Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys. CODESYS Forge talk (Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18

Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22

Post by garyl on Comments in arrays and assigning RST coil's to 600 outputs CODESYS Forge talk (Post)
Hello all, im working on a project that requires me to convert an old automation direct DirectSoft PLC d2-250-1. One of the problems im encountering is that all of the comments are attached to members of the different addresses. When i convert the addresses (1777 "C" registers, 777 X registers, and 20,0000 V registers) im running into difficulties keeping the inputs/outputs correct since they are missing documentation. Is there a good way to retain the comments of the indexes in the array? Secondly, initially i was declaring the "C" and "V" addresses individually and this worked to retain the comments as to which register did what, however i ran into a problem when one rung reset (or set to 0) approximately 600 C Addresses. Since each tag is separately declared this proved to be nearly impossible without a literal wall of code that attempted to crash the program. So i converted all of the registers (C,X,Y,V) into separate structs, declared them as arrays and pointed all of the original call outs in the program to the newly defined structs. However i have now lost comments and the program is very hard to follow. Thanks for any help with this issue.
Last updated: 2023-08-31

Post by arundara on Variable Sync Issue In Soft Plc Redundancy CODESYS Forge talk (Post)
Hello, I was trying to create a redundancy POC for our application where we read data from few modbus tcp devices. As there is a limitaion that modbus tcp device support only for single master device, we wanted to test how the variable sync happens in redundancy mode. For that i have used the redundancy sample code added a variable "b" under a condition. What i observed was while active controller is running, if passive controller is powerup, passive controller is able to sync all the data configured for redundacny. But after that the variable data which resided under a condition is not synching from active to passive controller. I have attached the image where i have highlighter the variable. Can some help me to understand how redundacny work in codesys soft plc and if there is a solution to sync variable which are under condition, please explain the same or suggestion to achieve the same. Hardware - Raspberry Pi (2 qty) Redundancy licence used - yes in both controllers. Codesys runtime - 4.9.0.0 Codesys software version - V3.5 SP19 if i have posted this question in wrong section, please do let me know in whcih section i have to post this question.
Last updated: 2023-12-01

Post by marek71 on Ambiguous use of name - CO136 CODESYS Forge talk (Post)
My PLC is WAGO PFC200 Firmware Revision 26. target After updating WAGO_Devices_and_Libraries with newer Firmware 27, CODESYS wants to update all libraries to new versions. I will only add that I did not update the Firmware in the PLC. After compiling the program, I received the following errors: ------ Build started: Application: Device.Application ------- Typify code... [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_RESULT' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0032: Cannot convert type 'Unknown type: 'RTS_INVALID_HANDLE'' to type 'POINTER TO BYTE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0136: Ambiguous use of name 'RTS_INVALID_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0046: Identifier 'RTS_INVALID_HANDLE' not defined [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_tx_empty: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_get_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_line_available: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): COMSW_SET_MODE: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_set_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' Compile complete -- 10 errors, 0 warnings Build complete -- 10 errors, 0 warnings : No download possible The problem was caused by the WagoSysPlainMem(WAGO) library in the original version 1.5.3.0 after updating to 1.5.3.1. After returning to version 1.5.3.0, the problems disappeared. Probably the version number of this library is responsible for supporting the appropriate Firmware Revision. Can anyone confirm or deny my suspicions?
Last updated: 2024-07-06

Post by ahuckphin on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
I have a DFRobot RS485 temperature & humidity sensor (SEN0438) connected to my Raspberry Pi via a USB to RS485 adapter. I am able to connect and read the sensor data when running a python code locally. However in Codesys, I encounter this error "A bus error has occurred." and "There was no response in time". Could this be because of Modbus Server Channel and Modbus Server Init configuration on my part? Admittedly I am new to Codesys. To get to this stage, I: 1. added some lines to CODESYSControl_User.cfg 2. added "Modbus_COM" in Codesys and set "Serial Port Configuration" under "General" 3. added "Modbus_Master_COM_Port" in Codesys and checked transmission mode is set to "RTU" 4. added "Modbus_Slave_COM_Port" in Codesys and checked server address is set to 1 (also set 1 in my sensor) 5. added 1 channel and 1 init for "Modbus_Slave_COM_Port" under "Modbus Server Channel" and "Modbus Server Init"
Last updated: 2024-07-10

Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs CODESYS Forge talk (Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11

Post by berto on Opening PDF in Web Browser in Target Visu HMI CODESYS Forge talk (Post)
Hi everybody, I've been facing problems with the PDF visualization in Web Browser. I am trying to open a pdf file called 'sample.pdf' which I manually saved inside PlcLogic/visu folder. I am setting the web browser URL as: 'http://127.0.0.1:8080/sample.pdf' but I get 'refused connection'. I got a similar error trying to open https sites and I discovered that I can only open http websites. Opening 'http://de.wikipedia.org' everything works fine. I also tried to check using code whether the sample.pdf is present in the directory. Unfortunately, when I try to read directories of 'PlcLogic' I get file FILE_OPERATION_DENIED (I am using File.DirList). I would like to be able to open PDF files in web browser. Possibly to move new PDF files in the folder as my customer wants to display different pdf manuals on the hmi. Here you find some screenshots and my .project. I am using Codesys 3.5.19.70. Best regards, Berto
Last updated: 2024-07-11

Post by otbeka on CmpCrypto CryptoGenerateHash Not Outputting CODESYS Forge talk (Post)
Hi, I have been trying to use CryptoGenerateHash from the CmpCrypto Implementation library. My code is taken almost directly from the CryptoDemo.project example provided on Codesys Forge, yet the CryptoGenerateHash function does not write to the address listed in pHash. RTS_IEC_RESULT is OK, but I am getting nothing out of the function. No errors either, all my libraries are up to date. Any help would be appreicated! PROGRAM PLC_PRG VAR sMessage : MESSAGE := 'The red fox runs across the ice'; abyHashCode : HASH_CODE := [ 16#52, 16#ED, 16#87, 16#9E, 16#70, 16#F7, 16#1D, 16#92, 16#6E, 16#B6, 16#95, 16#70, 16#08, 16#E0, 16#3C, 16#E4, 16#CA, 16#69, 16#45, 16#D3 ]; xMessageOK : BOOL; END_VAR xMessageOK := CheckMessage(sMessage, abyHashCode); FUNCTION CheckMessage : BOOL VAR_INPUT sMessage : REFERENCE TO MESSAGE; abyHashCode : REFERENCE TO HASH_CODE; END_VAR VAR _hHASH : RTS_IEC_HANDLE := CryptoGetAlgorithmById(ui32CryptoID:=RtsCryptoID.HASH_SHA1, pResult:=0); Result : RTS_IEC_RESULT; bsMessage : RtsByteString := (ui32MaxLen:=SIZEOF(sMessage), pByData:=ADR(sMessage), ui32Len:=TO_UDINT(LEN(sMessage))); abyNewHashCode : HASH_CODE; bsNewHashCode : RtsByteString := (ui32MaxLen:=SIZEOF(abyNewHashCode), pByData:=ADR(abyNewHashCode)); diCmpResult : DINT; END_VAR Result := CryptoGenerateHash(hAlgo:=_hHASH, pData:=ADR(bsMessage), pHash:=ADR(bsNewHashCode)); diCmpResult := SysMemCmp(pBuffer1:=ADR(abyHashCode), pBuffer2:=ADR(abyNewHashCode), udiCount:=SIZEOF(HASH_CODE)); CheckMessage := diCmpResult = 0;
Last updated: 2024-09-06

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by struccc on Bibliothek: floatingpointutils CODESYS Forge talk (Post)
The issue s the byte order typically in this case. Can be especially problematic with floating point numbers - even more tricky if transferred with a word based protocol. It is a peasant way to try out the alternatives, dword order can be a-b-c-d, b-a-d-c, c-d-a-b, d-c-b-a where a is the most significant, d is the least significant byte. So all you need is to swap the bytes in your dword, until you get the expected result. If you don't want to mess writing code for this, I'd recommend CAA_Memory library for that: MEM.ReverseBYTEsInDWORD and MEM.ReverseWORDsInDWORD functions would definitively do the trick. Otherwise, can do like this: VAR dwIn : DWORD := 16#11223344; dwOut : DWORD; rOut : REAL; pIN : POINTER TO BYTE; pOUT : POINTER TO BYTE; END_VAR pIN := ADR(dwIn); //pOUt := ADR(dwOut); pOUt := ADR(rOut); pOut[0] := pIN[3]; pOut[1] := pIN[2]; pOut[2] := pIN[1]; pOut[3] := pIN[0]; Ugly, but does the job...
Last updated: 2024-11-19

Post by etienneneu on loading delay with the option "check client animations and overlay of native elements" CODESYS Forge talk (Post)
Hey NicolaG_89, thanks for the tip. But I have seen in the developer tools of the Webclient that a multiple fetching of the image and script data occurs when changing frames (HTTP code 304 NOT Modified), although these are already in the clients cache, which leads to unnecessary loading of resources from the web server. This behavior can also be found if the option “Support client animations and overlay of native elements” is deactivated, but this does not lead to such long delays. I had already tested loading all Visu elements so that everything was fetched once before they could be used. But that didn't help either. To prevent this behavior (permanent fetching), I have used a different way of switching the Visu elements in the VisuDemo Project, which also uses HTML5 control elements. I implemented this with the visibility of entire Visu elements. As a result, it only has to be fetched once and does not have to be fetched again when reloading. But I am still unsure about this implementation if the scope of the visualization becomes larger, as the Codesys visualization documentation advises against using many invisible elements. Best regards Etienne
Last updated: 2024-11-19

Post by sean-barton on Ambiguous namespace in library dependencies CODESYS Forge talk (Post)
I am trying to install the MQTT Client SL in an existing project I have been working on for years. After adding the library to the project, and without adding any other code, upon building I get a C0180: Ambiguous namespace 'MBM' error between the memory block manager (MBM) in the NetBaseSrv dependency of the MQTT Client SL library and the memory block manager (MBM) in the CAA CanL2 dependency of the 3S CANopen stack library. I have tried: * setting "Only allow qualified access to all identifiers." in the properties for both the parent libraries. * deleting the 3S CANopen stack library. Upon (re)building the error simply points to another conflicting library - there are many. * deleting the Library Manager and rebuilding it. * adding the memory block manager library (used in the NetBaseSrv) manually and changing its namespace to MBM3S. None of the above allow me to access the MQTT library through its namespace (MQTT). Adding the memory block manager manually removes the C0180 error, but the MQTT library is not accessible - i.e. mqttClient : MQTT.MQTTClient; highlights the mqttClient as "Identifier 'MQTT.MQTTClient' not defined". Is there anything else I can try?
Last updated: 2025-01-09

Post by fabiodasilveira on PLC Shell commands via ST Code CODESYS Forge talk (Post)
Hello Everybody, I have created a project for an Eaton XC303 that sends lots of data to a router via UDP. It works fine. However, when there is more than one product connected to the router, then it is necessary to change the IP address of the Ethernet port 0, from e.g. 192.168.2.11 to 192.168.2.12 (second product). It is easily done via PLC Shell (setipaddr 0 192.168.2.12), but the people in production is struggling with the PLC Shell commands and I would like to create a Visualization page that will hide that. I used the instruction: eChangeIPResult:= SysSockSetIPAddress(strEthernetPort, strIPAddress); and it works, until the PLC resets. I already read some posts and it appears that I need to stop the Ethernet 0 port and Reconfigure it, but I am really struggling to find the right way to do it. Any help will be much appreciated.
Last updated: 2025-02-28

Post by pernockham on Engineering IDE from linux? CODESYS Forge talk (Post)
I have done the switch (linux mint, virtual windows through QEMU/KVM) now and is generally pleased. Have had problems in two areas initially. To bridge IP to the Virtual unit (solved), I overthought things initially. Solution. Configure manually a bridge in the mint-"network connections". Use that bridge in the Qemu settings as "Bridge device", "Device name": "name of the configured bridge" Figure out where to store the projects. I started out have the data in linux world (sort of) and linking it the windows with "virtio-fs". That had some serious impact though on git-handling. It seems that virtio-fs interpreted any file-path as lowercase only even if there were uppercase, resulting in git not able to sync files between its repository and the source code (it created a new file-path for me with only lowercase). Then I switch to samba-share instead and this works much better, though (git-actions) is a part that still has low performance with lots of waiting for file-actions. What should be the best way of handling the source/git? Edit to answer myself: Save the project "locally" in windows, then a lot of slow performance is avoided. Then a git-remote sync for backup.
Last updated: 2025-05-08

Post by kuegerls on Programmatically clearing or syncing Data Source Manager cache? CODESYS Forge talk (Post)
Hi everyone, is there a way to programmatically clear the cache of the Data Source Manager in CODESYS so that variable values are re-synchronized from the OPC UA server (Symbol Configuration with OPCUA features)? Alternatively, is it possible to trigger a manual synchronization of data source variables from within the application code at runtime? Here’s the situation: A variable is first written by the OPC UA client to the server in one state of a state machine and changes to another state – so the initial communication works. Later, the server changes the variable value, but the client does not receive or reflect the updated value, unless the variable is actively written again. I’m looking for a way to force the client (data source manager) to re-read or refresh the variable state from the server, possibly by clearing the internal cache or triggering a sync. Any ideas or suggestions would be greatly appreciated! Thanks!
Last updated: 2025-05-23

Post by jakubmphoenix on EtherCAT Master on RaspberryPi with EtherCAT Slave on Beckhoff CODESYS Forge talk (Post)
Hello everyone, I’m currently working on setting up an EtherCAT Master using CODESYS on a Raspberry Pi, and I’ve run into some issues I could use help with. Project Setup: EtherCAT Master: Raspberry Pi with CODESYS Control for Raspberry Pi 64 SL installed EtherCAT Slave: Beckhoff CX5130 with EK1200 coupler I/O Module: EL2008 License Module: EL6070-0033 I’ve installed the required CODESYS packages and the Linux gateway on the Raspberry Pi. In my project, I added the EtherCAT Master with the appropriate port settings and scanned for devices. The CX5130 shows up as a slave, but communication fails—I'm getting error messages and can't access the outputs. Specifically: The EL2008 output module isn’t recognized properly in CODESYS. There’s no option to communicate with it through the CX5130. I’ve tried connecting via both the Raspberry Pi’s built-in Ethernet port and an external network card. I've attached screenshots showing the errors I get in CODESYS and the devices detected via TwinCAT for reference. Any help or suggestions would be greatly appreciated! Thanks in advance! EMERGENCY FROM DEVICE 1001 ERROR CODE 16#A000 Error register 16#02 Error field: 16#02 Error field : 16#0E 16#04 16#00 16#04 16#00
Last updated: 2025-07-16

Post by gmau on RS232 Communication in CODESYS Control RTE V3 CODESYS Forge talk (Post)
Hello, I would like to implement RS232 communication into CODESYS Control RTE V3. I was writing the program testing it on CODESYS Control Win V3, where it worked fine. When I changed it to RTE, the communication was on, but I cannot send the data between PLC and scale - there is no or little response from scale - mostly one time receive and that is it. On Win V3 it was working fine. I read that I am supposed to configure CODESYSControl file for a proper communication using RTE, but even after that I can not get a stable and working communication. I am attaching my CODESYSControl and CODESYSControlUser data below, as well as I am sending the code from communication function. The communication should be through COM1 port of PC. CODESYS Version: CODESYS V3.5 SP21 + (64-bit) Runtime + Version: CODESYS Control RTE V3 Version 3.5.21.0 / CODESYS Gateway V3 - x64 Version 2.5.21.0 I would be much gratefull for any help. Sincerely,
Last updated: 2025-07-16

Post by x97tommi on XMLWriteAsync erzeugt keine XML-Datei unter CODESYS Control Win V3, obwohl NO_ERROR gemeldet wird CODESYS Forge talk (Post)
Ich versuche, mit dem Funktionsbaustein XMLWriteAsync eine XML-Datei zu erstellen, aber die Datei wird nicht erzeugt, obwohl der Funktionsbaustein NO_ERROR meldet. Ich habe sowohl meinen eigenen Code als auch das CODESYS-Beispiel getestet, aber in beiden Fällen wird keine Datei geschrieben. Ich arbeite mit CODESYS Control Win V3 als SoftPLC unter Windows. Problem: • Der Funktionsbaustein XMLWriteAsync meldet NO_ERROR (keine Fehler in xError, eError, oder eLastError), aber die XML-Datei wird weder im angegebenen Pfad (C:\Users\tomgs\Documents\CodesysDataTest\xmltest.xml) noch im res/-Verzeichnis (wie im CODESYS-Beispiel verwendet) erstellt. • Das CODESYS-Beispiel mit res/xmltest.xml als Pfad funktioniert ebenfalls nicht. • Ich aktiviere xExecute manuell in der Online-Ansicht, und xDone wird TRUE, ohne dass xError ausgelöst wird. • Der Ordner C:\Users\tomgs\Documents\CodesysDataTest\ existiert, und ich habe Schreibrechte. • Ich habe auch alternative Pfade wie C:\Temp\xmltest.xml und res/xmltest.xml getestet, ohne Erfolg. Im Anhang das Beispiel von Codesys. Vielen Dank im Vorraus.
Last updated: 2025-07-16

Post by pouyavakili on Execute Codesys Tests with python CODESYS Forge talk (Post)
Thank you for your input! What I'm ultimately trying to achieve is automated test execution as part of a CI/CD pipeline (e.g. in GitLab or Azure DevOps). For this, I need to: Open a CODESYS project via script Build the project Run the Test Manager tests from a .TestRepository.xml Collect test results (e.g., pass/fail + a report) Exit with a proper return code (for pipeline success/failure) To integrate this into automation, I’m using the CODESYS scripting engine via Python (headless), but the issue is that the get_testmanager() function isn't available on the project object — even though Test Manager is installed, licensed, and works interactively in the IDE. Are you suggesting that I should: Use the Test Manager GUI to script the logic with its internal scripting language? Or is there a way to launch the Test Manager in headless/scripted mode, while still being able to control things via Python? If there's a supported way to automate tests with the Test Manager using scripting, especially from pipelines or headless environments, I’d really appreciate any pointers or example workflows. Thanks again!
Last updated: 2025-07-24

Post by antonz on CoDeSys v3.5: creating libraries for both 32-bit and 64-bit controllers CODESYS Forge talk (Post)
Looking for thoughts on creating libraries that can be used on both 32-bit and 64-bit controllers. We are currently writing software in CoDeSys for both target types and will continu to do so for the near future. Projects are always unique, no straight forward copy/paste, yet there is enough similarity between them to use libraries for recurring logic. I do not want to create and maintain twice for both platforms if this is not absolutely necessary. I am aware of useful datatypes like __XWORD, __XINT, __UXINT. Still looking for more information and/or sample code for portable pointer arithmetic. In addition to that: how should one go about when creating and working with compiled libraries? Would I need to compile the same lib twice, once for 32-bit targets once for 64-bit targets? I would end up with two different libs with the same namespace, which does not sound elegant to me. Note: I did not intentionally make the previous paragraph bold. The forge forum software seems to do this automatically upon insertion of a word which starts with two underscores, e.g. __XWORD (yeah, here we go again :) )
Last updated: 2025-08-25

Post by leandroct on Creating Boot Application not working CODESYS Forge talk (Post)
I have a Control Win V3.5 SP20 (64-bit) application, and until now, I open the program (with a password) and download it. However, I need to give the client the option to install the program on the Controller, without them having to open it and access the code. So, I followed these steps: 1 – In the Online => Create Boot Application menu, I saved the generated files in a directory: Application.app Application.crc PlcLogic\visu\ directory with several files 2 – In the SysTray, I ran the PLC, and it created a directory. In the root of this directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E84889DB), I pasted Application.app and Application.crc. Since it created a \visu directory, I pasted the PlcLogic\visu\ files generated in Create Boot Application into it. 3 - In the general Codesys directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64), I edited CodesysControl.cfg, adding: [CmpLog] Application.1=Application 4 - When running the PLC, nothing happens and the TargetVisu screen does not open. What I'm doing wrong?
Last updated: 2025-09-03

Post by hprog on Codesys 3.5.20/21 Import Geräterepository bzw. Bibliothen Repository funktioniert nicht CODESYS Forge talk (Post)
Hallo, Ich habe schon mehrfach Treiber für I2C Geräte geschrieben und keine Probleme mit dem Einbinden gehabt, aber derzeit komme ich auf keinen grünen Zweig. Der Import des Geräterepository (xml) funktioniert, der Import ins Bibliothekenrepository funktioniert auch, aber wenn ich dann das Gerät an den I2C MAster anfüge funktioniert der Import in das Projektbibiothek nicht und somit wird auch der entsprechende FB nicht instanziert und ich bekomme folgende Fehlermeldungen ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] I2C_Test_Examples: MCP23008_X81 [Device: I²C: I2C_master]: Bibliothek Raspberry I2C MCP23008_X81, 1.1.0.1 (3S - Smart Software Solutions GmbH) konnte nicht eingefügt werden: [FEHLER] I2C_Test_Examples: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'MCP23008_X81.AfterReadInputs' erwartet [FEHLER] I2C_Test_Examples: C0046: Bezeichner 'MCP23008_X81' nicht definiert [FEHLER] I2C_Test_Examples: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'MCP23008_X81.BeforeWriteOutputs' erwartet [FEHLER] I2C_Test_Examples: C0046: Bezeichner 'MCP23008_X81' nicht definiert Kompilierung abgeschlossen -- 5 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 5 Fehler, 0 Warnungen : Kein Download möglich Als Device habe ich Name: CODESYS Control for Raspberry Pi SL Hersteller: CODESYS Kategorien: SoftMotion Steuerungen Version: 4.13.0.0 Bestellnummer: 2302000009 Beschreibung: Eine Soft-SPS nach IEC 61131-3 für Raspberry Pi. CODESYS Control basiert auf CODESYS SDK 3.5.20.20, Release . Das ganze unabhängig von der Codesys Version
Last updated: 2025-10-06

Post by hprog on Codesys 3.5.21 Import Geräterepository bzw. Bibliothen Repository funktioniert nicht CODESYS Forge talk (Post)
Hallo, Ich habe schon mehrfach Treiber für I2C Geräte geschrieben und keine Probleme mit dem Einbinden gehabt, aber derzeit komme ich auf keinen grünen Zweig. Der Import des Geräterepository (xml) funktioniert, der Import ins Bibliothekenrepository funktioniert auch, aber wenn ich dann das Gerät an den I2C MAster anfüge funktioniert der Import in das Projektbibiothek nicht und somit wird auch der entsprechende FB nicht instanziert und ich bekomme folgende Fehlermeldungen ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] I2C_Test_Examples: MCP23008_X81 [Device: I²C: I2C_master]: Bibliothek Raspberry I2C MCP23008_X81, 1.1.0.1 (3S - Smart Software Solutions GmbH) konnte nicht eingefügt werden: [FEHLER] I2C_Test_Examples: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'MCP23008_X81.AfterReadInputs' erwartet [FEHLER] I2C_Test_Examples: C0046: Bezeichner 'MCP23008_X81' nicht definiert [FEHLER] I2C_Test_Examples: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'MCP23008_X81.BeforeWriteOutputs' erwartet [FEHLER] I2C_Test_Examples: C0046: Bezeichner 'MCP23008_X81' nicht definiert Kompilierung abgeschlossen -- 5 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 5 Fehler, 0 Warnungen : Kein Download möglich Als Device habe ich Name: CODESYS Control for Raspberry Pi SL Hersteller: CODESYS Kategorien: SoftMotion Steuerungen Version: 4.13.0.0 Bestellnummer: 2302000009 Beschreibung: Eine Soft-SPS nach IEC 61131-3 für Raspberry Pi. CODESYS Control basiert auf CODESYS SDK 3.5.20.20, Release . Das ganze unabhängig von der Codesys Version
Last updated: 2025-10-06

Post by hprog on Codesys 3.5.20/21 Import Geräterepository bzw. Bibliothen Repository funktioniert nicht CODESYS Forge talk (Post)
Hallo, Ich habe schon mehrfach Treiber für I2C Geräte geschrieben und keine Probleme mit dem Einbinden gehabt, aber derzeit komme ich auf keinen grünen Zweig. Der Import des Geräterepository (xml) funktioniert, der Import ins Bibliothekenrepository funktioniert auch, aber wenn ich dann das Gerät an den I2C MAster anfüge funktioniert der Import in das Projektbibiothek nicht und somit wird auch der entsprechende FB nicht instanziert und ich bekomme folgende Fehlermeldungen ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] I2C_Test_Examples: MCP23008_X81 [Device: I²C: I2C_master]: Bibliothek Raspberry I2C MCP23008_X81, 1.1.0.1 (3S - Smart Software Solutions GmbH) konnte nicht eingefügt werden: [FEHLER] I2C_Test_Examples: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'MCP23008_X81.AfterReadInputs' erwartet [FEHLER] I2C_Test_Examples: C0046: Bezeichner 'MCP23008_X81' nicht definiert [FEHLER] I2C_Test_Examples: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'MCP23008_X81.BeforeWriteOutputs' erwartet [FEHLER] I2C_Test_Examples: C0046: Bezeichner 'MCP23008_X81' nicht definiert Kompilierung abgeschlossen -- 5 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 5 Fehler, 0 Warnungen : Kein Download möglich Als Device habe ich Name: CODESYS Control for Raspberry Pi SL Hersteller: CODESYS Kategorien: SoftMotion Steuerungen Version: 4.13.0.0 Bestellnummer: 2302000009 Beschreibung: Eine Soft-SPS nach IEC 61131-3 für Raspberry Pi. CODESYS Control basiert auf CODESYS SDK 3.5.20.20, Release . Das ganze unabhängig von der Codesys Version
Last updated: 2025-10-06