 TO 2 DO velocity[i] := shared_data[i, 0]; position[i] := shared_data[i, 1]; END_FOR; (* Read angle and depth data from the shared memory *) FOR i := 0 TO 645 DO angleDepth[i, 0] := shared_data[(i + 6), 0]; angleDepth[i, 1] := shared_data[(i + 6), 1]; END_FOR; FOR i := 0 TO 645 DO x[i] := angleDepth[i, 1]*COS(angleDepth[i, 0]); y[i] := angleDepth[i, 1]*SIN(angleDepth[i, 0]); END_FOR; END_IF For these values an XY-CHART needs to be done and when i create a visualisation and set the x data and y data when i try to compile, i recieve this error: ------ Übersetzungslauf gestartet: Applikation: Device.Read_App ------- Code typisieren ... [FEHLER] Internal error:System.NullReferenceException: Der Objektverweis wurde nicht auf eine Objektinstanz festgelegt. bei _3S.CoDeSys.LanguageModelManager.LDateType.Accept(ITypeVisitor typvis) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IArrayType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , _IPreCompileContext , _ICompileContext , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , Boolean , Boolean , _IPreCompileContext , _IPreCompileContext , _ICompileContext , Boolean , Boolean& , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(Guid , Boolean , Boolean , Boolean , Boolean& , _ICompileContext& , _ICompileContext& , IProgressCallback , Boolean , Boolean ) Kompilierung abgeschlossen -- 1 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 1 Fehler, 0 Warnungen : Kein Download möglich!
Last updated: 2024-05-24

Post by mogam on Internal error:System.NullReferenceException: The object reference was not set to an object instance. CODESYS Forge talk (Post)
Hi everyone, I have a my App that reads values from a shared memory than 2 variables x,y were calculated. here as you can see in my code: PROGRAM PLC_PRG VAR szName : STRING := '/SM'; ( Name of the shared memory.) uxiSize : __UXINT := 646 * 2 * SIZEOF(REAL); ( Size of the shared memory. ) hShm : RTS_IEC_HANDLE; ( Handle to the shared memory ) pStart : POINTER TO REAL; ( Pointer to the first element in the memory ) pData : POINTER TO REAL; ( Pointer, which is incremented until the last sign in the memory is reached. ) shared_data :ARRAY[0..645, 0..1] OF REAL; velocity : ARRAY[0..2] OF REAL; ( Velocity array ) position : ARRAY[0..2] OF REAL; ( Position array ) angleDepth : ARRAY[0..645, 0..1] OF REAL; ( Angle and depth array ) xEndOfMemory : BOOL; x : ARRAY[0..645] OF REAL := 1.0; y : ARRAY[0..645] OF REAL := 1.0; (* Result of actions at the memory. *) OpenResult : RTS_IEC_RESULT; ReadResult : RTS_IEC_RESULT; PointerResult : RTS_IEC_RESULT; DeleteResult : RTS_IEC_RESULT; CloseResult : RTS_IEC_RESULT; i : INT; END_VAR ( Open the shared memory ) hShm := SysSharedMemoryOpen2(szName, 0, ADR(uxiSize), ADR(OpenResult)); IF hShm <> RTS_INVALID_HANDLE THEN (* Read the entire shared memory table *) SysSharedMemoryRead(hShm:= hShm, ulOffset:= 0, pbyData:= ADR(shared_data), ulSize:= uxiSize, pResult:= ADR(ReadResult)); (* Fetch the pointer from the shared memory. The pointer is pointing to the first element address *) //pStart := SysSharedMemoryGetPointer(hShm, ADR(PointerResult)); (* Close the shared memory *) //CloseResult := SysSharedMemoryClose(hShm := hShm); (* Read velocity and position data from the shared memory *) FOR i := 0 TO 2 DO velocity[i] := shared_data[i, 0]; position[i] := shared_data[i, 1]; END_FOR; (* Read angle and depth data from the shared memory *) FOR i := 0 TO 645 DO angleDepth[i, 0] := shared_data[(i + 6), 0]; angleDepth[i, 1] := shared_data[(i + 6), 1]; END_FOR; FOR i := 0 TO 645 DO x[i] := angleDepth[i, 1]*COS(angleDepth[i, 0]); y[i] := angleDepth[i, 1]*SIN(angleDepth[i, 0]); END_FOR; END_IF For these values an XY-CHART needs to be done and when i create a visualisation and set the x data and y data when i try to compile, i recieve this error: ------ Übersetzungslauf gestartet: Applikation: Device.Read_App ------- Code typisieren ... [FEHLER] Internal error:System.NullReferenceException: Der Objektverweis wurde nicht auf eine Objektinstanz festgelegt. bei _3S.CoDeSys.LanguageModelManager.LDateType.Accept(ITypeVisitor typvis) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IArrayType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , _IPreCompileContext , _ICompileContext , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , Boolean , Boolean , _IPreCompileContext , _IPreCompileContext , _ICompileContext , Boolean , Boolean& , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(Guid , Boolean , Boolean , Boolean , Boolean& , _ICompileContext& , _ICompileContext& , IProgressCallback , Boolean , Boolean ) Kompilierung abgeschlossen -- 1 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 1 Fehler, 0 Warnungen : Kein Download möglich!
Last updated: 2024-05-24

Post by brouwyka on JSONByteArrayWriter string result incorrect order CODESYS Forge talk (Post)
Hello everybody! We are currently working on implementing a call to an API that tracks data sent to it through a JSON body. Versions: CODESYS V3.5 SP19 Patch 7 using IIOT Libraries SL license, specifically JSON Utilities SL version 1.13.0.0. For simplicity, let's say we want to construct the following JSON body for our request (simplified to just 1 key-value pair in each of the array objects to keep things shorter, but we'd have multiple fields in each in reality): { "id": "machine_1", "readings": [ { "temp_mid": 153.8 }, { "temp_mid": 98.3 } ], "status": "RUNNING" } However, our "readings" data is added over time, not in creation, so calls to the builder would be somewhat out of order. In a simplified manner, our calls would look like this: jsonBuilder(pJsonData := JsonData, diRootObj => rootJsonIndex); // rootJsonIndex = 0. // Set "id" at root JSON object. wsValue := "machine_1"; jsonBuilder.SetKeyWithValue("id", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 1, VALUE: diParentIndex = 1 & diIndex = 2. // ... Time passes, we get our first reading to add ... // The "readings" array does not exist yet, so we make it first at root JSON object before adding our first reading. readingsJsonArrayIndex := jsonBuilder.SetKeyWithArray("readings", diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 3, VALUE: diParentIndex = 3 & diIndex = 4. // Then add the first reading, for which we first have to make an object. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 5. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the first object in the array. rValue := 153.8; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := readingsJsonArrayObjectIndex); // JSONData KEY: diParentIndex = 5 & diIndex = 6, VALUE: diParentIndex = 6 & diIndex = 7. // ... Time passes, we want to add another root-JSON-level field ... // Set "status" at root JSON object. wsValue := "RUNNING"; jsonBuilder.SetKeyWithValue("status", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 0 & diIndex = 8, VALUE: diParentIndex = 8 & diIndex = 9. // ... Time passes, we want to add a second reading ... // "readings" array exists, so add the second reading, but first we have to make another object. // NOTE the re-use of the earlier stored `readingsJsonArrayIndex`, so we add the new object to that previously created array. readingsJsonArrayObjectIndex := jsonBuilder.SetObject(diParentIndex := readingsJsonArrayIndex); // JSONData OBJECT: diParentIndex = 4 & diIndex = 10. // And then we add the field(s) in the object for the first reading. // NOTE the use of `readingsJsonArrayObjectIndex` so we set the field(s) in the SECOND(, new) object in the array. rValue := 98.3; jsonBuilder.SetKeyWithValue("temp_mid", wsValue, diParentIndex := rootJsonIndex); // JSONData KEY: diParentIndex = 10 & diIndex = 11, VALUE: diParentIndex = 11 & diIndex = 12. // ... Finally, we want to send to the API, so we must convert the builder to data the client accepts as a body ... xTestWriteToJsonArray := TRUE; jsonArrayWriter( xExecute := xTestWriteToJsonArray, pwData := ADR(jsonDataString), udiSize := SIZEOF(jsonDataString), jsonData := JsonData^ ); IF jsonArrayWriter.xDone THEN // The writer was successful, the `jsonDataString` VAR should now contain a WString copy of the JSON object from the builder. xTestWriteToJsonArray := FALSE; END_IF We see that the JsonData STRUCT is correctly organised (in terms of the diParentIndex & diIndex set by it for each JsonElement) as we expect, as outlined in my comments in the simplified code above. However, as soon as we pass it to the jsonArrayWriter (which is a JSON.JSONByteArrayWriter), the resulting jsonDataString does not match our expectations, instead coming out like this: { "id": "machine_1", "readings": [ { "temp_mid": 153.8 } ] } { "temp_mid": 98.3 } "status": "RUNNING" The behaviour of the JSONByteArrayWriter thus seems to be the problem here. It does not seem to correctly process the children of JsonElements that are ARRAYs when additions to them are done broken up by additions to the lower level JSON OBJECT they are a part of. We have confirmed this by changing the order of the calls in our example to add both readings before adding the "status", in which case we get our expected outcome. However, in reality this is not possible for us - additions to any of the JSON's objects, arrays or array objects may happen at any time after other fields elsewhere in the JSON have been added. Does anyone know a way around this, a fix, or knows a solution we simply have not found? This same phenomenon was also noted on this forum by user @ryusoup at the end of 2023 (https://forge.codesys.com/forge/talk/Engineering/thread/c45929e2f1/#e27f) and user @mtho in early 2024 (https://forge.codesys.com/forge/talk/Engineering/thread/cd1bb450db/#1292) but both topics received no activity beyond both users' opening posts. Looking through the release notes of all the versions of the JSON Utilities SL library, I also did not see any remarks on resolutions of bugs in this vain. Thanks in advance for the assistance!
Last updated: 2026-06-10

<< < 1 .. 50 51 52 53 54 > >> (Page 52 of 54)

Showing results of 1347

Sort by relevance or date