Post by niallel on How to change bHiresMode
CODESYS Forge
talk
(Post)
Thank you so much for the reply. The motor is a rotary connected to a linear actuator. So would I set it up as in the attachment screenshot?
Last updated: 2024-03-12
Post by fless on How to change bHiresMode
CODESYS Forge
talk
(Post)
Hi, you should see 2 input fields in the scaling tab of your linear axis: increments and units in application just set increments to 10 and units in application to 366
Last updated: 2024-03-12
Post by anlebr on Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Post)
Hi I am trying use the Codesys Communication Manager to set up an Opc ua server with a custom information model. As a start I am using the Boiler model available on Opc foundations github page. I am testing with a Wago CC100 and using Codesys V3.5 SP19 Patch 6. I get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://opcfoundation.org/UA/Boiler/ with a minimal publication date from 15/12/2023 but the device has only a model from 15/09/2021 installed. Probably the information model from 15/09/2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway, both versions are available in the repository. How can I solve this?
Last updated: 2024-03-13
Post by fless on See only variable
CODESYS Forge
talk
(Post)
either you have "Insert with namespace" enabled in the SmartCoding options or your GVL_GLOBAL starts with {attribute 'qualified_only'} btw it's considered good practice to put the namespace in front of the variable. you could have variable with the same name in your PRG or FB.
Last updated: 2024-03-14
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20
Post by k4zz on Static Code Analysis
CODESYS Forge
talk
(Post)
The Solution. For Projects: #check all pool objects system.commands["project", "buildactiveapp"] #run static analysis system.commands["staticanalysis", "run"].execute() For Libraries: #check all pool objects system.commands["project", "buildactiveapp"] #run static analysis system.commands["staticanalysis", "runforlibrary"].execute()
Last updated: 2024-03-20
Post by doli on Table selected row
CODESYS Forge
talk
(Post)
Hello. So I have two visualizations. In my main visualization I have a table and in the second one I have a dialog. When I select a row I want that dialog to open. How can I do this? Thank you!
Last updated: 2024-03-20
Post by esave on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Thank you very much Florian The SoftMotionLight package is actually more expencive than the normal SoftMotion. What is exactly the difference? Does my PLC need to be compatible with SoftMotion or does this work with any PLC?
Last updated: 2024-03-22
Post by timvh on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
You should only open de COM port once and then leave it open. This hCom should not keep on incrementing. (off course when you are done communicating, you need to close the COM port)
Last updated: 2024-03-22
Post by andrew-budaiev on Properties feature request
CODESYS Forge
talk
(Post)
Can I leave a feature request here? If it's possible to do now, but I don't know how, please forgive me. It would be good if the following were possible: Ability to copy/paste properties. Ability to tab through properties.
Last updated: 2024-03-26
Post by kuuki on Losing focus of variable
CODESYS Forge
talk
(Post)
Hi. Does anyone know how to fix a problem with losing focus of a variable in FBD editor. Sometimes when trying to edit variable name, array index, etc. in network, editor randomly exits "text edit mode" and variable is replaced by text you were typing.
Last updated: 2024-03-26
Post by esave on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Hello @ph0010421 Thanks for you answer. I dont really get the state machine that you sent me. Is that only for enabling the drive? How can i make movement? Is this with these SDO's? What is SDO exactly? Sorry but i am a little lost (:|)
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by jetme on Rampup and rampdown
CODESYS Forge
talk
(Post)
i'm using FB Ramp_INT function to ramp my pump up and down but I will like to ramp up at a different time and also ramp down at a different time. How can I do that.
Last updated: 2024-03-28
Post by andrew-budaiev on Tank Level Display
CODESYS Forge
talk
(Post)
If I want to display level in the tank, what's usual approach? Is there tank or vessel element I can use? I see there is bar display, but I can't make it fill the shape I need.
Last updated: 2024-04-03
Post by simonh on Datasource OPC UA Client error ID:7012
CODESYS Forge
talk
(Post)
Hello, did you find the solution for the communication?Has the communication between the two been successful? if yes, can you please share me your solution since i have similar issue now. Thanks.
Last updated: 2024-04-04
Post by markosrod on Problem with the license of libraries IIoT
CODESYS Forge
talk
(Post)
hello people, im having this issue when i try to validate the libraries. im using a device and a softcontainer. I tried with two different Keys and nothing. Please help with this.
Last updated: 2024-04-04
Post by correo0269 on Problems with Raspberry Pi - IoDrvGPIO library
CODESYS Forge
talk
(Post)
Yes, but I want to use 1-wire and I2C and I am not able to do it due to those errors
Last updated: 2024-04-06