Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06
Post by hanoues on setting date and time on CPX-E
CODESYS Forge
talk
(Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21
Post by tortilla on J1939 connection between two devices
CODESYS Forge
talk
(Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23
Post by wollvieh on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
Here a code for an Operation Counter with : days,hours,minutes,seconds as an example, maybe it points you the right direction ? FUNCTION_BLOCK OperationDayHour VAR_INPUT IN : BOOL; // Betrieb Takt : BOOL; // 1Hz Systemtakt END_VAR VAR_OUTPUT BetrTag : UDINT; // Ausgabe Betriebstage Betrstd : UDINT; // Ausgabe Betriebsstunden Betrmin : UDINT; // Ausgabe Betriebsminuten Betrsec : UDINT; // Ausgabe Betriebsekunden BetrString : STRING; // Ausgabe als String END_VAR VAR ///Erkennung Taktflanke Flanke: R_TRIG; END_VAR VAR_IN_OUT BetrsecAbsolut: UDINT; //Ein/Ausgangsvariable Betriebssekunden RETAIN !!! END_VAR Flanke(CLK:= Takt, Q=> ); (*Erkennung Taktflanke*) IF (IN AND Flanke.Q) THEN (*Sekunden hochzählen*) BetrsecAbsolut := BetrsecAbsolut + 1; END_IF Betrsec := BetrsecAbsolut MOD 60; Betrmin := ( BetrsecAbsolut / 60) MOD 60; Betrstd := ( BetrsecAbsolut / 60 / 60 ) MOD 24; BetrTag := ( BetrsecAbsolut / 60 / 60 /24 ); BetrString := RIGHT ( UDINT_TO_STRING( BetrTag + 100000),5); BetrString := CONCAT (BetrString, 'd_'); BetrString := CONCAT (BetrString,RIGHT ( UDINT_TO_STRING( Betrstd + 100000),5)); BetrString := CONCAT (BetrString, 'h_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrmin + 100),2)); BetrString := CONCAT (BetrString, 'm_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrsec + 100),2)); BetrString := CONCAT (BetrString, 's');
Last updated: 2024-05-27
Post by caprez95 on Trace Restart Visuelement
CODESYS Forge
talk
(Post)
Hallo zusammen. Ich habe schon länger mit dem Problem zu kämpfen, dass ich einen Trend (Visuelement) nicht resetten (neustarten) kann. Ich habe es jetzt mit dem Beispiel hinbekommen, die Trace-Aufzeichnung über die CmpTraceMgr Bibliothek zu steuern. Aber wie bekomme ich diese Trace-Aufzeichnung in ein Visuelement? Der Code sieht wie folgt aus: // Configure trace IF xInit THEN // Create a trace packet PacketConfig.pszName := ADR('IECTraceConfiguration.Trace1'); // Name of trace PacketConfig.pszApplicationName := ADR('IECTraceConfiguration'); // Name of the application PacketConfig.pszIecTaskName := ADR('Task'); // Name of the task PacketConfig.pszComment := ADR('Demo packet'); PacketConfig.ulEveryNCycles := 1; PacketConfig.ulBufferEntries := 1000; PacketConfig.ulFlags := TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_TIMESTAMP_MS AND TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_AUTOSTART; IF (NOT fbTraceManager.CreatePacket(PacketConfig := PacketConfig, hPacket=>hPacket1)) THEN xError := TRUE; END_IF // Create a trace record RecordConfig.pszVariable := ADR('iSignal'); // This is the name of variable to record RecordConfig.tcClass := INT_TO_UDINT(TypeClass.TYPE_INT); // Type of the recording variable RecordConfig.ulSize := SIZEOF(iSignal); // Size of the recording variable pApp := AppFindApplicationByName('IECTraceConfiguration', 0); AppGetAreaOffsetByAddress(pApp, ADR(iSignal), ADR(RecordConfig.tvaAddress.taAddress.Area.usArea), ADR(RecordConfig.tvaAddress.taAddress.Area.ulOffset)); // Get and set area offsets RecordConfig.tvaAddress.ulAddressFlags := TRACE_VAR_ADDRESS_FLAGS_IEC OR TRACE_VAR_ADDRESS_FLAGS_AREA_OFFSET; RecordConfig.ulGraphColor := 16#FF00FF00; // green RecordConfig.ulGraphType := 1; // Line with points IF (NOT fbTraceManager.AddRecord(RecordConfig := RecordConfig, hPacket := hPacket1, hRecord => hRecord1)) THEN xError := TRUE; END_IF xInit := FALSE; END_IF // Starts the recording IF xStart THEN IF (NOT fbTraceManager.StartPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStart := FALSE; END_IF // Stop the recording IF xStop THEN IF (NOT fbTraceManager.StopPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStop := FALSE; END_IF // Reset the recording IF xReset THEN IF (NOT fbTraceManager.ResetPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xReset := FALSE; END_IF
Last updated: 2024-06-04
Post by caprez95 on Trace Restart Visuelement
CODESYS Forge
talk
(Post)
Hello everyone. I've been struggling with the problem for a long time that I can't reset (restart) a trend (visual element). With the example I have now managed to control the trace recording via the CmpTraceMgr library. But how do I get this trace recording into a visual element? The code looks like this: // Configure trace IF xInit THEN // Create a trace packet PacketConfig.pszName := ADR('IECTraceConfiguration.Trace1'); // Name of trace PacketConfig.pszApplicationName := ADR('IECTraceConfiguration'); // Name of the application PacketConfig.pszIecTaskName := ADR('Task'); // Name of the task PacketConfig.pszComment := ADR('Demo packet'); PacketConfig.ulEveryNCycles := 1; PacketConfig.ulBufferEntries := 1000; PacketConfig.ulFlags := TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_TIMESTAMP_MS AND TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_AUTOSTART; IF (NOT fbTraceManager.CreatePacket(PacketConfig := PacketConfig, hPacket=>hPacket1)) THEN xError := TRUE; END_IF // Create a trace record RecordConfig.pszVariable := ADR('iSignal'); // This is the name of variable to record RecordConfig.tcClass := INT_TO_UDINT(TypeClass.TYPE_INT); // Type of the recording variable RecordConfig.ulSize := SIZEOF(iSignal); // Size of the recording variable pApp := AppFindApplicationByName('IECTraceConfiguration', 0); AppGetAreaOffsetByAddress(pApp, ADR(iSignal), ADR(RecordConfig.tvaAddress.taAddress.Area.usArea), ADR(RecordConfig.tvaAddress.taAddress.Area.ulOffset)); // Get and set area offsets RecordConfig.tvaAddress.ulAddressFlags := TRACE_VAR_ADDRESS_FLAGS_IEC OR TRACE_VAR_ADDRESS_FLAGS_AREA_OFFSET; RecordConfig.ulGraphColor := 16#FF00FF00; // green RecordConfig.ulGraphType := 1; // Line with points IF (NOT fbTraceManager.AddRecord(RecordConfig := RecordConfig, hPacket := hPacket1, hRecord => hRecord1)) THEN xError := TRUE; END_IF xInit := FALSE; END_IF // Starts the recording IF xStart THEN IF (NOT fbTraceManager.StartPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStart := FALSE; END_IF // Stop the recording IF xStop THEN IF (NOT fbTraceManager.StopPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStop := FALSE; END_IF // Reset the recording IF xReset THEN IF (NOT fbTraceManager.ResetPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xReset := FALSE; END_IF
Last updated: 2024-06-04
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I have a Raspberry Pi 4 we have been using for years to run CODESYS for development purposes. I recently have had to re-install the OS (Raspberry OS lite). The only change to the default configuration is not creating the "pi" user during install. I (apparently successfully) installed the 4.10.0.0 control on the Raspberry Pi. We have licences on a dongle. I am able to start the control. systemctl status shows it as running for a little while (exactly, precisely 30 seconds as per my tests, every time), then it becomes exited. I can restart the control, and the same thing happens again. Every time. In the brief moments it is running, I can log in to the PLC. Working fast and restarting the control many times, I have been able to configure users. I have been able to download my application. I have been able to run the application, and stop on a breakpoint. I have been able to connect with the licence manager and confirm the dongle is detected and licences are listed as OK. I see nothing wrong until the service just exits. I have found nothing in the logs. It is like the runtime just terminates with no error code or message after exactly 30 seconds. Any help would be appreciated.
Last updated: 2024-06-13
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
yes but impossible to upload runtime 4.9.0.0 now we have put an image on the sd card with 4.13.0.0, i have 27 error message to this type, and if i test some output not work, et some work ------ Processus de compilation entamé : application : Device.HiddenOnlineConfigModeApp ------- Affecter un type à un code... [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0032: Le type 'Type inconnu : 'ADR(GVL_Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1.Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1)'' ne peut pas être converti en type 'POINTER TO IoConfigParameter' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0077: Type inconnu : 'GVL_Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1.Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0046: Identificateur 'GVL_Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1' non défini [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0032: Le type 'Type inconnu : 'ADR(GVL_Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1.Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1)'' ne peut pas être converti en type 'POINTER TO IoConfigParameter' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0077: Type inconnu : 'GVL_Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1.Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0046: Identificateur 'GVL_Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1' non défini [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0032: Le type 'Type inconnu : 'ADR(GVL_Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4.Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4)'' ne peut pas être converti en type 'POINTER TO IoConfigParameter' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0077: Type inconnu : 'GVL_Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4.Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0046: Identificateur 'GVL_Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4' non défini [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj
Last updated: 2025-10-26
Post by farren on How to stay in a method until something is finished.
CODESYS Forge
talk
(Post)
I know I'm thinking about this wrong -- too many decades of procedural and event-driven programming and only a few months of PLC ST programming...... I've created a visualization with a button that when pushed calls a method. I want the method to take a pressure reading, wait one minute and then take another pressure reading. I'm looking for leaks. I'm using TON for the delay. It seems like what is happening is that the method gets called once and it takes the first reading and starts the TON. But then execution continues, leaves that method call, and the second reading never happens. I can force the method to keep running until the whole thing is done with a While loop, but I understand that is considered BAD in PLC programming. If it push the button again to call the method again, it picks up where it left off and if the timer is complete then it runs the remaining code. How do I keep that method running until it is complete with just one call without using a while loop that ties up the PLC for a minute? Thanks! -Farren
Last updated: 2025-10-31
Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs
CODESYS Forge
talk
(Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31
Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation
CODESYS Forge
talk
(Post)
Good morning, I’ve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object I’m running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I don’t understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesn’t report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case I’m working on an isolated single core. I’ve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. I’d like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11
Post by bschraud on Speicherbegrenzung für lokale Variablen
CODESYS Forge
talk
(Post)
Aufgrund einer Schnittstellenänderung muss ich meine Messagebuffer erheblich vergrößern. U.g. Konstante bestimmt die Größe einer Byte-Array-Definition, die in einer Struktur für 9 Botschaften verwendet wird. Ich benötige also 177372byte zusätzlichen Speicher in dem Modul in dem die Struktur als lokale Variable angelegt wird. Dynamisches Allokieren zur Laufzeit möchte ich vermeiden, damit ich nicht während des Betriebes Fehler aus dem Allokieren behandeln muss. Für ein Reservieren des Speicherbereiches habe ich in Codesys keine Einstellmöglichkeiten gefunden. Die Applikation läßt sich ohne weitere Modifikation kopilieren, scheitert aber bei der Ausführung. Welche Lösungs- oder Einstellmöglichkeiten gibt es? Bei c_w_process_result_content_len_max: WORD := 292; [INFORMATION] Größe des lizenzierten Benutzercodes: 363304 Bytes [INFORMATION] Speicherverbrauch auf dem Gerät, nicht für Lizenzierung verwendet: [INFORMATION] Speicherbereich 0 enthält Daten, Eingang, Ausgang, Speicher und Nicht-sichere Daten: Größe: 2807632 Bytes , höchste verwendete Adresse: 2159712, größte zusammenhängende Speicherlücke: 647920 Bytes (23 %) [INFORMATION] Speicherbereich 3 enthält Code: Größe: 7267784 Bytes , höchste verwendete Adresse: 5590600, größte zusammenhängende Speicherlücke: 1677184 Bytes (23 %) Übersetzung abgeschlossen -- 0 Fehler, 10 Warnungen : Bereit für Download Speicherprüfung: [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag GVL.htFactory._itfInstList.__Interface in Area 0, Offset 0x000033BC (0x71C15414) [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag __datasourcesInstancesGVL.__datasourcesInstances.dsInst._allItemsHashtable._ht.__Interface in Area 0, Offset 0x00128904 (0x71D3A95C) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_L_Instance._IIoDrv.__Interface in Area 0, Offset 0x0018EC00 (0x71DA0C58) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_S_DAC_Instance._IIoDrv.__Interface in Area 0, Offset 0x0018F090 (0x71DA10E8) [INFORMATION] PAC: Überprüfter Speicher für 21336 Objekte. 4 Prüfung(en) fehlgeschlagen. [INFORMATION] PAC: Check took 00:00:13.9743220. Applikation lässt sich downloaden und funktioniert auf dem Gerät. Nach der Vergrößerung: c_w_process_result_content_len_max: WORD := 20000; [INFORMATION] Größe des lizenzierten Benutzercodes: 363304 Bytes [INFORMATION] Speicherverbrauch auf dem Gerät, nicht für Lizenzierung verwendet: [INFORMATION] Speicherbereich 0 enthält Daten, Eingang, Ausgang, Speicher und Nicht-sichere Daten: Größe: 4114264 Bytes , höchste verwendete Adresse: 3164816, größte zusammenhängende Speicherlücke: 949448 Bytes (23 %) [INFORMATION] Speicherbereich 3 enthält Code: Größe: 7267832 Bytes , höchste verwendete Adresse: 5590640, größte zusammenhängende Speicherlücke: 1677192 Bytes (23 %) Übersetzung abgeschlossen -- 0 Fehler, 10 Warnungen : Bereit für Download Speicherprüfung: (gleiches Ergebnis wie vorher) [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag GVL.htFactory._itfInstList.__Interface in Area 0, Offset 0x000033BC (0x71C15414) [WARNUNG] PAC: MC0006: Pointeradresse außerhalb des verwalteten Speichers für Eintrag __datasourcesInstancesGVL.__datasourcesInstances.dsInst._allItemsHashtable._ht.__Interface in Area 0, Offset 0x0021DF38 (0x71E2FF90) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_L_Instance._IIoDrv.__Interface in Area 0, Offset 0x00284238 (0x71E96290) [WARNUNG] PAC: MC0009: Pointer to Interface zeigt nicht auf die erwartete Schnittstelle in einer FB-Instanz für Eintrag IoConfig_Globals.PiXtend_V2_S_DAC_Instance._IIoDrv.__Interface in Area 0, Offset 0x002846C8 (0x71E96720) [INFORMATION] PAC: Überprüfter Speicher für 21336 Objekte. 4 Prüfung(en) fehlgeschlagen. [INFORMATION] PAC: Check took 00:00:14.0491831. Applikation lässt sich downloaden. Ausführen mündet in Ausnahmefehler Die Applikation läuft auf der Runtime CODESYS Control for Raspberry Pi MC SL. Die Codesys Version ist 3.5 SP20 mit allen Updates. Kennt jemand eine Speichergrenze für lokale Variablen bzw. eventuelle Einstellmöglichkeiten? Vielen Dank
Last updated: 2024-05-06
Post by harryc on Soft Container License issue with ARM64 Linux
CODESYS Forge
talk
(Post)
Hi, We are working to provide our customers with CODESYS operation on our hardware product ( https://elprotech.com/product/el-qe-e-quantum-edge-series/ ). I'm trying to enable a CODESYS license (Soft container) on our product running ARM64 linux. This problem am having looks similar to here: https://forge.codesys.com/forge/talk/Runtime/thread/6d29b6b4de/ and here: https://forge.codesys.com/forge/talk/Runtime/thread/a2d0c63375/; but I am not running docker, and I am not re-installing a license. This is first time install. I have CODESYS Control SL running on my device, as well as CodeMeter. I purchased a license, and installed it to the CODESYS Development system, (Tools >> License Repository) then tried to install to the device (Tools >> License Manager >> o Device >> o Soft container >> Remote [0001] >> OK. This gives me the "License Manager - Overview" dialog, and the message "Licensing info not available. There is no dongle attached to the device." Below shows the running applications, installed packages, and current content of /var/opt/codesys Also attached screenshots of the Development software as I go through the steps to install the license. # # ps | grep -e "code" -e "CodeMeter" 1391 daemon /usr/sbin/CodeMeterLin 1407 root /opt/codesys/bin/codesyscontrol.bin /etc/codesyscontrol/CODESYSControl.cfg 1442 root /opt/codesysedge/bin/codesysedge.bin /etc/codesysedge/Gateway.cfg 29229 root grep -e code -e CodeMeter # dpkg -l Desired=Unknown/Install/Remove/Purge/Hold | Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend |/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad) ||/ Name Version Architecture Description +++-==============-=============-============-============================================================================================== ii codemeter-lite 8.20.6539.500 arm64 WIBU CodeMeter minimal runtime ii codesyscontrol 4.14.0.0 arm64 codesyscontrol based on SDK 3.5.20.40 , from Fri Nov 29 08:35:37 CET 2024 [265], Release build ii codesysedge 4.14.0.0 arm64 codesysedge based on SDK 3.5.20.40 , from Fri Nov 29 08:34:19 CET 2024 [265], Release build # ls -la /var/opt/codesys total 208 drwxr-xr-x 6 root root 4096 Nov 7 05:31 . drwxr-xr-x 1 root root 4096 Nov 6 08:33 .. -rw-r--r-- 1 root root 23515 Nov 7 07:26 .Audit.log -rw-r--r-- 1 root root 160 Nov 7 05:31 .GroupDatabase.csv -rw-r--r-- 1 root root 160 Nov 7 04:37 .GroupDatabase.csv_ -rw-r--r-- 1 root root 20736 Nov 29 2024 .SoftContainer_CmRuntime.wbb -rw-r--r-- 1 root root 1982 Nov 29 2024 .UFC_SoftContainer_CmRuntime.WibuCmLif -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv_ -rw-r--r-- 1 root root 11807 Nov 7 05:30 .UserMgmtRightsDB.csv drwxr-xr-x 6 root root 4096 Nov 6 08:30 .pki drwxr-xr-x 3 root root 4096 Nov 6 08:30 OPCUAServer drwxr-xr-x 7 root root 4096 Nov 6 08:30 PlcLogic -rw-r--r-- 1 root root 13 Nov 6 08:30 SysFileMap.cfg -rw-r--r-- 1 root root 2640 Nov 29 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Nov 6 08:30 cert -rw-r--r-- 1 root root 94105 Nov 7 07:25 codesyscontrol.log # # uname -a Linux Remote 6.1.22 #5 SMP PREEMPT Tue Nov 18 11:35:46 AEST 2025 aarch64 GNU/Linux #
Last updated: 17 hours ago
Post by manuknecht on Opening a Dialog on a specific Client from ST
CODESYS Forge
talk
(Post)
I managed to find a solution that seems to work reliably. As the VU.Globals.CurrentClient-filter accesses the CURRENTCLIENTID or at least a similar, internal variable it can only be used if called from a certain client (e.g. from a button in a visualization). My solution works by implementing a new client filter that compares the client ID of all clients to the ID of the last client that was used. The variable containing the data of the last client is defined as: G_LastClient : VU.IVisualizationClient; // Copy of last client that detected click This last client is then updated every time a button is pressed using the Execute ST-Code input configuration of the button: G_LastClient := VU.PublicVariables.Clients.Current; Next, I created a function block that implements the client filter interface as so: FUNCTION_BLOCK FB_LastClientFilter IMPLEMENTS VU.IVisualizationClientFilter VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR END_VAR Then i added a method to the FB called IsAccepted which is used to filter out the client. When creating the method, it should automatically be filled with the according variable declaration, as it is defined in the interface: (* For every client can be desided, if it is accepted. ``TRUE``: Client is accepted*) METHOD IsAccepted : BOOL VAR_INPUT (* The client, to check*) itfClient : VU.IVisualizationClient; END_VAR Now the client can be compared to the last used client as such: // check if clientID corresponds to clientID of last recorderd client IF itfCLient.ClientId = G_LastClient.ClientId THEN IsAccepted := TRUE; ELSE IsAccepted := FALSE; END_IF To make use of this custom client filter, initialize a variable with the client filter: LastClient : FB_LastClientFilter; // Client filter to find last used client Then use this client filter when opening or closing a dialog from ST: fbOpenMyDialog(itfClientFilter:=LastClient,xExecute:=TRUE,sDialogName:='VIS_MyDialog_DLG');
Last updated: 2023-09-27
Post by maldus512 on How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Post)
Hello everyone, I have been given the task to develop I/O drivers for a custom made, Linux based board to allow for Codesys applications to run and control the hardware. I have successfully installed Codesys Control SL for ARM/Linux and tested it with a simple demo application. Now I should start interfacing the runtime to the actual hardware; I should be able to interact with 2 RS485 serial ports, a few GPIOs and an I2C port, all of which already have the corresponding /dev/ interface in the Linux system. I am having trouble understanding how it should be approached. I have found sporadic references that fail to lead to a really comprehensive documentation. For example: The store page (https://store.codesys.com/en/codesys-control-for-linux-arm-sl-1.html#options) mentions a "runtime package" that should allow "Integration of existing C code" and "Usage of local I/Os", which seems exactly what I need to interact with custom peripherals. I have found no further reference to Codesys-C interpop. The Codesys Help page for the runtime package has a page on the "Development of Drivers" (https://content.helpme-codesys.com/en/CODESYS%20Control/rtsllinuxrbpdriverdevelopment.html) that suggests to either "Implement a function block" or "Implement I/O drivers". Those in turn lead to this page (https://forge.codesys.com/drv/io-drivers/doc/Generic/) which describes briefly an XML schema to describe new devices; unfortunately, it doesn't mention what to do with such a description (i.e. how does the runtime know about it) or how it is in any way connected to the actual hardware. Could anyone give me some pointers? I should also mention I have no prior experience with Codesys, so maybe I'm missing an obvious answer.
Last updated: 2024-08-09
Post by jeffg on ERROR: GetNetLinkSockAndInfoByMac(): could not open netlink socket: Too many open files
CODESYS Forge
talk
(Post)
I just installed codesys runtime on a raspberry pi Cortex-A72 (ARM v8) 64-bit SoC @ 1.5GHz (Compute Module 4) I am running on Codesys control for raspberry pi 64 SL ver 4.13.0 and I keep getting a crash after about five to ten minutes. This program was running fine on a 32bit system with runtime 4.8 previously but they upgraded the panel PC cause it got smashed. Looking at the logs I see this error "ERROR: GetNetLinkSockAndInfoByMac(): could not open netlink socket: Too many open files" at the time of crash. I do have a UDP socket open for a serial to ethernet adapter and im wondering if maybe its opening a bunch of sockets and while receiving messages, Im not sending anything to the device only receiving. Below is the code used for the UDP VAR // Scale Comm fbPeerServer : NBS.UDP_Peer; ipAddress : NBS.IPv4Address; fbReceive : NBS.UDP_Receive; xPeerActiv : BOOL := TRUE; abyReceive : ARRAY [0..255] OF BYTE; sLastValidReceive : STRING(255); udiIndex : UDINT; END_VAR IF xPeerActiv AND NOT fbPeerServer.xBusy THEN ipAddress.SetInitialValue(ipAddress := gvlSettings.sIPAddres); fbPeerServer(xEnable := TRUE, itfIPAddress := ipAddress, uiPort := gvlSettings.uiPort); END_IF fbPeerServer(); fbReceive(xEnable := fbPeerServer.xBusy, itfPeer := fbPeerServer, pData := ADR(abyReceive), udiSize := SIZEOF(abyReceive)); IF fbReceive.udiCount > 0 THEN IF fbReceive.udiCount < SIZEOF(sLastValidReceive) THEN SysMem.SysMemCpy(pDest := ADR(sLastValidReceive), pSrc := ADR(abyReceive), udiCount := fbReceive.udiCount); // Set End of String sLastValidReceive[fbReceive.udiCount] := 0; END_IF END_IF If anyone as seen this I could really use some help figuring it out. I included the Log report
Last updated: 2024-09-19
Post by gorditron on I2C Communication with
CODESYS Forge
talk
(Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag für die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte für den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer für den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer für die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle für das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13
Post by edson-bueno on SysProcess Execute Command unable to run commands with special characters
CODESYS Forge
talk
(Post)
Hi, I found the same issue, and I fixed with this steps: 1st go to codesys .cfg file. sudo nano CODESYSControl.cfg Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll Now we need to grant codesys root rights on Linux. Step 1: Create or edit the systemd override configuration: sudo systemctl edit codesyscontrol In the editor that opens, insert: [Service] User=root Save and exit: Press Ctrl+O to save Press Ctrl+X to exit Step 2: Reload systemd and reboot To apply the override: sudo systemctl daemon-reexec sudo systemctl daemon-reload sudo reboot Step 3: Confirm CODESYS is running as root After reboot, open the terminal and run: ps aux | grep codesyscontrol You should see something like: root 1234 ... /opt/codesys/bin/codesyscontrol.bin ... If instead it shows admin or another user, the override was not applied correctly. Step 4: (Optional) Confirm from within CODESYS In your CODESYS project, insert this test code to run the Linux command whoami: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR refCommand REF= sCommand; refOutput REF= sOutput; SysProcessExecuteCommand2( pszCommand := refCommand, pszStdOut := refOutput, udiStdOutLen := SIZEOF(sOutput), pResult := ADR(resultCmd) ); Notes & Warnings This method gives full system access to the CODESYS runtime — do not expose this system to the public network without protection. Do not use sudo in commands inside CODESYS when the runtime is already running as root. @tomas111, in case you want to read the temperatur, use this command: sCommand:STRING:='/usr/bin/vcgencmd measure_temp';
Last updated: 2025-05-20
Post by laurits on Max lines of code, codesys CNC ?
CODESYS Forge
talk
(Post)
Hi, yes now its working, to get "QUEUE.bFull" to work, I've had to set the "QUEUE.nNumReservedEntries" to 3. (I tried different values here, only effect for larger values i can see is the the queue capacity gets smaller.) I've noticed the movement is slowing down when it reaches the end of the "fill Up", must be because of the "checkVelocity" can only see the current "QUEUE". Any way of solving this ? BUF : ARRAY[0..20000] OF SMC_GEOINFO; xp : ARRAY[1..100000] OF REAL; yp : ARRAY[1..100000] OF REAL; CASE iState OF 000: IF R_TRIG_bStart.Q THEN iState := iState + 1; END_IF bReady := FALSE; //initialize Queue GEO.dT1:=0; GEO.dT2:=1; GEO.dToolRadius := 0; GEO.dVel := 15000; GEO.dVelEnd := 15000; GEO.dAccel := 2000; GEO.dDecel := 2000; GEO.iObjNo := 0; GEO.piDestPos.dX := 0; GEO.piDestPos.dY := 0; QUEUE.bEndOfList := FALSE; QUEUE.nPastMarker := -1; QUEUE.nWritePos := 0; QUEUE.pbyBuffer := ADR(BUF[0]); n := 0; sMC_CheckVelocities(bExecute:= FALSE); SM3_CNC.SMC_SetQueueCapacity(ADR(QUEUE), SIZEOF(BUF)); QUEUE.nNumReservedEntries := 3; 001: FOR i := 1 TO SIZEOF(xp)/SIZEOF(xp[1]) DO xp[i] := UDINT_TO_REAL(i) * 0.01; yp[i] := UDINT_TO_REAL(i) * 0.01; END_FOR iState := iState + 1; 002: WHILE NOT QUEUE.bFull DO // when the Queue is full, wait until it has been processed by the following FBs n := n + 1; GEO.iSourceLine_No := n; GEO.piStartPos := GEO.piDestPos; // copy last destination GEO.iMoveType := LIN; // generate linear movement GEO.iObjNo := GEO.iObjNo + 1; // calculate number GEO.piDestPos.dX := xp[n]; // generate position GEO.piDestPos.dY := yp[n]; SMC_CalcLengthGeo(pg := ADR(GEO)); // calculate length of object with the help of the standard function SMC_AppendObj(poq:=ADR(QUEUE), pgi:=ADR(GEO)); //append object to queue IF n = UDINT_TO_DINT( SIZEOF(xp)/SIZEOF(xp[1])) THEN // all target positions processed QUEUE.bEndOfList := TRUE; iState := iState + 1; EXIT; END_IF END_WHILE sMC_CheckVelocities(bExecute:= TRUE, poqDataIn:= ADR(QUEUE)); bReady := TRUE; // Send message to smc_interpolator to start 003:
Last updated: 2025-06-04
Post by jami on Reading multiple lines from csv file
CODESYS Forge
talk
(Post)
Hello, i am trying to read multiple lines from csv file with caa file library and oscat. I have wrote 7 lines in the csv with separation '$R$L'. In my "extracting values" part I check line feeds and chars. After that I convert my buffer to string with oscat but I'm only able to read the first line from the csv. No matter if I even change start position where I start converting the buffer, I only get the first line. Here's my code for the reading and extracting value parts: 4: (*Reading the file*) fileread.hFile := filehandle; fileread.pBuffer := ADR(buffer); filesize1:=SIZEOF (buffer); fileread.szbuffer:=filesize1; fileread.udiTimeOut := 100000; fileread(xExecute := TRUE); IF fileRead.xDone THEN iFilesize:=TO_INT(fileread.szSize); writestate:=3; fileRead.xExecute := FALSE; END_IF 5: (*Extracting values*) //here i check the number of line feeds and chars. It works WHILE i < ifilesize DO c:=buffer[i]; IF c= 10 THEN IF lineindex<=99 THEN lineIndex := lineIndex + 1; END_IF ELSIF c <> 13 THEN IF charIndex <= 1000 THEN charIndex := charIndex + 1; END_IF END_IF i := i + 1; END_WHILE // Here i convert the buffer to string and transfer it to filelines:ARRAY[0..99] of string[254]. trig(CLK:=BUTTON); IF trig.Q THEN fileLines[i2]:=oscat_basic.BUFFER_TO_STRING(PT:=ADR(buffer), Size:=TO_UINT(fileread.szBuffer), start:=TO_UINT(bufferStart), stop:=TO_UINT(filesize1)); i2:=i2+1; bufferstart:=bufferstart+80; END_IF If anyone has idea how to read multiple lines, it would be nice. Even if you have example codes that work, that would help a lot.
Last updated: 2025-07-18
Post by timvh on Get Alarm status in Codesys
CODESYS Forge
talk
(Post)
You are right, that you can use the GetState method, but it is not that simple. You first have to get a list of (filtered) alarms from the AlarmManager. You can find an example in Forge how to do this. See https://forge.codesys.com/prj/codesys-example/alarm-manager/home/Home/ Then you can go through this list to get the state of all the (filtered) alarms. See below the code which you could use. This is all based on the example from forge. Create a program: // This example shows how to access alarms via structured text. PROGRAM PLC_PRG VAR xInit : BOOL := TRUE; udiResult : UDINT; fbAlarmFilterCriteriaAll : FB_AlarmFilterCriteriaAll; fbAlarmManagerClient : FB_AlarmManagerClient; itfAlarmManagerClient : IAlarmManagerClient := fbAlarmManagerClient; xAlarm1 : BOOL; xAlarm2 : BOOL; xWarning : BOOL; iNrOfAlarmsInAlarmList : INT; iNrOfActiveAlarmsInAlarmList : INT; paitfAlarm: POINTER TO ARRAY [0..0] OF AlarmManager.IAlarm; iAlarmIndex : INT; eAlarmState: AlarmManager.AlarmState; END_VAR IF xInit THEN xInit := FALSE; fbAlarmManagerClient.itfAlarmFilterCriteria := fbAlarmFilterCriteriaAll; // register alarm client to get updated about alarm status / changes udiResult := AlarmManager.g_AlarmHandler.RegisterClient(itfAlarmManagerClient, 0, 0); END_IF // Polling the number of alarms udiResult := AlarmManager.g_AlarmHandler.GetActiveAlarms(itfAlarmManagerClient, parritfActiveAlarms => paitfAlarm, iCountActiveAlarms => iNrOfAlarmsInAlarmList); iAlarmIndex := 0; iNrOfActiveAlarmsInAlarmList := 0; WHILE iAlarmIndex < iNrOfAlarmsInAlarmList DO eAlarmState := paitfAlarm^[iAlarmIndex].GetState(); IF eAlarmState = AlarmManager.AlarmState.Active OR eAlarmState = AlarmManager.AlarmState.ActiveAcknowledged THEN iNrOfActiveAlarmsInAlarmList := iNrOfActiveAlarmsInAlarmList + 1; END_IF iAlarmIndex := iAlarmIndex + 1; END_WHILE See below some details about the function blocks: One function block should implement the IAlarmFilterCriteria interface. This can be empty except a few methods. FUNCTION_BLOCK FB_AlarmFilterCriteriaAll IMPLEMENTS AlarmManager.IAlarmFilterCriteria Method implementation (others related to interface are empty) METHOD AreAllAlarmClassesSelected : BOOL AreAllAlarmClassesSelected := TRUE; METHOD AreAllAlarmGroupsSelected : BOOL AreAllAlarmGroupsSelected := TRUE; METHOD GetPriorityFrom : USINT GetPriorityFrom := 0; METHOD GetPriorityTo : USINT GetPriorityTo := 255; The other function block should implement IAlarmManagerClient and get a reference to the FB which implements the IAlarmFilterCriteria FUNCTION_BLOCK FB_AlarmManagerClient IMPLEMENTS AlarmManager.IAlarmManagerClient VAR_INPUT itfAlarmFilterCriteria: AlarmManager.IAlarmFilterCriteria; END_VAR Method implementation (others related to the interface are empty) METHOD GetFilterCriteria : AlarmManager.IAlarmFilterCriteria // see VAR_INPUT for filter GetFilterCriteria := itfAlarmFilterCriteria; Off course you have to add the AlarmManager to your application and add some alarms to it.
Last updated: 2025-09-02
Post by matteodigani on Error using function block "Write alias address"
CODESYS Forge
talk
(Post)
Hi, I've got a problem using the function block "Write alias address" (ETCStack library 4.9.0.0). this is the code: EtherCAT_1(); IF EtherCAT_1.ConfigRead AND enable THEN CASE seq OF 0: exec := FALSE; T.IN := TRUE; T.PT := T#10S; T(); IF T.Q THEN seq := 1; T.IN := FALSE; END_IF ; 1: T.IN := FALSE; T(); //THIS ONE WORK CORRECTLY! WrAliasAdd.xAbort := FALSE; WrAliasAdd.usiCom := DWORD_TO_USINT(EtherCAT_1.InstanceNumber); WrAliasAdd.wSlaveAddress := 1002; WrAliasAdd.xAutoIncAdr := FALSE; WrAliasAdd.uiAliasAddress := 19; WrAliasAdd.udiTimeOut := 3000; IF start THEN exec := TRUE; ELSE IF NOT error THEN start := TRUE; END_IF END_IF IF WrAliasAdd.xDone THEN start := FALSE; done := TRUE; error := FALSE; exec := FALSE; seq := 5; END_IF IF WrAliasAdd.xError THEN start := FALSE; done := FALSE; error := TRUE; exec := FALSE; END_IF ; 5: exec := FALSE; T.IN := TRUE; T.PT := T#1S; T(); IF T.Q THEN seq := 10; END_IF ; 10: T.IN := FALSE; T(); //THIS ONE GIVES ME AN ERROR! WrAliasAdd.xAbort := FALSE; WrAliasAdd.usiCom := DWORD_TO_USINT(EtherCAT_1.InstanceNumber); WrAliasAdd.wSlaveAddress := 1006; WrAliasAdd.xAutoIncAdr := FALSE; WrAliasAdd.uiAliasAddress := 25; WrAliasAdd.udiTimeOut := 1000; IF start THEN exec := TRUE; ELSE IF NOT error THEN start := TRUE; END_IF END_IF IF WrAliasAdd.xDone THEN start := FALSE; done := TRUE; error := FALSE; exec := FALSE; seq := 99; END_IF IF WrAliasAdd.xError THEN start := FALSE; done := FALSE; error := TRUE; exec := FALSE; END_IF ; ELSE ; END_CASE WrAliasAdd(xExecute := exec); END_IF The first one slave ethercat works correctly, but the other one gives me an error. Attached the ethercat configuration of the devices. All the devices are set "Optional". So my idea is to enable only the first one (1002) and the fifth one (1006).
Last updated: 2025-10-01
Post by mondinmr on Why SysPipeWindows is not implemented in RTE?
CODESYS Forge
talk
(Post)
This library would be very useful for IPC communications. Using a UDP socket on localhost is unpredictable, as with slightly loaded machines it does not even guarantee packet delivery locally. Using TCP creates a lot of overhead. Message named pipes would be an excellent solution for Windows RTE. On Linux, since the release of the extension package, there is no issue, as it is sufficient to develop a component. However, although now 90% of our clients understand that Linux runtimes are better in every way compared to Windows RTE, especially from the security aspect (Not in kernel space) and the issues with Windows updates, 10% stubbornly insist (sometimes for trivial commercial reasons) on using Windows. Managing IPC with circular buffers in shared memory is quite ugly, or rather really ugly and unaesthetic. In the manuals, I saw the SysPipeWindows libraries, so I decided to test them, but unfortunately, I noticed that they are not implemented for RTE devices. Technically, I could try to open them as regular files, but SysFileOpen returns 16#27 or 16#39 depending on how I set the name (direction of the slashes). Here is the code to create shared memory and named pipes. Shared memory work great, named pipes no! #ifdef Q_OS_WIN32 SECURITY_ATTRIBUTES sa; SECURITY_DESCRIPTOR sd; InitializeSecurityDescriptor(&sd, SECURITY_DESCRIPTOR_REVISION); SetSecurityDescriptorDacl(&sd, TRUE, NULL, FALSE); sa.nLength = sizeof(SECURITY_ATTRIBUTES); sa.lpSecurityDescriptor = &sd; sa.bInheritHandle = FALSE; const wchar_t* name = L"Global\\ShmTest"; HANDLE hMapFile = CreateFileMapping( INVALID_HANDLE_VALUE, NULL, PAGE_READWRITE, 0, sizeof(SharedData), name); if (hMapFile == NULL) { qCritical("Error creating shared memory"); return 1; } data = static_cast<SharedData*>(MapViewOfFile(hMapFile, FILE_MAP_ALL_ACCESS, 0, 0, sizeof(SharedData))); if (data == NULL) { qCritical("Error mapping shared memory"); return 1; } HANDLE hPipe = CreateNamedPipe( TEXT("\\\\.\\pipe\\MyPipe"), PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_WAIT, PIPE_UNLIMITED_INSTANCES, 1024 * 1024, 1024 * 1024, NMPWAIT_USE_DEFAULT_WAIT, &sa); if (hPipe == INVALID_HANDLE_VALUE) { qCritical("Error creating named pipe"); return -1; } if (!ConnectNamedPipe(hPipe, NULL)) { qCritical("Error connecting to named pipe"); return -1; } checkPipe(hPipe); #endif
Last updated: 2024-02-02
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins
CODESYS Forge
talk
(Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.