Search talk: rx error count

 
<< < 1 .. 52 53 54 55 56 57 > >> (Page 54 of 57)

Post by mariusz997 on Visualisation - internal error CODESYS Forge talk (Post)
Hi everyone. I try to reach Codesys but I have problem on the beginning. I use Codesys 3.5.18.60 and 3.5.18.30 . On both version I have this same problem - when I create new standard project with controller Control Win v3 x64, empty PLC program - I compile it and everything is ok. But when I add visualisation without any elements and compile it - I get: ~~~ ------ Build started: Application: Device.Application ------- Typify code... Generate code... Generate global initializations... [WARNING] SortingStation: HMI Device: PLC Logic: Application: Missing element configuration. Element may not be usable. [WARNING] SortingStation: fbOutletConveyour Device: PLC Logic: Application: C0196: Implicit conversion from unsigned Type 'WORD' to signed Type 'INT' : Possible change of sign [ERROR] Internal error:System.NullReferenceException: Odwołanie do obiektu nie zostało ustawione na wystąpienie obiektu (in english: Object reference not set to an instance of an object.). w _3S.CoDeSys.Codex86_64.V351500.CPUx86_64.CodeStore(TypeClass tc, Register RegBase, Register RegIndex, Int32 nOffset, Register RegSrc, Int32 nScale) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.GenerateVarAbsolut(IVariableExpression varexp, Int32 iArea, Int32 nAddress, IIndexInfo indexinfo, ICompiledType ctype, Int32 nTypeSize, IAccessMode am) w ..(_IVariableExpression ) w ..(IExprement ) w ..(IExprement ) w ..(_ICompoAccessExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IAssignmentExpression assign) w ..(_IAssignmentExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IExpressionStatement expstat) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, ISequenceStatement mainRoutine, Boolean bKeepCompileInformation, IEnumerable`1 subroutines) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, Boolean bKeepCompileInformation) w ..(_ICompiledPOU ) w _3S.CoDeSys.Compiler35180.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) w ..(_ICompiledPOU , Boolean , Boolean , _ICompileContext , _ICompileContext , Boolean , Codegeneration , Boolean& , Boolean , Boolean ) w ..(Boolean , Boolean , _ICompileContext , _ICompileContext , InitExitSignatureInfo , Boolean , Codegeneration , _ISignature , Boolean& , Boolean , Boolean ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature , InitExitSignatureInfo& , Boolean& ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(ICodegenerator ) w ..() w ..() Build complete -- 1 errors, 2 warnings : No download possible ~~~ Could someone help me with this problem? Thank you in advance Mariusz
Last updated: 2025-11-11

Post by sahin6033 on DSE M840-001-02: DSEServiceTool transfers CodesysApp.pkg successfully, but device shows “No application loaded CODESYS Forge talk (Post)
Hi, I am trying to load a test application into a DSE M840-001-02 display, but after reboot the device still shows: “No application loaded” I would like to understand whether the problem is in my project, the package creation process, or firmware/runtime compatibility. Hardware Device: DSE M840-001-02 Firmware used: M840 MKII Firmware File v4.1.2 Software CODESYS V3.5 SP12 (32-bit) DSE CODESYS Package v1.5.44 DSEServiceTool What I did Created a new empty Standard Project Selected target/template: M840-02 V4.1 Used a minimal ST program only: PROGRAM PLC_PRG VAR xAlive : BOOL := TRUE; END_VAR Confirmed: project builds PLC_PRG is assigned to MainTask created Boot Application Generated CodesysApp.pkg Put the M840 into bootloader mode Sent the package using DSEServiceTool DSEServiceTool result Transfer completes successfully and I get: connection accepted 100% download package ACK <status>OK</status> ** Example log:** Searching for controllers.... sendPackageToController: waiting for incoming data connection... sendPackageToController: connection accepted... <status>Downloading</status> <percent>20</percent> <percent>40</percent> <percent>90</percent> <percent>100</percent> sendPackageToController: sent 112cb8 bytes OK Package ...\CodesysApp.pkg transferred to controller c0a80101 OK sendPackageToController: package ACK <status>OK</status> Actual result After reboot, the display still shows: “No application loaded” Additional issue I also saw earlier At one stage I also had these fatal errors in CODESYS: [FATAL ERROR] Unresolved reference: 'IOMGRLOCKENTER' [FATAL ERROR] Unresolved reference: 'IOMGRLOCKLEAVE' I checked library versions and adjusted them to: IoDrvBase = 3.5.5.0 IoStandard = 3.5.10.0 Also, I am using CODESYS SP12, which I understand is the correct version for DSE M840. My questions If DSEServiceTool shows Status OK and package ACK, but the device still says “No application loaded”, does that mean: the .pkg was transferred but not accepted as a valid application? the package was built incorrectly? the boot application / runtime / firmware versions are still mismatched? What is the correct procedure to generate CodesysApp.pkg for M840-02 V4.1? Is there any known compatibility issue between: DSE CODESYS Package 1.5.44 M840 MKII Firmware 4.1.2 CODESYS 3.5 SP12 Has anyone successfully loaded even a minimal empty test project into M840-001-02, and if so, what exact versions/process did you use? Any help would be appreciated.
Last updated: 2026-03-17

Post by winki on ModbusFB ClientRequest: never recovers after a single ReplyTimeout (requires full download) CODESYS Forge talk (Post)
Library: ModbusFB (CODESYS Modbus package) IDE / Runtime: CODESYS V3.5 SP___ / Control runtime ___ Target: ___ (e.g. gateway, Linux ARM64 / Debian) Slave: Modbus TCP inverter Summary I poll a Modbus TCP slave with a permanent connection: one ClientTCP (kept connected, xConnect:=TRUE) and one ClientRequestReadHoldingRegisters, triggered cyclically. Everything works fine after a fresh application download. But as soon as one single ReplyTimeout occurs (slave temporarily not answering), the request never recovers. It stays stuck and no further messages are sent, even though the TCP connection is still reported as alive. Only a full application download brings it back — an online change or a runtime reset is not enough / not what I want in production. State observed when stuck So the connection is alive, the request finished in ReplyTimeout, the FB is back to _state = None, but udiNumMsgSent no longer increases — as if a new rising edge on xExecute is no longer accepted / no longer produces a new message. My trigger logic (simplified) Each PLC cycle, in this order: If the request is fully at rest (NOT xExecute AND NOT xBusy AND NOT xDone AND NOT xError) and a read is pending, I set xExecute := TRUE. I call clientTcp() then clientRequest(rClient := clientTcp) once each, per cycle. On xDone or xError, I set xExecute := FALSE. I made sure to insert at least one full cycle with xExecute = FALSE (seen by the FB call) before re-triggering, so the falling edge is processed. Questions After a ReplyTimeout (xError = TRUE), what is the exact, correct sequence to re-trigger the same ClientRequest so a new message is actually sent again? Is a full cycle with xExecute = FALSE between two executions mandatory? Is there a known condition where, after ReplyTimeout, the ClientTCP keeps xConnected = TRUE but silently stops sending new requests (e.g. an internal request queue / _udiRequestId that gets out of sync)? udiNumMsgSent freezing at 23 while the FB shows _state = None is what puzzles me. Is the recommended pattern to drop the connection (ClientTCP.xConnect := FALSE for one cycle, then TRUE) on a request error, rather than keeping it alive? The docs state a request error does not close the connection, so I kept it open — but maybe that is the issue here. Could the large uiStartItem (50514) be relevant? It works right after download, so addressing seems correct, but I want to rule it out. Any guidance on the canonical recovery pattern after a request timeout would be greatly appreciated. Thanks!
Last updated: 2026-06-19

Post by adamrobotic on llcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008 CODESYS Forge talk (Post)
Hi All, Recently I have been experiencing a issue in CodeSys SP16 Patch 3, with a exception which comes up after I have made several online changes. callcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008, after I experience this fault then I receive a error message for any subsequent online change "online change failed, no task gap within 10000ms". To recover either the controller needs a orgin reset, which will allow online edits thereafter until falling back into the loop. I am using a TURCK TX707 product which is controlling robot trajectory, We have hard coded the coordinate data rather than using persistence variables so hence the need to do online changes consistently. I have read on the forum other people have experienced similar issue with the online task gap, but I have no task which have same priority and also monitored the CPU usage and have not seen it go above 13%. Anyones help would be much appreciated, thankyou.
Last updated: 2023-08-18

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17

Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win CODESYS Forge talk (Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04

Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs CODESYS Forge talk (Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11

Post by berto on Opening PDF in Web Browser in Target Visu HMI CODESYS Forge talk (Post)
Hi everybody, I've been facing problems with the PDF visualization in Web Browser. I am trying to open a pdf file called 'sample.pdf' which I manually saved inside PlcLogic/visu folder. I am setting the web browser URL as: 'http://127.0.0.1:8080/sample.pdf' but I get 'refused connection'. I got a similar error trying to open https sites and I discovered that I can only open http websites. Opening 'http://de.wikipedia.org' everything works fine. I also tried to check using code whether the sample.pdf is present in the directory. Unfortunately, when I try to read directories of 'PlcLogic' I get file FILE_OPERATION_DENIED (I am using File.DirList). I would like to be able to open PDF files in web browser. Possibly to move new PDF files in the folder as my customer wants to display different pdf manuals on the hmi. Here you find some screenshots and my .project. I am using Codesys 3.5.19.70. Best regards, Berto
Last updated: 2024-07-11

Post by faceplant on CmpDynamicText unresolved references CODESYS Forge talk (Post)
Hello! I am new to codesys so I am sorry if this is not the right place to ask this question. I am using codesys V3.5 SP20 Patch 1 + (64-bit) and a Groov EPIC PLC (GRV-EPIC-PR2). I am trying to build and deploy my application to the PLC, but when I log in I get 6 errors (codesys_error.png). It seems that the errors have to do with the CmpDynamicText system library which I have as version 3.5.20.0. I have tried to add CmpDynamicText to the ComponentManager section in the PLC's CODESYSControl.cfg file as described in this forum post and still hit the same error. I noticed that the library is grayed out in the library manager, which I think might be the issue. However I don't remember if it was grayed out before I encountered this issue. Please let me know if I can provide anymore info. Thank you!!!
Last updated: 2024-07-19

Post by denkihitsuji on Content update through Data URI on Web Brower on Visualization Toolbox CODESYS Forge talk (Post)
Objective: I want to dynamically update the content with strings and JPEG images received from a TCP/IP socket. For this purpose, I am exploring the possibility of utilizing the Web Browser feature of the Visualization toolbox. Example: In a standard web browser, entering data:text/plain;charset=utf-8;base64,SGVsbG8gc3RyYW5nZXI= in the URL window will display "Hello stranger" on the webpage. Issue: When attempting to use this method in the Web Browser of the Visualization toolbox, the content does not display as expected. Instead, it shows the error:'Navigation to the webpage was canceled.'. Request: I seek guidance on how to resolve this issue so that the Web Browser in the Visualization toolbox correctly interprets and displays the data URI content. Alternative Solution Welcomed: Or, if it is possible to directly use Codesys Structured Text (ST) variables within an HTML page, this approach would also meet my requirements. Thank you for your attention.
Last updated: 2024-07-30

Post by mubeta on parker servo and position CODESYS Forge talk (Post)
In general, drives have parameter sets to adjust behaviour in such cases: position recovery, adaptation with resistant torque, out-of-position window failure, etc. (Much depends on the type of configuration set for the axis: positioner, speed controller, torque controller, etc.). I have used that type of drive very little, in only two cases and a long time ago. To tell you what is normal is impossible. I know by reputation they are very simple objects, without too many pretensions and adjustments possible. Try running traces by monitoring actual position, motor current, torque and following error. These are the most sensible curves to understand what is going on. Maybe by fine tuning the motor tuning, the current controller or the speed controller you will get something closer to what you want. For example, from DS, the motor has a standstill torque of 3 Nm. Observe with traces whether this is effective: motor current trend. And afterwards, when you have your own accurate picture of the situation, you can also hear from the product's local support to see if you can steal a few more things from it performance-wise.
Last updated: 2024-08-05

Post by mainak on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
Hello all, I am using the OPC UA server with my custom information model. I have used the communication manager to add my information model under my application and created instances from OPC UA types. I see that the created instances in the OPC UA server has some opaque nodeid (attached screenshot) and I want to change that. Therefore I have the following questions: 1. Is there a way to configure the NodeIds of instances in the OPC UA server? I tried to edit it using the UaExpert client but got error "BadNotWriteable". is it possible to configure it somewhere so that the nodeids can be changed using an external client? 2. Is there a way to define the rule for creating instance nodeids within the codesys IDE? 3. Is it possible to create the instances before e.g. using a modelling tool like UaModeler and import them as part of the information model and use them later? Using the communication manager, I can only create instances from types. I couldn't find a way to map my existing instances to plc tags from my application. It would be nice if someone could help me with these issues. Thanks in advance. :)
Last updated: 2024-10-19

Post by koerbejm on Probleme beim aktivieren von Lizenzen CODESYS Forge talk (Post)
Liebe Codesys-Gemeinde, ich habe folgendes Problem und bitte um Hilfe: Um eine auf meinem dem Raspberry Pi laufende Steuerung ohne große Mühe duplizieren zu können, habe ich mir ein Image der SD Karte mit Win32 Diskimager erstellt. Dieses konnte ich bisher ohne weitere Probleme auf eine weitere Micro-SD karte ausrollen. Anschließend habe ich mich via Putty auf den PI geschaltet, die vorherige Lizenz (die ja für den vorheringen PI zulässig war) gelöscht über - sudo su - rm -r /var/opt/codesys/cmact_licenses/ - reboot Um dann via Codesys 3.5 SP16 Patch 4 eine neue Lizenznummer ">>Tools>Lizenzmanager>Lizenz aktivieren" zu aktivieren und das wars. Durch die Umstellung des Lizensierungsverfahrens klappt diese Variante nun nicht mehr. Ich habe mir neue Lizenzen von Codesys gekauf, doch sobald ich diese in die Ticket-ID eintrage und aktivieren möchte bekomme ich folgende Fehlermeldung: ReturnCode: 403046401, An internal error has occured. Please try it again later. (siehe Bild im Anhang "Fehler_Codesys3.5V16.png") Ich habe dann meine Codesys-Version auf Version 3.5 SP20 geupdated und das selbe versucht mit dem Resultat, dass ich nun folgende Fehlermeldung erhalte: "Der ausgewählte Container "...." paßt nicht zu Ihrem Ticket. Bitte wählen Sie einen passenden aus." --> Siehe Bild im Anhang "Fehler_Codesys3.5V120.png" Was genau kann/muss ich tun, damit ich einfach wie bisher meine Steuerungen duplizieren kann? Verwendete Hardware: Raspberry Pi 3 Model B+ Verwendete Lizenz: Codesys Control Basic L Viele Grüße und Danke, Jan
Last updated: 2024-10-23

Post by edvard-munch on How I can get "Done flag" for "Modbus Slave Channel"? CODESYS Forge talk (Post)
This is from 10 years ago, I know. But I have been using (SLAVE_DEVICE.iChannelIndex = CHANNEL_NUMBER) AND (SLAVE_DEVICE.xDone) I suppose that it shows xDone for the channel that shows up in the iChannelIndex at the same cycle? It seems to be working properly for two devices that I have been using it before But now I have another device and using two write channels, for one register each. One channel works properly and returns DONE flag When another channel is triggered, I see that it shows up in iChannelIndex, but flag DONE not received, but no Error for the channel. Also, when i check the register in the device it's evident that data has been transferred. Is this could happen sometimes with CODESYS, so DONE flag not received? Or this is a problem with a given device? With this certain register
Last updated: 2024-12-19

Post by atcprojectteam on Modbus Function Code 15, writing multiple coils CODESYS Forge talk (Post)
Hi all, I am using an RSTI-EP I/O card along with the EPXMBE101 Modbus/TCP network adapter. I have a Control Standard L license. I successfully connected to the I/O card via Modbus and can read inputs without any issues. However, when I try to write to the digital output modules using function code 15, I am unable to make any changes. Here’s what I have done so far: I created a small project using Structured Text. I set up Modbus channels (as shown in the attached image) and mapped the pins. When I use cyclic mode, the connection results in an error. However, when I use the rising edge, the connection works, but I don’t see any changes on the I/O card. For the output module, I assigned one bit to high. After that, I ran CODESYS Control Win V3. (Should I be running the PLC as well?) I built the program, but I am not receiving any response from the I/O card. Could you please advise on what might be causing this issue?
Last updated: 2025-02-26

Post by atcprojectteam on Modbus Function Code 15, writing multiple coils CODESYS Forge talk (Post)
Hi all, I am using an RSTI-EP I/O card along with the EPXMBE101 Modbus/TCP network adapter. I have a Control Standard L license. I successfully connected to the I/O card via Modbus and can read inputs without any issues. However, when I try to write to the digital output modules using function code 15, I am unable to make any changes. Here’s what I have done so far: I created a small project using Structured Text. I set up Modbus channels (as shown in the attached image) and mapped the pins. When I use cyclic mode, the connection results in an error. However, when I use the rising edge, the connection works, but I don’t see any changes on the I/O card. For the output module, I assigned one bit to high. After that, I ran CODESYS Control Win V3. (Should I be running the PLC as well?) I built the program, but I am not receiving any response from the I/O card. Could you please advise on what might be causing this issue?
Last updated: 2025-02-26

Post by macman on Codesys 3.5 OPC UA Client to Kepware OPC UA Server CODESYS Forge talk (Post)
Hi, I have problem with connecting Wago PLC WAGO 750-8212/0025-0002 configured as OPC UA client to Kepware OPC UA Server. I am using Codesys 3.5.19.70. What I did so far. To the Codesys project I added object Data Source Manager and configured connection OPC UA like below: pic 1 Then I can browse the OPC server tags in “Variables” tab after prior trust on the server side of the client certificate created in the “Communication” tab: pic 2 Additionally second certificate has been created in Codesys for runtime process in “Security screen” as well as the server certificate was approved here: pic 3 But when I compiled project, downloaded it to PLC and go to RUN I can’t read selected in “Variables” tab, OPC Server tags. I am getting such error (ID: 7001): pic 4 All two PLC certificates has been trusted in OPC server (Kepware) side: pic 5 and Kepware server configuration look like this: pic 6 I can easily connect using third party OPC UA client UaExpert to Kepware server without problem. In attachment I added also log from Kepware OPC UA server. pic # - this specifies the number of a concrete graphic from one of the collective in attachment
Last updated: 2025-04-02

Post by jeroenaero on Problem with CodeSys Control SL Deploy Tool 4.15.0.0 CODESYS Forge talk (Post)
Hello, We just installed the new version of CodeSys Control SL Deploy Tool 4.15.0.0 but we get the following error when we try to add a VPLC. Can someone of the CodeSys team fix this issue? the object reference is not set to an instance of the object Zie het einde van dit bericht voor meer informatie over het aanroepen van JIT-foutopsporing (Just In Time) in plaats van dit dialoogvenster. ** Tekst van uitzondering ** System.NullReferenceException: De objectverwijzing is niet op een exemplaar van een object ingesteld. bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm.ShowAllImages() bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm..ctor(List1 virtualControls, List1 existingNames) bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.OnAddInstanceClick() bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.bt_add_Click(Object sender, EventArgs e) bij System.Windows.Forms.ToolStripItem.RaiseEvent(Object key, EventArgs e) bij System.Windows.Forms.ToolStripButton.OnClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleMouseUp(MouseEventArgs e) bij System.Windows.Forms.ToolStripItem.FireEventInteractive(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStripItem.FireEvent(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStrip.OnMouseUp(MouseEventArgs mea) bij System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) bij System.Windows.Forms.Control.WndProc(Message& m) bij System.Windows.Forms.ScrollableControl.WndProc(Message& m) bij System.Windows.Forms.ToolStrip.WndProc(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) bij System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Geladen assembly's ** mscorlib Assembly-versie: 4.0.0.0 Win32-versie: 4.8.9300.0 built by: NET481REL1LAST_C
Last updated: 2025-04-24

Post by bmatlove on Variable Length Array - Cannot mix variable and fixed length dimensions? CODESYS Forge talk (Post)
Using Codesys 3.5.18.30 I am trying to work with an array of variable length in one dimension, but known in the other dimension. For example, using an array that represents a list of items, each with an attribute profile. I do not know how many items will be in the list, but I know that every item has 5 attributes, like size, weight, etc. Codesys does not seem to be able to accept this. I have referenced Data Type: ARRAY OF documentation page, which is not explicit if variable & fixed length array dimensions can be mixed. In the VAR_IN_OUT scope, I initially tried MY_ARRAY : ARRAY [*, *] OF REAL; which was no problem, of course. I then modified it to MY_ARRAY : ARRAY [*, 1..5] OF REAL; which throws C0006: ', or ]' expected instead of '..' among consequent downstream errors. I then used the Auto Declare -> Array Wizard, which accepted (asterisk)-(asterisk) and 1-5 for 2-dimensional lower and upper bounds. It output: MY_ARRAY: ARRAY[*..*, 1..6] OF INT; which throws the same error stream. What's the deal here? Is this possible?
Last updated: 2025-05-23

Post by laurits on Max lines of code, codesys CNC ? CODESYS Forge talk (Post)
Hi, okay here's the project, it's a modified version of "CNC Example 10: Programming Dynamic CNC Paths", no need for G Code text file (i have also tried with G code text file, same problem) in "PROGRAM PLC_PRG" you can set bStart to true, and the program should start running, go to "PROGRAM CNC" and you can see axis moving. lrXpos := IoConfig_Globals.XAixs.fSetPosition; lrYpos := IoConfig_Globals.YAxis.fSetPosition; Now you can can change the number of movements in the the "PROGRAM PLC_PRG" From this number of movements in "program PLC_PRG" BUF : ARRAY[0..32010] OF SMC_GEOINFO; xp : ARRAY[1..32000] OF REAL; yp : ARRAY[1..32000] OF REAL; to this number to this number of movements BUF : ARRAY[0..132010] OF SMC_GEOINFO; xp : ARRAY[1..132000] OF REAL; yp : ARRAY[1..132000] OF REAL; Now if you start the program again you should see an error in the "sMC_Interpolator: SM3_CNC.SMC_Interpolator;" function block Let me know if you can not get it running.
Last updated: 2025-06-03

Post by pouyavakili on Execute Codesys Tests with python CODESYS Forge talk (Post)
❓ Issue: TestManager Not Available in Python Script (AttributeError) 🙏 Question: Why does project.get_testmanager() not work in scripting, even though Test Manager is installed and licensed, and the script runs in GUI mode? Is there a way to ensure the Test Manager interface is loaded or accessible from the scripting environment? 🧠 Summary: I'm trying to automate test execution using the CODESYS scripting engine (Python) via a script that opens a project, builds the application, and runs tests from a TestRepository.xml. Although the Test Manager works manually in the IDE, it fails when accessed via script with the following error: AttributeError: 'ScriptObject' object has no attribute 'testmanager' 🧪 Test Setup: CODESYS version: 3.5.21.10 Test Manager: Installed and licensed (works in the IDE manually) Project: Contains a test repository, which can be executed via the GUI Script execution method: powershell Start-Process -FilePath "C:\Program Files\CODESYS 3.5.21.10\CODESYS\Common\CODESYS.exe" ` -ArgumentList @( '--profile="CODESYS V3.5 SP21 Patch 1"', '--runscript="C:\Scripts\run_tests.py"' ) -Wait 📜 Script Summary: python project = projects.open(project_path) application = project.active_application application.build() This fails: testmanager = project.get_testmanager() ❗ Problem: Calling project.get_testmanager() or application.testmanager throws an AttributeError, even though the same project and test repository work in the GUI.
Last updated: 2025-07-23

Post by nicetuxedo on Can not activate license on Raspberry pi CODESYS Forge talk (Post)
Hello everyone, I'm hoping for some assistance with a license activation issue: a software crash has left my license in a strange state. Here is the sequence of events: I purchased a new license for the Raspberry PI from the official CODESYS web store. I opened the CODESYS and started the online activation process using the ticket number I received. During the activation, the CODESYS software threw an exception and crashed. I was not able to see if the activation completed. After restarting CODESYS, I attempted to run the activation process again with the same ticket number. The License Manager now gives me an error stating that the ticket has already been activated/used. I am now stuck because my installation is not licensed, but the activation server believes my ticket has been consumed. Has anyone encountered this before? Is there a way to have the ticket status reset?
Last updated: 2025-10-08

Post by forest on SM Drive license error CODESYS Forge talk (Post)
Hi, when it comes about license, I used INVTmatic Studio, which uses Codesys, for programming INVT plc. I bought Codesys Modbus license, it was not expensive, and then realised that INVT didn't have License Manager option (greyed out in program) which is needed for using of Codesys License. I contacted support from INVT, but developers told me that option is still not available. So depending on environment for programming Codesys, you can or not use Modbus license. Good thing about this version of Modbus TCP it works both direction. I could send commands and receive feedbacks from drive. But communication stops after 30 mins. So I used simple version of ethernet modbus which is somewhere in INVT or Condesys library (I can check tomorrow) which works only one way. I could send cmd to drive, and control it, but didn't have any feedback, like some readings back in PLC. which is bad, but at least I could start it and it didn't fail after 30 mins.
Last updated: 2024-01-10

Post by wbj0t on System libs and I/O Drivers CODESYS Forge talk (Post)
Hi everyone. My question about: where I can learn (read or watch) an info about codesys workflow through the system IO libs? I want to know how to implement I/O drivers by my self. In the system libs I see many interfaces, methods etc... But there is no explanation about them, just names of methods and fields of the FBs. I know about this page: https://forge.codesys.com/drv/io-drivers/doc/Generic/ There is so BIG the device description file and not so clear explaining of the attributes and elements, also some elements or attributes missed at it all. Yes, there are code examples on this page, but, so shortly and, for example, code about Modbus drivers is absent. And even if I try to add the IoDrvFB with lib, I get and error, something like: "failed to load IoDrvFB driver". And what about the book of codesys that written by Gary Pratt? Is there information about system libs and drivers in this book more clearly? Thank you :)
Last updated: 2024-02-02

Post by fredsta on Unable to load dynamic modules (Download failed: Application=Application) CODESYS Forge talk (Post)
Hey there, I am currently trying to find a good solution for the communication between CODESYS Control on Raspberry Pi and "the rest of the world", i. e. the things apart from CODESYS on my linux. My first approach was to use the c-integration. So I created a lib, defined extern fbs, compiled the code on my Pi using the SDK and put the .so into my lib project. When I try to log into the Pi and load the program, I get the error message which you can see in the attached picture. "Die dynamischen Module der C-Integration konnten nicht auf das Laufzeitsystem geladen werden" is german and means roughly "the modules from the c-integration could not be loaded onto the runtime system." Is this normal? Am I doing something wrong? I will have a look at the unix domain socket thing next, as I am still in the process of finding the best solution for the communication.
Last updated: 2024-02-15

<< < 1 .. 52 53 54 55 56 57 > >> (Page 54 of 57)

Showing results of 1404

Sort by relevance or date