Post by toby on Ethercat Servo Setup
CODESYS Forge
talk
(Post)
Hi Everyone, I have a simple project with a single servo, but its my first time using Codesys and motion, so I'm a little confused and lost, I've tried to read the tutorial online, but I'm not having much luck sorry. Can I please ask for some pointers. I have a ComfilePi HMI (Raspberry Pi) communicating to a Omron R88D-1SN08H-ECT amplifier. Please see the attached project file (which is better for sharing, the project file, or a archive?). This file was simply for testing the motion of the servo before anything else is tested with it. The project simply rotates the servo 1 rotation when called for, but the speed can vary based on user input. Nothing much fancy. As yet, I haven't had any servo movement, no errors on the amplifier display. How do I link the motion FBs to the physical drive? Thank you very much for any help you can offer. I'm sorry if I'm doing something very stupid or basic and getting it wrong. Have a good day. Toby
Last updated: 2023-09-20
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14
Post by alimans on Hex string
CODESYS Forge
talk
(Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20
Post by rafa on MODBUS TCP SERVER DONT AUTO-STARTUP
CODESYS Forge
talk
(Post)
Dear all, I have a project where I have two ModbusTCP communication drivers in the application. It's working normally until a power outage or the installation panel is restarted. As soon as the PLC CPU is restarted, the Ethernet port is OK, but the TCP Server displays an "UNDEFINED" error. I can't reset the error using the diagnostic confirmation or the "mbserver.xConfirmError" bit. I noticed that the error only appears in the "mbserver.byModbusError" memory and the description is "UNDEFINED." The "mbserver.xError" memory doesn't flag an error. When using the warm restart function and then START CPU, the devices return to normal operation. The following demonstration images; The main question is: How can I make devices boot automatically?
Last updated: 2025-07-15
Post by micik on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore
CODESYS Forge
talk
(Post)
I have a test application and use Codesys Control for Rasp Pi SL. I made a mistake and updated device from MSL to MC SL, and now if I try to go online with archived version of the project I gett error message that IDs are different between project device and target device. Of course, I can go online if I changed device in the project from SL to MC SL, but I'm not sure that is correct. So I have two questions: 1. What is the actual difference between MC SL device and standard SL device when it comes to raspberry pi 4? 2. What change I need to do on raspberry pi4 side to change device back from MC SL to SL? Thank you!
Last updated: 2025-08-05
Post by fleaplc on File access operation denied
CODESYS Forge
talk
(Post)
file to access has to be into the path /var/opt/codesys/PlcLogic I has same issue time ago...
Last updated: 2024-11-17
Post by tonyadrem on update data/tim
CODESYS Forge
talk
(Post)
Hello How to update the dates from timestamp to the actual time? THX!
Last updated: 2025-08-25
Post by tonyadrem on update data/tim
CODESYS Forge
talk
(Post)
Hello How to update the dates from timestamp to the actual time? THX!
Last updated: 2025-08-25
Post by sigurdrb on Network log messages
CODESYS Forge
talk
(Post)
I can also add the kernel log messages from the same time. Seems like some kind of packet storm to the PLC?
Last updated: 2025-09-11