Post by ara32 on CODESYS 4 Linux:
CODESYS Forge
talk
(Post)
Hello! I managed to correctly launch CODESYS Developer Studio 3.5.17, almost all functionality works. The only issue remaining is that when connecting to a device and obtaining its public key, the NCryptEncrypt function is called, which is not fully implemented in the DLL source code, resulting in the connection not being established. Currently, the code of this function in the Wine repository looks like this: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG || flags & NCRYPT_PAD_OAEP_FLAG) { FIXME("No padding and oaep padding not supported\n"); return NTE_NOT_SUPPORTED; } if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } The program crashes due to the NCRYPT_PAD_OAEP_FLAG flag. I'm not proficient in C++, but I attempted to add handling myself, and here's the result: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG) { FIXME("No padding not supported\n"); return NTE_NOT_SUPPORTED; } BCRYPT_OAEP_PADDING_INFO oaepInfo = { 0 }; oaepInfo.pszAlgId = BCRYPT_SHA1_ALGORITHM; NTSTATUS status = BCryptEncrypt(key_object->key.bcrypt_key, input, insize, &oaepInfo, NULL, 0, output, outsize, result, flags); if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } Now, when calling the connection, it crashes with the error "bcrypt:BCryptEncrypt flags 0x4 not implemented." Can anyone help with enhancing this functionality or at least point me in the right direction?
Last updated: 2024-03-22
Post by greenwood on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline
CODESYS Forge
talk
(Post)
Hallo, ich versuche, eine Modbus-RTU-Kommunikation zwischen meinem Raspberry Pi mit CODESYS Control für Raspberry Pi 64 SL und einem Servotreiber von StepperOnline, Typ T6, herzustellen. Die Verbindung ist wie folgt: RJ45-Stecker am Servotreiber -> Kabel mit RJ45 an einem Ende und USB-A-Stecker am anderen Ende -> Seriell-zu-USB-Konverter -> Raspberry Pi. Der Seriell-zu-USB-Konverter und die Kabel habe ich zusammen mit dem Motor und Treiber von StepperOnline gekauft und sie sind dafür gedacht, den Servotreiber mit einem Computer zu verbinden, auf dem deren Setup-Software läuft. dmesg | grep tty auf dem Pi sagt mir, dass der USB-zu-Seriell-Konverter auf ttyusb0 ist. Ich weiß nicht, wie man das in einen COM-Port übersetzt, ich habe COM 1 genommen. Ich habe ein Projekt in Codesys erstellt und ein Modbus_COM-Gerät hinzugefügt, einen Modbus_Master_COM_Port und einen Modbus_Slave_COM_Port angehängt. Auf der Registerkarte "Allgemein" des Modbus_COM habe ich die folgenden Werte eingestellt: Slave address 1 Baud rate 9600 Parity None Data bits 8 Stop bits 2 Ich habe den Servotreiber auf die gleichen Werte eingestellt. (Ich habe auch andere Werte getestet, aber mit dem gleichen Ergebnis). Auf der Registerkarte "Modbus Slave Channel" des Modbus_Slave_COM_Port habe ich einen Kanal hinzugefügt und die folgenden Werte eingetragen: Access type Read Holding Registers (Function Code 3) Read Register offset 0x0000 Length 1 Ich habe noch keinen Code geschrieben, weil ich noch nicht herausgefunden habe, wie man die Kommunikation programmiert. Wenn ich das Projekt zum Raspberry Pi herunterlade scheint der Modbus_Master_COM_Port zu laufen (grünes Symbol), aber der Modbus_Slave_COM_Port nicht (rotes Dreiecksymbol). Wenn ich einen anderen COM-Port eintrage, haben sowohl der Master als auch der Slave das rote Dreiecksymbol. Ich habe dies auch mit meinem Windows-PC unter Verwendung von Codesys Control Win 64 versucht und die gleichen Ergebnisse bekommen. Ich wäre dankbar für jede Hilfe oder Tipps, wie ich den Grund dafür herausfinden kann, warum der Servotreiberreiber nicht reagiert.
Last updated: 2024-05-31
Post by george32 on CSV file and string manipulation.
CODESYS Forge
talk
(Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27
Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by garyl on Comments in arrays and assigning RST coil's to 600 outputs
CODESYS Forge
talk
(Post)
Hello all, im working on a project that requires me to convert an old automation direct DirectSoft PLC d2-250-1. One of the problems im encountering is that all of the comments are attached to members of the different addresses. When i convert the addresses (1777 "C" registers, 777 X registers, and 20,0000 V registers) im running into difficulties keeping the inputs/outputs correct since they are missing documentation. Is there a good way to retain the comments of the indexes in the array? Secondly, initially i was declaring the "C" and "V" addresses individually and this worked to retain the comments as to which register did what, however i ran into a problem when one rung reset (or set to 0) approximately 600 C Addresses. Since each tag is separately declared this proved to be nearly impossible without a literal wall of code that attempted to crash the program. So i converted all of the registers (C,X,Y,V) into separate structs, declared them as arrays and pointed all of the original call outs in the program to the newly defined structs. However i have now lost comments and the program is very hard to follow. Thanks for any help with this issue.
Last updated: 2023-08-31
Post by arundara on Variable Sync Issue In Soft Plc Redundancy
CODESYS Forge
talk
(Post)
Hello, I was trying to create a redundancy POC for our application where we read data from few modbus tcp devices. As there is a limitaion that modbus tcp device support only for single master device, we wanted to test how the variable sync happens in redundancy mode. For that i have used the redundancy sample code added a variable "b" under a condition. What i observed was while active controller is running, if passive controller is powerup, passive controller is able to sync all the data configured for redundacny. But after that the variable data which resided under a condition is not synching from active to passive controller. I have attached the image where i have highlighter the variable. Can some help me to understand how redundacny work in codesys soft plc and if there is a solution to sync variable which are under condition, please explain the same or suggestion to achieve the same. Hardware - Raspberry Pi (2 qty) Redundancy licence used - yes in both controllers. Codesys runtime - 4.9.0.0 Codesys software version - V3.5 SP19 if i have posted this question in wrong section, please do let me know in whcih section i have to post this question.
Last updated: 2023-12-01
Post by ph0010421 on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08
Post by nz-dave on Bool turning on in case stament in wrong state?
CODESYS Forge
talk
(Post)
I had the FB called via a for loop to call a few instances of my FB I have removed it the for loop and just called them 1 by 1. Seems to have sorted the problem. tho, i have other FB's and for loops doing the same thing but they are all fine. below is basically what was happening. var: mVibrator : ARRAY[1..GVL_Settings.Number_Of_Products] OF Main_Vibrator; end_var Controller(PRG) call: FOR v := 1 TO GVL_Settings.Number_Of_Products BY 1 DO; mVibrator[v] (); END_FOR So at state 30: the mVibrator[1].start was turning on 30: Main_Mixer.Start := TRUE; Process_State := 2; IF Main_mixer.Done THEN Main_Mixer.Start := FALSE; Control_State := 40; END_IF but its not till state 50: that it is actual in the code. 50: Main_Suction_valve.Open_Input := TRUE; mVibrator[1].Start := TRUE; Process_State := 4; IF GVL_Weigh_hopper.LoadCell_Weight = 0 THEN Main_Suction_valve.Open_Input := FALSE; mVibrator1.Start := FALSE; Control_State := 60; END_IF Thanks for your input.
Last updated: 2023-12-16
Post by vahasa on CAN TPDO / RPDO
CODESYS Forge
talk
(Post)
Hi I'm automation engineering student and I'm not yet quite familiar with CAN-bus. What I am trying to achieve, to send two byte message via CAN from Epec display to Scott Drive inverter. I'm using code template made with Epec Multitool in Codesys 3.5 Problem i'm facing is that drive responds with same COB-ID. In multitool, you can create TPDO/RPDO. And depending on that, display either sends or only receives. This is problem, because for parameter polling from drive, you need to send two byte request to 0x399 and drive responds with eight bytes. If request is longer, drive don't respond. 0x399 is currently setted as RPDO, so display doesn't send anything on startup and I made program that sends messages to 0x399 bytes 0 and 1 and bytes 3-7 are shown in display. If setted as TPDO, display send all eight bytes and therefor drive cannot respond. But, I think because they are defined as RPDO, display won't send message, although monitoring with Codesys, values are changed. Question is, how should COB-ID be configured in Codesys, so it wouldn't automatically start to send message but would send when needed?
Last updated: 2023-12-19
Post by levih on DocScripting
CODESYS Forge
talk
(Post)
Hello I'm trying to use the DocScripting collection in Codesys. I've made it work on one PC(1) for the 3.5.16.4 version of the script collection. But when I try the same setup on another PC(2), I get an error message: Error loading Python DLL: D:\SCRIPTING\3.5.16.40\python27.dll (error code 14001) My setup on both PC's is thus: 1. Downloaded and installed Python 2. Copied the folder with the scripting collection to C: (because of admin rights) 3. Placed my .library file in the same folder as the scripting collection Only difference is that Python is v3.12.0 on PC1 and v3.12.1 on PC2. I thought maybe it was something with Python, but then I have tried using the scripting collection from 3.5.16.1, and that seems to work. Just not for scripting collection 3.5.16.4. I also can't seem to find any scripting collections on newer versions of Codesys? (e.g. 3.5.19.10) Thanks in advance!
Last updated: 2024-01-22
Post by axilleas on SMC_Interpolator + SMC_controAxislbyPos
CODESYS Forge
talk
(Post)
dear all I am working on a very generic gantry system (virtual drives + win v3 control) reading gcode from external file. In order to stop the interpolator function from running when gaps are detected, SMC_controlAxisByPos FB has the bStopIpo output which according to the manual is connected to the Interpolator's bEmergencyStop. Lets assume that the axis are parked in position X1000 Y1000 and the initial G code movement is G00 X500 Y500. The normal behavior is to travel from the actual x1000 y1000 to G00 X500 Y500. The SMC_Interpolator always gets the X0 Y0 as the initial position, meaning that the bStopIpo is active until the axis are in X0 Y0 and the release the interpolator to set the new positions to X500 Y500. Is there a suggested method to solve this behavior? bonus question: I get a lot of bStopIpo during standard interpolation movements (not gaps). While working with virtual axis this is not a problem but when real axis are installed this will be an issue. What exactly triggers the bStopIpo output? Slow axis accelerations compare to Gcode defaults? Kind Regards
Last updated: 2024-02-05
Post by fredsta on Unable to load dynamic modules (Download failed: Application=Application)
CODESYS Forge
talk
(Post)
Hey there, I am currently trying to find a good solution for the communication between CODESYS Control on Raspberry Pi and "the rest of the world", i. e. the things apart from CODESYS on my linux. My first approach was to use the c-integration. So I created a lib, defined extern fbs, compiled the code on my Pi using the SDK and put the .so into my lib project. When I try to log into the Pi and load the program, I get the error message which you can see in the attached picture. "Die dynamischen Module der C-Integration konnten nicht auf das Laufzeitsystem geladen werden" is german and means roughly "the modules from the c-integration could not be loaded onto the runtime system." Is this normal? Am I doing something wrong? I will have a look at the unix domain socket thing next, as I am still in the process of finding the best solution for the communication.
Last updated: 2024-02-15
Post by timl on BacNet "Unaufgelöste Referenz"
CODESYS Forge
talk
(Post)
Hallo, ich habe Probleme beim nachbauen des BacNet2 Tutorials "Erste Schritte" aus der CODESYS Online Help. https://content.helpme-codesys.com/de/CODESYS%20BACnet/_bacnet_first_steps.html Das Anlegen des BacNet2 Servers und der danach folgenden BacNet Datenpunkte erfolgt ohne Probleme. Der Code lässt sich mit F11 auch Fehlerfrei generieren. Beim Download auf die SPS tritt dann der Fehler auf dem Bild auf. Anbei auch ein Bild des Logs nach dem Download. CODESYS BACnet 2.0.0.0 ist über den Installer runtergeladen. Device: CODESYS Control Win V3 x64 Version 3.5.19.40 CODESYS 3.5.19.40 Im Bibliotheksverwalter ist BACnet2 2.0.0.0 aufgeführt Die Konfigurationsdatei habe ich mit folgenden anpassungen abgespeichert: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows ;Component.8=CmpHilscherCIFX ;Component.9=CmpPCANBasicDrv ;Component.10=CmpCANFoxDrv ;Component.11=CmpIxxatCANDrv ;Component.12=CmpBlkDrvCanServer ;Component.13=CmpBACnet Component.14=CmpBACnet2 [CmpBACnet2] ;configuration file of the BACnet stack IniFile=$PlcLogic$/bacstac2.ini ;task priority of the BACstack process task, default: TASKPRIO_NORMAL_END (159) TaskPrio=128 ;name of the named pipe for the communication with the BACstack AppName=/tmp/BACnetServer Habe ich etwas vergessen?
Last updated: 2024-02-16
Post by alex00 on DCS / Central Engineering with Codesys support
CODESYS Forge
talk
(Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19
Post by alex00 on DCS / Central Engineering for Codesys
CODESYS Forge
talk
(Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19
Post by francescoc on Custom log CmpLog
CODESYS Forge
talk
(Post)
Hi, I am trying to create a log in my application. Since I cannot find any documentation regarding modifying the codesys configuration file to be able to log in ms, i tried to create a new log via CmpLog.LogCreate. Below is the part of the code where I create the logger and write a test string. In the log tab of codesys I actually see the new log that was created, but it is empty, and in the folder I cannot find any files. I can't find any detailed documentation. Can you guys give me support? Are there any examples? Thank you IF NOT FirstCycle THEN LogName:= 'LOGS/TestLog'; LogOptions.bEnable:= 1; LogOptions.iMaxEntries:= 5000; LogOptions.iMaxFiles:= 100; LogOptions.iMaxFileSize:= 5000; LogOptions.szName:= LogName; LogOptions.uiType:= CmpLog.LogTypes.LT_TIMESTAMP_RTC_HIGHRES; LogOptions.uiFilter:= CmpLog.LogClass.LOG_ALL; LogHandle:= CmpLog.LogCreate(pOptions := ADR(LogOptions), pResult:= ADR(Result)); LogHandle:= CmpLog.LogOpen(pszName:= LogName, pResult:= Result); Component_Manager.CMAddComponent2('TestLogNEW', 16#00000001, ADR(udiCmpIdNEW), 0); CmpLog.LogAdd2(LogHandle, udiCmpIdNEW, CmpLog.LogClass.LOG_INFO, 1, 1, 'Logger started...'); END_IF IF TestWrite THEN TestWrite:= FALSE; CmpLog.LogAdd2(LogHandle, udiCmpIdNEW, CmpLog.LogClass.LOG_INFO, 1, 1, 'Write test'); END_IF
Last updated: 2024-03-16
Post by alexgooi on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi Duvan, You could make this in 1 single object (FB), Indeed don't use a function for this beacuse you need some memory to keep the old value. For i := 0 TO 200 BY 1 DO //Check if the value has been changed IF Old_Value[i] <> Value[i] THEN //Set the trigger to TRUE Trigger[i] := TRUE; Old_Value[i] := Value[i]; END_IF END_FOR If you define the Value array as an In_Out and the Trigger as an In_Out you arn't claiming any aditional memory to your system. You ofcourse then need to add some code arround it that does something with the trigger and writes it back to FALSE again. If you want more flexability you also could use pointers instead of using the IN_OUT FOR i := 0 TO 200 BY 1 DO address := address_Input + i * SIZEOF(*Put type here); IF Address^ <> Old_Value[i] THEN Trigger[i] := TRUE; Old_Value[i] := Address^; END_IF END_FOR
Last updated: 2024-04-02
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors
CODESYS Forge
talk
(Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02
Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06
Post by hanoues on setting date and time on CPX-E
CODESYS Forge
talk
(Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21
Post by tortilla on J1939 connection between two devices
CODESYS Forge
talk
(Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23
Post by wollvieh on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
Here a code for an Operation Counter with : days,hours,minutes,seconds as an example, maybe it points you the right direction ? FUNCTION_BLOCK OperationDayHour VAR_INPUT IN : BOOL; // Betrieb Takt : BOOL; // 1Hz Systemtakt END_VAR VAR_OUTPUT BetrTag : UDINT; // Ausgabe Betriebstage Betrstd : UDINT; // Ausgabe Betriebsstunden Betrmin : UDINT; // Ausgabe Betriebsminuten Betrsec : UDINT; // Ausgabe Betriebsekunden BetrString : STRING; // Ausgabe als String END_VAR VAR ///Erkennung Taktflanke Flanke: R_TRIG; END_VAR VAR_IN_OUT BetrsecAbsolut: UDINT; //Ein/Ausgangsvariable Betriebssekunden RETAIN !!! END_VAR Flanke(CLK:= Takt, Q=> ); (*Erkennung Taktflanke*) IF (IN AND Flanke.Q) THEN (*Sekunden hochzählen*) BetrsecAbsolut := BetrsecAbsolut + 1; END_IF Betrsec := BetrsecAbsolut MOD 60; Betrmin := ( BetrsecAbsolut / 60) MOD 60; Betrstd := ( BetrsecAbsolut / 60 / 60 ) MOD 24; BetrTag := ( BetrsecAbsolut / 60 / 60 /24 ); BetrString := RIGHT ( UDINT_TO_STRING( BetrTag + 100000),5); BetrString := CONCAT (BetrString, 'd_'); BetrString := CONCAT (BetrString,RIGHT ( UDINT_TO_STRING( Betrstd + 100000),5)); BetrString := CONCAT (BetrString, 'h_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrmin + 100),2)); BetrString := CONCAT (BetrString, 'm_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrsec + 100),2)); BetrString := CONCAT (BetrString, 's');
Last updated: 2024-05-27