Post by ph0010421 on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Is that rung definitely being executed? Is the POU called?
Last updated: 2025-10-23
Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Yes it is called
Last updated: 2025-10-24
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
i m not familiar with installation/firmware/version/runtime, juste the machine worked fine before, and now kaput lol
Last updated: 2025-10-26
Passing EtheNetIP adapter device into a Function Block to access it's IO
CODESYS Forge
talk
(Thread)
Passing EtheNetIP adapter device into a Function Block to access it's IO
Last updated: 2025-10-28
Passing EtheNetIP adapter device into a Function Block to access it's IO
CODESYS Forge
talk
(Thread)
Passing EtheNetIP adapter device into a Function Block to access it's IO
Last updated: 2025-10-28
Passing EtheNetIP adapter device into a Function Block to access it's IO
CODESYS Forge
talk
(Thread)
Passing EtheNetIP adapter device into a Function Block to access it's IO
Last updated: 2025-10-28
Post by malte on OPC UA multiple Endpoints
CODESYS Forge
talk
(Post)
My CODESYS OPC UA server provides endpoints using both the hostname and the IP address. Connecting via the IP address works fine, but connecting via the hostname does not. The endpoint list shows both opc.tcp://<hostname>:4840 and opc.tcp://<ip>:4840. When using the hostname, the OPC UA client (UA Expert) fails to connect. Using the IP address connects without issues. Main goal is to conect via Python but opcua-asyncio seems to prefer the hostname. How can I configure CODESYS or my system so that the OPC UA connection via hostname also works properly or disable it completly? Running Codesys for PFC200 sl 4.18.0.0
Last updated: 2025-10-28
Post by aria13 on Has anyone fed ESP32 sensor data into CODESYS (via MQTT/Modbus)?
CODESYS Forge
talk
(Post)
Has anyone tried sending live sensor data from an ESP32 into a CODESYS runtime (for example via MQTT gateway or a Modbus bridge) to trigger PLC logic? I was reading an ESP32 → MQTT tutorial (https://www.theengineeringprojects.com/2021/11/esp32-mqtt.html) that shows how easy it is to publish sensor data from an ESP32, and I’m wondering how practical that is when tying the stream into industrial control software like CODESYS. I’ve also seen Arduino forum threads where people relay sensor streams to MQTT brokers and Raspberry Pi projects that bridge MQTT→Modbus, so I’m mainly curious about real-world issues: reliability, message latency, and simple patterns you’d recommend for safe PLC integration. Any tips, examples, or gotchas from folks who’ve done this?
Last updated: 2025-10-29
Post by eschwellinger on Modbus TLS Kommunikation
CODESYS Forge
talk
(Post)
aktuell bin ich mir nicht sicher ob das Modbus/TCP Security Protocol unterstützt, ich check das mal. Hast du ein Handbuch zu der Wallbox?
Last updated: 2025-11-06
Post by eschwellinger on Modbus TLS Kommunikation
CODESYS Forge
talk
(Post)
hi, das geht leider nicht mit aktivierter Verschlüsselung , sorry - denke aktuell bleibt dir nur auf Slave Seite die Verschlüsselung zu deaktivieren.
Last updated: 2025-11-09
Post by albertovalente on How extract JSONElement containing Array data
CODESYS Forge
talk
(Post)
Hi Creator: hazarath, Have you fix the problem? because I have the same issue Thanks a lot
Last updated: 2025-11-12
Post by albertovalente on How extract JSONElement containing Array data
CODESYS Forge
talk
(Post)
Hi Creator: hazarath, Have you fix the problem? because I have the same issue Thanks a lot
Last updated: 2025-11-12
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script
CODESYS Forge
talk
(Post)
Found out.Its script engine bug . Update to script engine version 4.2.0.0. and problem solved
Last updated: 2025-11-17
Get/Set I/O Address Mapping of DeviceObjects in python Script
CODESYS Forge
talk
(Thread)
Get/Set I/O Address Mapping of DeviceObjects in python Script
Last updated: 2025-11-17
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
The machine I'm currently using (Celeron J1900) already has the Kernel RT patch. I checked the performance according to the documentation. After running CyclicTest for 4 cores, the value for each core is around 6-7. I went through the entire process according to the documentation (I envy the TaskMonitor results in the documentation). The documentation states: "CODESYS Virtual Safe Time Provider The CODESYS Virtual Safe Time Provider is a standard interface that the user can use to transfer a second and external time base to the CODESYS Virtual Safe Control. The implementation is done as a client, which must run on another system with an independent time base." How do I implement this? I've been struggling for two weeks now - I'm too old to give up.
Last updated: 2025-11-17
Post by eschwellinger on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
Hi, just use the deploytool to deploy the Timeprovider on this external device: An set the IP of you SafeControl PLC
Last updated: 2025-11-18
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
Thank you for the information and support - I need to think this through again.
Last updated: 2025-11-18
Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Thread)
Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
Last updated: 2025-11-28
Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Thread)
Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
Last updated: 2025-11-28
Post by forklift on Anfänger hat Problem
CODESYS Forge
talk
(Post)
Hallo, ich bin Anfänger mit Codesys und Programm in ST. Wir haben FTS-Fahrzeuge die mit einer Wago-Steuerung ausgerüstet sind. Dies wurde von einer Firma vor Jahren programmiert. Die Firma ist nicht mehr erreichbar und nun sollen wir als Instandhalter diese FTS´en mit betreuen. Da wir aber nur Siemens benutzen(TIA, S7 und S5) haben wir keine Ahnung von der Steuerung. Ich wollte eigentlich nur Online gehen aber Codesys übersetzt das Offline Prg. und meckert das die nicht in Ordnung ist. Das Offline-Prg. ist das Original-Prg. villeicht könnt ihr mir weiter helfen Bild s. Anhang
Last updated: 2 days ago
Post by forklift on Anfänger hat Problem
CODESYS Forge
talk
(Post)
Hallo, ich bin Anfänger mit Codesys und Programm in ST. Wir haben FTS-Fahrzeuge die mit einer Wago-Steuerung ausgerüstet sind. Dies wurde von einer Firma vor Jahren programmiert. Die Firma ist nicht mehr erreichbar und nun sollen wir als Instandhalter diese FTS´en mit betreuen. Da wir aber nur Siemens benutzen(TIA, S7 und S5) haben wir keine Ahnung von der Steuerung. Ich wollte eigentlich nur Online gehen aber Codesys übersetzt das Offline Prg. und meckert das die nicht in Ordnung ist. Das Offline-Prg. ist das Original-Prg. villeicht könnt ihr mir weiter helfen Bild s. Anhang
Last updated: 2 days ago
VAR_INFO from inside of a FB to get info on the instance.
CODESYS Forge
talk
(Thread)
VAR_INFO from inside of a FB to get info on the instance.
Last updated: 22 hours ago
What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
CODESYS Forge
talk
(Thread)
What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
Last updated: 2025-11-12
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.