Search talk: Object reference not set to an instance of an object

 
<< < 1 .. 55 56 57 58 59 .. 234 > >> (Page 57 of 234)

Retreive Port Number of UDP Client connected to my UDP Server CODESYS Forge talk (Thread)
Retreive Port Number of UDP Client connected to my UDP Server
Last updated: 2020-11-24

[SOLVED] Is it possible to maintain values of pre-existing GVL variables over code releases? CODESYS Forge talk (Thread)
[SOLVED] Is it possible to maintain values of pre-existing GVL variables over code releases?
Last updated: 2020-02-24

I would like to make use of PWM function on my Raspberry pi with CODESYS. CODESYS Forge talk (Thread)
I would like to make use of PWM function on my Raspberry pi with CODESYS.
Last updated: 2020-07-09

Code for reading 4 address to get 1 value of sensor (Ethernet IP) CODESYS Forge talk (Thread)
Code for reading 4 address to get 1 value of sensor (Ethernet IP)
Last updated: 2024-05-06

Post by simonep on new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Post)
I am trying to load a GSDML file of a PROFINET gateway device
Last updated: 2024-05-20

Post by simonep on new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Post)
I am trying to load a GSDML file of a PROFINET gateway device
Last updated: 2024-05-20

Post by simonep on new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Post)
I am trying to load a GSDML file of a PROFINET gateway device
Last updated: 2024-05-20

Post by simonep on new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Post)
I am trying to load a GSDML file of a PROFINET gateway device
Last updated: 2024-05-20

new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Thread)
new version of CODESYS have problem to load GSDML files
Last updated: 2024-05-20

Post by simonep on new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Post)
I am trying to load a GSDML file of a PROFINET gateway device
Last updated: 2024-05-20

Post by simonep on new version of CODESYS have problem to load GSDML files CODESYS Forge talk (Post)
I am trying to load a GSDML file of a PROFINET gateway device
Last updated: 2024-05-20

Post by pernockham on Persistence Manager: Config File not found? CODESYS Forge talk (Post)
Trying to utilize the persistence manager, but system do not write to file and do not create the config file. System is a Linux SL, version 4.13.0.0 Problems with persistence/config started when I had other problems to go online, I deleted the config file and the persistent files, but the system will not re-create them. I have tried to remove/re-install the "PersistenceManager"-module, create the folder-structure myself. And also reinstall the linux-runtime but its clearly not working. Any help appreciated.
Last updated: 2024-10-31

Post by ruben on DataSource not working CODESYS Forge talk (Post)
I had the same error. It took me a LONG way to figure it out, but in my case the problem was that I used LDATE_AND_TIME. It seems to be not supported, at least not in the Codesys version I used (3.5.16)
Last updated: 2024-02-01

Post by tomas111 on OPC UA Client API CODESYS Forge talk (Post)
I ran into a problem. Uploaded an example (https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html) After launch. on the emulator. I see that I am having problems: - UaExpert does not connect. There are many servers but no connection. - I can’t transfer the certificate from quarantine to trusted ones. There is some problem with creating the certificate. CS 19.2. If anyone has had similar problems, please give me advice. Thank you.
Last updated: 2024-05-20

Post by lsislsis on Alarms Placeholder CODESYS Forge talk (Post)
Hello. Is there any way to set placeholder for Alarms Storage at Usb Flash Disk? Regards
Last updated: 2024-10-03

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
Hi, We have a machine running Codesys on a Windows IPC (CODESYS Control Win v3 - x64). When we hard shutdown the machine, the code on the PLC sometimes becomes "corrupted" after a power on (When trying to login to the PLC, we get the message "The application 'Application' does not exist on device."). I've noticed these errors in the logs, but I'm not sure what to make of them. We are not using any RETAIN variables in our code, although I'm not sure about referenced librairies. (we are using the persistence manager). I'm pretty sure that not doing a graceful shutdown is the root cause of this. This being said, what is the proper way of doing a graceful shutdown? Is putting the Codesys application in "stop" sufficient? I know how to implement this, so if it works then it would be a quick fix. However, I think we need to add a UPS, which would detect power loss and inform the PLC that it needs to initiate its shutdown, and then the PLC would shutdown gracefully. Any help with this will be greatly appreciated :)
Last updated: 2024-10-03

Post by amy123 on codesys mqtt publish serialization CODESYS Forge talk (Post)
Hello, I am using the CODESYS IIoT Libraries SL MQTT Publish. Does this publish block only support publishing STRINGS as a readable format? I can publish ENUM, STRUCT, BOOL; however, MQTT Explorer will only display strings. When I use Wireshark, I can see that it is publishing something, but it looks to be publishing a serialized version which is a bunch of 0s or random text. If so, is there any way to deserialize this information back into a readable format? See pictures, where I have a BOOL TRUE that gets published as 001. Then see where I publish a STRUCT and it's an incomprehensible combination of 0s - only the string variable is displayed. Or, is it expected that you convert everything to a string before publishing? Any help is greatly appreciated! :)
Last updated: 2024-02-16

Post by david24 on Map in Codesys CODESYS Forge talk (Post)
Hello everyone, I have the task of programming a map. With the help of the visualization element "Table", I have managed to accomplish this. In the Input Configuration, I activated the option: "Write Variables", so that the user can change the values in the map. To test the program, I select the Online Mode (Simulation).There I change the values in the map. When restarting the program in CODESYS, the changes in the map are no longer there. Does anyone know an approach how to save the changes in the map? Thank you for your support Best regards David
Last updated: 2024-04-02

Post by bjarne-pagaard on OPC UA Server Status on Win RTE CODESYS Forge talk (Post)
Hi there, An "OPC Expert" client software is connecting to a Codesys Control RTE (x64) OPC UA Server. It reads only about 25 variables every 5 minutes. The OPC UA Server seems to shut down on the Codesys runtime. Is there any way to get information about the Codesys OPC UA Server status? Restart it? There is nothing in the PLC Logs after the OPC UA Server has started. It works for a while, then it doesn't. Any ideas? Any way of getting more info out of the Codesys OPC UA Server? -Bjarne
Last updated: 2024-10-21

Post by dandyk on Dynamic Images CODESYS Forge talk (Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06

Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
I succeed to change the device to PI_SL but still the same problem of the I2C device switching between running and not running. the only difference with your project is that yo use I2C_master device version 4.7.0 and i 4.7.13, for GPIO i also use the 4.7.13 version and you the 4.7.0. Can you send me the older version of the Raspberry PI pheripals library, because i cannot choose lower version then 4.7.10 for the GPIO and I2C_master device
Last updated: 7 days ago

Post by matt-s on HMI Pushbutton/Move Instruction CODESYS Forge talk (Post)
I know, that is not the issue though. The issue is the HMI_Blower_Auto_PB variable not changing to false. I do not have the IO modules plugged in yet, that is why there are NaN values for those variables. That should not affect this.
Last updated: 2024-01-25

Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
Good day, I’m writing this message out of frustration regarding the current way project files are saved as encrypted XML and single-file format in CODESYS. I find this approach to be quite tedious for several reasons: Limited Access to Structured Text: Not being able to access Structured Text (ST) externally makes it impossible to work with alternative editors like VSCode. Tools like VSCode are incredibly responsive and feature advanced systems such as GitHub Copilot, which would be a real game-changer when working with ST IEC. While CODESYS works well for small code snippets or debugging, when the codebase grows, switching to VSCode to boost productivity becomes essential, and copy-pasting between environments is a cumbersome workaround. Poor Integration with Git: This file format also makes it very difficult to integrate effectively with Git. I have tested the internal demo, but for advanced merges, it is unusable. Without properly formatted plain text, it’s impossible to leverage the vast ecosystem of external tools around Git that allow smooth merges in heterogeneous teams. File Corruption on Network Drives: I often work from multiple locations with shared network drives. When the development environment saves a file and something goes wrong midway (which can occasionally happen when using VPNs and network drives), the entire project becomes irrecoverable. There’s no way to cancel the save process, and the development environment freezes. This has happened to me at least four times over the past two weeks, and one of those incidents cost me an entire day of work. All of this is particularly disappointing because I truly believe that the libraries, runtime, and overall work done by CODESYS are exceptional. I find it fantastic that there is a platform allowing development of PLCs and control systems using OOP, which is a huge advantage in modern control engineering. I apologize for the rant, but this issue has been extremely frustrating. Best regards.
Last updated: 2024-10-15

Post by bahrt on Raspberry Pi GPIO mapping CODESYS Forge talk (Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IO’s become available with the corresponding mapped IO’s – the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are not active (at a fixed zero state) in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-21

Post by sachem on Problem retain values Weidmuller UC20-WL2000 CODESYS Forge talk (Post)
Good afternoon. I am working with a weidmuller uc20-wl2000 controller, using a codesys license. We made a ladder code to control a process, and it works well, but we want some variables to remain stored even when the controller is turned off. We tried to use retain variables, but at the time of loading the program, when we went offline from the controller, the program was deleted, it did not remain in the controller, and in the same way if we turned off the controller. In addition to this, when we tried to program it again, the program would not stay loaded and began to present errors with the opc-ua communication. What could be causing this problem? How can we maintain the values of the variables without damaging the program or affecting the controller? thank you
Last updated: 2024-04-10

<< < 1 .. 55 56 57 58 59 .. 234 > >> (Page 57 of 234)

Showing results of 5850

Sort by relevance or date